Here is the updated link to the bonus content: www.haascnc.com/video/Video-Bonus-Content.html Thanks for watching!
@MassoCNCAustralia6 жыл бұрын
just love everything that you guys do, HAAS defines quality in everything that they do, great work and thank you for the videos.
@sunshineautomationtooling6 жыл бұрын
I love Haas! Thank you Mark! The informational videos are fantastic! I look forward to seeing them every day.
@fitnesstrain84066 жыл бұрын
hi
@Factory4006 жыл бұрын
This is money in the bank. My favorite use is to send a '1-minute warning' code over DPRNT via TCP. Put the DPRNT about 1 minute from the end of the program for a Python script to send the operator an alarm - light flash, beep, or push to smart phone, etc. The operator then has 1 minute to settle what they are doing and arrive at the machine exactly when it is time to change the part. The manager also gets to review the operator's reaction time from M30 to cycle start. One of a million applications.....
@folkeroRGC Жыл бұрын
Any video for the old Hass controls?
@justindonajkowski3363 жыл бұрын
Mark your videos are amazing. Looking to buy own VF2 soon. Was wondering if its possible to track tooling using DPRNT? (HEAR ME OUT) I'm familiar with ATM and tool like management. But my thought was to use this DPRNT capability to track tooling in a more technical way. Say a long job (which I'm running currently) T1 expires at roughly 105 parts in the perfect world. My life value on tool life management is also set to 105. Sometimes the endmill breaks or wear(as you know) at the following example values: 103,102,98, and lastly 105 parts. Can we utilize DRPNT to capture this data and store the said numbers? That way I can look back at (103,102,98, 105) and do an average or perform further engineering analysis and tooling experiments. Let me know what you think. And if it isn't possible with DPRNT..... I have an idea for Haas for the tool life management software ;) Kind Regards JD.
@khanhdat14 жыл бұрын
Thank you for your video. I would like to ask the macro can be read the tool position and feed speed while the machine is in motion. I want to acquire the trajectory of toolpath and real feed speed of each axis. Thank you very much!
@rostislavslavov29934 жыл бұрын
Can you output which exact buttons are being pressed from the control in real time?
@MachinistNumbr75 жыл бұрын
Can all haas NGC use DPRNT, or does it require we purchase User-Definable Macro option to use?
@bradweeks56944 жыл бұрын
I am trying to DPRNT the actual spindle speed to find out if the operator has used the spindle override buttons. The problem is I am not able to capture the spindle speed. I tried #548=#3027 but #548 remains at 0.000. Any suggestions? By the way, Great videos.
@trentpope91735 жыл бұрын
Where is the link to the sample DPRNT program that he mentions in the video?
@haasautomation5 жыл бұрын
Trent - We’ve migrated our website over, and lost some links. Send us an Email to tod@haascnc.com and we can send out that Bonus Content. - Mark, Haas Tip-of-the-day
@jakemancnc6 жыл бұрын
Thanks for the video!
@jc45232 жыл бұрын
Where can i find setting 261 in a classic control ?
@robertr91386 жыл бұрын
Great information!
@hariraj58126 жыл бұрын
Please explain about different bw G65 and G66
@grunt45706 жыл бұрын
The Renishaw Inspection Plus manual link just takes me to the Haas service website. Once on the website I cant find the Inspection manual.
@haasautomation5 жыл бұрын
Send me an email at tod@haascnc.com and I can get you that information. The link was recently lost when we updated our Website. Thanks. - Mark, Haas Tip-of-the-day
@derekfriedrichs3 жыл бұрын
I don't know what it is, but this just isn't working. I set the file path to media, but nothing ever prints to it. As always, I just don't get it. I have a 2021 HAAS VF3SSYT. Used the NGC post processor, and the NGC Inspection post-processor. Any ideas why my probe cycle isn't printing anything?????
@mikstr22 Жыл бұрын
2 years later, ever figure it out? I’m having the same problem lol
@patrickmurphy2436 жыл бұрын
If I change the data collection port to 0 (or 5051) - I can longer connect via Putty (connection refused) - but if I turn the data collection port back to 5052 - I can connect but DPRNT data is not transmitted - it seems the data collection port has to match Putty to connect? any thoughts
@johnnelson86122 ай бұрын
Try two putty "instances" running on your computer. One for data collection using port 5052 and one for DPRNT using 8082
@prasaddesai91516 жыл бұрын
How to use dnc for fanuc machine , ?
@chaddanylak87065 жыл бұрын
why no I in Dprnt
@DanielMachado-816 жыл бұрын
Daniel Machado - Brazil. Custo Aqui no Brasil inviabiliza a compra das Máquinas Haas, imposto muito auto.
@haasautomation6 жыл бұрын
Daniel Machado - Unfortunately there are import regulations that Haas and Haas distributors have no control over. Thank you for supporting us and following our KZbin channel - Haas Automation
@新新朱6 жыл бұрын
an other useful video
@toymaker-te8fq4 жыл бұрын
What the hell did I just watch??? I've been a Hass user for 30 years but this new tech is so far over my head. When does the machine start making parts? :-/