Mitsubishi Ecodan Air Source Heat Pumps

  Рет қаралды 90,038

Dore Woodman

Dore Woodman

Күн бұрын

Пікірлер: 36
@DEPHECTDJ
@DEPHECTDJ Жыл бұрын
Hi mate. Lovely video. Ps that prv in the outdoor unit is for the hydronic side.
@dorewoodman
@dorewoodman Жыл бұрын
Thanks, yes I did realise that. I think it’s time for a upgrade on this anyhow
@terryrigden4860
@terryrigden4860 Жыл бұрын
Thanks for the info. Do you have a video showing how I could adjust the weather compensation
@hasnat9
@hasnat9 Жыл бұрын
I’m looking to buy a flat in a block that has 20 of these on the roof directly above my flat. Do you reckon this would create a lot of noise and vibration being so close to them?
@danbramill8410
@danbramill8410 2 жыл бұрын
Hi there, you can turn the main pump speed down, in most cases to minimum, it’s a 15 meter head pump and they come set to max as standard, also you can adjust your legionella program to min.
@jeffn9316
@jeffn9316 3 жыл бұрын
Many thanks for all your interesting and informative videos. In this one you mentioned the latest Ecodan FTC6 controller. I believe this now has a function called Quiet Mode, but I haven't nanaged to find any info about it and what you can do with it. Any info at all would be greatly appreciated. Thank you 🙂
@dorewoodman
@dorewoodman 3 жыл бұрын
Hi Jeff, I will look to add this as a video for you to look at
@jeffn9316
@jeffn9316 3 жыл бұрын
@@dorewoodman That would be great. Thanks very much for your help 🙂
@nareshgp
@nareshgp Жыл бұрын
Thanks for this great video. I'm at a point of ordering a heat pump and everyone keeps telling me to use a buffer tank, whatever brand I buy. 1 Mitsubishi guy said it's not needed and I was confused. So i can safely buy the 11.2kW without buffer tank ?
@malinka511km
@malinka511km Жыл бұрын
Which one is better mitsubishi ecodan or vaillant arotherm plus?
@dorewoodman
@dorewoodman Жыл бұрын
Hi, It depends on the property you are installing into and the total heat loss of the house. The Vaillant has the R290 refrigerant which all manufacturers are now heading towards whereas the Mitsubishi Ecodan is using R32.
@jamesanderson6405
@jamesanderson6405 3 жыл бұрын
I have this system for the last 10 years mine is the suba dancing fan have not had many problems in that time replaced a fan couple of times does not seem to be switching over now from heating to water the zones all seem to be in the locked position water and heating on together
@dorewoodman
@dorewoodman 3 жыл бұрын
Hi James, Thank you for the comment. Do you have the Mitsubishi Pre Plumbed Cylinder? It sounds as though the diverter valve is stuck in a central position as it should only activate as just hot water or heating, never both. It could be caused by a worn out components or debris/deposits in the system that have caused it to wedge open or the actuator motor/solenoid has failed inside the diverter valve. Many thanks, Dore Woodman Ltd
@jamesanderson6405
@jamesanderson6405 3 жыл бұрын
@@dorewoodman what is pre plumed cylinder I have 300 litre tank 18 radiators there is 3 zones on it all was in locked position was getting no hot water so I forced it back which allowed the hot water in to the tank
@dorewoodman
@dorewoodman 3 жыл бұрын
@@jamesanderson6405 The pre plumb cylinder is featured in this video. You may well have a 3rd party cylinder (different manufacturer) and a Honeywell V4044C diverter valve. Get it checked, likely to just need a new motorised part, you should be able to just change the Head.
@whiteboyrick1588
@whiteboyrick1588 3 жыл бұрын
@Dore Woodman What is the maximum length of exterior hose. What is best practice for the hot and cold inlets?
@whiteboyrick1588
@whiteboyrick1588 3 жыл бұрын
In terms on length of hose?
@pmbpmb5416
@pmbpmb5416 2 жыл бұрын
I am reading that ecodans defrost cycle is set to come on when 5 degrees is reached , this seems excessive given the fluid in the system and that in the UK five is achieved often but it’s not freezing point or close , can it be altered to lower ?
@jasongittoes7299
@jasongittoes7299 3 жыл бұрын
Any chance of a diagram of the connection from the pump to the cylinder including a buffa tank ?
@dorewoodman
@dorewoodman 3 жыл бұрын
Hi Jason, I don't have a schematic as such but a Buffer could be Tee'd in before or after the Low Loss Header on the pre plumbed cylinder. It may not necessarily require a buffer on the system at all though, for example, the minimum water capacity in the heating system for the 8.5 kw Ecodan is just 12 litres and the 16 litres for the 11.2 kw. This will allow the heat pump to deal with the defrost cycle and keep them within the recommended cycles per hour.
