Morley IAS DXC Panel Commissioning | Fully Practical | Autolearn | DX CONNEXION | By Ansari29

  Рет қаралды 29,661

Ansari29

Ansari29

Күн бұрын

In this video, you can learn how to do commissioning of Morley IAS DXC panel.This video is important for project & service engineer who is working in fire & safety industry. This video is also useful for those person who are working in facility & operation industry.
If you are first time watch my channel so I request you to please first visit my channel videos & if you like my videos then only subscribe to my channel & also write comments if you want such valuable information.
__________________________________________________________________________
You can also join us on our facebook page, link available below.
/ ansari2991
__________________________________________________________________________
Must watch my previous video for more knowledge
---Interview Question & Answer On Fire Suppression System | Part-3 | FM200 | NOVEC | By Ansari29
• Interview Question & A...
---Interview Question & Answer in Fire Alarm System | Part-2 | By Ansari29
• Interview Question & A...
---Interview Question & Answer in Fire Alarm System | Part-1 | By Ansari29
• Interview Question & A...
---Faults & Troubleshooting in Addressable Fire Alarm System | Types of Faults | In Hindi | By Ansari29
• Faults & Troubleshooti...
---Ground Fault in Addressable Fire Alarm System | Causes & Troubleshooting | Easy to identify | Hindi
• Ground Fault in Addres...
---Addressable Fire Alarm System | How its Work | Type of Addressing | Module Integration | In Hindi
• Addressable Fire Alarm...
---Builder Integration In Addressable Fire Alarm System By Using Control & Monitor Module | Ansari29
• Builder Integration In...
---Monitor Module & How its Work | Fire Alarm Integration | Flow Switch, WLD, EDR, VESDA Integration
• Monitor Module & How i...
---Control / Relay Module in Addressable Fire Alarm System | Module Integration | CRF300,ULMCOM,MI-DCMO
• Control Module in Addr...
-----------------------------------------------------------------------------------------------------------------------Morley IAS DXC-1, Morley IAS DXC-2, Morley IAS DXC-3, Morley IAS DXC-4,
Honeywell fire alarm commissioning,fire alarm system commissioning,fire alarm testing and commissioning,commissioning in hindi,fire alarm testing,testing and commissioning of fire alarm system,fire alarm,fire alarm installation,fire alarm system testing,fire alarm system working principle,fire alarm system in hindi,how fire alarm system works,fire alarm system,fire alarm system installation,how to program a fire alartm panel,how to do fire alarm system installation
fire alarm panel,conventional fire alarm system,designing of fire alarm system in hindi,conventional fire alarm system in hindi,fault & troubleshooting in fire alarm system,फायर अलार्म सिस्टम में दोष और समस्या निवारण,open circuit fault in fire alarm system,battery fault in fire alarm system,AC supply fault in fire alarm system,fire,smoke detector,MCP,heat detector,troubleshooting,fault,addressable fire alarm system wiring,addressable fire alarm system installation,addressable fire alarm system installation in hindi,addressable fire alarm system tutorial,addressable fire alarm advantages,addressable fire alarm system cabling,addressable fire alarm system diagram,fire alarm addressable system wiring diagram,addressable fire alarm system explained,how addressable fire alarm system works,addressable fire alarm system loop,fire alarm system addressable type,addressable fire alarm system wiring,
addressable fire alarm system installation,
