Пікірлер: 343
@ZahidMalik-xn9hz4 ай бұрын
If we set the battery level to 50 for wapda to enter the system on mks mode. What will happen in case of wapda failure or load shedding? Will the battery back up time be reduced?
@hamzanadeem8542 Жыл бұрын
I have a long question and looking forward to a detailed reply brother.. Isnt MKS mode dangerous from battery health point of view ?? Agar cloudy weather ho jaye achaanak during daytime toh solar input kam ho jayegi or maximum load battery par shift ho Jayega. Us se battery cycle bohat zada kharab nahi honge ? Because battery volt immediately drop karein ge or 50 V par wapda automatically in ho jayegi. Am i correct ? Secondly, agar second source throughout daytime battery par he rahay ga toh raat kay time battery backup available hoga ya nahi ?
@msaqib79bzu3 ай бұрын
Bhai Mera Fronus PV7000 hai. SUB mode hai. Din me agr solar production Zyada bhe ho load se to Amp meter pr utny Amps hee show kr rha hota hai jitna load hota hai. Uska kya ho skta hai???
@aatirehrarsiddiqui889410 ай бұрын
Same thing happens in SBU mode during the day. Its works with PV+ Batt during day.
@jamnadeem112 жыл бұрын
U are doing great work sir
@assadkhan4752 Жыл бұрын
Salam..really informative...u r great... i have put my inverter on mks ..but there is by pass always shoud i be worry?
@AGradeSolarKarachi Жыл бұрын
Plz clean panels.too ... Bypass means solar power is charging batteries while ur load is shiffted on wapda - this is because running load is greater then solar generation
@muddasirislam6 ай бұрын
Mks k liye battery zarori hai? Fronus ka ye model kaisa hai? Complaint to nhn ziada?
@recreatorsinn2 жыл бұрын
Dear, kindly share that have new unit of Fronus 6 Kw infineon Plus PV 7000, installed without batteries, when I go for MKS settings it dont save, kindly suggest me the best settings to less consumption of wapda units.
@malikshoaib2063 Жыл бұрын
Aoa! Mera fronus 6kv installed hai dry battries rakhi hen us k liye b yehi settings hongi kya??
@rafiksa29033 жыл бұрын
Nice information Sir...
@SAJJADAHMED-ze1gk Жыл бұрын
AOA, What is difference between MKS And SBU Mode.
@letsgochachu16673 жыл бұрын
Bohat achi detail di men bhi isi issue men phasa tha,thanks Second bhai agar inverter ki lcd lagi ho to ye wifi app pe deta send nahin karta agar lcd disconnect Kar den to data send karta he app pe is ka koi hal he bhai kia pls guide
@Ehsaasss2 жыл бұрын
bhai main ny same ye hi inverter lga rakha hai. bina battery k chala rha hun. lekin bina light k jab solar ka load 700 watt tak jata hai to inverter trip ho jata hai. main 520 watt k 6 panels lga rakhy hain.
@dagnypsaga Жыл бұрын
Aoa bhai fronus pv7000 ki best settings bata dain takeh wapda kam say kam ya na use ho. Main nay 540watt kay 6 pannels lagaay hain, battries kay baghair use kar raha hun. Jab light jaati hai to fridge kay load pay inverter 15 error deta hai trip kar jaata hai. Kya setting rakhun plz suggest karain. Abhi SUB ki setting ki hai installer nay. Kya 6 plates na kafi hain?
@Freefiretheoldgamer3 жыл бұрын
Assalam o alaikum sir fronus ka 6 kw ka wife setting bhi samjhaeye plz
@mohammadmuneeb1011 Жыл бұрын
salaam dear! mere pass bhi fromus hai mera KMS setting k baray main ye sawaal hai k agr solar or wapda dono available hain to kya battery say power ly ga load ya k pehly say solar power use kary ga agr sufficient na ho to wapda… agr wapda na ho to then battery say ly? kya ye baat theek hai?
