Manual pemrograman ATS48 menggunakan display terminal

  Рет қаралды 10,675

CCC Technical Support Engineer

CCC Technical Support Engineer

Күн бұрын

Пікірлер: 16
@azmanzakaria9687
@azmanzakaria9687 3 жыл бұрын
salam kenal...saya dari malaysia yg terbiasa guna altstt 22...
@wahidsuryaachmadi8086
@wahidsuryaachmadi8086 2 жыл бұрын
Pak mau tanya untuk bypass kontaktor itu klau kita pasang dia langsung aux kontak lngsung berubahh ya pak
@akhmadsofii47
@akhmadsofii47 2 жыл бұрын
sy punya kasus pd altistart .....troblenya klo start awal motor langsung ginjal2...trip. mohon solusi ya...
@muhammadfurkoni839
@muhammadfurkoni839 2 жыл бұрын
Bang mau nanya di monitor udah ready tapi belum bisa run. Sama CL1 dan CL2 itu input phase ya Terimakasih
@fjpnababan8432
@fjpnababan8432 3 жыл бұрын
Bang mau tanya, kenapa inverter display nya NLp. Untuk inverter altivar 320 Mohon pencerahannya bang 🙏
@sumarsonosumarsono
@sumarsonosumarsono 3 жыл бұрын
Hello Pak @fjp Nababan. Error "NLP" bisa terjadi karena salah satu phase ada yang hilang. Pastikan tegangan RST masuk dan bisa terukur dengan normal Pak. Jika RST normal, coba Bapak ukur tegangan CD Bus-nya. DC bus terminals (PA/+ and PC/-). Normal tegangan DC bus bisa > 400 VDC. Apabila tegangan-nya kecil sekali < 100 VDC, ada kemungkinan power board bermasalah.
@badriyahbadriyah8087
@badriyahbadriyah8087 2 жыл бұрын
Pak maaf saya punyak kasus Ats 48 saya KL distar alarm PHF padahal yang saya pakek panel posisi jalan normal awalnya Ats 48 layar mati setelah saya bersihkan jd nyala tp kl dicoba alarm PHF mohon bantuannya
@sumarsonosumarsono
@sumarsonosumarsono 2 жыл бұрын
Pak @Badriyah Badriyah pangapunten baru bisa membalas pertanyaan dari Bapak. Alarm PHF ini ada kaitan dengan phase lose. Biasa input supply ada salah satu yang hilang pasa Pak. Atau ada masalah di sisi bagian beban atau ouput Pak. Untuk detailnya kami persilahkan Bapak untuk contact hotline Schneider kami di : 1500055 atau chat ke team kami Pak. ( www.se.com/id/en/work/support/customer-care/contact-schneider-electric.jsp ). team kami akan membantu kebutuhan dari Bapak.
@indrajayadi6173
@indrajayadi6173 4 жыл бұрын
Kalo tanpa load motor, untuk test control bisakah?
@rxchester3364
@rxchester3364 5 жыл бұрын
Bang kalo r3a-r3c sy jadikan isolating contactor/fault relay bisa ga?
@technicalsupportengineerin9706
@technicalsupportengineerin9706 5 жыл бұрын
Salam Pak Rx Chester, mohon maaf telat me-response Pak. Pada dasarnya fungsi isolating / fault itu hanya ada pada fungsi relay R1. R3 umumnya difungsikan untuk motor thermal, powered, current, underload and PTC alarm. Thanks.
@rxchester3364
@rxchester3364 5 жыл бұрын
@@technicalsupportengineerin9706 owh ok siap bang 😁👍
@ruwesraymundus9977
@ruwesraymundus9977 4 жыл бұрын
Mas r2a & r2c itu untuk bypass kontaktor maksutnya gmn mas?
@rialitalinanjar1157
@rialitalinanjar1157 6 жыл бұрын
Minta no wa dong bang?
@sumarsonosumarsono
@sumarsonosumarsono 6 жыл бұрын
Mohon langsung ke call center saja ya Pak. Ke hotline : 1500055. Team kami akan support kebutuhan dari Bapak. Thanks.
How to Substitute an ATS48 with an ATS480 | Schneider Electric Support
7:05
ATS48C41Q PANEL CONTROL 400V
18:56
BREAKER TV
Рет қаралды 1 М.
Я сделала самое маленькое в мире мороженое!
00:43
Кушать Хочу
Рет қаралды 4,3 МЛН
Это было очень близко...
00:10
Аришнев
Рет қаралды 2,3 МЛН
This mother's baby is too unreliable.
00:13
FUNNY XIAOTING 666
Рет қаралды 38 МЛН
Understanding the StF Error on Altistart ATS48 | Schneider Electric Support
5:15
برمجه سوفت ستارت شنايدر altistart48محاضرة 1
20:58
ENG.MOHAMED FANDOD (EGYPTIAN ENGINEER)
Рет қаралды 10 М.
Setting PID pada ATV312
8:58
CCC Technical Support Engineer
Рет қаралды 9 М.
Penjelasan Soft Starter ATS48 saat Mentor P5M by ican
17:41
Caklegmelbourne
Рет қаралды 5 М.
Basic Setting PM5560
6:17
CCC Technical Support Engineer
Рет қаралды 11 М.
شرح برمجة سوفت ستارتر شنايدر 110 kw
17:43
خليل أبو سرمد
Рет қаралды 24 М.
Я сделала самое маленькое в мире мороженое!
00:43
Кушать Хочу
Рет қаралды 4,3 МЛН