addressable fire alarm system installation in hindi,
addressable fire alarm system manufacturers in india,
bosch addressable fire alarm system,
addressable fire alarm system communication protocol,
addressable fire alarm system components,
addressable fire alarm system cabling,
conventional and addressable fire alarm system,
conventional vs addressable fire alarm system,
addressable fire alarm system diagram,
addressable fire alarm system design,
fire alarm addressable system wiring diagram,
addressable fire alarm panel,
addressable fire alarm system explained,
addressable fire alarm system honeywell,
how addressable fire alarm system works,
honeywell addressable fire alarm system wiring diagram,
addressable fire alarm system india,
addressable fire alarm system installation guide,
addressable fire alarm system loop,
addressable fire alarm system manufacturers,
wiring of addressable fire alarm system,
addressable fire alarm system ppt,
addressable fire alarm system protocol,
addressable panel fire alarm system,
ravel addressable fire alarm system installation,
addressable fire alarm system specification,
addressable fire alarm system siemens,
addressable fire alarm system,
addressable fire alarm system working principle,
addressable fire alarm system wiring diagram,
-----------------------------------------------------------------------------------------------------------------------
#Commissioning
#MorleyIASDXCautolearn
#Firepanelcommissioning

Пікірлер: 229
@techopinion7639
@techopinion7639 2 жыл бұрын
You are doing good work. Professional work 👌 Thanks from Lahore, Pakistan
@Ansari29
@Ansari29 2 жыл бұрын
Thanks for your comments 🙂
@Ansari29
@Ansari29 2 жыл бұрын
Pls share my videos in your company group
@tahirshaikh3989
@tahirshaikh3989 2 жыл бұрын
Thank u sir Most Awaited for this Vedio Jzk
@Ansari29
@Ansari29 2 жыл бұрын
Your most welcome Tahir
@Arbab_vlog88
@Arbab_vlog88 Жыл бұрын
Aapka video bahut helpful hota hai bhai
@Ansari29
@Ansari29 Жыл бұрын
Thank you, pls share my videos in your company group
@rohansuresh455
@rohansuresh455 2 ай бұрын
Hi Ansari we have Morley DXC panel. we have one fault with this (LOOP OPEN CIRCUIT L1) Before one heart detector damage. we change this detector, to the same address.
@Ansari29
@Ansari29 Ай бұрын
Aapky doubt ka video upload hogaya h please check. Pls subscribe to my channel & press the bell icon for notifications
@subratsahoo3657
@subratsahoo3657 Ай бұрын
Can you send me the video link for open loop ?​@@Ansari29
@superknowledge3135
@superknowledge3135 Жыл бұрын
Sir mere dxc4 panel ka LOOP CARD response nahi le raha h .sab card remove karne ke baad bhi har loop ka niche wala LED hi kam kar raha b
@jayantkumarmangaraj8689
@jayantkumarmangaraj8689 2 жыл бұрын
Informative Vedio, Can you please make a Vedio on addressable FA system with a laptop or desktop commssing.
@Ansari29
@Ansari29 2 жыл бұрын
I will try
@sayedmohdazim254
@sayedmohdazim254 2 жыл бұрын
Bhai mujhe batao apollo x95 panel mein addressing kaise edit karte hai. 1 vlog apollo x95 mein bhi banao Programming & Commissioning per.
@Ansari29
@Ansari29 2 жыл бұрын
Check karna padyga ....
@z.m.chainal6736
@z.m.chainal6736 2 ай бұрын
❤❤❤
@rabbualam8568
@rabbualam8568 2 жыл бұрын
Sir aap se ek request h ki addressbal system pe ek video banaye jis me kya kya device lagta h connection or
@Ansari29
@Ansari29 2 жыл бұрын
Yes Zaroor
@rabbualam8568
@rabbualam8568 2 жыл бұрын
Sir plz aage ka video bana kar daliye mai aap ka video ka wait karta hu ane ka
@Ansari29
@Ansari29 2 жыл бұрын
Sure Alam, thoda busy ho ek project m, jald hi new topics par video aana shru hojayega....
