The 320s are great panels. I like the Onyx series since you can actually program them. I wish the Simplex ES panels can be like that. I’m looking forward to a demo board of this panel (along with the SFP-10UD).
@vafirecollector95473 жыл бұрын
EIA Ports are for the annunciators, Security tamper is for if you have a tamper switch for the panel door. These panels are very simple once you learn how to program it. You can get the unlicensed version of verifier tools, but I find it more simple to field program the panel rather than messing with verifier tools.
@nics-systems-electric3 жыл бұрын
Ok thanks
@kalol11193 жыл бұрын
Nice panel!
@nics-systems-electric3 жыл бұрын
Thanks
@Roxxofoxxo3 жыл бұрын
congrats on getting a new panel!
@FireAlert3 жыл бұрын
good thing you watched my video on the AMPS and the CPS, your power supply is a CPS-24
@lumenfirealarms3 жыл бұрын
Hey congrats!! This is a really nice panel!! Looking the panel with that chassis I would say it is a 640 model!! You can see the model on the board! Stay safe and have fun!! ...
@nics-systems-electric3 жыл бұрын
Thanks. So you think it’s a NFS 2-640? If you don’t mind could you leave the time In the video that you saw where it said 640 you got me really curious now
@lumenfirealarms3 жыл бұрын
@@nics-systems-electric yes by looking the panel position and the size of the chassis yes I would say is a 640 you can look it on the edge of the board down the SLC TERMINAL, or using the lamp test and seeing the model on the display!! Or maybe cause is the Canadian model is different but normal NFS-320 the chassis is smaller that's the panel I have on my DEMO board!! Stay safe and have fun! Let me know what do you find!!! ...
@nics-systems-electric3 жыл бұрын
@@lumenfirealarms OK I was told it was a 320 but if it’s a 640 that’s even better I suppose
@lumenfirealarms3 жыл бұрын
@@nics-systems-electric yes you have the double capacity of points with a LEM-320!! Let me know when you find out!! Thanks good nite!! ...
@nics-systems-electric3 жыл бұрын
@@lumenfirealarms If I remember I will look tomorrow
@vrryan63 жыл бұрын
Awesome
@IanGSully2 жыл бұрын
Hey, for that Ground fault recognition switch, I guess that would make sense to disable it if the CPU had a problem permanent ground fault, and people don’t want to hear it go into trouble all the time while they wait on a new CPU
@wildtraingamer31463 жыл бұрын
Awesome panel it looks sick
@wildtraingamer31463 жыл бұрын
How many zones does the panel have?
@ryanwoods46913 жыл бұрын
@@wildtraingamer3146 318 points I think.
@nics-systems-electric3 жыл бұрын
@@ryanwoods4691 yes
@wildtraingamer31463 жыл бұрын
Thanks
@ryanwoods46913 жыл бұрын
Nice panel! The 9600UDLS does have an option for class A nacs.
@nics-systems-electric3 жыл бұрын
Cool I think you have to add a converter card though I wish it was standard
@gamingandvloging11173 жыл бұрын
@@nics-systems-electric you can do class A or B on the 9600udls
@ryanwoods46913 жыл бұрын
@@nics-systems-electric There is a card that you flip around right below the Mac terminals, you flip it one way for class A and the other way for class B. I can make a video on it.
@nics-systems-electric3 жыл бұрын
@@ryanwoods4691 I didn’t know that I wish the 9200 had that
@ryanwoods46913 жыл бұрын
@@nics-systems-electric Yea, only the 9600 has it, I think.
@MRIDNETGUY20043 жыл бұрын
Have it replace the 9200 when you get a can!
@nics-systems-electric3 жыл бұрын
Not sure if I will plus I would have to replace all my devices
@boydalexander46522 жыл бұрын
I LIKE NOTIFIER BETTER THEN EDWARDS EST I WISHED MY SCHOOL HAD NOTIFIER INSTEAD OF EDWARDS EST FOR THE FIRE ALARM SYSTEM.
