Column size and sariya details for 1 storey,2 storeys,3 storeys, 4 storeys & 5 storey house

  Рет қаралды 322,434

My Engineering Support

My Engineering Support

Күн бұрын

Disclaimer - This video is for educational purposes only. Copyright Disclaimer under section 107 of the copyright act 1976, allowance is made for "fair use" for purposes such as criticism, comment, news reporting, teaching, scholarship and research. Fair use is a use permitted by copyright statutes that might otherwise be infringing. Non-profit educational or personal use tips the balance in favour of fair use.
Column size and sariya details for 1 storey,2 storeys,3 storeys, 4 storeys & 5 storey house
In this video we know about column size and sariya details for Single storey building, double Storey building, 3 storey building, 4 Storey building & 5 storey floor building and also know about what is minimum and maximum distance between two-column. Ek manjila Makan, do manjila Makan, 3 मंजिला मकान और 4 मंजिला मकान के लिए कॉलम का साइज और सरिया क्या होना चाहिए. column size for G+0, G+1,G+2,G+3 Building construction.
#RCCColumnStandardSize #ColumnReinforcement #ColumnHeight
Topic Covered:-
Columns sizes for various floors
Column size and sariya details for 1 storey,2 storeys,3 storeys, 4 storeys & 5 storey house,
building design
various column sizes
what is the column size for the g+1 building
minimum column design
g+1 building design
column design
minimum size of column
column size for ground story building
different column sizes
apartment building column sizes
building design by staad pro
column size for 1 storey building
column size for 2 storey building
column size for 3 storey building
column size for 4 storey building
column size for g+0 building construction
column size for g+1 building
column size for g+2 building
column size for g+3 building
RCC Column Standard Size
RCC column standard size
the standard size of the column
standard column size residential building
RCC column size calculation
Bar Bending Schedule Basics: Especially for Freshers Civil Engineers (Bar Bending Schedule Part-1) Kindle Edition
amzn.to/3uvEMNo
My Social Media Link:-
Telegram Link:-
t.me/yoursengi...
Facebook page:-
/ yoursengineer
Facebook group:- / yoursengineer
Twitter link:- / yoursengineer
Instagram link:- / yoursengineer
Pinterest:- / _created
Linkedin:- / vishal-goel-17426a48
Website:- myengineeringsupport.com
Accessories I Use for making Videos
Mic I use - amzn.to/3r5f1S6
The laptop I use - amzn.to/3ayYNu3
Laptop Stand I Use- amzn.to/3cnILpj
_______________________________________________________
LIKE | SHARE | SUBSCRIBE FOR MORE VIDEOS LIKE THIS
~
THANKS FOR WATCHING! -ENJOY
===============================

Пікірлер: 313
@aebyscreationsfunlatest1456
@aebyscreationsfunlatest1456 2 жыл бұрын
Thankyou so much sir, bahut videos dekha par doubt clear nahi ho raha tha , par aapne sare doubts clear kar diye .. very informative video 😊🙏👏👏🤗🙏
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
My pleasure 🥰
@निलेशपटेल-ध4थ
@निलेशपटेल-ध4थ 2 жыл бұрын
Apka videos bahut help karta sir ji.... Nice video making
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
Thanks
@PMPlansDesign
@PMPlansDesign 3 жыл бұрын
Sir G+3 keliye column size 10" by 16" provide kar sakte hain ? Or beam size 10" by 15" provide kar sakte hain ?
@myengineeringsupport
@myengineeringsupport 3 жыл бұрын
size of an RCC column should be 12”x 12” (300mm x 300mm) with 6 bars of 12mm Fe500 Steel with m20 grade of concrete and stirrups of T8@6″C/C.
