Dear All, There is confusion regarding the water-cement ratio. So kindly follow the below steps The water-cement ratio is 0.45 only pls check step no.2. So we need to add 0.01 one time in step no.5. It was an error in step no.5, (0.45 -0.4= 0.05) instead of (0.5-0.45 = 0.05). Kindly ignore that and follow the water-cement ratio of 0.45 as in step no.2. Thank you.
@ramakuchimanchi756110 ай бұрын
Here, the value is +0.05 so, we have to decrease (-0.01) that's it or else we have to increase +0.01
@anuragsingh-os3qs2 жыл бұрын
Very informative and it's very crisp and Cristal clear. Thank you madam 🙏 Keep enhancing our knowledge.
@CivilEngineeringMastery2 жыл бұрын
It's my pleasure
@learningofenglishgrammar82952 жыл бұрын
your explanation is very good and valuable for me ... thank you madam for sharing your knowledge...
@ramadevid42767 ай бұрын
Very clearly explained where you have picked the data from and justified. Thankyou madam.
@satyamkumar1992youtube Жыл бұрын
Very nice mam. U explained very well...
@georgekiadii45 Жыл бұрын
Whoa...! Very instructive. Many thanks.
@CivilEngineeringMastery11 ай бұрын
Glad it was helpful!
@ManiKandan-tg3di Жыл бұрын
Thank you 🙏🙏🙏 mam.....i really learned.. thanks for your valuable content ❤❤
@CivilEngineeringMastery Жыл бұрын
Glad to hear that
@SunkariSai Жыл бұрын
Nice explanation ❤❤
@manikantaarangi83772 жыл бұрын
Super explanation 🙏
@satyamkumar1992youtube Жыл бұрын
Here w/c is 0.5 for which h c.agg should be inc by 2×0.01
@akruthidhyaga744 Жыл бұрын
Nice explaination ,Thank you so much ma'am❤
@CHANDANKUMAR-lc1es Жыл бұрын
Superb & easy way of explaining the topic, thank u ma'am 🙏🙏
@VasudevJangid-f1d8 күн бұрын
very important lession
@rakeshbhandari88662 жыл бұрын
Nicely explained, thanks
@CivilEngineeringMastery2 жыл бұрын
Glad it was helpful!
@20-gopaljha34Ай бұрын
Agar slump 120 mm ho tu water content kasa niklna hai bilkul accurate ya tu pta chal gya every 25 mm slump 3 percent increase karta hai par 120 mm , 170 mm kasa niklna hai
@santoshkumarbabar72153 жыл бұрын
Good insights Thanks 🙏
@milindbute52592 ай бұрын
Nice video madam,i would like to suggest you to kindly deduct the air entrapped percentage from unit volume on concrete as per IS table 3 for appropriate air entrapped for 20mm aggregate
@CivilEngineeringMastery2 ай бұрын
Thanks for the suggestion, I'll definitely consider it for future videos!
@thegreenstick799 ай бұрын
Very Good explaination
@ajeetmakedesigner594 ай бұрын
Wow very nice mam 😊
@CivilEngineeringMastery4 ай бұрын
Thanks and welcome
@shankarrao45832 жыл бұрын
Good Explained madam
@nikhilnaik930311 ай бұрын
The ultimate best explaination
@eslavathvishnu52082 жыл бұрын
Thank you very much madam ...
@CivilEngineeringMastery2 жыл бұрын
Welcome!
@ankitdhatrak45 Жыл бұрын
Dhanyawad kaku
@sarthakk59168 ай бұрын
😂
@rajachandranraja8639 Жыл бұрын
We use the fly ash... how to calculate water content...
@tejaeswar.veeramsetti57059 ай бұрын
Good explanation...TQ madam
@CivilEngineeringMastery9 ай бұрын
Welcome 😊
@kingchola6032 жыл бұрын
அருமை
@mohanbabupm57782 жыл бұрын
Good expln
@smartboyvenky9527 Жыл бұрын
Can I use some percentage of glass powder or fly ash as a replacement of cement content??..Will I get the strength if I replace the cement??.... please tell me
@nikhilnaik930311 ай бұрын
Glass fibers shall be a good idea
@surajnishad683126 күн бұрын
Good 🎉
@rfbp9104 Жыл бұрын
Dear mam, kindly make a video of SCC concrete design mix process.
