Live Test MKS Setting On FRONUS 6.0KW Inverter

  Рет қаралды 57,784

A Grade Solar Karachi

A Grade Solar Karachi

Күн бұрын

For Product Purchase 03332597049, 03212900000, 03453811113.

Пікірлер: 343
@ZahidMalik-xn9hz
@ZahidMalik-xn9hz 4 ай бұрын
If we set the battery level to 50 for wapda to enter the system on mks mode. What will happen in case of wapda failure or load shedding? Will the battery back up time be reduced?
@hamzanadeem8542
@hamzanadeem8542 Жыл бұрын
I have a long question and looking forward to a detailed reply brother.. Isnt MKS mode dangerous from battery health point of view ?? Agar cloudy weather ho jaye achaanak during daytime toh solar input kam ho jayegi or maximum load battery par shift ho Jayega. Us se battery cycle bohat zada kharab nahi honge ? Because battery volt immediately drop karein ge or 50 V par wapda automatically in ho jayegi. Am i correct ? Secondly, agar second source throughout daytime battery par he rahay ga toh raat kay time battery backup available hoga ya nahi ?
@msaqib79bzu
@msaqib79bzu 3 ай бұрын
Bhai Mera Fronus PV7000 hai. SUB mode hai. Din me agr solar production Zyada bhe ho load se to Amp meter pr utny Amps hee show kr rha hota hai jitna load hota hai. Uska kya ho skta hai???
@aatirehrarsiddiqui8894
@aatirehrarsiddiqui8894 10 ай бұрын
Same thing happens in SBU mode during the day. Its works with PV+ Batt during day.
@jamnadeem11
@jamnadeem11 2 жыл бұрын
U are doing great work sir
@assadkhan4752
@assadkhan4752 Жыл бұрын
Salam..really informative...u r great... i have put my inverter on mks ..but there is by pass always shoud i be worry?
@AGradeSolarKarachi
@AGradeSolarKarachi Жыл бұрын
Plz clean panels.too ... Bypass means solar power is charging batteries while ur load is shiffted on wapda - this is because running load is greater then solar generation
@muddasirislam
@muddasirislam 6 ай бұрын
Mks k liye battery zarori hai? Fronus ka ye model kaisa hai? Complaint to nhn ziada?
@recreatorsinn
@recreatorsinn 2 жыл бұрын
Dear, kindly share that have new unit of Fronus 6 Kw infineon Plus PV 7000, installed without batteries, when I go for MKS settings it dont save, kindly suggest me the best settings to less consumption of wapda units.
@malikshoaib2063
@malikshoaib2063 Жыл бұрын
Aoa! Mera fronus 6kv installed hai dry battries rakhi hen us k liye b yehi settings hongi kya??
@rafiksa2903
@rafiksa2903 3 жыл бұрын
Nice information Sir...
@SAJJADAHMED-ze1gk
@SAJJADAHMED-ze1gk Жыл бұрын
AOA, What is difference between MKS And SBU Mode.
@letsgochachu1667
@letsgochachu1667 3 жыл бұрын
Bohat achi detail di men bhi isi issue men phasa tha,thanks Second bhai agar inverter ki lcd lagi ho to ye wifi app pe deta send nahin karta agar lcd disconnect Kar den to data send karta he app pe is ka koi hal he bhai kia pls guide
@Ehsaasss
@Ehsaasss 2 жыл бұрын
bhai main ny same ye hi inverter lga rakha hai. bina battery k chala rha hun. lekin bina light k jab solar ka load 700 watt tak jata hai to inverter trip ho jata hai. main 520 watt k 6 panels lga rakhy hain.
@dagnypsaga
@dagnypsaga Жыл бұрын
Aoa bhai fronus pv7000 ki best settings bata dain takeh wapda kam say kam ya na use ho. Main nay 540watt kay 6 pannels lagaay hain, battries kay baghair use kar raha hun. Jab light jaati hai to fridge kay load pay inverter 15 error deta hai trip kar jaata hai. Kya setting rakhun plz suggest karain. Abhi SUB ki setting ki hai installer nay. Kya 6 plates na kafi hain?
