Thank you. Hurricane is hitting us now but had gotten parts from hardware store. They told me to just find a how to video. This was very helpful.
@cornfields-crosshairs41823 жыл бұрын
Thanks!! It's almost 3:00 a.m. here in Michigan and I'm in a brown-out watching this with my tools and cord! Much appreciated! Clear instructions!
@abrahamochoa21614 жыл бұрын
Best video ever! Other videos skip this part (the one you are actually looking for). Great job.
@gusgstratton89774 жыл бұрын
Excellent step-by-step instructions. Very clear, concise and to the point.
@ericyoung19733 жыл бұрын
Thanks!! So many videos that DO NOT tell you what X or Y mean on the plug. I used ferrules on my stranded wire and it really makes the connections clean.
@keithmapes57584 жыл бұрын
The best video for making this cord i have found on KZbin.
@nkel61112 жыл бұрын
not funny...he needs to do closeups and ...well so much more
@chalemi4 жыл бұрын
Well hell yeah! This is exactly the plug and cord I bought at Lowes! Great instruction! Thanks!
@jamiehutchins25864 жыл бұрын
Two Thumbs Up! Excellent Presentation! Helped filled in the Blanks. Thanks!
@josephrruggiero12533 жыл бұрын
Great job explaining instructions. I have a 30 amp generator but a 20 amp transfer switch.I have a 30 amp extension. Can remove the 30 amp female connector and use a 20 amp female connector that would go into the transfer switch. Matching the wires to the x,y, g, w on the 20 amp connector ?
@jimbo24873 жыл бұрын
Outstanding, I’m headed to Lowe’s in the morning to get wire and plugs.
@pirihern93293 жыл бұрын
Just found this. Excellent video. Ordered a 40' cord but won't get here till wed. I'm in ct. Storm is coming fast. Need to go to Lowe's asap. Hope they have this.
@bobbrown19424 жыл бұрын
Craig Thanks for the great video! Really helpful 🌠🌠🌠 bob brown Melbourne florida
@stevesierko32344 жыл бұрын
Hi There thanks for the video. My current cord has a four prong that goes into that gen. and a 3 prong on the other end of the cord that goes into the plug attached to my sub-panel. I need a longer cable do the two hot wires go together on the the three prong end? Thanks Steve
@JoeSimple4 жыл бұрын
Hey Steve, NO DONT DO THAT. in my opinion, I'm going to guess that the cable that's being used only has 3 wires black/white/green. And is only useing 120v from the generator.
@barneyrubble48273 жыл бұрын
Not only would I not do what you suggested, I would swap out one of the plugs making both ends the same to prevent a potentially dangerous situation for the unaware.
@rezyl1026 жыл бұрын
I wonder if you could help me. I have a 4000W generator with a TT-30P outlet and I want to use a through-wall transfer kit with an L14-30R receptacle to pass electricity into my house. I have the RV plug, a length of 4-wire 10 gauge cord and the L14-30R adapter. When running the wires from the RV plug to the adapter, do I tie the two hots together at the plug so that I have all 4 wires at the adapter, or do I use only one hot and leave one unused? Thanks...
@craigmichaud-electricalins46026 жыл бұрын
Great question!! Most RV plugs are only rated for 125v. You will need to buy a 4 wire outlet in order to care the 240v load to the house. In my video on back feeding an electrical panel I explain how to do that. I hope this helps. Thanks for the question!! CM
@SI-lg2vp3 жыл бұрын
For an inverter generator that only supplies 120 volt power, how do you wire a power cord to feed an electrical panel? I also have a 240v 14KW diesel generator that correctly wired with a manual transfer but prefer to not to run when I don't need to. I have an RV outlet 240v 30amp I would like to use for the inverter generator. Can you jumper the X, Y connection to feed the panel with the panel isolated ( mains disconnected using the manual generator interlock). I'm only looking to power a gas furnace, refrigerator, and freezer during the night time.
@MrMickeysbee693 жыл бұрын
So can x and y be crossed or do they have to be on the same terminal at each end?
@0321recon3 жыл бұрын
did you get an answer, or figure it out? My question too.