@PMPlansDesign
@PMPlansDesign 3 жыл бұрын
Acha . Lekin 10" by 16" dene se kuch problem hoga kya . In future 1 manjila bhi uske upar banana hai .matlab G+4
@helpmetoreach10kwithoutany14
@helpmetoreach10kwithoutany14 2 жыл бұрын
@@PMPlansDesign 12by 12 is sufficient and you have to change the reinforcement must go from down to up with 16mm of 4 and 12mm of 2 rods thnku
@inovativeabhijit3276
@inovativeabhijit3276 2 ай бұрын
2 manjila ghar ke liye column ka rod size 12 inch ka and no of bar 6 ye best hein ya 16 inch ka rod and no of rod 4 , konsa best hein
@soumyadas2395
@soumyadas2395 8 ай бұрын
Sir humhara 2 manjil hai column 10×10 hai aur usme 4 sariya 12 mm ki hai aur usme stripes 6/5.5 mm ki hai to sir es se koyi problem hoga kya?
@MR.SM_MOTIVATOR
@MR.SM_MOTIVATOR Жыл бұрын
Sir, mere ghar ka plinth level ground level se 7 ft hai. Two storied building hoga. Abhi column kiya hai (10*10) aur 6nos 12 mm bar, aur beam kiya hai (10*12) 5nos 12 mm and extra top 12mm, slab hai 5 inch. Isse koi dikkat to nehi hoga. Please reply 🙏
@devbhatt1000
@devbhatt1000 Жыл бұрын
Sir 9×9 inch column mai kya G+2 ya 3 manjil makaan bana sakte hai??
@sagarjadhav9637
@sagarjadhav9637 2 жыл бұрын
Sir video is very important for us, sir what to take column size, and steel for P+5?
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
Contact for structure drawing 9996656740
@Pragyanand01
@Pragyanand01 Жыл бұрын
Nice information sir... just need one clarity .. for g+4 can we use 12"x14" colum with 4x 16 bar and 2 x 12 bar ...mistri aise hi bata raha hai..sab jagah bana hua hai
@Vishaljaiswal75
@Vishaljaiswal75 2 ай бұрын
@@Pragyanand01 sahi hai itna hi har jagah lagta hai
@CisPlatin-c5h
@CisPlatin-c5h 21 күн бұрын
kitna kharcha aaya total complete hone mai
@lingarajswain3086
@lingarajswain3086 28 күн бұрын
For G+1 , column distance 4m . Column size 9*12 ,steel used 16mm 4pc and 12mm 2pc , is it safe?
@निलेशपटेल-ध4थ
@निलेशपटेल-ध4थ 2 жыл бұрын
Hi,... Sir... How are you... I hope... You are well.... Sir mera apse ek sawal hai ap please uska jawab dena.. Please.... Sir hamne ghar banaya tha 1 story home... Column ka size diya tha 9 into 9 or ghar ka area ha total 865 square feet hai... Sir hamre ghar me total 15 column lage hai...10 se 8 feet ke duri par . Or ab hm chahate ki uske upar or ek or story banana hai... Tho kya hm bana sakte hai ki nahi only or ek story ghar badana hai.. Matalb 2 manzil banana hai.... Foundation ka work tha 5 into 5..and depth 5.. .. Second manzil ka sariya kya rakna hai ab... Pehle manzil ka sariya 10mm or 12mmm use huwa hai... Please reply
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
Ok column me steel kya use kiya
@निलेशपटेल-ध4थ
@निलेशपटेल-ध4थ 2 жыл бұрын
@@myengineeringsupport column me steel 6 bar use kiya tha 10mm ke 4 bar or 12mm ke 2 bar or 6mm ka square box 6inch ki duri par kiya tha.... Kya ab 2 story add kar sakte ki nahi....
