Very nice. Basic concept of msa is explained in very easy form
@qualitydocumentssolution-q81834 жыл бұрын
Thank you
@GaneshKumar-fr9jz2 жыл бұрын
Lots of thanks 🙏🙏🙏 Sir
@Bikash883 жыл бұрын
Nice teaching way
@bhupendrarajput85963 жыл бұрын
Thanks you sir for the information
@rightvision152210 ай бұрын
Thank you very much Sir,
@ajayphad23064 жыл бұрын
Nice explanation sir!
@qualitydocumentssolution-q81834 жыл бұрын
Thank you
@rahulhire2690 Жыл бұрын
dear sir, very respectful of you - so happy after watching this video. concept are clear about NDC
@deepakrajput31343 жыл бұрын
Very usefull video
@ravindragaikwad7544 жыл бұрын
Sir if we have 4 micrometer, but we mention in the control plan that measurement method by micrometer, in this case can we have to do msa for all micrometer Or any one of them.?
@qualitydocumentssolution-q81834 жыл бұрын
You can do MSA of any one micrometer but The range and least count should be same means equipment should be from same family. In case the range and LC are differ then you have to do MSA for all measuring equipment
@hariombhardwaj42314 жыл бұрын
Aap ki vedio bhut acchi hai sir. Mera ek question hai sir ki appraisers variation or equipment variation kitna hona chaiye ya kitna hota hai
@qualitydocumentssolution-q81834 жыл бұрын
Appraiser & equipment variations criteria not defined in MSA manual but logically it can be defined if equipment variations is greater than AV then the variation present in Equipment and if AV is greater than EV then the variation is present in AV . But the standard defined on R&R acceptance criteria. If R&R less than 10% the measurement system acceptable and Measurement system is whole thing you need to understand measurement system.
@vivekanandpandey5348 Жыл бұрын
Sir, We are manufacturer of stearic acid for a tyre company . We checks all the parameters like iodine value , acid value etc. by chemical titration method then how can we perform MSA.
@bhavnaacharya22543 жыл бұрын
sir msa grr value acceptable criteria me meet nahi hota
@chandansingh-jk1ci2 ай бұрын
Sir Pls make a video on full format filling of control plan
@kalpanasingh82993 жыл бұрын
In MSA Study ,How many Persentage of Part Varriation
@pawannagarkoti1015 Жыл бұрын
Sir please help me to know about gauge capability (cg and cgk) learning
@nehashukla65422 жыл бұрын
Sir,can u explain how many trial for MSA standard ???
@zikrullahakhtar97354 жыл бұрын
Sir yaha msa me Jo format ap gauge RR liye h wo excel me kaise likhete hai ye bataiye
@heenaeksambe33724 жыл бұрын
When are you going to upload MSA for attribute data...may I know sir please?
@qualitydocumentssolution-q81834 жыл бұрын
Working on it & coming soon
@vinaypathak49804 жыл бұрын
Thank you sir.... Video is amazing👍🏻... Can you please provide MSA GRR format..... Thank you once again sir
@omkarsingh3320 Жыл бұрын
Dear sir Explain the alluminum composition effects on casting defects and plz explain good effect and bad effect on casting
@Rakeshkumar-ou9ic3 жыл бұрын
Thank you sir plz update attributes variable video
@satyendramaurya66853 жыл бұрын
Thanks sir
@abis13264 жыл бұрын
What is the Difference between Pareto and histogram
@qualitydocumentssolution-q81834 жыл бұрын
Both are bar chat but there is huge difference between Pareto and Histogram Pareto chart used to show the defect data in descending order. But Histograms are used to show distributions of variables. And for more clarification you can watch video as already uploaded
@abis13264 жыл бұрын
Can you send that link
@qualitydocumentssolution-q81834 жыл бұрын
kzbin.info/www/bejne/gHeklZWBir51d8k
@qualitydocumentssolution-q81834 жыл бұрын
kzbin.info/www/bejne/b2erpoRpbrGBl6s
@abis13264 жыл бұрын
I want separate video on difference between Pareto and histogram
@ravindragaikwad7544 жыл бұрын
How to decide for which instrument we have to do which study??