@Ansari29
@Ansari29 2 жыл бұрын
Thanks for your comment dear 🙂
@rabbualam8568
@rabbualam8568 2 жыл бұрын
Sir kab video bana kar daliyega jo hum bole the video bana ke dalne ke liye daliye n sir plz plz jaldi se
@Ansari29
@Ansari29 2 жыл бұрын
Hi Alam, mai ny addressable system ka ek video banaya h jismai almost sub explain kiya hoo Pls find below link kzbin.info/www/bejne/lWfCqZx9oqxneac
@gopikumarmishra8544
@gopikumarmishra8544 2 жыл бұрын
Honywell ka frenhight series IFP2100ECS ka manual programming ka video banaeye
@Ansari29
@Ansari29 2 жыл бұрын
Yes Sure
@sportswouldcup
@sportswouldcup 2 жыл бұрын
Sir drowning se xplane kar ke btaiye Honeywell Morley panel pe please
@zabirshah3472
@zabirshah3472 2 жыл бұрын
Assalamualaikum Bhai .aap ne zone ke bare men nahi btaya zone se hi hooter bajta hai kis detector se hooter bajana hai
@Ansari29
@Ansari29 2 жыл бұрын
Detector k activate hony par NAC circuit activate hojati hai or hooter ko supply milta hai
@asgarrkl
@asgarrkl 2 жыл бұрын
Please reply for the following 1. What is the loop card concept in a addressable fire alarm system? 2. Is there any cost difference between 2 loop panel and 4 loop panel of honeywell? or technically as we have total 300 devices in our G+5 floor. Do we need 4 loop panel?
@Ansari29
@Ansari29 2 жыл бұрын
1. Loop card means 1 loop circuit 2. Yes 2 & 4 loop panel have different cost. 3. More than 198 you have to install 4 loop panel
@tukaidutta5806
@tukaidutta5806 2 жыл бұрын
Shudhu ok marlei hobe naki panal khule lock korte hobe
@akashpandav9601
@akashpandav9601 2 жыл бұрын
Sir comishning ke pehle detector blink nahi karte kya?
@Ansari29
@Ansari29 2 жыл бұрын
Karta hai..
@vijilprajapati3756
@vijilprajapati3756 Жыл бұрын
98 smoke detector connect in 1 loop now I m extend one more loop and now we are 50 device divided to 2 loop now 1 loop 46 and other loop 52 But problem is before loop break and device divided so device missing error are occurs or not in 1 loop?
@Ansari29
@Ansari29 Жыл бұрын
Auto learn again, your issue will resolved
@MDKHAN-nh5vg
@MDKHAN-nh5vg 2 жыл бұрын
super 👍
@Ansari29
@Ansari29 2 жыл бұрын
Thanks Mr.Khan
@Ansari29
@Ansari29 2 жыл бұрын
Pls share my videos in your company group
@amolwankhade8433
@amolwankhade8433 Жыл бұрын
Dear .sir ... Monitor module. Control relay module And REPETOR Pnel ka ..commissioning kaise kare... Or isko addressing kaise kare .... Please bataiye
@rishikumar9788
@rishikumar9788 2 жыл бұрын
Mera or ek sawal hai Morley me beem detector ko kaise install karte hai control module - ya monitor modul me /
@vinayreddy.h5906
@vinayreddy.h5906 Жыл бұрын
Please do SMX 4 loop panel video
@Ansari29
@Ansari29 Жыл бұрын
Yes sure
@nirmalone3026
@nirmalone3026 Жыл бұрын
Ji i have one doubt? In Est3 Panel Ct1, Ct2, Cc1 what?
@mawazahmed3560
@mawazahmed3560 2 жыл бұрын
Sir Siemens Fire Alarm panel K baare me Kuch Details Bataye sir please
@Ansari29
@Ansari29 2 жыл бұрын
Ok I will try to make video on said topic...
@Ansari29
@Ansari29 2 жыл бұрын
Pls share my videos in your company group
@ligeeshk7268
@ligeeshk7268 Жыл бұрын
Sir in this, automatically detect the panel, which sensors are conected or not? And any brand of facp detect automatically the sensors? We have the duty to edit or adress the names
@hamidsayyad2727
@hamidsayyad2727 2 жыл бұрын
Bhia fire alaram.. K point ka kya charges h. Mtlb labour charhe
@Ansari29
@Ansari29 2 жыл бұрын
No idea dost...
