One way slab Vs Two way Slab | மடிப்பு கம்பி Crank rods | Deekshi Homes

  Рет қаралды 37,045

Deekshi Homes

Deekshi Homes

Күн бұрын

Пікірлер: 51
@ramanlaxman9536
@ramanlaxman9536 2 жыл бұрын
எளிமையாகவும் புரியும் படி சொன்னதற்கு நன்றி 👍🏻
@pragha9113
@pragha9113 4 ай бұрын
Very informative video ,simply awesome,clear explanation 💐
@vnethirajan
@vnethirajan Ай бұрын
Super bro...arumaya sonninga!!!
@dvmuthukumarveluswamy9361
@dvmuthukumarveluswamy9361 2 жыл бұрын
Really Good explanation bro... Your knowledge transfer would be appreciated 👍
@deekshihomes
@deekshihomes 2 жыл бұрын
Thank you 🙏🏻
@sureshm8522
@sureshm8522 Жыл бұрын
Simple and clear explanation
@govind9329
@govind9329 Жыл бұрын
Very Nice. Well explained 👏 👌
@ranganraveena9830
@ranganraveena9830 12 күн бұрын
Explanation is nice sir
@priyasunil9738
@priyasunil9738 2 жыл бұрын
Do you undertake repair works for a commercial building?
@newtoncalls
@newtoncalls Жыл бұрын
Hari brother your voice sounds great 👍 when you are not facing the camera
@elumalaik8017
@elumalaik8017 2 жыл бұрын
Thank you so much sir very Usefull video
@swathi.n8871
@swathi.n8871 2 жыл бұрын
Hi Hari sir. Nice explanation. We are extending an additional room in our old house. Our new room is 10*8. Oru engineer said as area is small , crank on two sides of Lx (8 ft) will be enough. We have used paste to concel with old building on the Ly end (10ft end) ... Will this create any big issues?
@deekshihomes
@deekshihomes 2 жыл бұрын
From your data there is no issues in this
@swathi.n8871
@swathi.n8871 2 жыл бұрын
Thanks for the confirmation... No issues because the area is small? The crank concept of one way slab is followed in our two way slab room.
@deekshihomes
@deekshihomes 2 жыл бұрын
Yes as the area and load is very minimal not to worry about it
@Rajapostman6031
@Rajapostman6031 Жыл бұрын
Veettukku vasthu outer measurement pakkanuma illa inner measurement pakkanuma sir😊
@kumaragurug4698
@kumaragurug4698 3 ай бұрын
Very fantastic 👍👍
@praveenkumar-fo6sw
@praveenkumar-fo6sw Жыл бұрын
What would happen if we design a one way slab instead of two way slab room sizes are 17*11,10*10,7*9&9*8
@makeiteasy9723
@makeiteasy9723 6 ай бұрын
Thanks for info. for 10 ft x 6 ft room , 10/ 6 , ~ 1.6 so 2 way slab . for small room like this main and distributor rod 8 mm diameter is OK ? how it is decided for how much length 10 mm dia or 8 mm dia is OK ? Thanks
@jenilia7339
@jenilia7339 Жыл бұрын
Excellent sir...
@tilakareswaran576
@tilakareswaran576 Жыл бұрын
Useful sir 👍👏
@rxraja441
@rxraja441 10 ай бұрын
sema explain anna
@ariharan27
@ariharan27 Жыл бұрын
Crank point evolo vaikkanum sir
@veeramaniselvaraj
@veeramaniselvaraj 9 ай бұрын
One way slap க்கு 12mm×10mm பயன்படுத்தலாமா சார்?
@nagendranradhakrishnan4764
@nagendranradhakrishnan4764 Жыл бұрын
How to calculate the Crank distance is 1/3 or1/4.explain pl.
@iyyappang5444
@iyyappang5444 Жыл бұрын
Super
@_kid_kurama_43111
@_kid_kurama_43111 2 жыл бұрын