@dinians Жыл бұрын
Mks pe RGB light blue hy means utility use ho ri hy... Kia RGB light purple 🟣 ni honi chahiye?
@farazpsc3 жыл бұрын
Arsalan bhai mks mode me ik masla hy jab inverter mode me jayga tu neutral wire me bhi phase show karta hy jaski wajha se home applienc ko kharab hojaygi
@TechTimeGSM3 жыл бұрын
Tubulor ka alag se option hai woh behter hai ya user setting krlen .
@patriot77013 жыл бұрын
A GRADE solar k kehne pe mks setting rkhi koi battery nae hti he is saying absolutely right bs qias aria hai.. battery is not at all used in mks mode.. as soon as generation decreases wapda gets in and if no wapda available only then battery is used just to run the load ... else no battery is used at all in mks mode . thanx a grade solar a grade kaam
@rmskarachi93204 ай бұрын
What about in night when it goes up 50 is it going back to battery 🔋
@qaritariq30654 жыл бұрын
ماشاءاللہ
@eshwarleemani12852 жыл бұрын
Brother in mks setting agar solar generation se load zyada hoga toh phr load battery pe jahega ya wapda pe? Or raat ke time pe ye wapda pe shift hojahega ya battery consume karega phr wapda pe jahega
@AGradeSolarKarachi2 жыл бұрын
Load wapda per jaye ga aur solar battery charge kere ga
@muhabbatali79704 жыл бұрын
ویلڈن سر
@messedup3503 жыл бұрын
Load was 2.6 pv generation was 2.3.. utility was on on mks. Battery was stable. Thn where is the extra power coming from
@TisButAHandle3 жыл бұрын
Yes, it's confusing.
@sajidkhanlashari2 жыл бұрын
Extra power Lose, because in this setting there is no feed back (you can see feed back option in off mode in this v log) to main source i.e wapda. You can only save that power when you have green meter by enable feed back to wapda.
@shahidmalik10942 жыл бұрын
battery will take some time to discharge to 53v then 52v
@loshipaari14393 жыл бұрын
Sir many apny gr me 4.2 fronus ka inverter lgya ha mje ye btay me kon c sitting rkho me ek electrision ho thori rahnomai kr dy
@raheelsager1199 Жыл бұрын
Sir ji 6kw ka Sako h 20 din me new betris black carban bana deye h kia masla h back up bhi Kam he ..... Exide HP 200..130a
@AGradeSolarKarachi Жыл бұрын
Regular Batteries are Not Recomended
@MuhammadSaeed-qn1cf3 жыл бұрын
Good job. my questions is user manual mn display per temperatures b show hota hy aur battery charging/ discharging current b Lykin real screen par show nahee hotaa aisaa q hy. Please explain...
@naveedbhattani18062 жыл бұрын
Some one asked me about frunus inverter faulty mode when put heavy load ? Is it correct
@syedsaadshah724262 жыл бұрын
Grid feeding on ki jaa skti hai digital 3 phase meter agar laga ho tou?
@hajifaysal23202 жыл бұрын
Assalamualaikum Brother is inverter k sath 350w wali kitni plates laga saktay Hain ziada say ziada۔plz lazmi jawab daina thank you ۔
@skburiro64683 жыл бұрын
Sir maire 18 panels risen ke lage howe hen jismen 2500 ke 4 tubler batteries osaka ki lagae howe hen kiya jo apne is video main setting set ki he kia main wohi set keron to performance kesi hogi kyun jo abhi setting lagi howe he us se ak to batteries discharge jaldi hojati he aur din main solar bhi kam sahi nahi ker sahi kiya issue hoskta he ap bata sakte hen sir
@iftikharahmed5794 Жыл бұрын
Agr batery serf sun say hi charge karna chahy tu kun sa parameter use karygay
@shayyankhand4248 ай бұрын
What to do when its on grade? Can we charge battery with 6kv gernator when wapda is not available for long?