@prashantsharma7828
@prashantsharma7828 2 жыл бұрын
Agar Morley fire panel me auto Learn krenge to Jo usme address h vo delt ho jyegi please btaiye
@rk6786
@rk6786 2 жыл бұрын
Hi bro your doing great job. I have dxc 2morlay panel fault showing device added. Once we lean the loop still same issue .. kindly give suggestions
@Ansari29
@Ansari29 2 жыл бұрын
Try to do autolearn
@rabbualam8568
@rabbualam8568 2 жыл бұрын
Assalamu alaikum sir video bahut din ho gaya h nhi lad rahe h kab daliye ga
@Ansari29
@Ansari29 2 жыл бұрын
Ha alam bhai thoda busy chal raha hoo Isiliye video record karny ka time nhi milra
@ak_double_one
@ak_double_one Жыл бұрын
What output is generated by the smoke detector which helps panel to recognise particular address of the detector.
@Ansari29
@Ansari29 Жыл бұрын
Alarm current
@rishikumar9788
@rishikumar9788 2 жыл бұрын
Sir commission karne ke liye main menu me konsa ki pahle press karte hai
@dhirendrashah2031
@dhirendrashah2031 2 ай бұрын
If we want to add new device in exsting system so what we have to do
@Ansari29
@Ansari29 2 ай бұрын
Just connect that device in loop circuit & do Auto learn & then do addressing
@deepaksarthi5786
@deepaksarthi5786 Жыл бұрын
Sir mujhe smoke detector se bina connection nikale smoke detector ko kaise bypass kar sakte hai
@ajaysingh1921
@ajaysingh1921 2 жыл бұрын
Hooters kawn sa lagega sir kya Morley ka Loop hooter lagega
@Ansari29
@Ansari29 2 жыл бұрын
Loop hooter.... Ya fir CM k through bhi hooter ko activate kar sakty hai but best loop hooter sahi rehta hai
@vijilprajapati3756
@vijilprajapati3756 2 жыл бұрын
We make communicate two morlay dxc4 panel each other. Fire occurs in one loop of one panel how to result of second panel and loop sounder are are coonect all system
@Ansari29
@Ansari29 2 жыл бұрын
There is one TX RX connection terminal for connecting 1 panel to other, you can simply connect & check. Meanwhile I will try to make video on said topic
@ShadabKhan-ks4hf
@ShadabKhan-ks4hf 2 жыл бұрын
Sir 1 loop m kitne detecter add kar sakte hain maximum
@Ansari29
@Ansari29 2 жыл бұрын
Morley m 99 detector add kar sakty h but har panel ka alag alag hota hai
@atharali8314
@atharali8314 2 жыл бұрын
very useful and knowledgeable video ansari bhai... how to contact to for queries
@Ansari29
@Ansari29 2 жыл бұрын
Thanks, pls send your queries to ansari2991@gmail.com
@mobitech7268
@mobitech7268 2 жыл бұрын
Sir, how much distance should be there between two smoke detector as per standard? And for above false ceiling detector spacing will be same or different?
@Ansari29
@Ansari29 2 жыл бұрын
Pls check my detector spacing video..
@syedzafar2068
@syedzafar2068 2 жыл бұрын
MCP agar detector k bich me lagana padta hai to mcp me bhi addressing karna padega kya?
@Ansari29
@Ansari29 2 жыл бұрын
Yes, Addressable system m mcp m bhi addressing hoti hai ...
@syedzafar2068
@syedzafar2068 2 жыл бұрын
@@Ansari29 thanks
@Satsangkamargjaigurudev
@Satsangkamargjaigurudev Ай бұрын
Hi i am getting fault - No Reply from device R001. i am not able to find the device R001. please reply on the same
@Ansari29
@Ansari29 Ай бұрын
Check panel programming. R001 kisko assign Kiya hai....wo faulty ya fir disconnect hua h
@sarfraj9317
@sarfraj9317 Жыл бұрын
Honeywell notifier Id 3000 evacuate program. How to know plzz 🙏 one video for this .
