Loud Clanking and Banging Steam Heat Pipes (How to Fix) | Water Hammer | Drain and Refill Boiler

  Рет қаралды 40,996

Everythings Broken

Everythings Broken

Күн бұрын

For a single pipe steam system if you are experiencing noisy clanking and knocking caused by a water hammer try following these steps to resolve:
1) Put a level on each radiator and make sure it's tilted towards the steam pipe.
2) Replace the air valves.
3) Make sure the shut-off valve is all the way open or all the way closed (not half-way open).
4) Make sure your boiler isn't over-filled. If it is drain it and replace the water so that it is only half-way up the sight glass window.

Пікірлер: 33
@italianitalian100
@italianitalian100 3 жыл бұрын
As a 24 year old plumber who owns a HVAC plumbing business I can tell you one you’re awesome for figuring this out on your own and plumbing is an amazing trade
@shogunkicksbutt127
@shogunkicksbutt127 3 жыл бұрын
was he right about setting the psi 12 to 15 pounds pressure? asking for a friend :p
@Cooliepops
@Cooliepops 3 жыл бұрын
I live in a four story walk up and this year the pipes are banging like never before. I'm going to look at the level of the rads in our place but I think the landlord will have to come in and drain the boiler as you did. Thanks for the vid. Now I can start the troubleshooting!
@elioselectric468
@elioselectric468 3 жыл бұрын
1.5 psi max. 12 to 15 haha. No
@jeffsmith2022
@jeffsmith2022 3 жыл бұрын
You are correct sir about learning a trade...I think that your radiator valves, vents. were a culprit here...
@ekfliu
@ekfliu 3 жыл бұрын
3:03 the horizontal box there is the auto water feeder it works like a low water cutoff and auto add water when low water level is detected. It could be broken that is why the boiler is over filled. 5:12 you need to turn the top and bottom ball valves to vertical this will bypass the auto feeder. Use the middle ball valve to manually add water until that defective feeder is replaced. Since the feeder is broken your LWCO could also be broken, so better manually check to make sure it is not. Very dangerous to have non working LWCO.
@stormbytes
@stormbytes 2 жыл бұрын
You're hilarious! Nice job on the video
@patrickmorrison6253
@patrickmorrison6253 2 жыл бұрын
i got knocking noise from radiators check valves next i did what next thing to the boiler and heat comes up no knocking very quiet feels like new thank you
@tomrichardson2099
@tomrichardson2099 3 жыл бұрын
Steam boiler should never be 12 to 15 pounds pressure. Set pressuretrol to 2 psi cut out pressure.
@randyjardee7024
@randyjardee7024 3 жыл бұрын
RLJ.....you need to figure out why the boiler overfilled, it may repeat.
@zachmanning9499
@zachmanning9499 Жыл бұрын
Steam should never be over 2 psi
@DeathByLight
@DeathByLight 3 жыл бұрын
Very good tutorial, thank you for showing us how to fix the problem!
@landuongnov30
@landuongnov30 Жыл бұрын
It's an old video but I am sure you had the same issue with the radiator the following day, right?
@OscarPerez-uq7zt
@OscarPerez-uq7zt Жыл бұрын
For ur info rads have a built in pitch they must be installed on a level floor
@miguelplg19
@miguelplg19 Жыл бұрын
You want a steam boiler to run below 2PSI, not between 12 and 15 PSI, that would be for a hot water system, not steam.
@benjaminday3868
@benjaminday3868 2 жыл бұрын
When he opened the lower valve on said "no water coming out of here so we are all set". NO, THATS THE PROBLEM YOUR RETURN LINE IS CLOGGED SO THE WATER TAKES TOO LONG TO RETURN TO THE BOILER THUS TRIGGERING THE LOWC, AND THE 12 PSI THING IS STUPID HI. HE HAS TO BE TROLLING.
@jdsbeau1
@jdsbeau1 11 ай бұрын
Hi, I just bought and installed an expansion tank because boiler relief valve would spurt water violently and I got hammering sounds. I did not check the levels or adjust the expansion tank - I didn't know it was required, though the factory adjustment would be normal and useful. Not so - when I got the furnace going again, the same thing happened. Is it the expansion tank ? Could I have killed the tank in one shot ? I already replaced the systems water pump and regulator and thermocoupler.
@bhf4u
@bhf4u 2 жыл бұрын
my steam system is set a a half pound and the differential wheel is set at 1. so maximum pressure is 1 1/2 psi
@Ariccio123