@AGradeSolarKarachi8 ай бұрын
Yes But Generator Should Be of Good Quality
@muhammadzahidmalik8715 Жыл бұрын
Thanks for important sharing. I've question. At evening inverter is always on, fan is started always. There is always load on wapda even battery is fully charged 54.1 Why it always consume units.
@saeedahmad22542 ай бұрын
Load shadding agr buhat kam ha raat ko wur battry backup b acha ha to setting charging change kr dein oso pe
@saeedahmad22542 ай бұрын
Oso kr dein invertor fan bnd ho jayega.
@imranakbar23242 жыл бұрын
Sir mera system 6 kv ha. Batteries Daewoo 225 wali hain. June 2021 main Sara system installed kraya tha. Now problem is this k inverter batteries detect ni kr ra. Batteries 0 charging show kr ri hain. Bi batteries boht Achi condition main hain. Error show kr ra ha
@AGradeSolarKarachi2 жыл бұрын
Battery Side Ka Fuse to nehin jal geya ??? Koi breaker attach kiya hai ??? Batteryke induvudal volt check kerian ya phir inverter ko service center se check kerwain
@cecosian0073 жыл бұрын
Salam bro I have installed system yesterday and the reading r blinking .. and priority bhi USB py hai SuB py nai change ho rahi ..
@mohammadasrar5147 Жыл бұрын
3.6 kv me bettery cut off nae ho rae Sara din rat charge hoty heat b hoty kia setting karon ??
@haseebmoin Жыл бұрын
MKS setting m agr solar production kam ho to ye wapda ki bajai battery se q keta h jb isko kami utility se puri kray
@azharmahmood45474 жыл бұрын
Good useful video but only for expertise. Using so many words of English. The video has been shooted keeping in mind that all viewer are electrical engineer. Please shoot video keeping in mind a common person who is interested in solar system but has average knowledge if solar.
@asimjan4382 жыл бұрын
SNo. 12 did not go beyond 50. I checked several time
@harisjavaid58302 жыл бұрын
As salaam u alykum . I have 4.2 fronus inverter . I have set phoneix tx1800 battery on tubaler because flooded is not giving me backup . It's showing me 29.6 vdc on inverter screen . Fronus Tbl setting will damage my batteries ?
@saqlainmaqsood89312 жыл бұрын
mery pas 3.6kw ka inverter hai us pr 3 fan chlty fault no. 7 dy rha over load ka likn mery panel 540w k 4 lagy hai fan just 3 chal rhy kya krna chahy muju?
@iq9743 жыл бұрын
اسلام وعلیکم جناب میں نے آپکی ویڈیوز دیکھیں فرونس انورٹر کے بارے میں میں نے 4عدد used 200 بیٹری لگائی ہوئی ہیں تو سیٹنگ میں فلڈڈ پر ان کروں یا used پر
@immishaikh63693 жыл бұрын
Sir aoa sir meray pass fronus 4.2 hai mujhe 12 number option p 23 p rakhna hai ya 24.5 p and 13 number option p full p rakho ya 27 as default p rakho main chata ho meri settings aisi ho k battery zyada solar p charge ho
@AGradeSolarKarachi3 жыл бұрын
12 No ayp apni choice per set nehin ker sekte
@Abdulmoiz-bk9mt3 жыл бұрын
4.2kw ka fronus ka mks setting main without battery working ho skti haibya nhi?
@AGradeSolarKarachi3 жыл бұрын
No - Without Battery SUB
@AGradeSolarKarachi3 жыл бұрын
2020 ke sub models mein yeh feature avalible hai
@sohailbukhari61873 жыл бұрын
Lcd py kch second kaliy 01 fault code show hua ha jab ap mks mode py shift kia ha. Kia waja ha plz explain?