@calebmorand46043 жыл бұрын
I have a question for you. Does the nfs-320 program the same with the panels keypad as the nfs-320C? Also are they basically the same panel? Thanks!
@nics-systems-electric3 жыл бұрын
Yes I would assume so pretty much the same thing
@calebmorand46043 жыл бұрын
@@nics-systems-electric could you program your nfs-320c with the panels integrated keypad? Thanks!
@nics-systems-electric3 жыл бұрын
@@calebmorand4604 yes
@IanGSully2 жыл бұрын
@@nics-systems-electric And that is what makes Honeywell better! Unlike the shit you get from Simplex or Edwards (EST).
@FireAlert3 жыл бұрын
I have a feeling the 9200 will get replaced with this if you can find a can.
@nics-systems-electric3 жыл бұрын
Maybe but probably not because I would need different devices
@hilo2-est3-elev2 жыл бұрын
1:55 What does checking memory mean? Can you add more RAM to make it respond to fires faster?
@nics-systems-electric2 жыл бұрын
no it’s just rebooting and checking if it has been programmed for a system or not
@Itself6863 жыл бұрын
Where is the fuse location in NFS 320
@nelsonedtz37093 жыл бұрын
System Test With System Sensor Low frequency sounder and 270SPO
@nics-systems-electric3 жыл бұрын
What are you talking about
@IanGSully3 жыл бұрын
I have a question, do you like Conventional panels, or Addressable panels better?
@nics-systems-electric3 жыл бұрын
Addressable
@uniteddrones76262 жыл бұрын
Do you need to use the same brand smoke detectors or just any addressable 2 wire smoke?
@nics-systems-electric2 жыл бұрын
You are supposed to use notifier if it’s a real protection system as it needs to be compatible with panel but fire lite devices will also work as well as some silent knight devices if it’s just as a demonstration or hobby system
@uniteddrones76262 жыл бұрын
@@nics-systems-electric cool appreciate it, ever plan on making programming videos on this panel?
@nics-systems-electric2 жыл бұрын
@@uniteddrones7626 I haven’t really done anything with that panel in so long so there’s nothing to show maybe I would but I feel like I don’t know enough about it
@uniteddrones76262 жыл бұрын
@@nics-systems-electric that’s how I feel very small amount of info online abt notifier panels on KZbin anyway, lots and lots of manual reading for now
@Fire-hq3rm3 жыл бұрын
How many simplex devices do you have?
@nics-systems-electric3 жыл бұрын
1
@Fire-hq3rm3 жыл бұрын
@@nics-systems-electric and which is that
@IanGSully3 жыл бұрын
How much do those panels cost used?
@nics-systems-electric3 жыл бұрын
Not sure I haven’t seen many 320 Used
@M_huhn2063 жыл бұрын
I think you can do voice evac
@nics-systems-electric3 жыл бұрын
I think that’s only with the 640 and 3030
@vafirecollector95473 жыл бұрын
@@nics-systems-electric Correct, only the 640/3030 is compatible with the AMG-1 or ATG-1
@FireAlarm333 жыл бұрын
Where will this be put?
@nics-systems-electric3 жыл бұрын
Demo system
@vrryan63 жыл бұрын
what is the difference between the nfs-320 and 320c
@nics-systems-electric3 жыл бұрын
Canadian model The most obvious difference is the cabinet comes in which I talked about in the video and there might be some different programming options for Canada
@jepps10213 жыл бұрын
The 320c comes all in one encloser and is designed for no panel models other than a network card and two ACM24 annunciator. The 320SYS is what he has and can be put in different sized cabinets.
@nics-systems-electric3 жыл бұрын
@@jepps1021 I forgot about that one
@vrryan63 жыл бұрын
@@jepps1021 ahh
@SomeDudeWithAnExitSign3 жыл бұрын
Personally I don’t see a use for the 320SYS. I guess they can be a retrofit for the newer system 500s but I think people would just install a regular 320 instead. I would rather have a compact NFS2-640 instead (like the Siemens MXL-IQ). I think it’s too late since the inspire series is almost there to be released.