@Freefiretheoldgamer
@Freefiretheoldgamer 3 жыл бұрын
Assalam o alaikum sir fronus ka 6 kw ka wife setting bhi samjhaeye plz
@mohammadmuneeb1011
@mohammadmuneeb1011 Жыл бұрын
salaam dear! mere pass bhi fromus hai mera KMS setting k baray main ye sawaal hai k agr solar or wapda dono available hain to kya battery say power ly ga load ya k pehly say solar power use kary ga agr sufficient na ho to wapda… agr wapda na ho to then battery say ly? kya ye baat theek hai?
@dinians
@dinians Жыл бұрын
Mks pe RGB light blue hy means utility use ho ri hy... Kia RGB light purple 🟣 ni honi chahiye?
@farazpsc
@farazpsc 3 жыл бұрын
Arsalan bhai mks mode me ik masla hy jab inverter mode me jayga tu neutral wire me bhi phase show karta hy jaski wajha se home applienc ko kharab hojaygi
@TechTimeGSM
@TechTimeGSM 3 жыл бұрын
Tubulor ka alag se option hai woh behter hai ya user setting krlen .
@patriot7701
@patriot7701 3 жыл бұрын
A GRADE solar k kehne pe mks setting rkhi koi battery nae hti he is saying absolutely right bs qias aria hai.. battery is not at all used in mks mode.. as soon as generation decreases wapda gets in and if no wapda available only then battery is used just to run the load ... else no battery is used at all in mks mode . thanx a grade solar a grade kaam
@rmskarachi9320
@rmskarachi9320 4 ай бұрын
What about in night when it goes up 50 is it going back to battery 🔋
@qaritariq3065
@qaritariq3065 4 жыл бұрын
ماشاءاللہ
@eshwarleemani1285
@eshwarleemani1285 2 жыл бұрын
Brother in mks setting agar solar generation se load zyada hoga toh phr load battery pe jahega ya wapda pe? Or raat ke time pe ye wapda pe shift hojahega ya battery consume karega phr wapda pe jahega
@AGradeSolarKarachi
@AGradeSolarKarachi 2 жыл бұрын
Load wapda per jaye ga aur solar battery charge kere ga
@muhabbatali7970
@muhabbatali7970 4 жыл бұрын
ویلڈن سر
@messedup350
@messedup350 3 жыл бұрын
Load was 2.6 pv generation was 2.3.. utility was on on mks. Battery was stable. Thn where is the extra power coming from
@TisButAHandle
@TisButAHandle 3 жыл бұрын
Yes, it's confusing.
@sajidkhanlashari
@sajidkhanlashari 2 жыл бұрын
Extra power Lose, because in this setting there is no feed back (you can see feed back option in off mode in this v log) to main source i.e wapda. You can only save that power when you have green meter by enable feed back to wapda.
@shahidmalik1094
@shahidmalik1094 2 жыл бұрын
battery will take some time to discharge to 53v then 52v
@loshipaari1439
@loshipaari1439 3 жыл бұрын
Sir many apny gr me 4.2 fronus ka inverter lgya ha mje ye btay me kon c sitting rkho me ek electrision ho thori rahnomai kr dy
@raheelsager1199
@raheelsager1199 Жыл бұрын
Sir ji 6kw ka Sako h 20 din me new betris black carban bana deye h kia masla h back up bhi Kam he ..... Exide HP 200..130a
@AGradeSolarKarachi
@AGradeSolarKarachi Жыл бұрын
Regular Batteries are Not Recomended
@MuhammadSaeed-qn1cf
@MuhammadSaeed-qn1cf 3 жыл бұрын
Good job. my questions is user manual mn display per temperatures b show hota hy aur battery charging/ discharging current b Lykin real screen par show nahee hotaa aisaa q hy. Please explain...
@naveedbhattani1806
@naveedbhattani1806 2 жыл бұрын
Some one asked me about frunus inverter faulty mode when put heavy load ? Is it correct
@syedsaadshah72426
@syedsaadshah72426 2 жыл бұрын
Grid feeding on ki jaa skti hai digital 3 phase meter agar laga ho tou?
