Orientation and Configuration of Danfoss VLT FC 051/ FC 360 / FC 101 Drives || Digicon Automation

  Рет қаралды 167,357

DIGICON AUTOMATION

5 жыл бұрын

|| Three wire start stop with speed POT application ||
Parameter list for Three wire start stop with speed POT application :
1-20 = Motor Power [kW] [hp]
1-22 = Motor Voltage
1-23 = Motor Frequency
1-24 = Motor current
1-25 = Motor Nominal Speed
3-15 = [ 1 ] Analog Input 53
3-16 = [ 0 ] No function
3-41 = Acceleration Time
3-42 = Deceleration Time
5-10 = [ 9 ] Latched start
5-12 = [ 6 ] Stop inverse

Пікірлер: 90
@vijaysharma-qn6nx
@vijaysharma-qn6nx 4 жыл бұрын
thanks sir..very important knowledge.....SV Electronnics Nanded maharashtra
@PraveenKumar-qr8mc
@PraveenKumar-qr8mc 4 жыл бұрын
Hello Thanks for the wonderful video. I'm using Danfoss VLT HVAC Basic Drive FC 101 and want to use pushbutton for speed up and down. But I noticed there is no terminal 33. As per the manuals, only model Danfoss VLT micro drive FC 51 and VLT automaton drive have terminal 33. Please advise how to use pushbutton for speed up and down for Danfoss VLT HVAC Basic Drive FC 101. Thank You
@michaelnasief9245
@michaelnasief9245 Жыл бұрын
Dear i have danfoss FCM 305 - with worming indicated local stop - i tried every thing - can you help
@sdengineers1742
@sdengineers1742 3 жыл бұрын
AM DL Sharma From Rajasthan Am Use FC 360 Drive . Our issue We Use Control card In 5.5 hp DRIVE then Run The Drive But Used this Control Card in 1.5 kw 2hp then COME Al 38 Same Control Card Run in 5.5 hp But 2 hp Not Run come Al 38 so Plz Tell How to Remove Al 38 In Control Card.
@DIGICONAUTOMATION
@DIGICONAUTOMATION 3 жыл бұрын
Alarm 38 for Internal fault, You need to update the software version of VFD to reset this Alarm
@jaiprakashgupta3332
@jaiprakashgupta3332 Жыл бұрын
i want to know about terminal 20 and 33 setting i am using this terminal for over limit
@Bharataryans
@Bharataryans Жыл бұрын
How can we replace it with old drive of commercial trademill ??
@subdaralam5050
@subdaralam5050 3 жыл бұрын
Sir jaise Ham bahar se start stop push button use karnah aur drive ka potential use karna hai
@MrMsJomol
@MrMsJomol 3 жыл бұрын
is there any ready signal form vfd for programing with plc?
@peternauta
@peternauta 3 жыл бұрын
Which language is this?
@DIGICONAUTOMATION
@DIGICONAUTOMATION 3 жыл бұрын
Hindi
@sharifhossain8830
@sharifhossain8830 3 жыл бұрын
Direction of rotation parameter which one? Forward or Reverse or Both Thanks
@gauravsharma-gc4cp
@gauravsharma-gc4cp Жыл бұрын
Sir humari company mai danfoss vfd ,wo phase loss dikhata hai bar bar ,humne output cables aur motor check ki okay hai,shi chalti h lekin 2 -3 gnte m fault aata hai isko reset kese kre
@gurpreetsinghpreet3280
@gurpreetsinghpreet3280 Жыл бұрын
Very very nice sir.
@ppremkumarpremkumar6822
@ppremkumarpremkumar6822 3 жыл бұрын
How to connect digital scaling meter and program in danfoss vfd
@PDQknives
@PDQknives 4 жыл бұрын
Thanks you, great video! I need to run a motor up to 70 Hz using an external potentiometer, and i can't do it. 3-15 parameter is in "1" already. The motor gets to 50 Hz. Do you know what could be happenning? Thanks!
@DIGICONAUTOMATION
@DIGICONAUTOMATION 4 жыл бұрын
thank you.. You need to set three parameters...as per below, 3-03 = 70 Hz 4-14 = 70 Hz 6-15 = 70 Hz
@PDQknives
@PDQknives 4 жыл бұрын
@@DIGICONAUTOMATION Thank you very much!
@ultimatesolution9935
@ultimatesolution9935 Жыл бұрын
​@@DIGICONAUTOMATIONbut sir motor may get hot ,I think
@eyadadel1959
@eyadadel1959 3 ай бұрын
Hi Dear How to get the registers addresses of the fc101 vfd
@drprajapati7147
@drprajapati7147 3 жыл бұрын
yes good
@shubhambhardwaj2687
@shubhambhardwaj2687 2 жыл бұрын
Sir. Who is relay trip parameters in vlt micro drive 51
@consoultechnical1688