@dhruvarora4179
@dhruvarora4179 2 жыл бұрын
Pls tell G+4building me ground and first floor ke baad dealer coloum size kar raha hai is it right Upper ground tak 9x18 uske baad 1st floor pe 15x9 Then upar ke 2 floor 12x9 or 9x9 karra hai Please answere
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
Yes no problem size km ho sakta h par bars nhi
@neerajsaini9248
@neerajsaini9248 11 ай бұрын
Sir maine 1 plot liya hai jiska size 28×27 hai .or uske columnka size 9*9 ke 5 column hai .jisme 16 ke 4 baar or 12 ki 2 baar hai or column distance 10 foot hai jo mujhe g+4 banana hai . Kya mujhe colum change karane padenge..
@incredibleshohratkhan4382
@incredibleshohratkhan4382 3 жыл бұрын
Thanku so much for making this owsome vid, pls tell G+5 me kya column size rhega or kon se bar use krne padenge.column distance 14×11 hai.
@myengineeringsupport
@myengineeringsupport 3 жыл бұрын
For 5 storey,G+4 building the size of an RCC column should be 12”x 18” (300mm x 450mm) with 4 bars of 16mm and 4 bars of 12mm Fe500 Steel with m25 grade of concrete and stirrups of T10@6″C/ ...
@exam3247
@exam3247 Жыл бұрын
Sir, ghar k base me 16 mm Char column size 9*9 ha upar ja krr column ka diameter Kam hota ha to 12 mm Char me baad me 6 mm ka churi usse G+4 utha skte h kya???
@incredibleshohratkhan4382
@incredibleshohratkhan4382 3 жыл бұрын
Sir jaise jaise buildin bante jaye column ka size b kam sakte hai ??? Jaise ground floor 12"×18" fir first floor 12"×16" fir second floor 12"×14", is tarah har floor pr km bhi krte jaa skte hai???? Pls pls reply
@myengineeringsupport
@myengineeringsupport 3 жыл бұрын
Bilkul kr sakte ho
@rahulbharvad7292
@rahulbharvad7292 Жыл бұрын
Sir... Agar 3 manjila building me size column 12*15 rakhe ho and bar size me 25mm*4 rakhe ho to risk rehta hai kya???
@vikasseth5277
@vikasseth5277 Жыл бұрын
Sir ji 9/12 colum me 4bar 16mm our do bar 12 mm ke de ke g+4 normal house bna skte hai our ek colum se dusre kolum ki duri 10 fit ya 11 feet ho ....
@MAHESHKUMAR-gs5cu
@MAHESHKUMAR-gs5cu Жыл бұрын
Sr, please btaye ki ek room 10*10 and ek bathroom 6*4 ko banane le kya cost aayegi
@WithSimpleLife143
@WithSimpleLife143 Жыл бұрын
Mera collum 9 by 24 ka h ye kya sahi size.... Aur kitna manzil jaa sakta.... Hai.... Distance 2 collum k beech... 13.5 feet h... Plz sir riply kariye
@mohammedajaz9993
@mohammedajaz9993 Жыл бұрын
G+5
@MadhuReddy782
@MadhuReddy782 4 ай бұрын
Sir we used 9*14 columns, with 4 16mm and 4 12mm rods for g+3 with all 8mm rings, is this okay ...can the building sustain..
@pradeepbhokare3399
@pradeepbhokare3399 Жыл бұрын
Hallo sir, mare Ghar ke construction me 15 foot column ki length rakhi hai our column 9*18 inch column liya hai ye sahi hai kya sir our abhi bheam pooting se 3 foot uchi pe liya hai kitna mm ke our kitne road use kare
@ganjamanja8797
@ganjamanja8797 2 жыл бұрын
Sir g+2 ke liya 4 tho 16 ka or 2 tho 12 ka de sakte he or size 12"*12" Plz reply sir
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
Yes
@pradeepkumar-cr8ph
@pradeepkumar-cr8ph 3 жыл бұрын
Is,This,coulm size is applicable,for both type of building commercial and resedential.