@Powertoyah32
@Powertoyah32 2 жыл бұрын
Hi Jason I have 8.5kw ecodan with underfloor downstairs and rads upstairs, each zone downstairs has its own heatmiser room stats and a nest stat for upstairs, I have a cop of 2.3 on average, what would be the best way of setting it up? At the moment I removed the actuators on the manifold to keep the flow rate up and set the main controller which is in the hallway as the main stat.
@davidreece1642
@davidreece1642 2 жыл бұрын
Is the Mixergy smart cylinder compatible with the Mit'si ASHP ?
@sullydee2237
@sullydee2237 2 жыл бұрын
can this unit heat radent floor to 70deg. 3500 sqft house in 30 deg, outside without heat strips and keep floors that temp without heat strips when it gets colder outside
@acdiversitychannel3024
@acdiversitychannel3024 2 жыл бұрын
I have one of those identical system in my home, I have come accross a code error L9, any suggestions in what i can do to fix that? i have tried multiple resets but no joy... thanks in advance
@dorewoodman
@dorewoodman 2 жыл бұрын
It is due to a low flow rate, this can be caused by a blockage or an under performing pump on the main primaries between the cylinder and the heat pump so check the Y strainer (if one installed)
@acdiversitychannel3024
@acdiversitychannel3024 2 жыл бұрын
@@dorewoodman thank you for the reply
@seanorourke8470
@seanorourke8470 2 жыл бұрын
Well done mate,a very comprehensive video I had lot's of questions you covered them all👍, sorry just one question since it may not need a buffer tank dose it use an inverter generator heat pump
@dorewoodman
@dorewoodman 2 жыл бұрын
Hi Sean, thank you for your comment. It is inverter driven and will modulate to suit. The defrost cycle only requires a relatively low quantity of water compared to other heat pumps. If you install a 3rd party cylinder you may want to consider a low loss header to help with the hydraulics, flow rates etc.
@kaloyankisyov
@kaloyankisyov 2 жыл бұрын
Hello, I have heat pump its model is mitsubishi ecodan 8.5 kw puhz-w85vaa-bs. I am not using DHW only for heating and I don’t have water flow sensor, but when I start the heat pump, error code EE appears. Please help to solve this problem.
@dorewoodman
@dorewoodman 2 жыл бұрын
Hi, is this a new installation and would you happen to know if you have the FTC 5 or FTC 6 with this model?
@kaloyankisyov
@kaloyankisyov 2 жыл бұрын
@@dorewoodman Yes it's new installation with FTC 6 and heat pump is puz wm85vaa bs
@BKutube
@BKutube 2 жыл бұрын
how much for the full 5kw system
@dorewoodman
@dorewoodman 2 жыл бұрын
Hi B K, it really depends on the application, there are so many variables to consider depending on the property, age, heating emitters, heat pump placement etc. The cost could be anything in the region of £11k - £14k less the Boiler Upgrade Scheme voucher @ £5k if you are based in the UK.
@امیربردیایی
@امیربردیایی 3 жыл бұрын
نالملتل
@charlieritchie5980
@charlieritchie5980 2 жыл бұрын
DON'T fit a heat pump
@Gazmaz
@Gazmaz 2 жыл бұрын
Why?
Mitsubishi Ecodan Weather Compensation Adjustment
5:40
Mark Sawyer
Рет қаралды 34 М.
The Truth about Heat Pumps: Debunking the Myth.
12:28
Urban Plumbers
Рет қаралды 368 М.
coco在求救? #小丑 #天使 #shorts
00:29
好人小丑
Рет қаралды 120 МЛН
Каха и дочка
00:28
К-Media
Рет қаралды 3,4 МЛН
How Strong Is Tape?
00:24
Stokes Twins
Рет қаралды 96 МЛН
UFC 310 : Рахмонов VS Мачадо Гэрри
05:00
Setanta Sports UFC
Рет қаралды 1,2 МЛН
Mitsubishi Ecodan Pump Speed and Flow Rate
2:41
Mark Sawyer
Рет қаралды 18 М.
Delta T, temperature difference (dt) with heat pumps and boilers
16:28
Heat Pumps Explained - How Heat Pumps Work HVAC
9:43
The Engineering Mindset
Рет қаралды 2,4 МЛН
Mitsubishi Ecodan 14Kw Air Source Heat Pump review
9:22
Green Tubers
Рет қаралды 35 М.
Mitsubishi intelli-HEAT Dual Fuel Heat Pump System
9:04
Franco Barbagallo
Рет қаралды 281
Compensation curve Mitsubishi Ecodan Explained
5:01
Enviro heating Ltd
Рет қаралды 34 М.
Ecodan outdoor unit servicing
2:48
Mitsubishi Electric - Living Environmental Systems (UK)
Рет қаралды 26 М.
Setting heating / hotwater timer Mitsubishi Ecodan Air source.
4:06
Enviro heating Ltd
Рет қаралды 46 М.
How to Kill a Heat Pump's Efficiency!
25:52
Elite - Supporting a sustainable future
Рет қаралды 36 М.
coco在求救? #小丑 #天使 #shorts
00:29
好人小丑
Рет қаралды 120 МЛН