@rabbualam8568
@rabbualam8568 2 жыл бұрын
Hello sir new video kab dal rahe ho bahut din se intezar kar raha hu video ana ka daliye sir plz
@Ansari29
@Ansari29 2 жыл бұрын
Hi Alam, yes bohot din sy video nhi upload kiya because kuch personal reasons sy time nhi mil pa raha hai... But jald hi videos upload hogy.... Apko kon sy topic par video chahiye... Mujhe bataye m try karta hoo...
@rabbualam8568
@rabbualam8568 2 жыл бұрын
Thik h sir
@prajapatipragnesh3504
@prajapatipragnesh3504 2 жыл бұрын
Dxc panel main loop add kaise kare? Or comissioning me program kaise kare
@midhunsankar9974
@midhunsankar9974 2 жыл бұрын
Bro..we have simplex 4100 semi addressble pane.zone ways connection not adress type..we have 8 lift connected befor..now one lift NC wire is missing from fire panel..so wt we do for ne NC wire for lift?
@islamiyakhan9533
@islamiyakhan9533 6 ай бұрын
Sir is Honeywell Dxc 1 Morley IAS Mai conventional hoter chal skta h
@21rajmangade51
@21rajmangade51 2 жыл бұрын
Fire damper per video bano na
@Ansari29
@Ansari29 2 жыл бұрын
Ok I will try
@avaneeshkumar2902
@avaneeshkumar2902 5 күн бұрын
Morley battery wiring fault and battery missing aa raha hai Plz help me.
@rk6786
@rk6786 2 жыл бұрын
Next same Morley dxc2 address not set asper cabling it means as per cabling from panel 1,then 2 3,4 but detector address placed like from panel 2 address,1,4,3 if we install it's give any issue
@rishikumar9788
@rishikumar9788 2 жыл бұрын
Pls sir reply jarur kariye mujhe kal panel commissioning karna hai
@ismlkhn5635
@ismlkhn5635 Жыл бұрын
Morley fire alarm panel me languge change ka option kaha aata he mere fire panel me languge ka problem huwa he
@amitkumarjha6174
@amitkumarjha6174 Ай бұрын
I have faults in my device and it is not erasing. Device not resetting. Plz help
@Ansari29
@Ansari29 Ай бұрын
Check that fault, may be Detectors faulty
@devchauhan8814
@devchauhan8814 Жыл бұрын
Dear Ansari ji, Plz tell me for logic and pattern create
@Ansari29
@Ansari29 Жыл бұрын
Yes, I will
@prashantprabhune461
@prashantprabhune461 2 жыл бұрын
Hello., can you explain difference between Dx 4c & Zx 5e. why I should promote zx5 e then Dx
@Ansari29
@Ansari29 2 жыл бұрын
I need to check...
@rabbualam8568
@rabbualam8568 2 жыл бұрын
Sir aap se request ek video banai cctv camera ka installation ke bare plz
@Ansari29
@Ansari29 2 жыл бұрын
Yes Sure, I will try to make video on said topic.
@Ansari29
@Ansari29 2 жыл бұрын
Pls share my videos in your company group
@rabbualam8568
@rabbualam8568 2 жыл бұрын
Plz sir video dalo cctv camera installation ka plz
@Ansari29
@Ansari29 2 жыл бұрын
Yes Sure, thoda wait kijiye, jaisy time milyga bana k upload karuga ..
@rabbualam8568
@rabbualam8568 2 жыл бұрын
Sir full setup ke sath video bana ke daliyega installation ka video bada v jayega to koi dikkat nahi thik h sir
@amolwankhade8433
@amolwankhade8433 Жыл бұрын
Sir ji.. Monitor module ,control module Isolator module ..ka commissioning kaise kare...... Panel me nhi aarha hai...
@Ansari29
@Ansari29 Жыл бұрын
Auto learn karo
@amolwankhade8433
@amolwankhade8433 Жыл бұрын
MCP KE NAM SE ATA HAI.. USKO CHENGE KRKE MONITOR MODULE ...MON KRNA PDA SIR JI..