@myengineeringsupport
@myengineeringsupport 3 жыл бұрын
No only residential
@kamjitpradhan1626
@kamjitpradhan1626 Жыл бұрын
Sir mera 25*75 ka ghar hai,mein usme 10*15 ka 10 column Diya hun aur 10*12 ka 8 column hai,,total column Mera 18 hai,is it safe for us
@VijayKumar-or2op
@VijayKumar-or2op 2 жыл бұрын
बहुत सुंदर जानकारी
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
Thanks🙏
@monimadhavtaid4796
@monimadhavtaid4796 7 ай бұрын
Sir ghar ka hight bota dijiye
@md.farhan4960
@md.farhan4960 2 жыл бұрын
Thanks a lot for helpful information Sir 👍
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
My pleasure🙏
@bhaskarsarkar5559
@bhaskarsarkar5559 2 жыл бұрын
Sir mera 27*25 fut mey g+1 ghar k liye 10"×10" colum size diya or 12 mm 6 nos tmt bar diye or colum to colum distance 3.5 meter diya kuch problem hoga keya? Plz advice 🙏
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
No it's ok
@CivilEngineerPrashantSingh
@CivilEngineerPrashantSingh Жыл бұрын
Sir yadi ek building me sabi column size ek Saath Lage ho to iska kya matalab hai.
@ramakantadeori784
@ramakantadeori784 Жыл бұрын
Sir hum g+2 house bna rai mera reinforcement 6 nos 12 mm gadha 4 foot dept or footing 8 mm spacing 4 inch or pose ka size 10×12 kya yeh save hein g + 2 storey ke liye please reply me sir
@aliqadri4672
@aliqadri4672 2 жыл бұрын
Thanks sir ap say ye poochna tha kay 5 story building kay liey jo column size or rienforcement rahy ga footing say wo uper 5th floor tak jaty jaty same size or rienforcement rahy ga ya kam hoga ya barhy ga or beam or slab ka size or rienforcement ground floor say leky uper 5th floor tak jaty jaty kiya thickness or bars may koi diffrence ayga beam or slab kay ya nai plz reply zaroor krna sir.??
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
Aap upar jate huye column size or reinforcement size km kar sakte ho jitna km load utna km size kr sakte ho
@aliqadri4672
@aliqadri4672 2 жыл бұрын
@@myengineeringsupport mera matlab hay kay jo column footing say jitnay size or rienforcement ka nikal raha hy or 5 th floor tak jaey ga to is surat may column ka size or bars neechy say or uper tak kiya same dimension or bars rahein gy ya koi tabdeeli ayegi uper waly columns may ..matlab kay jo bars column may hain os say uper wala column ki bar os say zyada thick hongi ya less hongi dia may..???or sary floor same construct hongy aik jesy
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
It's totally depends on your budget
@abhishekupadhyay6930
@abhishekupadhyay6930 2 жыл бұрын
Sir, My house with only ground floor was constructed in 2010 with only 10mm ×4 rod. Nw m planning to built 1st floor on tht house what should I do nw?
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
No mt bnana
@abhishekupadhyay6930
@abhishekupadhyay6930 2 жыл бұрын
@@myengineeringsupport sir can you guide me if i want to construct 1st floor bcoz my family is big wht should I do for the strength?
@saurabhphatanagare8427
@saurabhphatanagare8427 2 ай бұрын
6 * 18 size colume chalega kya ...... Niche parking aur upar makan keliye .... 6 inch bricks work karana hai.....
@rahulsondhiya6013
@rahulsondhiya6013 Жыл бұрын
Sir, total area 450 sq feet total 9 columns of size 9*9 4 rods . Kya 16 mm dia rods use kr skte h mazbuti k liye. ???
@RajendraRajRp
@RajendraRajRp Жыл бұрын
Sir ham 1,2,3 Manjila makan ke liye faundesan khudai+ jali L size kitna rakhna hai,khudai kitna karwaye, abhi2 manjila de rahe hai please bataiye sir
@usamam2227
@usamam2227 5 ай бұрын
is it for frame structure or load bearing???