@MrMickeysbee693 жыл бұрын
@@0321recon nope. I still don't know.
@0321recon3 жыл бұрын
@@MrMickeysbee69 I see in comments people referring to them needing to be same on each end, and Craig says in a comment it is common practice to us X for Black and Y for Red. Hope that helps.
@barneyrubble48273 жыл бұрын
In 220v single phase, X and Y are interchangeable as both are 110v hot... they are the same. Keeping both ends wired the same is still a good idea tho imo.
@bpleunik4 жыл бұрын
Great video thanks! I’m making one of these right now
@SharonMartinez3 жыл бұрын
Excellent video. Thank you. I have a 9500 Watt (starting) inverter generator that runs at 7600 Watts but all the cords that I see are at a maximum of 7500 Watts. Surely I am missing something. How do I find an adequate cord?
@dickeymoore73655 жыл бұрын
So you say the X and Y wires does not matter which side so do they have to be the same place on each ends of the plugs like the red in the Y and the black in the X on each end on the plugs?
@berniemac84134 жыл бұрын
No it doesn’t matter.. but you can keep it consistent if you’d like..
@dougbritt95055 жыл бұрын
On each connector (male and female) does it matter if the black wire connects to the "X" terminal and red wire connects to the "Y" terminal, as long as they match on both ends?
@craigmichaud-electricalins46025 жыл бұрын
That is correct. It is common practice to use (X) for Black and (Y) for red. CM
@Bluesman575 жыл бұрын
I am a licensed master electrician in Michigan, I just ran across your video's tonight, and I am enjoying them! In your previous video (how to hook up a generator in a power outage) you said X was red and Y was black, I know it doesn't matter as long as they are the same on both ends. Just wondering the difference in videos.
@RSole9999 Жыл бұрын
@@Bluesman57 Licensed electrician or not, you are wrong. The X and Y can be different at both ends, since the load won't be affected by it. Each leg will be 120V and 240V across both. With a single phase source it won't matter.
@JamesAmbrose48 Жыл бұрын
Hi. I just wired my first generator plug, male end only because the other end is going to wire directly into my inverter. I got 3 wire 10 AWG romex because that’s all I could find; red, white, black, and bare copper ground. The wires are solid instead of stranded and I wired them correctly into the plug. Will I have any issues with these modifications?
@dailystruggletv54034 жыл бұрын
thank you super helpful appreciate it ✌🏽
@joeoquendo49433 жыл бұрын
How do I make two male sides so that I can connect the generator to the house? Thanks.
@joshm33426 ай бұрын
Be sure to have your Life and Umbrella policies paid up. Oh, and a current will.
@joeoquendo49436 ай бұрын
Obviously you’ve never lived in a Hurricane saturated corridor. Local electricians do it all the time. Just make sure the main breaker is off as to not shock the power company workers.
@Pondybolk4 жыл бұрын
I just made mine. Excellent video. Thank you
@bigjoe42944 жыл бұрын
Could you demonstrate or explain making 4 wire cord to 3 wire connection? Thank you.
@walterbuller91714 жыл бұрын
You connect the ground and neutral wires together on the 3 prong end..
@phxgrindcoffee36342 жыл бұрын
I’m needing to make a male to go to my predator 9500 and my trailer which also is a male - this will work the same exact way correct? All these supplies at Home Depot?
@jvazquez535 жыл бұрын
Thank you! Very helpful!
@josephacavell77524 жыл бұрын
can you tell me what gauge wire i should use to make a 30ft 30 amp generator cable
@harryinoklahoma18663 жыл бұрын
10ga. will work fine for 30 feet.
@petermurphy66443 жыл бұрын
I changed my air compressor motor from 110 to 220. But it only has 3 wires, black white and ground. My receptacle on my portable generator is 4 wires (L14-20R). How do I wire an L14-20P with only 3 wires so I can run my compressor off my generator? Can I use the black and white as both hot and have no neutral?
@chalemi3 жыл бұрын
Ok lets say my 30A recepticle on my generator is a 3 prong interlock, how would I connect wires on a 3 prong male plug versus the 4 prong shown here?
