How to Wire a Linear Access Control System

  Рет қаралды 63,162

Nelly's Security

Nelly's Security

Күн бұрын

Пікірлер: 49
@robertmcgehee949
@robertmcgehee949 Ай бұрын
Trunk slammer special right there!
@Ernesto-p4o
@Ernesto-p4o Жыл бұрын
Don’t ever rely on you panel or software to unlock you door with a REX button, ALWAYS wire the REX button in series with your lock!
@wchurchill419
@wchurchill419 Ай бұрын
Facts
@erichogan9769
@erichogan9769 2 жыл бұрын
wish i had seen a video like this when I was installing mine
@joshbeasley21
@joshbeasley21 5 жыл бұрын
Your maglock is on the unsecure side of the door. Also no anchor or retro box was used, I could easily take the reader off the wall, short the power wires together and everything on that circuit will now have no power, not to mention that reader port on the controller is now fried.
@andyharris3084
@andyharris3084 4 жыл бұрын
I was thinking exactly the same on watching this video.
@JS.990
@JS.990 4 жыл бұрын
Its a demonstration not an actual job site.
@aduemmanuel1284
@aduemmanuel1284 4 жыл бұрын
Good job
@samaadkhan
@samaadkhan 2 жыл бұрын
Amazing bro
@statracing1
@statracing1 11 ай бұрын
We currently have a Linear 212SE, can we use that is conjunction with this unit so we can change pin codes remotely?
@michaelknight2897
@michaelknight2897 2 жыл бұрын
Is it possible to wire in a switch (lock/unlock) to the mercury board? The door is on a schedule, but the office person wants to lock it when they are out of the office and doesn't want to manual locks.
@peterwilson4871
@peterwilson4871 2 жыл бұрын
With you mag lock install you forgot to install the locating pins on the armature it is also to low to get a seal on a monitored mag lock
@GrenPara
@GrenPara 4 жыл бұрын
Pretty Good video. Thou did not cover type of Reader wire, gauge, shielded or non-shielded , twisted pair or regular. Do not be lazy! wires should be soldered and then heat shrinked and then taped to prevent damage from running new lines or removal.
@paulm4745
@paulm4745 5 жыл бұрын
if i wanted to wire an automatic gate to the system, would i use just and 18/2 from control panel to automatic gate panel? If so, where on automatic gate panel would i wire it to? thanks
@NellysSecurity
@NellysSecurity 5 жыл бұрын
Hi Paul, Im not sure where you would wire it to the gate panel but it should be doable.
@joshbeasley21
@joshbeasley21 5 жыл бұрын
Paul, you would wire it to the open command on the gate Operator. Every gate operator has a open, close, and stop terminal. So a wire from the strike relay if using a card reader, or a N/O Input if your wanting to open the gave via stationary button or through software. Very simple, the gate just needs a contact closure to open.
@-ProSystem
@-ProSystem 2 жыл бұрын
This reader can be changed to a Barcode Scanner .. ?!
@maximumwoof8662
@maximumwoof8662 5 жыл бұрын
those blue things are called "wire nuts"
@JS.990
@JS.990 4 жыл бұрын
Idk why a lot of low voltage technicians still use wire nuts, i use Dolphin Crimp connectors.
@Star-kp8oc
@Star-kp8oc 4 жыл бұрын
J Sanchez yup blue dolphins does the trick.
@steve7680
@steve7680 4 жыл бұрын
Does the Linear have a place for the Red and Green LEDs from the Card Reader? (Brown and Orange wires)
@NellysSecurity
@NellysSecurity 4 жыл бұрын
Wiring diagram shows LED terminal for each door.
@jeromeswaby5261
@jeromeswaby5261 3 жыл бұрын
Hello there I need some help I have the same power supply and mag lock that's in the video I'm installation it on my gate the drive way is about 100 feet long from the house when ever I try to ring the door bell from the gate it doesn't ring and the mag locking force is weak the wire am using is CAT 5 and the power supply is in the living 5AMP power supply am using!
@nicholasgaribay1758
@nicholasgaribay1758 3 жыл бұрын
Your using the wrong wire cat5 or cat 6 is usually used for cams and data. You need 18/6 or 18/4 stranded wire you can find some at an electrical supply house