@uddhavbhosale9382
@uddhavbhosale9382 6 ай бұрын
Sir mera ghar ground flower + 2 flower he or 9×15 ke collam size rakhi he ithana sahi he kya
@yalakalasagar3095
@yalakalasagar3095 2 жыл бұрын
Bahut badiya hai sir
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
Thanks🙏
@durgesh2015
@durgesh2015 Жыл бұрын
Sir, 9 inch by 18 inch column ki size me column to column maximum distance kya rakh sakte h?
@Justamizing
@Justamizing Жыл бұрын
Sir 10"×12" pillar se G+2 bana sakta hai kya.pillar to pillar distance 12 feet se 14 feet hai aur pillar mai 4 nos.of T16, 2 nos.of T12 mm dia use kya hai
@ayoubarshad697
@ayoubarshad697 2 жыл бұрын
Sir 3 story keliay 12 mm ki 8 bar use kr sukta Hain aur ye kaesa rahe ga jbke column to column distance 7 feet hae aur plenth beam main konsi bar perfect rahe gi
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
Ok h plinth beam minimum 12mm
@ayoubarshad697
@ayoubarshad697 2 жыл бұрын
Sir plenth beam main kitni rod honi chahea keon ke 3 story hae
@sagarnannaware3655
@sagarnannaware3655 2 жыл бұрын
Your all video very helpful us🙏
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
Thanks 🙏
@zakirafridi3127
@zakirafridi3127 Жыл бұрын
sir can you please clear k ye thumb rules frame structure klye hai ya load bearing structure qu k deehat mai mostly load bearing structures bnty hai.
@sanjayaggarwal446
@sanjayaggarwal446 Жыл бұрын
Video acha h. Lakin bohot fast chala rahe ho. Screin shot leynay may dikkat hoti h.
@arjunseth5081
@arjunseth5081 Ай бұрын
2 manjil me kalam aur bim size 15ft duri rakhanr par kya hoga
@sagarverma08
@sagarverma08 4 ай бұрын
After g+2, I used 4 steel-16 mm dia and 2 steel -12 mm dia in my column, I have constructed G +4, is there any problem.
@shaikhmohammadumar6457
@shaikhmohammadumar6457 2 жыл бұрын
Too good God bless you
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
Thanks 🙏
@lakhangade2870
@lakhangade2870 2 жыл бұрын
Sir hamari jaga 18x21 he or hamara busment he or hamare total 8 coulm he or centar me coulm nahi li lekin 1 coulm se dusre coulm tak 18 feet bhim liya he or hamare coulm me 16 mm ke 4 or centar me 12 mm ke 4 Siriya use kiya he or upar bhi yahi he or flor 3 me chhoti coulm liya he or use coulm me 16 mm ke 4 or centar me 12 mm 2 siriya use kiya he or flor 4 ke coulm me sabhi coulm me 12 mm ke 6 siriya use kiya he to muje dar lagraha flor 3 ke coulm or flor 4 ke coulm o load le sakti he ya koi problem asakta he reply
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
No problem
@gangasahuenglish
@gangasahuenglish Жыл бұрын
15 fit*15 fit room hone me koi dikat to nai hoga
@prakashsalawria9274
@prakashsalawria9274 2 жыл бұрын
sir 5 storey building me footing konsa best h slopped ya stepped?
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
Depending on soil conditions
@daler75
@daler75 7 ай бұрын
Kya ham 9×18 me 4 सरिया 20mm ka aor 4 सरिया 16mm ka dal सकते hai?
@modanidarshana4247
@modanidarshana4247 2 жыл бұрын
Roof beam Ka same aise hi video banaye sir please...