@Ariccio123 9 ай бұрын
You're on step 12 of "The 25 Steps in the Repair of a Vacuum Steam System" 😉🤣
@Mobil351
@Mobil351 3 жыл бұрын
The pressuretrol should be set at 1 and 3 , the differential set at two ,not 12 to 15 psi you took care of the noise by pitching the radiator that noise is caused by live steam coming in contact with accumulated trapped water. On steam boilers you should be draining a good bucket of water from the boiler once a month during the heating season. From the mud leg of the system. And would not recommend YOU setting or adjusting the pressuretrol in any way. As far as you finding people to take those service positions good luck now good luck. That would require hard work and long hours. Just sayin
@jentko
@jentko 2 жыл бұрын
You do not want the pressure to be 12-15 psi. You want that on a forced hot water system not steam.
@sanmac9621
@sanmac9621 9 ай бұрын
Why need to wait for water ?!!!! i drained all water 3 buckets and start heater. Am i missing something ? why need to wait ? well but my water level did not go low though i can see from tube,
@ulisescuellar4457
@ulisescuellar4457 Жыл бұрын
12 to 15 sounds extremely high for steam
@jasonbrown8726
@jasonbrown8726 Жыл бұрын
12 to 15 psi is for hot water baseboard. Steam should be no more than 2 psi!!!
@nickosuperintendant9514
@nickosuperintendant9514 3 жыл бұрын
Thats a Cheap air valve/ heat timer. Dont buy 7- $8 air valves. I buy Only Verivale made in USA. They are expensive. I learned my lesson in the first years as a Super Intendant of 75 family building.
@OscarPerez-uq7zt
@OscarPerez-uq7zt Жыл бұрын
U should buy Gorton air valves that come size by letter and number depending on the floor they are being installed not thise cheap ones u used
@Mark-fg9pf
@Mark-fg9pf 6 ай бұрын
Those auto feeders fail alot
@jordanfitch8355
@jordanfitch8355 3 жыл бұрын
This guy has no idea what he’s talking about your steam boiler should run a half a pound & the reason the water was so high was because he had no water going back to the boiler thats why when he opened up the wet return he had no water coming out
@OSCARANDRES039
@OSCARANDRES039 3 жыл бұрын
Can u elaborate more. How can the water be high when you have no water coming back to the boiler?? Where is the water coming from ?? I have a similar issue. Lately I've lower the water to about half and the next morning is all the way up fully filling the glass.
@Jwr1230
@Jwr1230 3 жыл бұрын
You might have air inside your system
@bhf4u
@bhf4u 2 жыл бұрын
@@Jwr1230 its steam not forced hot water
@bhf4u
@bhf4u 2 жыл бұрын
@@OSCARANDRES039 that auto fill is probably either set wrong or is defective.the water color was not healthy and the return may be plugged.when he opened that return drain there should still have been a little water draining. i would also check the pigtail to see if it is clear
@Jfeen617
@Jfeen617 2 жыл бұрын
@@Jwr1230 What happens when its all the way at the bottom?
Steam Boiler Banging/ Hammering Noises Leaky Air Vent
27:22
The HVAC Hacker
Рет қаралды 46 М.
Бенчик, пора купаться! 🛁 #бенчик #арти #симбочка
00:34
Симбочка Пимпочка
Рет қаралды 3,6 МЛН
Help Me Celebrate! 😍🙏
00:35
Alan Chikin Chow
Рет қаралды 90 МЛН
Mom had to stand up for the whole family!❤️😍😁
00:39
What is Water Hammer?
7:40
Practical Engineering
Рет қаралды 6 МЛН
Dunkirk Gas Steam Boiler Making Banging Sounds - Too Much Pressure or Clogged Wet Return or Both
24:38
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 34 М.
How to Fix Dunkirk Steam Boiler Banging & Air Valves Leaking Water - Bad Pressuretrol Replaced
40:52
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 32 М.
Forced-air Furnaces: The What, Why, and How
22:05
Technology Connections
Рет қаралды 1,3 МЛН
Steam System Balancing
5:15
NYCDadd
Рет қаралды 29 М.
Steam Radiator Not Working
39:52
BobsPlumbingVideos
Рет қаралды 119 М.
Near-Boiler Piping in Steam Heating Systems
24:40
Heating Help
Рет қаралды 45 М.
How Steam Vents Work | Emerson Swan
5:16
Emerson Swan, Inc.
Рет қаралды 71 М.
5 most common Boiler Problems 🔥🛠️
9:44
The HVAC Dope Show
Рет қаралды 12 М.
Cutting Fuel Bills with Venting in Steam Heating Systems
15:49
Heating Help
Рет қаралды 15 М.
Бенчик, пора купаться! 🛁 #бенчик #арти #симбочка
00:34
Симбочка Пимпочка
Рет қаралды 3,6 МЛН