@amolwankhade8433
@amolwankhade8433 Жыл бұрын
@@Ansari29 Sir ji . Monitor module. Jo Flow switch ke liye use Kiya hai Usme input open circuit aa rha hai.. Iskya kya solution hai.. Please help me..🙏
@uttamchaudhari7794
@uttamchaudhari7794 Жыл бұрын
New detector add karne ke liye programing kaise kare
@faisalsaleem6046
@faisalsaleem6046 2 жыл бұрын
MCP mei data not available Jo fault hota ha wo kis waja say ata ha
@Ansari29
@Ansari29 2 жыл бұрын
Exactly nhi samaj aaraha hai....? What's ur panel fault
@arunasarthi2334
@arunasarthi2334 2 жыл бұрын
Sir two loop ka panel hai 1 loop sahi bta rha hai dusara loop me double address or divice fult batata hai cable ka continuity bhi check kar liya hu sab sahi hai ab kya karu jisase mera problem solve ho jaye
@Ansari29
@Ansari29 2 жыл бұрын
Device faulty m aap device change kardo or double address k liye m aapko solution dyta hoo thoda w8 kijiye....
@arunasarthi2334
@arunasarthi2334 2 жыл бұрын
@@Ansari29 divice change karne par bhi double address btata hai
@21rajmangade51
@21rajmangade51 2 жыл бұрын
Sir MSFD per ek video banau na
@Ansari29
@Ansari29 2 жыл бұрын
Ok Check karta hooo
@udaisinghbhati8590
@udaisinghbhati8590 2 ай бұрын
Sir loop open circuit q dika rah h please solutions
@NNK99
@NNK99 Жыл бұрын
Iss panel mein history log delete kaise karte hain please sir ??
@akashpandav9601
@akashpandav9601 2 жыл бұрын
Sir . What is device level fault???
@Ansari29
@Ansari29 2 жыл бұрын
Device level means detector sensitivity gets low. You have to replace it
@ShivPujan-iq5dw
@ShivPujan-iq5dw 2 ай бұрын
How to make cause and effect and delay time..
@avaneeshkumar2902
@avaneeshkumar2902 5 күн бұрын
Hi Bhai ji
@awadhrajpal2121
@awadhrajpal2121 2 жыл бұрын
Dear Sir Please I hope ki aap mujhe address pattern programming zone detail me explain kigiye
@Ansari29
@Ansari29 2 жыл бұрын
I will try, I need system so that I can make a video on itm
@user-ko8cy7ew7i
@user-ko8cy7ew7i 9 ай бұрын
Is there any Institute from where i can get training&programming licesence?
@mrigankapal828
@mrigankapal828 2 жыл бұрын
KISIKE PASS FIRE ALARM KA KAM HAI TO PLS BATAIYE, MUJHE KAM SIKHNA HAI PLS ANYONE, ANSARI VAI MAINE KNOWLEDGE TO LIYA LEKIN KAM KAYSE KARE, KAM HAI TO DIJIYE PLS
@guruprasad-bq9fz
@guruprasad-bq9fz 9 ай бұрын
Can I use all Sounders in loop.....
@Ansari29
@Ansari29 9 ай бұрын
If loop sounder then connect but before check load.
@dubeyshyam7570
@dubeyshyam7570 7 ай бұрын
Connfiguration fault kaise thik hota hai
@vivekkumarsingh8942
@vivekkumarsingh8942 Ай бұрын
Laptop se nahi hota hai kya
@nexttime2871
@nexttime2871 Жыл бұрын
Haw to connect addressable sounder in panel dxc 2 loop
@Ansari29
@Ansari29 Жыл бұрын
Hooter option provided
@abdulrahimkhan2029
@abdulrahimkhan2029 Жыл бұрын
Sir, device level fault how this problem rectify
@Ansari29
@Ansari29 Жыл бұрын
Detector Sensing level gets low, replace the device
@RohitKumar-ur5wn
@RohitKumar-ur5wn 2 ай бұрын
75 alaram point hor device kasa aad kra
@mohamedkamil4224
@mohamedkamil4224 2 жыл бұрын
Assalammu alaikkum, In facp where should i take the loop connection to repeater panel.form which terminal of the facp.