@Ak-qk3iy Жыл бұрын
I have a question Wapda solar sharing he aur battery sath attach ni he.jb wapda chla jata he to solar jb ac chlta he to solar band ho jata he bar bar
@AGradeSolarKarachi Жыл бұрын
System Begair Wapda Ya Begair Battery - Single Source per Nehin Chal Sekta - Koi bhi 2 Sources Lazmi Hain
@DaArtist202 жыл бұрын
Bro mene bhi yehe lagwaya hay but me satisfy ni hora jino nay install kia hay kia ap mere inverter ki settings chk kr sakty hay agr apko me pic send krn??
@ABASIT-th7qg3 жыл бұрын
Salam Wapda sharing doka ha user k lie .. 6 kw frouns ka inverter ha jo Wapda sharing ka option b rakha howa ha. Bhir b wapda say normal ki bajli kha raha ha. Main wapda sy light off kar di thi phir wapda sy bjili ni kah raha tha...
@Aiman_Cooking_Tips2 жыл бұрын
Sir battery ketny volt par full hoti h 48 volt
@Asadabbas-yu4wy2 жыл бұрын
Sir I want to use fronus inverter 6.2 kw pv7000 model without batteries I have 12 solar panels of 545w plz guide me the best method of setting
@VOLGFRIENDS43203 жыл бұрын
Bhai mn ne ekli battery pe lagwaya hai yshi UPS but battery LCD pe show ni kr reha
@abdullsubhan8585 Жыл бұрын
Aoa, I am having a problem My sola5 is sufficient for my daily house load and mostly more. But during evening or at dawn i.e at 7am and onward. My solar generation is low and it uses battery and after that it switches to wapda. Solar charges battery and it shifts to solar and battery. Again this cycle starts. Any fix
@AGradeSolarKarachi Жыл бұрын
U may Set 48 Volt in 12 No Menu
@abdullsubhan8585 Жыл бұрын
@@AGradeSolarKarachi it will drain battery more and i want battery to stay untouched. Plus why does it say in manual that in mks solar and utility will be used simultaneously during unsufficient load. ABattery is only for backup power
@EONLINESTORECOMPK3 жыл бұрын
AOA, FRONUS 4.2 MKS aur SBU mode p battery mode p nai ata. Breaker off karna parta h.....sane yahi settings h jo ap n bataee h but no solution.. please reply
@AGradeSolarKarachi3 жыл бұрын
Bahi MKS Use Kerain SBU ki Terah Hei Perform Kere Ga Pehle Solar Use hoga phir battery slightly use hogi then wapda run ho jaye ghi
@TheArslan725 Жыл бұрын
Phir SBU or MKS mein kia farq hai ?
@AliAhmad-ur7db Жыл бұрын
Assalamu Aliakum Bhai mks setting ma 6kw ma batteries ki setting kaise or kia karain kindly bata dain plz
@mohammadsalmangandapur91382 жыл бұрын
Aoa sir. Agar netmeter laga hu tab mku ki jaga konsi setting rakhni chahiye k wapda k sath unit sharing chalti rahay?
@AGradeSolarKarachi2 жыл бұрын
Utility or SUB
@Ahmadsolarpoint3 жыл бұрын
Bhi is ko sirf solar pe chla ho to ksy kra ge....wapda nai Deni or na hi battery lagni he.....18 plate he 430wt ki 48 v dc
@AGradeSolarKarachi3 жыл бұрын
Bahi be shaq 100 wali battery lagayian lakin lagayin zeroor werna ideal result nehin mile ga
@jahanzaibkhan6823 жыл бұрын
Your system is 6KV and it is generating just 2.3? Why
@abdulwaaseihsultan77333 жыл бұрын
Very nice. I have a question dear. What'll happen if we use MKS in the evening after no solar energy is available? How will it prioritize ac and battery?