Tamilnadu la enga la ne v2 kati kudukiringa?
@KrishnaMoorthy-mq1jc
@KrishnaMoorthy-mq1jc Жыл бұрын
Super but Tamil la sollunga
@VenkatVenkat-pm2em
@VenkatVenkat-pm2em Жыл бұрын
2bhk plan &structural design kidaikuma
@deekshihomes
@deekshihomes Жыл бұрын
Reach us on whatsapp for drawings. 9940667567
@isaacraj5339
@isaacraj5339 2 жыл бұрын
Our hall room is 16*10 but crank also done and on center of both concealed beam also given on full length of room will this beam create any problems
@deekshihomes
@deekshihomes 2 жыл бұрын
Kindly share images in whatsapp @ 9940 667 567
@isaacraj5339
@isaacraj5339 2 жыл бұрын
@@deekshihomes it is already finished but we are going to build first floor so only
@RENACONBUILDING
@RENACONBUILDING Жыл бұрын
Crank degree + crank அடிச்சதுக்கு அப்புறம் டிஸ்டன்ஸ் எவளோ இருக்கனும் sir
@infinityTamilan
@infinityTamilan 2 ай бұрын
45 degree
@infinityTamilan
@infinityTamilan 2 ай бұрын
3 feet
@naveensj6
@naveensj6 Жыл бұрын
Bro , how many rods are required and at what inch we should place at anh methods kindly reply bro
@naveensj6
@naveensj6 Жыл бұрын
What size rods are required?? And what are their necessities??
@deekshihomes
@deekshihomes Жыл бұрын
For those you need to get structural drawing
@nilamakillifestyle4558
@nilamakillifestyle4558 Жыл бұрын
Sir marbles fix pannanum enna mathiri steps follow pannanum
@ajithcaxton7023
@ajithcaxton7023 Жыл бұрын
Sir any vacancy for your construction company
@deekshihomes
@deekshihomes Жыл бұрын
Mail resume to deekshihomes@gmail.com
@dharanidhamarai2545
@dharanidhamarai2545 Жыл бұрын
🙏👍👏👏👏👏👏🤝
@thirumalaivasant9322
@thirumalaivasant9322 2 жыл бұрын
Sp34 code book bro
@ismailkahn8607
@ismailkahn8607 Жыл бұрын
நான் மதுரை பக்கம்,,, உங்க நம்பர் கிடைக்குமா
@muthumani1170
@muthumani1170 2 жыл бұрын
Unga num solunga bro
@Rajapostman6031
@Rajapostman6031 Жыл бұрын
Unga contact number kedaikkuma sir
@makeiteasy9723
@makeiteasy9723 6 ай бұрын
Thanks for info. for 10 ft x 6 ft room , 10/ 6 , ~ 1.6 so 2 way slab . for small room like this main and distributor rod 8 mm diameter is OK ? how it is decided for how much length 10 mm dia or 8 mm dia is OK ? Thanks
@tilakareswaran576
@tilakareswaran576 Жыл бұрын
Useful sir 👍👏
Симбу закрыли дома?! 🔒 #симба #симбочка #арти
00:41
Симбочка Пимпочка
Рет қаралды 4,8 МЛН
Players push long pins through a cardboard box attempting to pop the balloon!
00:31
Two Way Slab Reinforcement
9:08
AK Skills & Solutions
Рет қаралды 1 МЛН
01.Structural Animation of One Way Slab Detailing
3:03
CE FUNDAMENTALS
Рет қаралды 29 М.
✅ Design of One Way Slab Reinforcement Details | Green House Construction
10:37
roof slab reinforcement work | shorter span , longer span பார்க்காமல் கம்பி பரப்பினால் என்ன ஆகும்!?
8:56
கண்ணன் முருகேசன். கட்டுமான பொறியாளர்.
Рет қаралды 5 М.
RCC roof slab crank எப்படி Mark செய்தல்
4:59
world Technology 100
Рет қаралды 18 М.
Симбу закрыли дома?! 🔒 #симба #симбочка #арти
00:41
Симбочка Пимпочка
Рет қаралды 4,8 МЛН