Multi Winding Transformer Ratings and Connections

  Рет қаралды 13,495

Zack Hartle

Zack Hartle

Күн бұрын

Пікірлер: 10
@pablocalles9304
@pablocalles9304 Жыл бұрын
excelent explanation , without any complications.
@mattharvey8712
@mattharvey8712 8 ай бұрын
Bravo........u should be more famous.........great job...........using a auto transformer configuration ......does the split phase 240v or 2 chanels of 120v are in phase with each other.........I need one phase 180 degree out from other phase.......like u.s. grid power system ...... cheers
@iosefoyagomate5647
@iosefoyagomate5647 3 жыл бұрын
Thank you Zack...well explained
@ZackHartle
@ZackHartle 3 жыл бұрын
Glad it was helpful!
@iosefoyagomate5647
@iosefoyagomate5647 3 жыл бұрын
@@ZackHartle Oh yes you bet..Keep them coming...Can you give a presentation on transformer grouding primary and secondary single and three phases please
@LouisNhlanhlaKunene-yu1ud
@LouisNhlanhlaKunene-yu1ud Жыл бұрын
a1 a2 A3 and a4 on the secondary terminals or bushing , which terminal is neutral and which ones are hot
@aheropcs2009
@aheropcs2009 Жыл бұрын
Question: I am receiving a transformer 3P with 2 secundaries 12.47 Primary and 480/277 and 415/240, my location needs both and I design this to fullfill the requierement, now the company said it is one primary or the other, if part of my location is using 480 including panels and transformers to reduce to 240/120, is possible to connect my 480 transformers primary with 415 V and expect to keep going working in the same way. Please advise, thanks for your help
@insylem
@insylem Жыл бұрын
Question: Why are the H2 and H3 lines drawn crossed? Why are the X2 and X3 lines drawn crossed? I see that on the ones at work all the time too. Also, if you power only ONE H1 and H2 with 240VAC, could you use H3 and H4 to get 240 VAC? But at 2.08 Amps? If X1 and X2 are powered by 120VAC, can you use X3 and X4 for 120 VAC as well as the H windings ?
@wolfvash22
@wolfvash22 Жыл бұрын
Regarding why terminals are shown crossed, it has to be with how they are disposed for physical connection, just like how the terminal box is disposed in motors. This is a guess though, cause I have worked with motors but not with transformers. Now, regarding what you said about just using a half winding as a primary, you got it right, according to theory, you could even use only one winding as a primary with three secondaries available, and as long as you stay withing the power rating, it should work without a problem. Just for clarification, I am referring just to the theory behind transformers, could it be that a real world design doesn't allow to do such a use, due to other kind of constrains.
@keep_proud
@keep_proud Жыл бұрын
شرح رائع
Transformer Ratios
6:31
Zack Hartle
Рет қаралды 11 М.
Dual Voltage Windings - Part 1
14:59
Dave Gordon
Рет қаралды 55 М.
龟兔赛跑:好可爱的小乌龟#short #angel #clown
01:00
Super Beauty team
Рет қаралды 131 МЛН
Trapped by the Machine, Saved by Kind Strangers! #shorts
00:21
Fabiosa Best Lifehacks
Рет қаралды 31 МЛН
The Singing Challenge #joker #Harriet Quinn
00:35
佐助与鸣人
Рет қаралды 22 МЛН
All about Autotransformers
19:22
Zack Hartle
Рет қаралды 56 М.
How to identify a Mystery Transformer!
20:13
Doug De Young
Рет қаралды 4 М.
Percent Impedance of a Transformer
6:44
Zack Hartle
Рет қаралды 34 М.
Current Transformers (CT)
5:43
Autruo
Рет қаралды 16 М.
The most deadly project on the Internet
15:14
bigclivedotcom
Рет қаралды 7 МЛН
How 3 Phase Power works: why 3 phases?
14:41
The Engineering Mindset
Рет қаралды 1,5 МЛН
Wiring a Step-Down Transformer for a Power Feed
22:21
Clough42
Рет қаралды 61 М.
Primary Voltage Taps on a Transformer
7:13
Zack Hartle
Рет қаралды 28 М.
Transformers 101: How They Work & How To Wire Them
13:43
Schematix
Рет қаралды 417 М.
How 3 Phase Transformers Work - why we need them
24:24
The Engineering Mindset
Рет қаралды 945 М.
龟兔赛跑:好可爱的小乌龟#short #angel #clown
01:00
Super Beauty team
Рет қаралды 131 МЛН