@hajifaysal2320
@hajifaysal2320 2 жыл бұрын
Assalamualaikum Brother is inverter k sath 350w wali kitni plates laga saktay Hain ziada say ziada۔plz lazmi jawab daina thank you ۔
@skburiro6468
@skburiro6468 3 жыл бұрын
Sir maire 18 panels risen ke lage howe hen jismen 2500 ke 4 tubler batteries osaka ki lagae howe hen kiya jo apne is video main setting set ki he kia main wohi set keron to performance kesi hogi kyun jo abhi setting lagi howe he us se ak to batteries discharge jaldi hojati he aur din main solar bhi kam sahi nahi ker sahi kiya issue hoskta he ap bata sakte hen sir
@iftikharahmed5794
@iftikharahmed5794 Жыл бұрын
Agr batery serf sun say hi charge karna chahy tu kun sa parameter use karygay
@shayyankhand424
@shayyankhand424 8 ай бұрын
What to do when its on grade? Can we charge battery with 6kv gernator when wapda is not available for long?
@AGradeSolarKarachi
@AGradeSolarKarachi 8 ай бұрын
Yes But Generator Should Be of Good Quality
@muhammadzahidmalik8715
@muhammadzahidmalik8715 Жыл бұрын
Thanks for important sharing. I've question. At evening inverter is always on, fan is started always. There is always load on wapda even battery is fully charged 54.1 Why it always consume units.
@saeedahmad2254
@saeedahmad2254 2 ай бұрын
Load shadding agr buhat kam ha raat ko wur battry backup b acha ha to setting charging change kr dein oso pe
@saeedahmad2254
@saeedahmad2254 2 ай бұрын
Oso kr dein invertor fan bnd ho jayega.
@imranakbar2324
@imranakbar2324 2 жыл бұрын
Sir mera system 6 kv ha. Batteries Daewoo 225 wali hain. June 2021 main Sara system installed kraya tha. Now problem is this k inverter batteries detect ni kr ra. Batteries 0 charging show kr ri hain. Bi batteries boht Achi condition main hain. Error show kr ra ha
@AGradeSolarKarachi
@AGradeSolarKarachi 2 жыл бұрын
Battery Side Ka Fuse to nehin jal geya ??? Koi breaker attach kiya hai ??? Batteryke induvudal volt check kerian ya phir inverter ko service center se check kerwain
@cecosian007
@cecosian007 3 жыл бұрын
Salam bro I have installed system yesterday and the reading r blinking .. and priority bhi USB py hai SuB py nai change ho rahi ..
@mohammadasrar5147
@mohammadasrar5147 Жыл бұрын
3.6 kv me bettery cut off nae ho rae Sara din rat charge hoty heat b hoty kia setting karon ??
@haseebmoin
@haseebmoin Жыл бұрын
MKS setting m agr solar production kam ho to ye wapda ki bajai battery se q keta h jb isko kami utility se puri kray
@azharmahmood4547
@azharmahmood4547 4 жыл бұрын
Good useful video but only for expertise. Using so many words of English. The video has been shooted keeping in mind that all viewer are electrical engineer. Please shoot video keeping in mind a common person who is interested in solar system but has average knowledge if solar.
@asimjan438
@asimjan438 2 жыл бұрын
SNo. 12 did not go beyond 50. I checked several time
@harisjavaid5830
@harisjavaid5830 2 жыл бұрын
As salaam u alykum . I have 4.2 fronus inverter . I have set phoneix tx1800 battery on tubaler because flooded is not giving me backup . It's showing me 29.6 vdc on inverter screen . Fronus Tbl setting will damage my batteries ?
@saqlainmaqsood8931
@saqlainmaqsood8931 2 жыл бұрын
mery pas 3.6kw ka inverter hai us pr 3 fan chlty fault no. 7 dy rha over load ka likn mery panel 540w k 4 lagy hai fan just 3 chal rhy kya krna chahy muju?