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
Check on channel
@tonperme2840
@tonperme2840 Жыл бұрын
Maine colunm ki size 12 by 12 aur sariya 16 mm ki 4 aur 12 mm ki 2 laga diya he .. ( Ghar = G + 1 +2 Floor ) lekin gaddhe ki geherayi sirf 5 feet aur 4 feet chorayi he . Future me koi problem to nahi hoga na ? Pls help 🙏
@CisPlatin-c5h
@CisPlatin-c5h 21 күн бұрын
@@tonperme2840 kitna kharcha aaya total complete hone mai
@ambarsharda6741
@ambarsharda6741 Жыл бұрын
Sir Apne Puri video me Column ke Ties ko Stirrups bola hai..... Difference is In columns we call them Ties and In Beams we call them Stirrups. Apne jo (G+4) Five Storey Building ki details btate time 8 no of bars wali drawing show nahi kari..... These are Thumb rules (basic rules) for understanding.....Nice video 😊
@siddhartsrivastava2883
@siddhartsrivastava2883 Жыл бұрын
My architect is advicing me 9×14 size coloum, for my G+2 story building. Is it good?
@mohammedajaz9993
@mohammedajaz9993 Жыл бұрын
Yes you can go for 9*15
@satpalbhiduri8948
@satpalbhiduri8948 2 жыл бұрын
Sir m G+ 4 ke liye column size 9/15 le skta hu aur ush m 12 mm ke 8 sariya use kr skta hu aur mere column to column distance h 14 ft
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
Yes
@s.k..s.k.2s.j.a..594
@s.k..s.k.2s.j.a..594 Жыл бұрын
Bohot acha. Ji
@lavleshtindal
@lavleshtindal Жыл бұрын
Sir humne 70 fit hight leni hai starting colom size kya rhega
@Sigmamale07-b7k
@Sigmamale07-b7k Жыл бұрын
Thank you Sir
@Putul08
@Putul08 2 жыл бұрын
Thanks for your advices
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
Welcome🎉
@sumanmitra9587
@sumanmitra9587 11 ай бұрын
As per SP-16, all reinforceme ts are placed on the shorter dimension of the column. You placed all the reinforcements on the longer side ??
@DevendraSingh-td2dw
@DevendraSingh-td2dw 2 жыл бұрын
U Really right Sir, Thanks
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
My pleasure🙏
@pankaj9934
@pankaj9934 Жыл бұрын
15/30 ka plot size hai G+2 banana hai kya Colum 12/9 ki and 12mm 6 bars Plinth beam 9/9 ki and 12 mm 4 bars Floor beam 9/9 ki and 12 mm 4 bars Shai h ????????
@Birendrakumar-yz5vc
@Birendrakumar-yz5vc Жыл бұрын
Very good Sir🙏
@vickychoudhary9793
@vickychoudhary9793 2 жыл бұрын
Bhai main 4 majila ghr bnwa rha hu kya mujhe sujhav de skte hai
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
Yes contact me
@bishalmalakar4125
@bishalmalakar4125 2 жыл бұрын
Sir main 2 manjila imarat banana chahata honnn usmain 4 room hoga kitna cost ayeega
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
Plot size btao brother
@mohdmahzar7330
@mohdmahzar7330 2 жыл бұрын
Hello sir Mera ghar G+2 hai 55 ,24 aur jis me 18 kalam 9 12 ke 6 12 ke baar hai kya Mai G+3 kar Sakta hu
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
Yes
@naveensharma-sg8xu
@naveensharma-sg8xu 2 жыл бұрын
Sir hamne 3 storey mandir ke liye 16 mm ke 8 sariye liye h thik h kya
@anantabhai4770
@anantabhai4770 2 жыл бұрын
Good explanation 👏👍👌
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
Thanks
@pankajguptacutebaby
@pankajguptacutebaby 2 жыл бұрын
70*41 plot size black soil footing better or pilling Agar footing to depth kitna bar size and column size please reply
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
Go with Pile foundation
@poojaprabhudesai4592
@poojaprabhudesai4592 2 жыл бұрын
Sir partition wall 4" aur 6 " ho to internal column kaise ayenge.please btayiye
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
Means?
