Outdoor PVC Conduit

  Рет қаралды 22,529

MrMotofy

MrMotofy

Күн бұрын

Brief overview of how to run or connect some PVC conduit outside in the ground for power or low voltage like coax(TV/Sat), Cat 6vor Fiber for computer networks
My VID Playlists / mrmotofy
For Professional contact email me at LearnToLiveLifeYouWant @ G mail .com (Remove Spaces)- Trying to avoid the Spam bots
Keywords: All Top, SmittyBilt, ARB, VIAIR, Train Horn, Onboard air, impact, Toyota, Jeep, Fiat, Ford, Raptor, Suzuki, Michelin, Yokohama, Cherokee, Vixen, Craftsman, California Air Tools, Makita, Fortress, Fortnite, Dewalt, Air Command, Tacoma, Yamaha, Hornblaster, XTM, T-Max, Projecta Typhoon, 4Runner, Samurai, Kleinn, Firestone, Airlift, Airbags, air suspension, airmaxxx, air compressor, 12v air compressor, 12v, 24v, 48, Jackery, Bluetti, solar generator, Battleborn, Lithium, Hemi, Cummins, Ram, Bronco, Jeep, Chevrolet, Chevy, Duramax, 6.6, 3.0, Ford, Powerstroke, Dodge, Cummins, 12v, 24v, Detroit, Cateye, LMM, LLY, LB7, LML, L5P, 6.0, 6.4, 6.7, International, 2500, 3500, 1500, Exhaust, Fummins, Whistlin Diesel, Cleetus, McFarland, HeavyD, Diesel Dave, Diesel, Fass, Airdog, Turbo, GMC, Boost, Camaro, Firebird, Corvette C8, C6, C5, Nova, Caterpillar, Allison, Milwaukee, batteries, Lithium, solar, Renogy, Rich Solar, Eco-Worthy, Canadian Solar, Trina, SunPower, Victron, Midnight, Magnum, Outback