@consoultechnical1688 3 жыл бұрын
Sir fc51 drive mein samne display mein rpm kaise dekhenge.
@anirbanghosh1592
@anirbanghosh1592 4 жыл бұрын
dear sir, in circuit diagram u have shown that latched start to terminal no 12,do it means a continuous nc puls should be given at point 12 or one time nc pulse is required
@DIGICONAUTOMATION
@DIGICONAUTOMATION 4 жыл бұрын
Terminal 12 is for +24V supply, where for latched start we used a terminal no. 18
@ultimatesolution9935
@ultimatesolution9935 Жыл бұрын
Friend,really terminal 12 is a source of +24vdc
@lalbabuyadav8023
@lalbabuyadav8023 2 жыл бұрын
Ek problem hai Please help me Danfoss fc360 hai usme ek. Warning 7aa raha hai
@manjulakarunathilaka7949
@manjulakarunathilaka7949 11 ай бұрын
👍👍❤ thanks frind
@ganpatmungase8517
@ganpatmungase8517 5 жыл бұрын
Dear sir whats difrants in - FC -051, FC360 and FC - 101
@boobathirajaduraisamy5155
@boobathirajaduraisamy5155 4 жыл бұрын
FC101 Refrigeration Drive most used in chillers, Air-conditioning, FC051 is Small Application used automachine drive, FC360 is Fan application and Pumb application Specifically used and number of digital input is high. Basic different is Different firmware and parameters used in the drive You want any help please Call 8637641293 I will guide you, Currently I am working in danfoss drives..
@suncontrols1884
@suncontrols1884 4 жыл бұрын
hi im velu from sun controls bangalofre . i have one doubt my danfoss vfd showing overcurrent error without conneting motor wht is the issu plesae help me
@DIGICONAUTOMATION
@DIGICONAUTOMATION 4 жыл бұрын
Okay sir, you have to do factory reset your VFD. kzbin.info/www/bejne/bYOkq4Sbjtmnqrs
@suncontrols1884
@suncontrols1884 4 жыл бұрын
Thank u for reply...one more doubt if I do factory reset all saved data will be delete or only alarm will delete?
@DIGICONAUTOMATION
@DIGICONAUTOMATION 4 жыл бұрын
@@suncontrols1884 All data will be deleted
@rahuldeo7892
@rahuldeo7892 4 жыл бұрын
I have 7.5 hp danfoss fc51 and it taking 4 to 20 ma frequency command but after power trip vfd is not taking 4 to 20 ma command and there is any alarm and i have connected 55 and 60 number terminals. Please suggest me how do i check and what is parameters of 4 to 20 ma for plc or pid and 0 to 10 volt for 10k port.
@ultimatesolution9935
@ultimatesolution9935 Жыл бұрын
Dear friend, According to me, For 4-20ma 3-15......[2] For start command you can select 5-10....[8] 6-22....4ma 6-23...20 ma Rest keep default settings Connection diagram: Term. 60 ...... + Term.55......... - Connection of start command Between term.12 and Terminal 18.....NO contact. Rest on your feedback
@mahmoodbhaijaan4062
@mahmoodbhaijaan4062 4 жыл бұрын
sir muje motor ki frequency badaani hai konsa parameter hai
@DIGICONAUTOMATION
@DIGICONAUTOMATION 4 жыл бұрын
Parameter 3-03 = Max. frequency that you want Parameter 4-14 = Max. frequency that you want
@ZeeshanSiddique-b7k
@ZeeshanSiddique-b7k 8 ай бұрын
Very Good working
@mohammedeathesham2151
@mohammedeathesham2151 3 жыл бұрын
Dear sir, You explaination was very simple and good. I am facing one similar problem at site can you please help me out. When i am starting the motor it's frequency is directly going to 50hz. I want to control the frequency from 20hz and as vtg increases frequency should also increase. Can you please guide me to do the settings for the frequency.
@ultimatesolution9935
@ultimatesolution9935 Жыл бұрын
अगर आप FC 51 use kar rahe hai to Parameter 4-12........motor speed low limit Aur 3-02......minimum reference check check kare Inme aap 50hz rakhe hue hai.isko 0 ya kuchh rakhe jisse aap start Karna chahte hai.
@यादवजी-च4स
@यादवजी-च4स Жыл бұрын
Brak Ragister ka use kha kiya jata hy 😊
@adrianacastaneda5548
@adrianacastaneda5548 3 жыл бұрын