@iq974
@iq974 3 жыл бұрын
اسلام وعلیکم جناب میں نے آپکی ویڈیوز دیکھیں فرونس انورٹر کے بارے میں میں نے 4عدد used 200 بیٹری لگائی ہوئی ہیں تو سیٹنگ میں فلڈڈ پر ان کروں یا used پر
@immishaikh6369
@immishaikh6369 3 жыл бұрын
Sir aoa sir meray pass fronus 4.2 hai mujhe 12 number option p 23 p rakhna hai ya 24.5 p and 13 number option p full p rakho ya 27 as default p rakho main chata ho meri settings aisi ho k battery zyada solar p charge ho
@AGradeSolarKarachi
@AGradeSolarKarachi 3 жыл бұрын
12 No ayp apni choice per set nehin ker sekte
@Abdulmoiz-bk9mt
@Abdulmoiz-bk9mt 3 жыл бұрын
4.2kw ka fronus ka mks setting main without battery working ho skti haibya nhi?
@AGradeSolarKarachi
@AGradeSolarKarachi 3 жыл бұрын
No - Without Battery SUB
@AGradeSolarKarachi
@AGradeSolarKarachi 3 жыл бұрын
2020 ke sub models mein yeh feature avalible hai
@sohailbukhari6187
@sohailbukhari6187 3 жыл бұрын
Lcd py kch second kaliy 01 fault code show hua ha jab ap mks mode py shift kia ha. Kia waja ha plz explain?
@Ak-qk3iy
@Ak-qk3iy Жыл бұрын
I have a question Wapda solar sharing he aur battery sath attach ni he.jb wapda chla jata he to solar jb ac chlta he to solar band ho jata he bar bar
@AGradeSolarKarachi
@AGradeSolarKarachi Жыл бұрын
System Begair Wapda Ya Begair Battery - Single Source per Nehin Chal Sekta - Koi bhi 2 Sources Lazmi Hain
@DaArtist20
@DaArtist20 2 жыл бұрын
Bro mene bhi yehe lagwaya hay but me satisfy ni hora jino nay install kia hay kia ap mere inverter ki settings chk kr sakty hay agr apko me pic send krn??
@ABASIT-th7qg
@ABASIT-th7qg 3 жыл бұрын
Salam Wapda sharing doka ha user k lie .. 6 kw frouns ka inverter ha jo Wapda sharing ka option b rakha howa ha. Bhir b wapda say normal ki bajli kha raha ha. Main wapda sy light off kar di thi phir wapda sy bjili ni kah raha tha...
@Aiman_Cooking_Tips
@Aiman_Cooking_Tips 2 жыл бұрын
Sir battery ketny volt par full hoti h 48 volt
@Asadabbas-yu4wy
@Asadabbas-yu4wy 2 жыл бұрын
Sir I want to use fronus inverter 6.2 kw pv7000 model without batteries I have 12 solar panels of 545w plz guide me the best method of setting
@VOLGFRIENDS4320
@VOLGFRIENDS4320 3 жыл бұрын
Bhai mn ne ekli battery pe lagwaya hai yshi UPS but battery LCD pe show ni kr reha
@abdullsubhan8585
@abdullsubhan8585 Жыл бұрын
Aoa, I am having a problem My sola5 is sufficient for my daily house load and mostly more. But during evening or at dawn i.e at 7am and onward. My solar generation is low and it uses battery and after that it switches to wapda. Solar charges battery and it shifts to solar and battery. Again this cycle starts. Any fix
@AGradeSolarKarachi
@AGradeSolarKarachi Жыл бұрын
U may Set 48 Volt in 12 No Menu
@abdullsubhan8585
@abdullsubhan8585 Жыл бұрын
@@AGradeSolarKarachi it will drain battery more and i want battery to stay untouched. Plus why does it say in manual that in mks solar and utility will be used simultaneously during unsufficient load. ABattery is only for backup power
@EONLINESTORECOMPK
@EONLINESTORECOMPK 3 жыл бұрын
AOA, FRONUS 4.2 MKS aur SBU mode p battery mode p nai ata. Breaker off karna parta h.....sane yahi settings h jo ap n bataee h but no solution.. please reply
@AGradeSolarKarachi
@AGradeSolarKarachi 3 жыл бұрын
Bahi MKS Use Kerain SBU ki Terah Hei Perform Kere Ga Pehle Solar Use hoga phir battery slightly use hogi then wapda run ho jaye ghi
@TheArslan725
@TheArslan725 Жыл бұрын
Phir SBU or MKS mein kia farq hai ?