@vikalawa5301
@vikalawa5301 Жыл бұрын
Sir 30 × 50 ka plot hain 2 manjila Column ka size kitna hona chahiye
@prasadbanni8231
@prasadbanni8231 Жыл бұрын
G+4 Mai column size kab kam karni chahiye...hamare engineer ne ground floor ko 9×21 ke column Dale pr 1 floor kon 9×18 Kiya...ye chalta hai kya..
@呼呼是的
@呼呼是的 2 ай бұрын
Nhi bhai engeriner 🤔 to kabhi asa nhi karega isse column mai bo strength nhi rehegi
@durgeshkumardubey10
@durgeshkumardubey10 2 жыл бұрын
G+3 floor ke liye 9x12 ke colom me 16mm ke 6 bar use kar sakte hai Plot size 18 x 30 and colom to colom distance minimum 7feet and maximum 10feet
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
Yes you can
@prashantpol933
@prashantpol933 3 жыл бұрын
Can I use 9" X 24" columns for G + 6 building? Thanks in advance
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
No consult with structural engineer
@mirmohasinreza
@mirmohasinreza 2 жыл бұрын
😁
@dhawalbharwad8733
@dhawalbharwad8733 Жыл бұрын
Can i use 9 + 15 columms for G3 Residential Room. We used 25 mm steel bar in maine colum nd 12 mm 2 nd 3 flor ??
@khaninayat8994
@khaninayat8994 3 жыл бұрын
Helo sir mene 9*9 colum pe grund flor banay he ab me G+1 banana he kiya bna sakta hu mere ghar ka aria he 28×40 total 15 colum he ples raply
@myengineeringsupport
@myengineeringsupport 3 жыл бұрын
Yes you can
@gauravkr4760
@gauravkr4760 2 жыл бұрын
Great video
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
Thanks
@nuruzzamansk1768
@nuruzzamansk1768 Ай бұрын
Sir, if this pillar goes to four floors and make it 10/10 pillar, then don't we have to cut the rod, is there any other way, it would be better if we make a little design.
@virat9988
@virat9988 Жыл бұрын
Informative
@modanidarshana4247
@modanidarshana4247 2 жыл бұрын
Sir please tell me soon ...instead of 12* 12inch ...can I take 9*15
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
Not recommend
@---vm8hz
@---vm8hz 2 жыл бұрын
Please add cost also in this series it will be very helpful
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
Noted
@karmajamatia8260
@karmajamatia8260 Жыл бұрын
Good evening sir
@JAYMAAKAMAKHYADEVI
@JAYMAAKAMAKHYADEVI 2 жыл бұрын
क्या 5 मंजिले मकान में 9 ×18 इंच का पिलर दे सकते है, पिलर से पिलर की दूरी 15 फूट होगा
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
No
@JAYMAAKAMAKHYADEVI
@JAYMAAKAMAKHYADEVI 2 жыл бұрын
@@myengineeringsupportतो कितना size देना चाहिए column का distance 15 foot हो 5 storey building में🙏
@parveens5475
@parveens5475 2 жыл бұрын
Sir G+2 floor ke liye 9x12 colom me 12mm ke 6 rods lesakte hai?
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
Yes
@sachiny4662
@sachiny4662 Жыл бұрын
Can we use 9 by 15 column for g+2 . Because wall size is 9 inch
@abdulazaj1212
@abdulazaj1212 Күн бұрын
Columns ka designing structure load ke hisab se Calculate krna hota aise Andajan krna Dangerous ho skta h....islie hameha Load ke hisab se Column design krwaye Structural Engineer se jarur consult kre....