@joshuabradshaw22013 жыл бұрын
Following been trying to find out the answer for almost a year and seems no one knows
@Affordablebath_remodel5 ай бұрын
they make an adapter to go from 3 to 4 wire. found it on amazon.
@nathanarunyan064 жыл бұрын
Can you wire L14-30 male end (connects to generator ) to a L6-20 female end on the same cord. ? Or do I need an adapter for that. Thank you.
@joshm33426 ай бұрын
One of the benefits of making your own cable is that you can have whichever connectors make sense electrically, eliminating points of resistance & heat. Adapters are OK in a pinch, but every plug-in connection is gonna have a bit more resistance than uninterrupted copper wire.
@joshuabradshaw22013 жыл бұрын
Would a 3 prong work reason I ask I have a outlet set up outside our house for our camper and everything I have set up is for 3 prong with no extra space for another breaker
@middlecrossranch39772 жыл бұрын
Are there any extension cord ends that are look good after they’re on your cord, like the factory ones?
@cmcc19715 жыл бұрын
My 4 prong doesn’t have a “W” but it does have a “Z”. It does have a G, X and a Y. Do I connect the red and black wires to the X and Y screws and the white wire to the Z? I already have the green wire connected to the G.
@barneyrubble48273 жыл бұрын
Yes, the Z replaces the W. X and Y are hot. G is ground so the Z can only be W.
@pourliver3 жыл бұрын
I have a question. I bought an oven cable (NEMA 15-50P), and attached a NEMA (15--30P) on the otherside for one of my device. I do not know the wiring on the 15-50p, so I cannot know if black or red is on x (or y). Is that something I need to worry about on the 15-30p side? I know you can interchange x and y if done on both sides, but is it OK if X on one end goes the Y on the other end, and vice versa?
@barneyrubble48273 жыл бұрын
In 220 single phase, the 2 hot wires are inter changeable. The device doesn't care bout the color of wire, only that it's getting 110v through X & Y. For continuity sake, i wire each plug the same way cause I feel more comfortable. If you were using one of these plugs to wire a 220v 3(industrial) phase with 3 hot leads and a neutral, it would most definitely matter that both,plugs were wired the same
@pourliver3 жыл бұрын
@@barneyrubble4827 Thanks a ton! I tried my cable and it works just fine now. From what I understand, as long as its single phase, hot cables can be interchanged, glad to know I didn't fuck up! :)
@Ojeramup123 жыл бұрын
I have aTHEORETICAL question. IF I turn OFF the main breaker from my house and then turn off every breaker in the panel and want to use a generator, can I plug in to an existing exterior receptacle from my generator. If the electricity is going to this receptacle would it power ONLY this breaker if I turned it on or can I turn on another breaker to use that breaker as well.I have a 2000watt generator and would only use maybe 1000-1500 watts total.
@barneyrubble48273 жыл бұрын
With the main panel switch turned off, connecting the Gen to a breaker will backfeed the whole panel with if using a 2 pole(220v) breaker or half the panel if using a single pole(110v) breaker. Doing this w/o a proper generator safety switch is very dangerous tho cause if by mistake somehow the main panel switch was accidentally turned on while Gen was actively backfeeding that breaker...VERY VERY BAD!!!! Also, if power employee is working to restore a line and main switch gets turned on, you could electrocute him. He thinks the line is dead but it's not.
@davidrivera86344 жыл бұрын
I have a 240 buffer that has 3 prongs. Every residence I go to now has 4 prong connections for the range and the dryer. What do I do in these situations?
@phenofarmsloot4matt3243 жыл бұрын
Would 10/3 (Orange Romex) work just the same? I understand you don’t want to use romex as an extension chord. I’m running it through liquid tuff conduit along the wall. Just wanted to confirm the wire it does would work just the same as the SJO
@Zues643 жыл бұрын
My Champion generator has a floating neutral with a 3-terminal 30-A outlet; not 4. Can you show how to wire a 3 vs 4 wire plug?
@2muchspl6 жыл бұрын
Great How To!!!! Simple and clear.
@andrew86-825 жыл бұрын
I have a generator panel with the proper plug but my generator only has regular plugs on it. Can I wire a regular plug to the 4 prong that is plugging into the house as long as I am only running 15-20 amps at a time...
