Your videos are clear and easy to understand. Many many thanks. Can you please design a remote microgrid with wind-pv and diesel generator and demonstrate it? it would be a lot help. thank you.
@paramoneyo83453 жыл бұрын
i watched it and it helped me a lot for my project great explanation!
@TheUrbanScholar3 жыл бұрын
Thank you so much! Do consider subscribing to our channel.
@gastory70163 жыл бұрын
This video helps me so much. Thank you
@innovatorsinc.90574 жыл бұрын
Great video, thank you!
@saumyasingh23564 жыл бұрын
This was very well explained and extremely helpful..Thank you! Can you please upload a video regarding inverter connected to PV using MPPT simulation..thanks.
@TheUrbanScholar4 жыл бұрын
Yes we'll do it 👍 Stay tuned 😉
@saumyasingh23564 жыл бұрын
@@TheUrbanScholar Sure👍
@vasavisai18903 жыл бұрын
Please make a video on Implementing the control design from Simulink to DSP board (C2000)
@carltonncube83493 жыл бұрын
what is Vref...........and how does it change with change in duty cycle....................
@rajhandique43993 жыл бұрын
If 🔺️P>0 🔺️V>0 then duty cycle should increase
@markov4119 Жыл бұрын
I thought I was crazy when I saw this, I even went to read books about it. when dP > 0 if dV > 0 then Vref = Vold + duty cycle else Vref = Vold - duty cycle. when dP < 0 if dV > 0 then Vref = Vold - duty cycle else Vref = Vold + duty cycle. Please correct me if I'm wrong. Thank you
@erwandesfrichesdoria5717 Жыл бұрын
is it not possible to only focus on the current? The current drained can be lower or higher than the current at mpp. Then we just have to 2 if loops in which we check whether the current drained is lower or higher thant the current at mpp, and we adjust the duty cycle accoding to...
@contehalimamy48724 ай бұрын
Hello bro could you please made a video on how to do the simulation on hot spot on PV modules performaces
@arrmeilajeyanathan73183 жыл бұрын
Great video! Really helpful :) How did you determine deltaD?
@ankitnishad4082 жыл бұрын
Please correct your code in the second lop of voltage where VpV - Vprev
@chaimach89422 жыл бұрын
Which one please ghir me a answer
@jeebannayak84492 жыл бұрын
sir, at 1000 irradiation, power maintains constant but when irradiation changes to lower than 1000, power keep n deceasing. kindly reply sir.
@TheUrbanScholar2 жыл бұрын
Yes, if the irradtion decreases then the power input to the panel decreases hence the power output decreases
@Yaswanth3 жыл бұрын
At 3.47 how you taken vprev,pprev and deltaD values
@TheUrbanScholar3 жыл бұрын
Delta D depends on the perturbation yoi want.
@Yaswanth3 жыл бұрын
@@TheUrbanScholar can you share you telegram username so that I can contact you and clarify my doubts
@dheerajahlawat143 жыл бұрын
i am geting error not able to get MPPT bloick in simulk pls help as soon as possible.
@vcaa78183 жыл бұрын
Any document is available sir for using wind turbine mppt based p and O technique
@westlorndarbygirim16473 жыл бұрын
Can i simply put your code for the P&O algorithm on different PV system model ? Doest it works? Bcs i have problems to do the command
@anishaagrawal68943 жыл бұрын
Video is very helpful.I request u to make a video on incremental conductance as well. I m working on it nd get stuck in the code.Can u please help me in the code
@TheUrbanScholar3 жыл бұрын
We'll come up with the incremental conductance video soon :)
@usmanabdullah53213 жыл бұрын
kindly explain Modified P&O (dp-P&O) algorithm also
@rumman_huda2 жыл бұрын
2:04 duty cycle must increase. (I think you misread it and said decrease)
@niyantachavda13613 жыл бұрын
If I change the deltaD value to some other value (say 0.001) then duty cycle goes negative.. why so?
@TheUrbanScholar3 жыл бұрын
It should never be -ve, I suggest you to check your model again
@guywhoknows2 жыл бұрын
Is this FB tied or preset for load as I can't see priority.
@muthukumarmeiyappan0162 жыл бұрын
what will be the DeltaD value for buck converter?
@abdessalamtriche27292 жыл бұрын
can u sed to me simulink file pls
@deepakbhardwaj40189 ай бұрын
Thankyou
@lasaint183 жыл бұрын
how can I use this for a three-phase system
@surisettytejashwini46503 жыл бұрын
can you do driftfree p&o mppt
@muhammadzakir3044 жыл бұрын
Well explained! I wondered to ask if you have done simulation of P&O for series-parallel combination of PVs in MATLAB. There we sometimes have a problem of algebraic loop error while connecting PVs in series-parallel combination specially with large number of PV modules. If you could have the answer for that and make a video a on that, I hope it'll be of great help to many people.
@TheUrbanScholar4 жыл бұрын
Hey Zakir, hope you're doing well. In the previous video we show configuration of the PV panel block on simulink while doing mppt, you have to uncheck the algebraic look check box
@jaiminpatel15762 жыл бұрын
Can u send simulation of mppt video
@newDAVIDnew4 жыл бұрын
Nice. Sound could be better, your mic clips so please turn it a bit down.