@AliAhmad-ur7db
@AliAhmad-ur7db Жыл бұрын
Assalamu Aliakum Bhai mks setting ma 6kw ma batteries ki setting kaise or kia karain kindly bata dain plz
@mohammadsalmangandapur9138
@mohammadsalmangandapur9138 2 жыл бұрын
Aoa sir. Agar netmeter laga hu tab mku ki jaga konsi setting rakhni chahiye k wapda k sath unit sharing chalti rahay?
@AGradeSolarKarachi
@AGradeSolarKarachi 2 жыл бұрын
Utility or SUB
@Ahmadsolarpoint
@Ahmadsolarpoint 3 жыл бұрын
Bhi is ko sirf solar pe chla ho to ksy kra ge....wapda nai Deni or na hi battery lagni he.....18 plate he 430wt ki 48 v dc
@AGradeSolarKarachi
@AGradeSolarKarachi 3 жыл бұрын
Bahi be shaq 100 wali battery lagayian lakin lagayin zeroor werna ideal result nehin mile ga
@jahanzaibkhan682
@jahanzaibkhan682 3 жыл бұрын
Your system is 6KV and it is generating just 2.3? Why
@abdulwaaseihsultan7733
@abdulwaaseihsultan7733 3 жыл бұрын
Very nice. I have a question dear. What'll happen if we use MKS in the evening after no solar energy is available? How will it prioritize ac and battery?
@AGradeSolarKarachi
@AGradeSolarKarachi 3 жыл бұрын
It will first shift to wapda and in absence of wapda it will shift on Batteries. it do it automatically on MKS but if solar support is not sufficient at day time it will put load on Wapda and solar will on charge batteries.
@abdulwaaseihsultan7733
@abdulwaaseihsultan7733 3 жыл бұрын
@@AGradeSolarKarachi thanks
@asifanjum8704
@asifanjum8704 Жыл бұрын
No one has the answer for this
@dinians
@dinians Жыл бұрын
My question is why RGB light color is blue 🔵 (utility mode) in mks setting. It should be purple 🟣 (pv mode) in day time. Isn't it?
@story-land-e9l
@story-land-e9l 2 жыл бұрын
i have 6kw pv7000 model of fronus. i want to use wapda + battery at same time in night. so please help me
@librastar2003
@librastar2003 2 жыл бұрын
I experimented my self, MKS pe agar load solar ki power se ziada ho jata hai tuo inverter battery se sharing shuru kar deta, jo ke achi baat nahi hai batteries ko just backup ke liye he rakhna chiye warna battery life bhut jaldi drop ho jaye gi, es liye me sugges karu ga ke SUB option he best hai, jis mein agar load solar power se ziada ho jata hai tuo wo wapda se sharing kar leta hai par batteries use nai karta.
@muhammadsiddique3036
@muhammadsiddique3036 2 жыл бұрын
SUB per solar sy load ziada ho to wapda in ho jati hy sharing to nhn kerta
@rashidahmed7784
@rashidahmed7784 2 жыл бұрын
MashallAllah MashallAllah
@muhammadammarsabar7256
@muhammadammarsabar7256 3 жыл бұрын
Thank u sir.
@zahidhussain12345
@zahidhussain12345 3 жыл бұрын
2.3 kw is generation and load is 2.5kw. (difference is 200watt) from where 200 watt system is managing.
@AGradeSolarKarachi
@AGradeSolarKarachi 3 жыл бұрын
Sir It is Using Flot Charging Current to Sustain Load as Batteries Are Set on 56 and In Video Batteries are on 54 So the Energy commonly known as Flotting Current is Used By the Inverter to Manage its System
@malikshoaib2063
@malikshoaib2063 Жыл бұрын
Battries
@ahsanfarooqi2805
@ahsanfarooqi2805 2 жыл бұрын
sir pennal kis company ky hay or is ky sat kon sy bahter rahy gy ketnay watt ky
@AGradeSolarKarachi
@AGradeSolarKarachi 2 жыл бұрын
400W - Risen
@syedkaramkhandaudzaidaudza947
@syedkaramkhandaudzaidaudza947 3 жыл бұрын
Sir nechay jo ek taraf battery 99feesad sho karta os k samnay 46.47. 34 kabi atajata hy ye keya dekata hy
@hassansyed5661
@hassansyed5661 2 жыл бұрын
Fronus PV7000 kesa model ha?
