Troubleshooting a Pressure Reducing Valve

  Рет қаралды 112,347

LunchBox Sessions

LunchBox Sessions

Күн бұрын

Пікірлер: 19
@praveenmishra1549
@praveenmishra1549 3 жыл бұрын
Thanks a lot for explaining importance of Pilot drain line.
@kikkheh
@kikkheh 7 жыл бұрын
Nice video and explanation, as usual, but this time I have a doubt. When you describe the areas of the main spool of the valve, you say that the annular (bottom) area help to move down the spool. For me this annular (bottom) area does not affect the spool, because on the upper part of the spool there is the same annular area, so these two are canceled. Either way the spool have to move down because the effect of the others. Greetings
@lunchboxsessions
@lunchboxsessions 7 жыл бұрын
That's true. Good observation. Thanks for pointing out that one detail. We'll produce an edited version at some point.
@kikkheh
@kikkheh 7 жыл бұрын
you're welcome. It is nice to help to improve your videos, which have been a tool of great help to me to better understand this area
@bobanppvc
@bobanppvc 3 жыл бұрын
Good catch
@thainguyenthe507
@thainguyenthe507 5 жыл бұрын
thanks for your videos
@ajsmith6106
@ajsmith6106 7 жыл бұрын
Thanks for your videos. Could you pls explain usage of double pilot operated check valve.
@pranit_19
@pranit_19 7 жыл бұрын
Why do we assign specific velocities to pressure, return and suction line of a hydraulic system? I didn't understand how efficiency is increased. can you hrlp me understand?
@andrewarmstrong9194
@andrewarmstrong9194 Жыл бұрын
How to test a pressure reducing I cartridge valve? I have a tractor thats giving me a fit. It has the parking brake valve with 2 electric solenoids back 2 back on the same valve stem. The first solenoid activates all the machine functions, the second deactivates the drive functions but still allows the boom and attachment to function. Beside that valve it has the PRS valve. My problem is when you turn the park brake off to have all functions everything works but very slow and weak, pressure only goes up to about 1000. But when you activate the brake the other solenoid takes over and the boom function works perfect pressure goes to 2500 psi Its a jcb skid steer.
@navneetkamboj00
@navneetkamboj00 5 ай бұрын
i have question, i have yuken pressure reducing modular valve but it is not reducing pressure. two ports x and y are for what use please explain
@nadeemzzz5599
@nadeemzzz5599 2 жыл бұрын
Hi , hope you are good. Wanted to know your views on Pressure reducing valves. When I checked, seems that they all have internal leakage through their pilot line. I mean , for a pressure reducing valve to work , the pilot line must drain oil to tank. So if any pressure reducing valve is connected to an accumulator, it will drain the accumulator till the preset pressure is reached and pilot drain flow will stop ! Am I right? Can pressure reducing valves be used with accumulators? For example, can we have a 3 way pressure reducing valve without internal leakage? Do we have any models of 3 way pressure reducing valves without leakage? Does leakage happen when valve is off ? For e.g suppose I have a 3 way proportional pressure reducing valve; when valve is off , output pressure is zero. If this valve is connected to an accumulator, will it drain all accumulator oil little by little? Will leakage occur when valve is off ? Thanks. Kind Regards.
@shoutitallloud
@shoutitallloud 7 жыл бұрын
What's the difference between pressure reducing and pressure relief valves?
@lunchboxsessions
@lunchboxsessions 7 жыл бұрын
One way to describe the difference is that relief valves limit the maximum pressure on the inlet side of the valve (note the dashed sensing/piloting line on valve inlet) where reducing valves limit the maximum pressure on the outlet side of the valve (note the dashed sensing/piloting line on the valve outlet). - Carl
@sathishr7774
@sathishr7774 4 жыл бұрын
Can pressure reducing valve allow reverse flow when pilot line is pressurised ?
@paulh5049
@paulh5049 2 жыл бұрын
No, because if pressure in the pilot line were to increase beyond system pressure, the valve would close, preventing flow.
@ehansaudinawab1138
@ehansaudinawab1138 4 жыл бұрын
CAN YOU SHARE TROUBLESHOOTING OF FACED PROBLEM AS WHEN PRESSURE REGULATE AND SET AT 1200PSI AFTER SOME TIME IT START FLUCTUATE AUTOMATIC +/- 400 FROM SET VALUE WHAT CAUSE IT HAPPEN ANY ONE CORRECT SOLUTION SHARE WITH ME.
@ruenhuaman7257
@ruenhuaman7257 7 жыл бұрын
Please make videos in Spanish?
@ajsmith6106
@ajsmith6106 7 жыл бұрын
Is this possible if I change the pressure to 70 bar will the doble pilot operated chcek vavle will work when strokeing cilinder outboard. drive.google.com/file/d/0B4QsoeucDE7KbW9PenRWNlRPZ2s/view?usp=sharing
Troubleshooting a Regenerative Lift Circuit
5:43
LunchBox Sessions
Рет қаралды 23 М.
Teaching: Relief Valve Basics
51:00
LunchBox Sessions
Рет қаралды 141 М.
OYUNCAK MİKROFON İLE TRAFİK LAMBASINI DEĞİŞTİRDİ 😱
00:17
Melih Taşçı
Рет қаралды 13 МЛН
Inside Out 2: ENVY & DISGUST STOLE JOY's DRINKS!!
00:32
AnythingAlexia
Рет қаралды 15 МЛН
小路飞嫁祸姐姐搞破坏 #路飞#海贼王
00:45
路飞与唐舞桐
Рет қаралды 26 МЛН
How To Interpret Pressure Valves
6:48
LunchBox Sessions
Рет қаралды 254 М.
How do Water Pressure Reducing Valves (PRV) Work?
26:04
Disney-McLane & Associates
Рет қаралды 31 М.
Farris 3800 Pilot Operated Relief Valve
5:38
Curtiss-Wright Corporation
Рет қаралды 150 М.
Pilot Operated Check Valve Cylinder Troubleshooting - Part 1
8:28
LunchBox Sessions
Рет қаралды 87 М.
Sources of Piston Pump Case Drain Flow
12:36
LunchBox Sessions
Рет қаралды 121 М.
How a gas regulator works
4:54
Deconstructed
Рет қаралды 144 М.
Pressure Relief Valves: Direct Acting and Pilot Operated
4:15
Engineering Technology Simulation Learning Videos
Рет қаралды 613 М.
Pressure Compensated Pump Adjustments - Part 1
8:34
LunchBox Sessions
Рет қаралды 676 М.