@jeromeswaby5261
@jeromeswaby5261 3 жыл бұрын
Ok thanks question the 18/6 or 18/4 how many wires are inside the wire?
@nicholasgaribay5831
@nicholasgaribay5831 3 жыл бұрын
@@jeromeswaby5261 It is as it says 18 gauge 6 strand 18 gauge 4 strand
@jeromeswaby5261
@jeromeswaby5261 3 жыл бұрын
@@nicholasgaribay5831 ok thanks
@RacelifeCo
@RacelifeCo 5 жыл бұрын
What happens in the event of a power failure? Does your door unlock if there's no power to the building?
@NellysSecurity
@NellysSecurity 5 жыл бұрын
It depends on how you have it setup. If it is "Fail Safe" that means it will unlock when power is cut. If "Fail Secure", doors will remain locked when power is cut.
@RacelifeCo
@RacelifeCo 5 жыл бұрын
@@NellysSecurity would that require a battery backup then?
@NellysSecurity
@NellysSecurity 5 жыл бұрын
@@RacelifeCo A battery backup is always good on a Access Control system, but worse case if a battery backup dies, thats when fail safe and fail secure come into play.
@maximumwoof8662
@maximumwoof8662 5 жыл бұрын
if it's a mag lock, it's "fail safe"... no power, no lockey...
@chrisp1850
@chrisp1850 4 жыл бұрын
I'm running into issues where my circuit boards are no longer powering up. This happened after a failed battery backup.
@NellysSecurity
@NellysSecurity 4 жыл бұрын
Hey Chris, id recommend reaching out to our support - customerservice@nellyssecurity.com / 855-340-9999
@emmannew6740
@emmannew6740 4 жыл бұрын
Can you connect access to auto ops?
@NellysSecurity
@NellysSecurity 4 жыл бұрын
If it has NO/NC switch you should be able to. Also depending on the type of operation you are looking for.
@noushadup9347
@noushadup9347 4 жыл бұрын
Videos was helpfull but Very annoying sound
@NellysSecurity
@NellysSecurity 4 жыл бұрын
thanks for watching
@garretthigginbotham6122
@garretthigginbotham6122 3 жыл бұрын
WEEEOOOOOWEEEEOOOWEEEEEOOOO
@everywhereed362
@everywhereed362 4 жыл бұрын
Any video on how u run the wire
@NellysSecurity
@NellysSecurity 4 жыл бұрын
Unfortunately we do Not and its mainly because every install is different.
@ekeneokafor3311
@ekeneokafor3311 4 жыл бұрын
what is the cable type you use for connecting reader to controller?
@NellysSecurity
@NellysSecurity 4 жыл бұрын
Recommended is 18 gauge stranded solid copper. so 18/6 or 18/4
@adriansanche1485
@adriansanche1485 2 жыл бұрын
Slap them mudrings on bro lol
@patersondash5531
@patersondash5531 Жыл бұрын
We hear the song more then you
@craigharmon5462
@craigharmon5462 Жыл бұрын
I like your videos except for the super loud annoying music at the beginning of the video. Why do instructional videos have these loud annoying music segways? I don't do the loud annoying music in my videos. I prefer not giving people headaches.
@NellysSecurity
@NellysSecurity Жыл бұрын
Understood Craig, We certainly have upped our production quality over recent years since releasing this video!
@royochola
@royochola Жыл бұрын
How about the demonstration of wiring on the table at least we know which cable is used where
小路飞和小丑也太帅了#家庭#搞笑 #funny #小丑 #cosplay
00:13
家庭搞笑日记
Рет қаралды 17 МЛН
Каха и дочка
00:28
К-Media
Рет қаралды 2,2 МЛН
Quando A Diferença De Altura É Muito Grande 😲😂
00:12
Mari Maria
Рет қаралды 37 МЛН
2023 Access control system update
35:29
NIC’S - SYSTEMS & ELECTRIC
Рет қаралды 28 М.
Top 10 Considerations When Choosing Access Control
22:16
Nelly's Security
Рет қаралды 3,9 М.
What is a Door Access Control System in Security / How It Works
4:07
Inaxsys Security Systems
Рет қаралды 14 М.
1 - Maglock Wiring Life Safety with Mercury Boards
13:34
Bob Brislin
Рет қаралды 6 М.
What is a Patch Panel? Do You Need One?
17:01
Budget Nerd
Рет қаралды 1,9 МЛН
How Access Control Systems Work | Point Monitor Corporation
5:41
Point Monitor Corporation
Рет қаралды 39 М.
How to setup zkteco mb460 access control system
10:13
Tech Inside Out
Рет қаралды 32 М.
小路飞和小丑也太帅了#家庭#搞笑 #funny #小丑 #cosplay
00:13
家庭搞笑日记
Рет қаралды 17 МЛН