#Indiamart #OvercurrentRelay #HavellsACCL #ElectricConverters Get the best price at Indiamart Overcurrent Relay:dir.indiamart.com/impcat/overcurrent-relay.html?YTI2& Havells ACCL:dir.indiamart.com/impcat/havells-accl.html?YTI2& Electric Converters:dir.indiamart.com/impcat/electric-converters.html?YTI2&
@DeepakPatel-ow7co Жыл бұрын
Sum number
@pratishpatil12188 күн бұрын
Very good information sir
@BOLBULBULIndustrialElectrical6 күн бұрын
Thank you
@kushalkumar7261 Жыл бұрын
Very good vedio
@BOLBULBULIndustrialElectrical Жыл бұрын
Thank you
@prashantmishra1183 Жыл бұрын
DC motor me kitna pole hota hai
@prashantmishra1183 Жыл бұрын
Kindly share esp transformer
@zoominlife9919 Жыл бұрын
Good evening ji Potential free kya Hota control circuit me So define it by video
@ttlstark22923 ай бұрын
Best
@BOLBULBULIndustrialElectrical3 ай бұрын
Thank you
@srijansingh983411 ай бұрын
Sir ye sb relay setting ek example ke sath samjhaiye na please .
@Satishkumar-Taneja2 ай бұрын
Good
@BOLBULBULIndustrialElectrical2 ай бұрын
Thank you
@abhishekchauhan3522 Жыл бұрын
Hi sir mere panel me 1 problem arha hai panel me 2 I/C 2 DG aur 2 tie breaker(BUS) hai jo auto me plc se operate hota hai sir mai jab 1no panel on kar raha hu to auto me 1no tie breaker on hoja raha hai but 2no tie breaker auto me on nahi ho rha hai jab ki plc command de raha hai breaker ke closing coil ko 239 vac supply a rha hai uv coil ko 239 vac a rha hai fir bhi on nahi ho raha hai aur manual me karke tnc se on hoja raha hai But 2no panel on kar raha hu to dono tie breaker auto me on hoja raha hai kya problem ho sakta hai sir plz bataiye
@BOLBULBULIndustrialElectrical Жыл бұрын
Tie breaker 2 ka closing coil ko supply mil raha hai to close hona chahie. Closing coil ka supply AC v hai ? Breaker control supply sahi se check kare .
@abhishekchauhan3522 Жыл бұрын
@@BOLBULBULIndustrialElectrical Thank you sir servicing Kiya to OK ho gaya sir
@BOLBULBULIndustrialElectrical Жыл бұрын
Welcome
@explorewithsrj_dp Жыл бұрын
Requirement ke wise humen 15 kw ka motor chahiye bt agar wahan hum high rating motor lyk 45 kw or more use kare then ye kya kya affect karega ... Except cost
@BOLBULBULIndustrialElectrical Жыл бұрын
Water Pump ke lie drive use karte hai to pump change karna padega. Pipe line change karna padega. Matlab jyada power ( Shakti ) hone se Jo problem ho sakta hai wohi hoga.
@explorewithsrj_dp Жыл бұрын
@@BOLBULBULIndustrialElectrical thnq sir
@BOLBULBULIndustrialElectrical Жыл бұрын
Welcome
@arjunthakur4762 Жыл бұрын
Vcb ka pt control wiring jal gaya hai control wire 11kv basbar😍se tuch ho gaya pura wiring fail ho gaya hai sir ji brekar troli ka 1 phase output aata nahi bhut hi bada fault hua hai ht capacitor fail ho gaya hai 😄😍😊😭🙏