@AGradeSolarKarachi3 жыл бұрын
It will first shift to wapda and in absence of wapda it will shift on Batteries. it do it automatically on MKS but if solar support is not sufficient at day time it will put load on Wapda and solar will on charge batteries.
@abdulwaaseihsultan77333 жыл бұрын
@@AGradeSolarKarachi thanks
@asifanjum8704 Жыл бұрын
No one has the answer for this
@dinians Жыл бұрын
My question is why RGB light color is blue 🔵 (utility mode) in mks setting. It should be purple 🟣 (pv mode) in day time. Isn't it?
@story-land-e9l2 жыл бұрын
i have 6kw pv7000 model of fronus. i want to use wapda + battery at same time in night. so please help me
@librastar20032 жыл бұрын
I experimented my self, MKS pe agar load solar ki power se ziada ho jata hai tuo inverter battery se sharing shuru kar deta, jo ke achi baat nahi hai batteries ko just backup ke liye he rakhna chiye warna battery life bhut jaldi drop ho jaye gi, es liye me sugges karu ga ke SUB option he best hai, jis mein agar load solar power se ziada ho jata hai tuo wo wapda se sharing kar leta hai par batteries use nai karta.
@muhammadsiddique30362 жыл бұрын
SUB per solar sy load ziada ho to wapda in ho jati hy sharing to nhn kerta
@rashidahmed77842 жыл бұрын
MashallAllah MashallAllah
@muhammadammarsabar72563 жыл бұрын
Thank u sir.
@zahidhussain123453 жыл бұрын
2.3 kw is generation and load is 2.5kw. (difference is 200watt) from where 200 watt system is managing.
@AGradeSolarKarachi3 жыл бұрын
Sir It is Using Flot Charging Current to Sustain Load as Batteries Are Set on 56 and In Video Batteries are on 54 So the Energy commonly known as Flotting Current is Used By the Inverter to Manage its System
@malikshoaib2063 Жыл бұрын
Battries
@ahsanfarooqi28052 жыл бұрын
sir pennal kis company ky hay or is ky sat kon sy bahter rahy gy ketnay watt ky
@AGradeSolarKarachi2 жыл бұрын
400W - Risen
@syedkaramkhandaudzaidaudza9473 жыл бұрын
Sir nechay jo ek taraf battery 99feesad sho karta os k samnay 46.47. 34 kabi atajata hy ye keya dekata hy
@hassansyed56612 жыл бұрын
Fronus PV7000 kesa model ha?
@shahbazsheikh7403 Жыл бұрын
Assalam u Alikum bhai Ya inverter battery utha na rha ho to us ka kia solution ha Means 4 battery Attach ha TA 1800 Osaka lakin battery na to charge kr rha ha naa backup da rha or screen pr bp ka option bhi da rha batteries Attach hona ka bawajod is ka koi solution btyyy plzz
@chhasnain74683 жыл бұрын
Left side pr kya show ho rha 48% ?
@taimoormirza43563 жыл бұрын
Bro Agar batteries ki charging only solar se krna ho.or wapda se na krna ho. To uska mode konsa use kryn gy?
@Allslowedandreverb3073 жыл бұрын
OSO krdo 15 number per aur battery cutoff voltage 50 percent krdo
@hafeezshah41593 жыл бұрын
Sir 4.2 kw inverter pe 12 no wli setting konsi rakh len ?