@shahbazsheikh7403
@shahbazsheikh7403 Жыл бұрын
Assalam u Alikum bhai Ya inverter battery utha na rha ho to us ka kia solution ha Means 4 battery Attach ha TA 1800 Osaka lakin battery na to charge kr rha ha naa backup da rha or screen pr bp ka option bhi da rha batteries Attach hona ka bawajod is ka koi solution btyyy plzz
@chhasnain7468
@chhasnain7468 3 жыл бұрын
Left side pr kya show ho rha 48% ?
@taimoormirza4356
@taimoormirza4356 3 жыл бұрын
Bro Agar batteries ki charging only solar se krna ho.or wapda se na krna ho. To uska mode konsa use kryn gy?
@Allslowedandreverb307
@Allslowedandreverb307 3 жыл бұрын
OSO krdo 15 number per aur battery cutoff voltage 50 percent krdo
@hafeezshah4159
@hafeezshah4159 3 жыл бұрын
Sir 4.2 kw inverter pe 12 no wli setting konsi rakh len ?
@Team_Kashee
@Team_Kashee 2 жыл бұрын
aslam alikum dear Fronus 4.2kw ke mks setting mai solar off hony k bd wapda battries ko chrg krta ha ya nhe
@AGradeSolarKarachi
@AGradeSolarKarachi 2 жыл бұрын
Charging ke liye 16 No Menu hai Cso Means Raat ko wapda battery charge kere Oso means sirif solar battery charge kere Snu means ke din ho ya raat wapda aur solar dono milker charge kerian
@AGradeSolarKarachi
@AGradeSolarKarachi 2 жыл бұрын
Mks ka matlab itna hai jub solar aa jaye to wapda sharing khtam ho jaye aur shaam mein jub solar kam ho jaye to phir wapda automatically inho jaye system mein
@Team_Kashee
@Team_Kashee 2 жыл бұрын
@@AGradeSolarKarachi thanks jnb
@Team_Kashee
@Team_Kashee 2 жыл бұрын
@@AGradeSolarKarachi acha sir ye b clear kr dyn k jb mai solar pr water pump chlata ho to solar k watt 460 sy drop ho k 380 tk a jaty ha ye kya problem ho skti ha agr koi problem ha to es ka kindly hal b bta dyn ap ke bri mhrbani ho ge
@AGradeSolarKarachi
@AGradeSolarKarachi 2 жыл бұрын
@@Team_Kashee jub load pere ga to volt kam hun ge its natural بطور مثال اگر آپ دس کلو کا وزن آسانی سے اٹھا سکتے ہیں تو بیس کلو پر آپکی پرفارمنس پر اثر آ جائے گا اسی طرح جب انورٹر پر لوڈ بڑھے گا تو وہ لوڈ سولر پر شفٹ ہوگا تو انرجی کی ضرورت بڑھے گی جس پر تھوڑا سا کرنٹ فال کرے گا۔ لیکن زیرو نہیں ہوگا۔
@infsaqib
@infsaqib 3 жыл бұрын
Bro jo ap na mk setting ki ha es main agar clouds hon to phir kia karian sub par ya
@AGradeSolarKarachi
@AGradeSolarKarachi 3 жыл бұрын
Cloudy mosem mein SUB is the suitable option
@rajputbilal
@rajputbilal 3 жыл бұрын
If have the same inverter installed in my home, just want to know if we don't install batteries and wanted that solar supplies the electricity in absence of Wapda, Is it possible to get electricity without batteries and wapda in Day Time
@AGradeSolarKarachi
@AGradeSolarKarachi 3 жыл бұрын
If u will install 7KW Solar then u will be able to run 2.5-3.5KW without battery and without wapda - for proper vmiii running Wapda or K-Electric is necessary
@wasimjeens
@wasimjeens 3 жыл бұрын
Am using fronus 3.6 with 8 plates. Problem yah hy k clear weather mn bhi total load aor sollar generation ka difference bht zada hy. Means load 500 watt ho to generation 150 watt hoti hy. Jsy he load 900 watt kro to generation 400 watt hojati . Means hamesha 300 sy 400 watt ka difference rehta hy.