@sayhamshourav
@sayhamshourav Жыл бұрын
Thank you so much
@GauravKumar-tu5ql
@GauravKumar-tu5ql 2 жыл бұрын
Sir column ka size kya hoga for g+2 and distance between two columns is 19ft
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
Consult with structural engineer
@saudivlogs1259
@saudivlogs1259 2 жыл бұрын
Sirmujhe 20*25 ka hall banwana hai or Starers bhi banwane hai lekin callum side me hi chahiye beej meek bhi nahi to size or bar keya rakhe
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
Approx 7lakh
@sachinmalkari1890
@sachinmalkari1890 Жыл бұрын
Colum ke size ke sath colum ki duri kitni rakhani chahiye
@Dutta-Engineering
@Dutta-Engineering 3 жыл бұрын
Plz make video on- Beam size .
@myengineeringsupport
@myengineeringsupport 3 жыл бұрын
Tomorrow will come pls wait
@krishna_raj9331
@krishna_raj9331 2 жыл бұрын
Hello sir, Are 12 mm 4 bars and 10 mm 2 bars enough in a 9*15 column..? The column to column distance is 15 feet. How many storeys can be built with this much reinforcement..?
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
2storey
@anilbagwe2542
@anilbagwe2542 2 жыл бұрын
Sir ji, Thanks for very knowledgeable information about concrete pillars. I have one query. Want to construct G 250 Sq ft +1 250 Sq ft small house adjacent to another nearby house. Adjacent house is ( ie it's flooring/plinth level) up side and propose construct land is 8' down side. Can you guide me if possible, in this connection how to build it. I will be building at my own. Thanks a lot for helpful information.
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
WhatsApp me
@hollywoodmovieclips8217
@hollywoodmovieclips8217 Жыл бұрын
Sir low rise buildings mid rise buildings hai rise buildings kitne floor
@shubhankarkirttania4564
@shubhankarkirttania4564 2 жыл бұрын
Sir can I use 8" X 12" coloum with 4 iron bar of 16mm and 2 iron bar of 12mm Tata tiscon 550 SD for G+2 building? Distance between two coloum pillar 9 ft to 10 ft. Sir please reply🙏
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
No
@helpmetoreach10kwithoutany14
@helpmetoreach10kwithoutany14 2 жыл бұрын
Yes
@beautyofbengal2907
@beautyofbengal2907 2 жыл бұрын
May I use 4 nos 16 mm rod for 10"×10" column and beam for two storey house?
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
Yes you can
@modanidarshana4247
@modanidarshana4247 2 жыл бұрын
Roof beam and slab Ka BHI banaye AISA video
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
Already available on channel pls check
@fitnessfactory7410
@fitnessfactory7410 Жыл бұрын
Thank you sir❤
@Jaishreeram0751
@Jaishreeram0751 2 жыл бұрын
सर 16mm me total 13 पिलर 10" × 14" खड़े हैं और लगभग 1302 स्क्वायर फीट 21 × 62 मकान में जिंदल पैंथर का सरिए का उपयोग किया गया है तो कितने मंजिल तक ले जाना चाहिए
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
Kitne baar hai
@Jaishreeram0751
@Jaishreeram0751 2 жыл бұрын
@@myengineeringsupport सर 6 सरिए है एक पिलर में और लगभग 7 फुट की नींव रखी है
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
Ok h
@Jaishreeram0751
@Jaishreeram0751 2 жыл бұрын
@@myengineeringsupport sir kitni manjil banani chahiye yah Janna chahta hoon
@rajkumar24352
@rajkumar24352 2 жыл бұрын
2 flor 1800 square feet home mein के पिलर में कितने सरिया और कितना mm का सरिया डालना चाहिए ?
@myengineeringsupport
@myengineeringsupport 2 жыл бұрын
Minimum 4nos. @12mm
А что бы ты сделал? @LimbLossBoss
00:17
История одного вокалиста
Рет қаралды 9 МЛН
How I Turned a Lolipop Into A New One 🤯🍭
00:19
Wian
Рет қаралды 10 МЛН