@BhagavanRam-r7v4 ай бұрын
Very nice
@AnandRaj-rd4sb2 жыл бұрын
How to design all the designated grades with filler like fly ash and ggbs also can you please upload mam
@munawarsyed7834 Жыл бұрын
Design a M30 grade concrete mix having a slump of 50-75mm for a structure likely to be subjected to extreme exposure conditions during its service life. The aggregates available is well shaped having a nominal size of aggregate of 20mm. specific gravity of 2.62 bulk density of 1540 kg/m3, moisture content = 1.0 percent and absorption = 0.5 percent, whereas the aggregates to be used has fineness modulus of 2.40, specific gravity 2.52. bulk density 1625 kg/m3, moisture content = 5 percent, absorption 0.6 percent. The available Portland cement has specific gravity of 3.14 Use IS method of mix design for mix proportioning to estimate mix proportions.
@ii_AniMixPlay_ii2 жыл бұрын
Thanks mam it’s very useful
@CivilEngineeringMastery2 жыл бұрын
Welcome 😊
@diyadeb Жыл бұрын
Mam in every numerical you subtracted 0.5-0.4 but in this case in the step 5 why you minus 0.45 to 0.4
@user-ui3zz5fb8n4 ай бұрын
Because in step 2). our water cement ratio was 0.45 and we have reduced it to .40
@RishabhR43 ай бұрын
Why should we reduce it? Can you pls mention in which cases we should do that and is it 0.05 which will be subtracted from the given info?
@Velhalla-vinod25 күн бұрын
Please make a disgine of ggbs and flyash and microfine 4 blend mix disgine
@shaikhzaid98232 жыл бұрын
Good vedioo mam ek question tha agar hm cement km krte hai to w/c kaise manage krege please suggestions mam
@nikilbadgaiyan53592 жыл бұрын
How we adjust water absorb by aggregate.
@sakshisali6330 Жыл бұрын
Mam if in question they also given the air content so what to do
@ptsports25292 жыл бұрын
Good
@suheelbhat593910 ай бұрын
Can I get this PDF
@arpannaskar63852 жыл бұрын
Nice video. Please send us other informative videos.
@CivilEngineeringMastery2 жыл бұрын
Sure 👍
@newaction65063 жыл бұрын
Many thank teacher! And dow can I get this code book?
@CivilEngineeringMastery3 жыл бұрын
You can download from google.
@venkatesharramshetti45956 ай бұрын
The final ratio we got is for weights right. ie 1kg of cement 2kg of fine aggegate....and so on
@mabraty88372 жыл бұрын
Hi, May you tell me What is this ratio ? this is ratio of mass or ratio of volume? For example M15 1:2:4
@Rjverma15504 ай бұрын
10mm aggregate ratio kese nikale please answer the question ❓
@navamhetre5933 Жыл бұрын
How to get the zone selection ???
@civilengineers2006 Жыл бұрын
Thank you mam ek video Hindi language me bna dijiye please ❤
@rarajahaj81143 жыл бұрын
Super plastisizer mam Apne kitna use kiya
@CivilEngineeringMastery3 жыл бұрын
1.1% of cement.
@engrjo51192 жыл бұрын
Good evening, where to download the tables reference being mentioned in the ACI method. Thank you
@CivilEngineeringMastery2 жыл бұрын
It is Indian Standard(IS) code.
@josephmogwira5945Ай бұрын
I need that book you are using madam PDF please
@moeedahmed41803 жыл бұрын
Thank u soo much mam
@CivilEngineeringMastery3 жыл бұрын
Most welcome 😊
@banavathvenkatesh63573 жыл бұрын
Mam after using admixture w/c ratio will be 0.4. Then in step no.5 i.e. aggregate proportion step you added 0.01 one time only. Actually from 0.5 to 0.4 it is need to add 0.01, 2 times. Am i correct? Or any understanding mistake? Waiting for your reply mam.