@eqabelectrician8980
@eqabelectrician8980 Жыл бұрын
Wos time ap pv k brker of on karlo pir thek ho jyaega Aur dosra bat ap nai kom sa panel lagye hai
@saqlainmaqsood8931
@saqlainmaqsood8931 2 жыл бұрын
Mks kea hai likn kal to wapda chor dea tha likn aj suba ka off ni hu rhi wapda
@shortfun2139
@shortfun2139 3 жыл бұрын
battery ko "use" pa set karny sa battery ky ooper "Li" ka icon aata , does it mean lithium battery ? par battery tu tubular ha , please guide.
@Empathysympathy1
@Empathysympathy1 3 жыл бұрын
Screen panel me Battery signs KY between Jo box bna HOA ha. Wow kis ko indicate krta ha. Mery inverter pa is box me error sign KY Sath 10 likha a rha ha. Please tell me what the actual problem is?
@maryamchannel3566
@maryamchannel3566 2 жыл бұрын
Ma sha Allah
@rizwanmehmood2984
@rizwanmehmood2984 3 жыл бұрын
sir MKS & SBU mein kitna difference ha ? kyun k Solar battery then utility in SBU & same aap ne btaaya MKS ka bhi
@shanimuhammadshahzad1007
@shanimuhammadshahzad1007 3 жыл бұрын
ڈفرنس یہ ہے کی جب آپکا لوڈ ہے 5 کلو واٹ کا اور سولر دے رہا ہے 4 کلو واٹ تو بجائے اپکا لوڈ ٹھیک طرح سے نا چلے تو 1 کلو واٹ سولر واپڈا سے لے لے گا
@muhammadsiddique3036
@muhammadsiddique3036 2 жыл бұрын
@@shanimuhammadshahzad1007 wapda to in hojai per 1kw to wapda nahin deti na q k wapda in hoty he 5kw wapda oer chalmy lagta hy or battery charging bhe wapda per hoti hy real time sharing to nahn howe
@saqlainmaqsood8931
@saqlainmaqsood8931 2 жыл бұрын
MkS setting ki hai likn 9 baj rhy Wapda cut off ni hu rhi kya krna chahy mujy k wapda off hu jy
@foodiemoodie5827
@foodiemoodie5827 Жыл бұрын
Agr m SUB settings rakho to kitni wapda mix karta hai system?
@AGradeSolarKarachi
@AGradeSolarKarachi Жыл бұрын
60% Wapda Share in SUB Setting
@foodiemoodie5827
@foodiemoodie5827 Жыл бұрын
@@AGradeSolarKarachi no bro. I checked puray din m just 1 unit use howa SUB per. Ap kesay calculate kar rahay hai.
@foodiemoodie5827
@foodiemoodie5827 Жыл бұрын
Bro aik aur question hai, agr m MKS karta ho setting. Aur load zaida honay ki condition m wapda per shift ho jata load, then total wapda chaly ga tb ya mixing hogi?
@asimjan438
@asimjan438 2 жыл бұрын
We have 6 kw installed but the PV voltage fluctuation is there between 470 - 370 VDC. Is it normal?
@AGradeSolarKarachi
@AGradeSolarKarachi 2 жыл бұрын
Load.increase hone per.voltage humesha drop hun ge aur phir stable hun ge
@FaheemKhan-pj3vw
@FaheemKhan-pj3vw Жыл бұрын
How can we disable it to charge by wapda in the evening?
@AGradeSolarKarachi
@AGradeSolarKarachi Жыл бұрын
Put on OSO in 16 No Setting
@danishahmed4999
@danishahmed4999 4 жыл бұрын
Nice
@usman-en8kk
@usman-en8kk 3 ай бұрын
mks py mera inverter wapda ko off ni kr rha
@Blueworld950
@Blueworld950 Жыл бұрын
Pv2200 model ki sharing kesay band hogi
@shahzadadil774
@shahzadadil774 2 жыл бұрын
Bhai aise settings konsi hay jes me batteries serf solar pe charge hon wapda pe na ho behsak rat ho ya den batteries serf solar se charge hon
@saeedahmad2254
@saeedahmad2254 2 ай бұрын
Oso charging mode
@uniquesolar
@uniquesolar 2 жыл бұрын
Bhai 24volt inverter ma 12 number kitny rakhny chaye
@AGradeSolarKarachi
@AGradeSolarKarachi 2 жыл бұрын
22 or 23
@ashrafmuhammad412
@ashrafmuhammad412 3 жыл бұрын
What stands for MKS.???