@qualitydocumentssolution-q81834 жыл бұрын
See the given spec. is 5.0+0.3 then what measuring equipment you will select for inspection (0-25mm) and LC 0.001. You have to decide it yourself
@ravindragaikwad7544 жыл бұрын
It's ok sir but I want to know that for micrometer we will do GRR study, like that can we do GRR for vernier also or can we do bias for vernier.
@qualitydocumentssolution-q81834 жыл бұрын
GRR study is mandatory But you can do Bias study also
@ravindragaikwad7544 жыл бұрын
Sir will you please make a video on graphical analysis of msa studies to understand the results by seen the graphs.
@qualitydocumentssolution-q81834 жыл бұрын
Ok will make soon
@ravindragaikwad7544 жыл бұрын
Sir how to decide reference value in linearity and bias study???
@Dodu_Entertain3 жыл бұрын
Sir 200 Ni I think 20 banegi
@nehajogdand7604 жыл бұрын
What action need to take if msa fails in case of AP n EV ?? What action need to take if part variation is more than equipment variation and apprisal variation
@heenaeksambe33724 жыл бұрын
Action to be based on value of AV or EV.... If AV- check whos value is higher like wise... One of action is Training.. and need to do again MSA. If ev - check where it showed higher ... Replace, repair.. Sir will add some more into it...
@qualitydocumentssolution-q81834 жыл бұрын
First you have to See that if R&R is not acceptable then you need to take action now you need to analyse (through cause and effect analysis) that what is the actual cause of failure of R&R (Appraiser, Equipment, Environment, Method etc) . If you find actual cause then you need to take action on that.
@zikrullahakhtar97354 жыл бұрын
Sir apki koi in-house training center h
@qualitydocumentssolution-q81834 жыл бұрын
Yes but it is closed now due to Covid-19 you can join my online training program Join us on Facebook facebook.com/Quality-Documents-Solution-105064617608142/
@mihirpandya84774 жыл бұрын
sir, can we Compare Cp, Cpk = Accuracy, precision?? and Bias , linearity and stability Study is mandatory or not..???
@qualitydocumentssolution-q81834 жыл бұрын
It is clearly defined in SPC watch my SPC video 👇 kzbin.info/www/bejne/pJ-ZonVoatV2mNk
@manojmishra5445 Жыл бұрын
Dear Sir Can you please send me format of Guage Repeatability and reproducibility data collection sheet
@atultyagi32994 жыл бұрын
So Informamative session 😊, Sir may you provide ppt link so that we would download it ?
@shubhampal6497 Жыл бұрын
Sir msa 3 word ka hindi definition bta dejiya m,s,a, ka matlab
@avtar_singh-i7j Жыл бұрын
Sir pls share this ppt
@supriyobanerjee90813 жыл бұрын
Can someone explain me NDC calculation with an example: NDC= 1.41 (PV/R&R). How to get PV & R&R value
@bhavnaacharya22543 жыл бұрын
for forging
@heenaeksambe33724 жыл бұрын
Thank you so much for sharing.... Amazing video... I have two doubt.. 1. While doing GRR study, do we have to inspect on the same location Or in 90°.. especially for bore reading ? 2. Can we have to do MSA on all measuring equipment including CMM? What does about destructive test measurement reading (material yield )? Thank you in advance
@qualitydocumentssolution-q81834 жыл бұрын
1. You have to measure on different locations but in some case you can measure on same location. 2. If you have defined control method in Control plan the you have to do MSA as per defined measurement & test equipment . But the Measurement equipment you will select family wise If you have 5 micrometer and its range 0-25 & least count 0.001mm then you can take anyone for MSA study. No need to take all micrometer because the family is same. Thank you