Пікірлер: 18
@joshgross8741
@joshgross8741 28 күн бұрын
you are the man!
@mrmotofy
@mrmotofy 28 күн бұрын
AAAAAWE shucks, I'm blushing
@whythehec
@whythehec 5 ай бұрын
If i didnt have access to dig a trench would i be able to run this along an extrior wall into a detached garage?
@mrmotofy
@mrmotofy 5 ай бұрын
Yes, trenching is useful but not always the right option depending on the situation. This is rated for outdoor exposure. It can also rather easily be painted to blend into the wall/house color. Helps to scuff surface slightly so it's not shiny then paint before installation for ease. Just need to clean paint off any joint areas. Then touch up after completion. Also run larger than you think you need. Say 1" bare minimum for data and 1 1/2" for power. They need to be separate if you didn't know. Also helps to get a deburring tool (plumbing dept normally) and deburr the inside edge corner of each pipe section. Helps to smooth transition for easier wire pulling. Read some of the other comments for more tips
@jasona4881
@jasona4881 6 ай бұрын
Great video. What size pilot hole would be required for a 1/2 LB box?
@mrmotofy
@mrmotofy 6 ай бұрын
I don't know the size offhand, I always use 3/4" minimum. Ya always need more space. If you're at the store buying parts grab a tape measure and measure what ya need.
@Ramser03
@Ramser03 Ай бұрын
Great thank you, this had all the basic info I needed
@mrmotofy
@mrmotofy Ай бұрын
@@Ramser03 awesome glad it helped you
@jamesvoong3125
@jamesvoong3125 10 ай бұрын
What type of electrical wires would you used from the inside the house and thru the conduit to the other structure
@mrmotofy
@mrmotofy 10 ай бұрын
Depending on what you're running through there. Ideally 2" conduit for power is a good option for easy pulling. Otherwise 1 1/4" for low voltage normally will work well. Power needs to be a separate conduit than low voltage like internet. Most power singular stranded wire sold in home stores now is the proper type. But basically you're looking at THWN or could say like USE 2 on it. Basically rated for wet conditions. Consult your local electrical codes for requirements Many times Mobile Home Feeder, SE-R, or may be Service Cable, can be used and is cheaper. It's 2-2-2-4 Alum, has 3 main conductors and the ground all in a grey plastic insulation coating. Can always have larger wires than needed for a circuit. The ground is not used for a detached structure. It needs it's own 2 ground rods for best results. Consult your local electrical codes. Singular wires can't run through a normal wall, so using regular stranded wire in the conduit would require transitioning to something different or running conduit all the way through walls etc. Using the MH SE cable eliminates the connections since it's rated for nearly any conditions. Essentially you want to run a sub panel in the detached structure. Which will be 240v and then the panel separates to 120v circuits. Makes additions later very convenient too. If you're doing low voltage like network/internet it should be exterior rated or gel filled holds up the longest. Outdoor in ground runs for internet in the past has been cat 5/6 type cable. But due to grounding issues and static charges one should use fiber optic cable. It's frequently cheaper than copper and isn't hard to work with. Preterminated cables are available and can be longer since length isn't really an issue like with copper. Lot's of YT vids of what to get and how to do it. FS dot com is a very reputable fiber equpipment seller in the US and good prices. Otherwise Monoprice dot com also If you've never worked with conduit before there's lot's of vids on tips and tricks like using a shop vac and pull rope with piece of rag or plastic bag attached to pull it through. Essentially the same principle bank driveup vacuum tubes work. Then attach wire and pull through.
@stormbytes
@stormbytes 4 ай бұрын
Very helpful, thank you!
@mrmotofy
@mrmotofy 4 ай бұрын
You're welcome
@turtlebuster82
@turtlebuster82 5 ай бұрын
Thank you!
@mrmotofy
@mrmotofy 5 ай бұрын
You're very welcome hope it helped clarify
@sagegriot2455
@sagegriot2455 2 ай бұрын
Are you holding the slip fitting upside down? Seems like the larger OD section should be oriented above the smaller section to keep water out.
@mrmotofy
@mrmotofy 2 ай бұрын
@@sagegriot2455 The fittings will only go one way to make this work. The glue will keep water out.
@DrCSagan
@DrCSagan 6 күн бұрын
Yes, he was holding the slip joint upside down. There is no glue along the movable section -- it's sealed with n o-ring. It's relatively air & water tight, but you should mount it so that the larger diameter piece is on top so that water can't pool in the fitting. It would explain this in the manufacturer's instructions, which are always good to read, no matter how many youtube videos you watch.
@mrmotofy
@mrmotofy 3 күн бұрын
No actually was holding it horizontal...but yes good orientation would be the larger portion on top to shed water
Shed Electrical Installation (How to Add Electricity to a Shed - DIY)
12:16
Andrew Thron Improvements
Рет қаралды 722 М.
Do you choose Inside Out 2 or The Amazing World of Gumball? 🤔
00:19
when you have plan B 😂
00:11
Andrey Grechka
Рет қаралды 67 МЛН
إخفاء الطعام سرًا تحت الطاولة للتناول لاحقًا 😏🍽️
00:28
حرف إبداعية للمنزل في 5 دقائق
Рет қаралды 32 МЛН
БЕЛКА СЬЕЛА КОТЕНКА?#cat
00:13
Лайки Like
Рет қаралды 2,7 МЛН
The Easiest Way To Pull Large Gauge Electrical Wires Through Conduit
17:40
The details of Electrical Conduit Fittings.
0:46
Prostar-PST
Рет қаралды 1,9 М.
How to install EMT Conduit/EMT Connectors/Steel Boxes
0:40
Where PVC Conduit Cannot be installed 352.12 Uses not permitted.
4:02
Electrical Code Coach
Рет қаралды 16 М.
DIY Pulling Buriable Electrical through PVC
5:29
RMSpeltz Farm - ReefDVMs
Рет қаралды 1,1 МЛН
Invention from used 1.5V batterie that you shouldn't throw away
8:01
Inventor BLG
Рет қаралды 2,9 МЛН
How To Use Liquid Tight Conduit Connectors
4:22
ElectricianToolDeals
Рет қаралды 11 М.
How to make a simple welding machine from SPARK PLUG at home! Genius invention
15:11
Do you choose Inside Out 2 or The Amazing World of Gumball? 🤔
00:19