@Ansari29
@Ansari29 2 жыл бұрын
Use RS485 connection available in panel from point A & B to next panel point A & B. Use 2 core cable for it..I hope you have understood....
@mohamedkamil4224
@mohamedkamil4224 2 жыл бұрын
@@Ansari29 Thank you, in notifier panel the supervisory terminal is there.from that terminal i have to give loop between facp and repeater or any other terminal ports are there?
@ArifudinArif-in6tt
@ArifudinArif-in6tt Жыл бұрын
Sir output open circuit pls tell how to fix it
@activesystems4668
@activesystems4668 Жыл бұрын
if any demo with dxc-2 panel communication with usb lead cable
@Ansari29
@Ansari29 Жыл бұрын
I will try
@raswini9078
@raswini9078 9 ай бұрын
Signal corrupt fault showing, how to solve it
@HoseinSheykh
@HoseinSheykh 4 ай бұрын
Hello, how are you? I have an urgent question about morley dx 2 is it possible for you to help me?
@Ansari29
@Ansari29 4 ай бұрын
Tell me your doubt..??
@HoseinSheykh
@HoseinSheykh 4 ай бұрын
johan it means dear
@HoseinSheykh
@HoseinSheykh 4 ай бұрын
The output voltage of each 2 loops is 11 volts, is this correct?
@rabbualam8568
@rabbualam8568 2 жыл бұрын
Sir video nhi bana rahe h video bana kar daliye sir
@Ansari29
@Ansari29 2 жыл бұрын
Thanks Alam Thoda busy hoon ek project m. Next month sy regular videos aayegy. Each topic p.
@Rdl495
@Rdl495 2 жыл бұрын
Beam detector alignment video
@Ansari29
@Ansari29 2 жыл бұрын
Yes Sure
@Rdl495
@Rdl495 2 жыл бұрын
Thanks sir
@Rdl495
@Rdl495 2 жыл бұрын
Sir your contact plz
@tukunabehera7342
@tukunabehera7342 2 жыл бұрын
LED CARD ADDED fault shootout kese kare
@Ansari29
@Ansari29 2 жыл бұрын
Which panel
@swapnilsalvi4707
@swapnilsalvi4707 2 жыл бұрын
How to configuration morely fire panel to panel
@Ansari29
@Ansari29 2 жыл бұрын
Isi video m configuration h
@usmanali-xx3qe
@usmanali-xx3qe 2 жыл бұрын
Bhai fire alarm ki cv kase bane kiya ap mujey cv bana kar de saktey hai
@Ansari29
@Ansari29 2 жыл бұрын
Aapka jo bhi knowledge hai wo usmai daal dijiye..apny jis bhi fire panel p kaam kiya hai wo likh di jiye that's it
@usmanali-xx3qe
@usmanali-xx3qe 2 жыл бұрын
@@Ansari29 mere pass 6 saal ka experience hai notifier ka agar ap bana de tu ap ka thanks
@ShahbazHussain-iw6ol
@ShahbazHussain-iw6ol 8 ай бұрын
Reset Restart kaise kare sir
@omkardattsharma6336
@omkardattsharma6336 Жыл бұрын
Sir floor by floor hooter kse kre
@imbsr2221
@imbsr2221 Жыл бұрын
Hii sir this side bhaigirah mujhe morley ias addressble panel ko power device se Jodna tha jisse ki fire incident hone par light of ho Jaye uske liye mujhe panel me ek no to NC point chahiye tha please help me
@manindersingh-ex3mm
@manindersingh-ex3mm Жыл бұрын
Please help for DX related.
@Daisy-hy2qp
@Daisy-hy2qp 2 жыл бұрын
Sir pls tell us about how to provide power supply for FAS panel and hooters
@Ansari29
@Ansari29 2 жыл бұрын
External 24 VDV power supply
@DharmendraSharma-xn3lf
@DharmendraSharma-xn3lf 9 ай бұрын
Dxc4 mi zone divide kaise karen
@SantoshJadhav-su3bw
@SantoshJadhav-su3bw 7 ай бұрын
Dxc2 connection diagram with iclock990
@MohitKumar-hn2yx
@MohitKumar-hn2yx 6 ай бұрын
How to divice put in test mode.