@CivilEngineeringMastery3 жыл бұрын
No. The water-cement ratio is 0.45 only pls check step no.2. So we need to add 0.01 one time only. It was an error in step no.5 (w/c -0.5). Kindly ignore that and follow the water-cement ratio of 0.45 as in step no.2.
@vinayvandale65082 жыл бұрын
@@CivilEngineeringMastery But for calculating cement content you used water-cement ratio as 0.4
@santhoshcivil3316 Жыл бұрын
@@CivilEngineeringMastery Which water cement ratio we have to consider mam..
@SaisowmyaGera Жыл бұрын
Madam once check the value of volume of coarse aggregate 0.549 is not correct madam 0.567 is correct
@janeet842 жыл бұрын
Thankyou so much you are wonderful
@CHANDANKUMAR-lc1es Жыл бұрын
Hello ma'am At 12.40 moment there is mistake ,the calculated W/C ratio is .4 but u use the .45 thereby ur calculated value of volm of C.A is wrong & also next value is errorful , so please justify the mistake .
@CivilEngineeringMastery Жыл бұрын
The water-cement ratio is 0.45 only pls check step no.2. So we need to add 0.01 one time in step no.5. It was an error in step no.5, (0.45 -0.4= 0.05) instead of (0.5-0.45 = 0.05). Kindly ignore that and follow the water-cement ratio of 0.45 as in step no.2.
@RishabhR43 ай бұрын
So ma'am there is no need to subtract 0.05 from water cement ratio ?(which you did in step no 2 ), and if we have to subtract can u please explain why we should do that Thank you
@saleempasha97632 жыл бұрын
For Moderate environmental exposure condition how much w/c ratio has to be taken ma'am...
@lalith47312 жыл бұрын
For m 35 and m40?
@suthishindia88653 жыл бұрын
How to take Mass of admixture 1.1% of cement
@balajibalu25582 жыл бұрын
Assumption 1.1%
@Allinone-hf5uu2 ай бұрын
Every one say previous video in description box .....but nothing in it......
@CivilEngineeringMastery2 ай бұрын
Thanks for pointing this out! It is updated please check.
@marirjpm93472 жыл бұрын
Thank you ji
@CivilEngineeringMastery2 жыл бұрын
Welcome
@chetanchaluvadhichetan2336 ай бұрын
W/C RATIO 0.5 but you taken 0.4..?
@mdahmadraza92782 жыл бұрын
Mam, how to calculate for 7 days .
@msrinivasakannan2 жыл бұрын
Coarse aggregate volume need to be checked again... Pls
@DevanshSanghvi-zk6cm Жыл бұрын
Ya its wrong - correct value is 0.567
@kbhargav85172 жыл бұрын
Mam I love u 💗 💓 💛 ❤ 💖 💕 💗 💓 💛 mam I've understand
@zamanzaman46673 жыл бұрын
please this vedio again upload because shighting probleme, like smoky
@ragnesh39793 жыл бұрын
Ma'am can I have pdf of this problem ..I feel happy on ur reply ..
@CivilEngineeringMastery3 жыл бұрын
Send an email to civilengineeringmastery@gmail.com
@mamata84962 жыл бұрын
Thank you kaise 10 MM and 20MM ka proportion find out kare
@avnish9935Ай бұрын
🙏
@rajnikant_official_00742 жыл бұрын
Do you have a link of this is code pdf
@a.amirdhasudhan55034 ай бұрын
Why don't you include the Air content
@ManiKrishna-qc2my Жыл бұрын
Why is 1000 is taken mam every time calculating mix calculation
@godwinchristgodwinchrist20413 ай бұрын
Ma'am pls I want take to you
@tesfayeahmed86992 жыл бұрын
You dont have any pecheny you are too fast how can lessan to bad