@waqarahmed1412
@waqarahmed1412 2 жыл бұрын
SBU setting me shamko battry 100% nahi hoti or 1no.setting me solar karen tu volt wapda k aate hn jo kam hote hn.
@KhadimHussainaladeed
@KhadimHussainaladeed 3 жыл бұрын
I have two mono panels of 300w and want to updrade my solar system can I use these panels with 535 mono perks
@AGradeSolarKarachi
@AGradeSolarKarachi 3 жыл бұрын
No
@ejazahmed4554
@ejazahmed4554 2 жыл бұрын
Firmware upgrade krwana hai service center kaha hai
@shabbarbokhari8341
@shabbarbokhari8341 3 жыл бұрын
5000 w ka--heater-chalane-k-liye-aap-ki-advice-darkar-hy-heater-220-w-pe-hume-chalana-hy-2-ghantey-k-liye
@frazhasan5927
@frazhasan5927 2 жыл бұрын
Fronus pv7000 ki lcd ko read karna bataen ke kis icon ka kya matlab hai
@w9300i
@w9300i 4 жыл бұрын
What is difference between MKS and SBU? Are they not the same thing?
@AGradeSolarKarachi
@AGradeSolarKarachi 4 жыл бұрын
Both are Entirely Different
@zafarcommunicationgharo1279
@zafarcommunicationgharo1279 2 жыл бұрын
@@AGradeSolarKarachi ..?
@hassanaudio4756
@hassanaudio4756 Жыл бұрын
@@AGradeSolarKarachi plz elaborate the difference
@AdeelSolarExpert
@AdeelSolarExpert 2 жыл бұрын
SBU ki setting save hai battery full charge hai phir b rat ko inverter k electric se load chala RHA hai is ki waja kya hai
@mrrashid7057
@mrrashid7057 3 ай бұрын
Mks settings kasi ha
@hassaanv1
@hassaanv1 3 жыл бұрын
Mks mode par rakh kar battery voltage bahut taizi se Gira aur 50 par a kar wapda in ho gaya.. Load 500w tha aur generation 400w.. Panel utilization 10 percent bhi nahn thi.. I don't get it
@muhammadsaadmemon2257
@muhammadsaadmemon2257 3 жыл бұрын
Panels check karain. Agar load zyada hai tu battery drain hogi
Real Time Sharing (Mks Sbu Sub)
8:31
Technical Guidance
Рет қаралды 19 М.
Fronus 3.6 & 4.2 Kw Solar Inverter  Complete Settings
17:09
Technical Guidance
Рет қаралды 5 М.
Running With Bigger And Bigger Lunchlys
00:18
MrBeast
Рет қаралды 122 МЛН
From Small To Giant Pop Corn #katebrush #funny #shorts
00:17
Kate Brush
Рет қаралды 72 МЛН
fronus 4.2 kw setting
16:42
Nazir solar system
Рет қаралды 18 М.
fronus 3.6kw solar Inverter best setting
8:45
Technical solar A-grade
Рет қаралды 25 М.
fronus pv 5200 battery setting
5:38
Umair solar energy fsd
Рет қаралды 11 М.
Big Mistake Of Solar System protections (avoid these mistakes )
21:05
Bijli Wala Bhai
Рет қаралды 24 М.
6 Kw Solar system without batteries with real time sharing complete price detail in Urdu Hindi
15:30
Raza Solar Power Easy Tutorials Hindi Urdu
Рет қаралды 57 М.
Fronus Pv 5200 Best Battery Settings ( infeon Reborn Series )
20:13
Technical Guidance
Рет қаралды 13 М.
Solar Inverter Settings Or Programmings
24:14
Technical Guidance
Рет қаралды 45 М.
Running With Bigger And Bigger Lunchlys
00:18
MrBeast
Рет қаралды 122 МЛН