Buen día. Será que me podrías apoyar con los parámetros y conexión que debería utilizar para un alternado de dos variadores con transductor? Es decir que encienda uno, se para y encienda el segundo, luego se pare y encienda nuevamente el primero etc 🙏🏻
@sonajipohne2359
@sonajipohne2359 3 жыл бұрын
Dear Sir Danfoss drive FC 102 This driver problem is .... Short circuit (16A) on display How to solve this problem Plz help me sir
@TarunKumar-fv2gh
@TarunKumar-fv2gh 2 жыл бұрын
Please send your mail I'd
@rajeshmondal2424
@rajeshmondal2424 4 жыл бұрын
So good
@drprajapati7147
@drprajapati7147 3 жыл бұрын
We have Danfoss ac Drives FC 51 -micro drives ASD ENGINEERING DELHI-92
@rameshpatil8065
@rameshpatil8065 5 жыл бұрын
very helpful video
@samisk2169
@samisk2169 2 жыл бұрын
Hello my friend, well done for posting
@sandeepkaushik1998
@sandeepkaushik1998 4 жыл бұрын
Sir delta drive ke auto/manual ckt ke bare me bi btaoge.sir plz
@_keshav004
@_keshav004 Жыл бұрын
Please guide on automation drive.
@ultimatesolution9935
@ultimatesolution9935 Жыл бұрын
Danfoss me multistage speed ke baare me video banaye.
@prlove3845
@prlove3845 Ай бұрын
Sir. Please selection Krna sikhaye
@ManojKumar-xm3oi
@ManojKumar-xm3oi 5 жыл бұрын
Sir Dc Se chalane keley kaya program danlna padega
@DIGICONAUTOMATION
@DIGICONAUTOMATION 5 жыл бұрын
Kitne volt DC?
@boobathirajaduraisamy5155
@boobathirajaduraisamy5155 4 жыл бұрын
If you have 3 * 560vdc ,you give to Drive get Ac output
@ratneshtripathi1095
@ratneshtripathi1095 2 жыл бұрын
Vlt 5000 ka revars and farvard fara mitar sir
@dibyaranjanbehera6366
@dibyaranjanbehera6366 2 жыл бұрын
Frequency kaise badha te hain
@harpreetsingh2696
@harpreetsingh2696 4 жыл бұрын
ID Run ka kya parameter ha sir
@niksontalan5803
@niksontalan5803 4 жыл бұрын
Hello mr.can you make totorial vidio how seting parameters vfd motor dc for me..?
@engineeraliahmadsabir2382
@engineeraliahmadsabir2382 3 жыл бұрын
Good
@classicwheelsunited
@classicwheelsunited 3 жыл бұрын
Hi there! I am interested on the Digicon Start/Stop panel. Does it have a part number or can you tell me where to buy it? Best regards, Istvan
@harshpanchal3372
@harshpanchal3372 5 жыл бұрын
Nice video 👍
@guddumoriya5258
@guddumoriya5258 Жыл бұрын
Lock or unlock kaise kiya jaaye
@supanditroy7191
@supanditroy7191 2 жыл бұрын
Frequency wrong show ho raha
@sanjuaher2181
@sanjuaher2181 3 жыл бұрын
Sanjay Aher
@lalbabuyadav8023
@lalbabuyadav8023 2 жыл бұрын
Hi good morning
@pramodkumarmandal7940
@pramodkumarmandal7940 4 жыл бұрын
Password laga ho to kai se parameter set kare ge
@chaudharykaif
@chaudharykaif 3 жыл бұрын
Port ka parameters tobbataye hi nahi
@DIGICONAUTOMATION
@DIGICONAUTOMATION 3 жыл бұрын
For POT, If u connect the wire on terminal 53 then set [1] on parameter 3-15..
@chaudharykaif
@chaudharykaif 3 жыл бұрын
@@DIGICONAUTOMATION thanks sir
@chaudharykaif
@chaudharykaif 3 жыл бұрын
@@DIGICONAUTOMATION vfd037M43A display pe hpf dhikha raha hai to kaya problem hai
@DIGICONAUTOMATION
@DIGICONAUTOMATION 3 жыл бұрын
@@chaudharykaif Can u share a picture ?
@chaudharykaif
@chaudharykaif 3 жыл бұрын
Picture kis pe share karo
@radhikavermaofficial1811
@radhikavermaofficial1811 5 жыл бұрын
Vlt 2800 parameter setting
@boobathirajaduraisamy5155
@boobathirajaduraisamy5155 4 жыл бұрын
You want Any Special parameter, Which application parameter.
@syedtayyab2411
@syedtayyab2411 4 жыл бұрын
Sir aap ka no milega kya
@machagiriprasad2305
@machagiriprasad2305 4 жыл бұрын
Wiring vfd to motor
@sharandeep6819
@sharandeep6819 3 жыл бұрын
S,haran
@varatharajvaratharaj1635
@varatharajvaratharaj1635 Жыл бұрын
Over load production setting
@asifsaifi6122
@asifsaifi6122 3 жыл бұрын
Kisi Koo old VFD chaiye too muje reply karke mujse baat kar skte hoo
@aaronelieservalenzuelamart2734
@aaronelieservalenzuelamart2734 4 жыл бұрын
En español por fa