@Ansari29
@Ansari29 6 ай бұрын
Go to programming mode.check test option will be there...
@amitkashyap2429
@amitkashyap2429 2 жыл бұрын
M facing Mon input 2 - input open circuit Mon input 1- input open circuit ...pls tell how fix this
@Ansari29
@Ansari29 2 жыл бұрын
Please check loop circuit, it may be open. Remove all the cable from the panel & take countinity test. You will get the idea.
@amitkashyap2429
@amitkashyap2429 2 жыл бұрын
@@Ansari29 i ihave checked my loop is okay ...but still its showing it
@ArifudinArif-in6tt
@ArifudinArif-in6tt Жыл бұрын
Output open circuit pls tell how fix this
@vijilprajapati3756
@vijilprajapati3756 2 жыл бұрын
how to create master panel in fire alarm system in multiple panel
@Ansari29
@Ansari29 2 жыл бұрын
There is no need to create master panel, as company already provide different model for master & slave. We just connect in terminal
@manojkambli1647
@manojkambli1647 Жыл бұрын
How to program Patten in dxc panel
@hanumanaika4321
@hanumanaika4321 10 ай бұрын
I need for hooter connection video
@mahendrasinhravalji3858
@mahendrasinhravalji3858 2 жыл бұрын
Fire foults kese sol kar sakte hai
@Ansari29
@Ansari29 2 жыл бұрын
Pls check my fault & troubleshooting video
@TabreezKashmire986
@TabreezKashmire986 Жыл бұрын
Id commissioning password changed then how to recover password?
@yashonathkoli7442
@yashonathkoli7442 2 жыл бұрын
Sir how to clear double address fualt.
@Ansari29
@Ansari29 2 жыл бұрын
Try auto learn 1st & then check which detector showing double address
@yashonathkoli7442
@yashonathkoli7442 2 жыл бұрын
@@Ansari29 sir Even after turning auto learning, the device is showing double address.
@nakcreativestuido4272
@nakcreativestuido4272 2 жыл бұрын
If we have old panel which is working on n loop we have to add more devices can we use auto learn for new device is the old address remove or not
@Ansari29
@Ansari29 2 жыл бұрын
You can add device & do Autolearn but make sure device address should not be repeated....
@Ansari29
@Ansari29 2 жыл бұрын
Pls share my videos in your company group
@saurabhkumars.k688
@saurabhkumars.k688 2 ай бұрын
Sir I m new uesr fire panal cheek of fire
@sagalakalatamizhan4837
@sagalakalatamizhan4837 Жыл бұрын
How to commission by pc Ji
Networking connection & programming of the ZX series panel
7:41
Honeywell Help & Support
Рет қаралды 9 М.
when you have plan B 😂
00:11
Andrey Grechka
Рет қаралды 51 МЛН
나랑 아빠가 아이스크림 먹을 때
00:15
진영민yeongmin
Рет қаралды 16 МЛН
Apple peeling hack
00:37
_vector_
Рет қаралды 120 МЛН
Incredible Dog Rescues Kittens from Bus - Inspiring Story #shorts
00:18
Fabiosa Best Lifehacks
Рет қаралды 39 МЛН
Morley IAS DXC-1 Panel Overview and Test
14:21
J1 Fire Systems
Рет қаралды 1,9 М.
How To Program A Device In On The Notifier NFS2-3030
6:41
FireTech
Рет қаралды 42 М.
Morley DXC Panel Connection with Repeater Panel
7:44
Low voltage
Рет қаралды 8 М.
Fire Alarm System Fault Troubleshooting.You must know
10:14
The Engineers Advice
Рет қаралды 11 М.
Class 2 | NFPA 72 | Fire Alarm System Basics
20:28
Irfan CFPS
Рет қаралды 2 М.
when you have plan B 😂
00:11
Andrey Grechka
Рет қаралды 51 МЛН