@Team_Kashee2 жыл бұрын
aslam alikum dear Fronus 4.2kw ke mks setting mai solar off hony k bd wapda battries ko chrg krta ha ya nhe
@AGradeSolarKarachi2 жыл бұрын
Charging ke liye 16 No Menu hai Cso Means Raat ko wapda battery charge kere Oso means sirif solar battery charge kere Snu means ke din ho ya raat wapda aur solar dono milker charge kerian
@AGradeSolarKarachi2 жыл бұрын
Mks ka matlab itna hai jub solar aa jaye to wapda sharing khtam ho jaye aur shaam mein jub solar kam ho jaye to phir wapda automatically inho jaye system mein
@Team_Kashee2 жыл бұрын
@@AGradeSolarKarachi thanks jnb
@Team_Kashee2 жыл бұрын
@@AGradeSolarKarachi acha sir ye b clear kr dyn k jb mai solar pr water pump chlata ho to solar k watt 460 sy drop ho k 380 tk a jaty ha ye kya problem ho skti ha agr koi problem ha to es ka kindly hal b bta dyn ap ke bri mhrbani ho ge
@AGradeSolarKarachi2 жыл бұрын
@@Team_Kashee jub load pere ga to volt kam hun ge its natural بطور مثال اگر آپ دس کلو کا وزن آسانی سے اٹھا سکتے ہیں تو بیس کلو پر آپکی پرفارمنس پر اثر آ جائے گا اسی طرح جب انورٹر پر لوڈ بڑھے گا تو وہ لوڈ سولر پر شفٹ ہوگا تو انرجی کی ضرورت بڑھے گی جس پر تھوڑا سا کرنٹ فال کرے گا۔ لیکن زیرو نہیں ہوگا۔
@infsaqib3 жыл бұрын
Bro jo ap na mk setting ki ha es main agar clouds hon to phir kia karian sub par ya
@AGradeSolarKarachi3 жыл бұрын
Cloudy mosem mein SUB is the suitable option
@rajputbilal3 жыл бұрын
If have the same inverter installed in my home, just want to know if we don't install batteries and wanted that solar supplies the electricity in absence of Wapda, Is it possible to get electricity without batteries and wapda in Day Time
@AGradeSolarKarachi3 жыл бұрын
If u will install 7KW Solar then u will be able to run 2.5-3.5KW without battery and without wapda - for proper vmiii running Wapda or K-Electric is necessary
@wasimjeens3 жыл бұрын
Am using fronus 3.6 with 8 plates. Problem yah hy k clear weather mn bhi total load aor sollar generation ka difference bht zada hy. Means load 500 watt ho to generation 150 watt hoti hy. Jsy he load 900 watt kro to generation 400 watt hojati . Means hamesha 300 sy 400 watt ka difference rehta hy.
@eqabelectrician8980 Жыл бұрын
Wos time ap pv k brker of on karlo pir thek ho jyaega Aur dosra bat ap nai kom sa panel lagye hai
@saqlainmaqsood89312 жыл бұрын
Mks kea hai likn kal to wapda chor dea tha likn aj suba ka off ni hu rhi wapda
@shortfun21393 жыл бұрын
battery ko "use" pa set karny sa battery ky ooper "Li" ka icon aata , does it mean lithium battery ? par battery tu tubular ha , please guide.
@Empathysympathy13 жыл бұрын
Screen panel me Battery signs KY between Jo box bna HOA ha. Wow kis ko indicate krta ha. Mery inverter pa is box me error sign KY Sath 10 likha a rha ha. Please tell me what the actual problem is?
@maryamchannel35662 жыл бұрын
Ma sha Allah
@rizwanmehmood29843 жыл бұрын
sir MKS & SBU mein kitna difference ha ? kyun k Solar battery then utility in SBU & same aap ne btaaya MKS ka bhi
@shanimuhammadshahzad10073 жыл бұрын
ڈفرنس یہ ہے کی جب آپکا لوڈ ہے 5 کلو واٹ کا اور سولر دے رہا ہے 4 کلو واٹ تو بجائے اپکا لوڈ ٹھیک طرح سے نا چلے تو 1 کلو واٹ سولر واپڈا سے لے لے گا
@muhammadsiddique30362 жыл бұрын
@@shanimuhammadshahzad1007 wapda to in hojai per 1kw to wapda nahin deti na q k wapda in hoty he 5kw wapda oer chalmy lagta hy or battery charging bhe wapda per hoti hy real time sharing to nahn howe
@saqlainmaqsood89312 жыл бұрын
MkS setting ki hai likn 9 baj rhy Wapda cut off ni hu rhi kya krna chahy mujy k wapda off hu jy
@foodiemoodie5827 Жыл бұрын
Agr m SUB settings rakho to kitni wapda mix karta hai system?
