OT skills guide: Jackson Cross Cylinder

  Рет қаралды 97,507

Optometry Today

Optometry Today

Күн бұрын

This video takes you through the technique and theory of using the Jackson Cross Cylinder to determine a patient’s astigmatism. This is used after determining the best vision sphere.
For the latest from OT : www.aop.org.uk/ot
Follow us
/ optometrytodayjournal
/ optometry_today
/ optometrytoday

Пікірлер: 32
@Mango037
@Mango037 4 ай бұрын
As a patient, this helps reduce the anxiety of choosing. It has helped me have better understanding on what is the purpose of this phase scientifically. I don’t have astigmatism but my child does. Thank you for sharing this valuable information. Now I look forward to our next Ophthalmology visit.
@otiebrown9999
@otiebrown9999 Жыл бұрын
It is good to see the debate on the difficulties of measuring cylinder- accurately.
@camelCased
@camelCased 10 ай бұрын
Important bit when dealing with patients who have seriously impaired vision since birth (nystagmus, ocular albinism, such as myself). They might have a very weak ability to judge the specific direction of lines in the distance. So, for example, if a patient who has problems with distinguishing vertical lines clearly is being asked if the circle looks sharper with lens one or two, they might base their reply solely on the horizontal-ish parts of the circle. They will have a very hard time deciding if the circle has become rounder or not because the vertical parts will look blurry to them because of their nerve-brain issues, so no lens can fix those. This might make subjective refraction much more difficult when you know that the patient sometimes is confused and might start giving conflicting answers when it comes to dealing with correction at more vertical angles.
@astemet
@astemet 11 ай бұрын
It was really useful to mee.. i was so confused about my degrees for cil
@tabelangbrendainbrendain4110
@tabelangbrendainbrendain4110 4 жыл бұрын
This really helped a lot we hope for many more videos
@nsr2839
@nsr2839 Жыл бұрын
Hi , I have a doubt in +1 blur test , Is it not necessary that patient should read 6/18?
@Lapata511
@Lapata511 11 ай бұрын
I don’t think so. It should be above four line
@rehmanakudi68
@rehmanakudi68 4 жыл бұрын
I don't think it's a good way of teaching JCC...we were taught a much better way by professor Barratt and Prof Elliott at Bradford uni...check his book out... Primary Eye Care. Not saying this is wrong...just over complicating what in essence is a pretty simple task.
@SharrpDesigns
@SharrpDesigns 3 жыл бұрын
Do you check cyl power first or cyl axis first? Which one do you start checking at the beginning.
@fahdhanif3046
@fahdhanif3046 3 жыл бұрын
@@SharrpDesigns cyl axis first usually
@ВоронМаусы
@ВоронМаусы 2 жыл бұрын
Do you leave the -0.25 (that you include for the JCC in the beginning) as part of the prescription, or do you remove it after the process is finished?
@vic-arenal7634
@vic-arenal7634 2 жыл бұрын
What if a patient did not report axis as equally clear but one to be clearer than the other, were by you will begin to go back and forth what axis should be used.
@francesko3640
@francesko3640 Жыл бұрын
anna de armas
@bobjobjoe8887
@bobjobjoe8887 4 жыл бұрын
6:10 \o/
@ugochinnamdi9275
@ugochinnamdi9275 7 ай бұрын
Could have been a great video but you were too fast. Thank you all the same
@CuriousDrifter
@CuriousDrifter 9 ай бұрын
The circle of least confusion was already placed on the retina at the end of the last video (best sphere) and verified by the duochrome test, why do we need to over minus the patient by -0,.25 before using JCC?
@MrGeriausias
@MrGeriausias 7 ай бұрын
This helps to ensure that the circle is on a retina, because accommodation will bring the circle on retina
@d.perera7875
@d.perera7875 2 ай бұрын
@@MrGeriausias But doesn't the eye need to be at accommodation rest for the whole subjective refraction? Why don't we just leave the circle on the retina by best vision sphere?
@MrGeriausias
@MrGeriausias 2 ай бұрын
@@d.perera7875 Once the cylinder is set, you will adjust the sphere again. You can refine the sphere using the +-0.25 technique. After that, you will move to the next eye.
@d.perera7875
@d.perera7875 2 ай бұрын
@@MrGeriausias Okay but why overminus at all? Isn't the circle of least confusion on the retina by the BVS? Why force the eye to accommodate?
@MrGeriausias
@MrGeriausias Ай бұрын
@@d.perera7875 BVS should bring the CoLC on the retina. However, there is a chance that a patient made a mistake in deciding which sphere is clearer. If you are not 101% sure that the CoLC is on the retina, it is safer to over-minus myopes and under-plus hyperopes cause accommodation will bring the CoLC on the retina. Over-minus myopes and under-plus hyperopes is a harmless extra step that fulfills the CoLC requirement of JCC test.
@ansuneldelarey3898
@ansuneldelarey3898 3 жыл бұрын
You don't leave the patient on "red best" to start "over minus" them.... you over minus them before JCC but that would be green best?!
@raptorial3447
@raptorial3447 Жыл бұрын
you hand hesitates yoo much so I think axis in 45 degree was not accurate but geberally thx for illustrate
@alibahari8480
@alibahari8480 Жыл бұрын
Great video
@ophthojooeileyecirclehisha4917
@ophthojooeileyecirclehisha4917 Жыл бұрын
thank you so much
@ghassansalih2347
@ghassansalih2347 3 жыл бұрын
Thank you.. great help
@davidjyothiopticals7699
@davidjyothiopticals7699 2 жыл бұрын
Super TQ madam
@m.a4491
@m.a4491 4 жыл бұрын
3:00 that's wrong! The position of handle should be parallel to trial cyl...
@loulbelay2464
@loulbelay2464 3 жыл бұрын
it’s only supposed to be parallel when you’re refining the power, not when you’re refining the axis
@ВоронМаусы
@ВоронМаусы 2 жыл бұрын
@@loulbelay2464 different way around
@barrettmomo311
@barrettmomo311 4 жыл бұрын
Merci infiniment 🙏🙏
OT skills guide: Best vision sphere
10:11
Optometry Today
Рет қаралды 16 М.
2024 Community Lecture Series: Optical Shop
49:23
UCI Health Gavin Herbert Eye Institute
Рет қаралды 3,9 М.
An Unknown Ending💪
00:49
ISSEI / いっせい
Рет қаралды 56 МЛН
escape in roblox in real life
00:13
Kan Andrey
Рет қаралды 90 МЛН
Cross Cyl Right Eye
9:19
Ian Squire
Рет қаралды 134 М.
OT skills guide: Applanation tonometry
16:22
Optometry Today
Рет қаралды 125 М.
8.02x - Lect 1 - Electric Charges and Forces - Coulomb's Law - Polarization
47:13
Lectures by Walter Lewin. They will make you ♥ Physics.
Рет қаралды 4,2 МЛН
Jackson cross cylinder
8:22
AP's Ophthalmology pearls
Рет қаралды 52 М.
OT skills guide: Fan and block
9:05
Optometry Today
Рет қаралды 8 М.
Home Eye Test! If you fail, see an EYE DOCTOR!
6:17
Michael Chua, MD
Рет қаралды 3,1 МЛН
OT skills guide: Slit lamp routine
8:23
Optometry Today
Рет қаралды 15 М.
JCC - Axis and Power
14:47
Christopher Clark
Рет қаралды 12 М.
An Unknown Ending💪
00:49
ISSEI / いっせい
Рет қаралды 56 МЛН