@toro200615 жыл бұрын
Is it the same thing for 4 wires and 3 wire female? Thanks
@rocketrider14053 жыл бұрын
Why twist the stranded conductors ‘backward’ (CCW) ?
@joshm33426 ай бұрын
I look at the diection of wire twist after some insulation has been stripped off, and twist in the same direction. Keeps the strands tight and compact for best connection.
@mark1952able3 жыл бұрын
I have a 30amp 3 wire cord. Can I hook it up to a 4 prong male adapter?
@islammoselhi65004 жыл бұрын
Thanks for that, but I have s question pls, I need to make the extension cord like that ( one end has 3 pin of male and other end has 4 colors of female ) that's because I have a food trailer and the cable in the trailer ends with male 4 colors , but I cant plug in that 4 pins in my home as the home has 3 pin only ,so is that okay to have 4 colors cable one end is 4 pins female and other end 3 pin male ? I wish I made u understand me, thanks alot!
@DJIzzyDC4 жыл бұрын
What if i want to replace a regular home 220V outlet and put in a Generator type receptacle instead? what do i do with the neutral, cause as i understand you don't use neutral in a 220v receptacle, is that correct?
@jbbolts4 жыл бұрын
just skip it
@barneyrubble48273 жыл бұрын
If using 4 wire, twist the gnd and neutral together for use with 3 prong
@djnamek215phillysfinest23 жыл бұрын
Your video did help. Thank you
@brianhilligoss3 жыл бұрын
So what do I do if I need to go from the male twist lock that’s 240v and split it for 120v?
@genetemplet70223 жыл бұрын
Very good and to the point.
@murphymj3 жыл бұрын
Great video!
@6hcastro4 жыл бұрын
I have two 25ft 30amp 10g extension cords, can i connect both of them to make a 50ft. If i do will be loosing voltage? Or its better just to buy one extension cord of 50ft?
@barneyrubble48273 жыл бұрын
There should be no difference long as the connectors are in good condition.
@TheAwesomeHomestead6 жыл бұрын
my genny says i can use the NEMA locking cord as a 120 at 30 amps. how do i do that?
@danlevine25843 жыл бұрын
Craig? Here's my question. It seems that everyone wires a FEMALE out-let to their fuse box to plug-in their Generator. Here we have a Female out-let on the Generator. Here we have a Female outlet at the fuse box. To connect the generator to the fuse box will require a cord with two Male connectors. I had to wire a MALE connector to my breaker box to avoid cutting my brand new 10/4 Generator cable. Is it normal for your breakers to become warm considering we are now back feeding with a generator.
@antdrodz4 жыл бұрын
I have a 9500 running watts generator. Will this cable work for my house .
@jimcarney61154 жыл бұрын
30 amp connectors rated at 7500 watts at 250v. As long as your Gen has 30 amp outlet and you draw less than 7500 watts you'd be golden, but I'm no electrocutioner. ASK A PRO.
@barneyrubble48273 жыл бұрын
If you draw more than 7500 watts which you could, your cord could overheat rather than shutting down the generator, that is dangerous. Do it right man!
@mainewoods18624 жыл бұрын
Thank you excellent tutorial!
@mikes.18824 жыл бұрын
Electricians, Always gotta grab the biggest longest tool out of the bag 😆
@terryswails11913 жыл бұрын
Big tools= status symbol.
@pharpester3 жыл бұрын
How would you make a 50a twist lock cord
@cllim804 жыл бұрын
May I know would it be OK to make a backfeed 150-200 feet length of 30 Amp cord by using your method ?
@josephpuchel64974 жыл бұрын
Hey Read your question what did you end up doing ? Thicker gauge wire ? What’s the distance of wire did you make? Thank you
@cllim804 жыл бұрын
@@josephpuchel6497 At the end, I went to Amz and bought two long cables and connected them together.
@barneyrubble48273 жыл бұрын
Long runs will have some loss and possibly heat if too long. Heavier GA would prevent that. There are charts for this calculation.
@randylee25494 жыл бұрын
is this cheaper than a pre moulded one?
