"F3" error on split ac with an inverter due to the error of the exhaust pipe temperature in the outdoor. (outdoor thermistor sensor) there are 3 types of discharge pipe sensor, reverse pipe sensor, outdoor temperature sensor, of the three types of sensors that read the outdoor working temperature and provide a signal to the inverter module.
"F3" error can be caused by lack of freon, outdoor thermistor sensor is damaged / misread temperature, electronic expansion valve is broken, body valve expansion is broken, pcb inverter module is error / damaged.
Here I use a capillary pipe to replace the damaged valve expansion. Sy, don't recommend friends to replace it with capillary pipes, but so far there are no problems for its use, the AC still wants to cool at low, med, high comp speed.