@AGradeSolarKarachi Жыл бұрын
60% Wapda Share in SUB Setting
@foodiemoodie5827 Жыл бұрын
@@AGradeSolarKarachi no bro. I checked puray din m just 1 unit use howa SUB per. Ap kesay calculate kar rahay hai.
@foodiemoodie5827 Жыл бұрын
Bro aik aur question hai, agr m MKS karta ho setting. Aur load zaida honay ki condition m wapda per shift ho jata load, then total wapda chaly ga tb ya mixing hogi?
@asimjan4382 жыл бұрын
We have 6 kw installed but the PV voltage fluctuation is there between 470 - 370 VDC. Is it normal?
@AGradeSolarKarachi2 жыл бұрын
Load.increase hone per.voltage humesha drop hun ge aur phir stable hun ge
@FaheemKhan-pj3vw Жыл бұрын
How can we disable it to charge by wapda in the evening?
@AGradeSolarKarachi Жыл бұрын
Put on OSO in 16 No Setting
@danishahmed49994 жыл бұрын
Nice
@usman-en8kk3 ай бұрын
mks py mera inverter wapda ko off ni kr rha
@Blueworld950 Жыл бұрын
Pv2200 model ki sharing kesay band hogi
@shahzadadil7742 жыл бұрын
Bhai aise settings konsi hay jes me batteries serf solar pe charge hon wapda pe na ho behsak rat ho ya den batteries serf solar se charge hon
@saeedahmad22542 ай бұрын
Oso charging mode
@uniquesolar2 жыл бұрын
Bhai 24volt inverter ma 12 number kitny rakhny chaye
@AGradeSolarKarachi2 жыл бұрын
22 or 23
@ashrafmuhammad4123 жыл бұрын
What stands for MKS.???
@waqarahmed14122 жыл бұрын
SBU setting me shamko battry 100% nahi hoti or 1no.setting me solar karen tu volt wapda k aate hn jo kam hote hn.
@KhadimHussainaladeed3 жыл бұрын
I have two mono panels of 300w and want to updrade my solar system can I use these panels with 535 mono perks
@AGradeSolarKarachi3 жыл бұрын
No
@ejazahmed45542 жыл бұрын
Firmware upgrade krwana hai service center kaha hai
@shabbarbokhari83413 жыл бұрын
5000 w ka--heater-chalane-k-liye-aap-ki-advice-darkar-hy-heater-220-w-pe-hume-chalana-hy-2-ghantey-k-liye
@frazhasan59272 жыл бұрын
Fronus pv7000 ki lcd ko read karna bataen ke kis icon ka kya matlab hai
@w9300i4 жыл бұрын
What is difference between MKS and SBU? Are they not the same thing?
@AGradeSolarKarachi4 жыл бұрын
Both are Entirely Different
@zafarcommunicationgharo12792 жыл бұрын
@@AGradeSolarKarachi ..?
@hassanaudio4756 Жыл бұрын
@@AGradeSolarKarachi plz elaborate the difference
@AdeelSolarExpert2 жыл бұрын
SBU ki setting save hai battery full charge hai phir b rat ko inverter k electric se load chala RHA hai is ki waja kya hai
@mrrashid70573 ай бұрын
Mks settings kasi ha
@hassaanv13 жыл бұрын
Mks mode par rakh kar battery voltage bahut taizi se Gira aur 50 par a kar wapda in ho gaya.. Load 500w tha aur generation 400w.. Panel utilization 10 percent bhi nahn thi.. I don't get it
@muhammadsaadmemon22573 жыл бұрын
Panels check karain. Agar load zyada hai tu battery drain hogi