@bigpardner4 жыл бұрын
Probably not. I see at Home Depot the cord is 2.45 a foot, which is more than a ready made cord, at least for a 25 foot one. $61.25 just for the cord alone.
@yellow_panther3 жыл бұрын
@@bigpardner I think the HD wire is more flexible in colder weather than the pre-made cords I am finding (SJO vs SJTW)
@seanryan27404 жыл бұрын
Would this cord be safe to use in the rain?
@barneyrubble48273 жыл бұрын
Def Not!! in emergency, raise connection higher than the cable(off the gnd) and cover with waterproof housing FOR EMERGENCIES ONLY!!
@tammyburris39936 жыл бұрын
Nice work
@waynejump32633 жыл бұрын
is it ok to make a 100' cord?
@wilh.74855 жыл бұрын
An you help, I am going from a 4 wire generator to a 3 wire dryer connection. Do eliminate the ground or do I connect the ground and the neutral together
@craigmichaud-electricalins46025 жыл бұрын
In a jam either way should work!!
@Mazel_Tov_8884 жыл бұрын
instead of using that finger slicer, use diangular plier starting at the end of the cable to cut back insulation.
@jimgresham55294 жыл бұрын
Explain please "Diangular plier". wtf
@tommiekeen23144 жыл бұрын
What gauge is the wire need to be?
@fredwild1903 жыл бұрын
See notes at the top. He used 10 gauge, 4 wire cable.
@freelancellc5 жыл бұрын
good I'm getting about a 28.6% conversion rate on each test I do with a Power Lead Generator funnel.
@nkgaming45085 жыл бұрын
PLEASE HELP ME: I put X on Red and Y black is that correct?
@Inariusclaimedthethrone5 жыл бұрын
NK GAMING should be as long as you did that on both sides of the cord
@mikeshotglass51196 жыл бұрын
How much did this cost to make?
@craigmichaud-electricalins46026 жыл бұрын
About $40.00. It depends on the wire size and how long you want it to be. I use 10AWG for anything under 10 feet. at 30 amps. If you need it longer then you can use 8AWG. Bigger is always better!! Thanks for watching. CM
@ryannastaj5 жыл бұрын
Craig, did you find this a "better" option than buying one at big box? What did you choose to make vs buy prefabricated?
@fredwild1903 жыл бұрын
@@craigmichaud-electricalins4602 Bigger is better IF the connector will take the larger gauge wire. For example, #6AWG wire is too big for a typical 30 amp connector.
@tsi87supr604 жыл бұрын
Now do a 4 prong 240v to 120v for generator use.
@mark1952able3 жыл бұрын
When there is 4 wires on the cord and a 4 prong adapter, it's pretty self explanatory.
@CarlosCastro-bz8nc4 жыл бұрын
Subtítulos en español por favor
@drublod5304 жыл бұрын
Isn’t that a 50 amp cord? I thought 50 amp were 4 prong and 30 amp is 3 prong. You made a 50 amp cord NOT 30 amps!!
@craigmichaud-electricalins46024 жыл бұрын
The prongs have NOTHING to do with AMPS. It is wire size , and 10AWG is rated for 30 Amps. Not sure who or where you were told prongs dictates amps but you may want to let them know so someone does not get hurt. CM
@drublod5304 жыл бұрын
Craig Michaud- Electrical Instructor Nonsense, plugs were designed to dictate amps so stupid people wouldn’t plug the wrong amp cord into the wrong socket. Really? I shouldn’t have to tell an electrician this!
@billconnell86884 жыл бұрын
@@drublod530 Unfortunately that is not true. My 30 amp, 40 amp and 50 amp outlets installed by a major electrical contractor here in San Diego use the exact same receptacle. Only the wire size going from the receptacle to the panels circuit breakers were different. 30 amp for my genny was 10awg, the 40amp for my electric car was 8 awg and the 50 amp for my welder was 6 awg (he said that was actually rated for 55 amp.
@barneyrubble48273 жыл бұрын
@@drublod530 a little bit of knowledge can be dangerous! You are right bout the plugs but there is flexibility within each design. You should make sure of yourself b4 you go blasting people.