No Heating HVAC Who blew up my Big Blue ?

  Рет қаралды 12,983

Anti DIY HVAC

Anti DIY HVAC

Күн бұрын

Пікірлер: 30
@albertmcalister9066
@albertmcalister9066 3 күн бұрын
I have seen condensing furnaces freeze vertical exterior drains because the condensate rate is so slow. The condensate pump will fill and kick on, and pump out into another place in the attic without the risk of freezing the drain line.
@Honestandtruth007
@Honestandtruth007 4 күн бұрын
WOW 😳🤯 Sir,....... You are still Working after Dark for the Call 🤙❤️👍 Really Commit for the Customer service
@brnmcc01
@brnmcc01 4 күн бұрын
Why take out a 90% furnace and put an 80% back in it's place? Is it because the attic can get below freezing? 90% furnaces don't work in unconditioned spaces, which is why to this day, nobody makes a 90%+ commercial gas package RTU. How you going to drain that condensate when it's 40 below zero out on the roof. LOL.
@ELITECLIMATESOLUTIONS
@ELITECLIMATESOLUTIONS 3 күн бұрын
I have a whole new respect for my big blue bottle. I had no idea that much engineering went into the little squirt.😂
@topher8634
@topher8634 4 күн бұрын
Black iron to copper to gas flex run through cabinet? A real brain surgeon indeed.
@Eddy63
@Eddy63 3 күн бұрын
The old gas & go Good little vid as usual Ted ... Thx
@stevenbennett9785
@stevenbennett9785 3 күн бұрын
Those plastic shells on the heat exchangers on those at known to crack. Looked like lots of rust in the furnace which is what I ha e seen on all those that bust. Eventually when they get large enough the pressure switch won't close.
@robalexander7348
@robalexander7348 4 күн бұрын
Thanks Ted, another job fix with no drama, for you on a cold night 👍 Au
@ewood88
@ewood88 4 күн бұрын
Wonder why the gas had been shut off? And you are right...a real genius put that pump outside the pan. A recipe for disaster.
@stevenvais4822
@stevenvais4822 4 күн бұрын
Not allowed copper in pa for gas line
@chesstime356
@chesstime356 4 күн бұрын
As always very nice video
@johnwalker890
@johnwalker890 4 күн бұрын
That must be a Jimmy Crackhorn furnace, and I don't care, situation, I heard about those kind of systems, Good job Ted.........
@2packs4sure
@2packs4sure 4 күн бұрын
I never knew they ever did induced draft ECM motors,,, what would have been the point ??
@Bob.W.
@Bob.W. 4 күн бұрын
Thanks.
@549BR
@549BR 4 күн бұрын
Our Ted keeping the Gamecocks nice and warm after hours.
@edwardlowery6510
@edwardlowery6510 4 күн бұрын
working with guests in the room low pressure temps @ 70 410 unit compressor will not run calling for heat will not take a charge should start jumped out low pressure switch to charge it blowin heat 2 flashes lps
@justinbeam81
@justinbeam81 4 күн бұрын
Very nice!!!
@potentialhvac6074
@potentialhvac6074 4 күн бұрын
Seeing copper gas lines in all your videos get me . Cant help but think it's crazy
@andrzejhajder6405
@andrzejhajder6405 Күн бұрын
Good evening. Just curious,what did you do with those variable motors . I have more and more those emc motors where they don't belong.
@sknight0391
@sknight0391 4 күн бұрын
😎👍
@gabrielstern4992
@gabrielstern4992 4 күн бұрын
Good work Ted geting him up and running but at a minimum you need to redo that gas line and offer that custumer a pump relocation and fix that flue pipe unless the custumer says replace whole system. But at least ted you gave him some warmth. And Ted yes whoever did that pipe work and gas line work was an idiot they looked like what we call around my way a ghetto rig job. That looked almost like if on a car using pvc for a car exhaust pipe come on now but at least you know that Ted and can fix it. Take care Ted.
@edwardlowery6510
@edwardlowery6510 4 күн бұрын
I need to remove all panels
@w.miller7282
@w.miller7282 4 күн бұрын
Old style gas shut off and a copper connecctor then a stainless connector going through the side of the furnace, talk about first class.
@JoeK200
@JoeK200 Күн бұрын
That was a little disappointing. You explained that the owner just purchased the property. Most likely the home inspector caught the exhaust flue pipe disconnected and shut down the furnace for safety reasons. I've seem gas simply shut down for safety as well as officially being tagged out. Gas should not have been turned on without a permanent fix to the exhaust flue.
@edwardlowery6510
@edwardlowery6510 4 күн бұрын
might be a pain
@Spec360
@Spec360 3 күн бұрын
Home inspector should get fired for that
@eric_seguin
@eric_seguin 4 күн бұрын
At 1:50 am its 70 degrees in Baton Rouge. No wonder you got so much crap. Your customers love you. Our owner went over to Latchel. They pay well but I'd rather have our old A/C guy. If it was minor like the gas being off he wouldn't even bill the owner. Latchel ain't nothin' but money grubbers.
@findme5270
@findme5270 4 күн бұрын
“Stop following me up here and go turn the damn heat on” We all think it
@ghostrider.13
@ghostrider.13 3 күн бұрын
What????? You sprayed the shutoff valve but didn't spray the gas valve itself. What was the damn use. You gave them the bandit special!!!! You did exactly what you talk about in every video. 😢
@UltraHydrophobiccoat
@UltraHydrophobiccoat 4 күн бұрын
Wear a mask man. I started to wear mask this year. Put your own health in the first place
Rental house has no heat
10:10
Anti DIY HVAC
Рет қаралды 8 М.
ICP igniter not available adapt overcome MacGyver
27:12
Anti DIY HVAC
Рет қаралды 10 М.
Why no RONALDO?! 🤔⚽️
00:28
Celine Dept
Рет қаралды 118 МЛН
Smart Sigma Kid #funny #sigma
00:33
CRAZY GREAPA
Рет қаралды 37 МЛН
LS Engine HUGE EXPLOSION Failure Tear Down LS3 429CI
16:37
Boosted Motorsports 2
Рет қаралды 1,4 М.
Make a $100 Amazon Diesel Heater Even Better With This Simple Trick
26:11
You're wasting money on heating! Use your A/C!
17:11
Tech Ingredients
Рет қаралды 780 М.
How To Check a Condenser Fan Motor - HVAC Training
11:38
HVAC Pioneer Controls
Рет қаралды 2,6 М.
Wrong Pipe for Heating Was Just the Beginning of This Hack Disaster Repair
22:28
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 23 М.
I Fixed a DEAD Hybrid and Made it Rechargeable
22:48
Just Call Me Eddie
Рет қаралды 221 М.
HVAC Silver Soldering vs Brazing vs Brazing While Flowing Nitrogen!
18:42
AC Service Tech LLC
Рет қаралды 97 М.
Gas Furnace unsafe carbon monoxide warning
15:11
Anti DIY HVAC
Рет қаралды 16 М.
Popping a 5000A Fuse
18:42
Photonicinduction
Рет қаралды 6 МЛН
Cast Iron repair
12:19
On Fire Welding
Рет қаралды 153 М.