Thank you so much for your precious time Sir. Can you please tell me about the solar cooling ejection system
@AbdulRehman-ce6fo3 жыл бұрын
plzz show the model energy and exergy analysis on renewalable energy system
@brijeshmistry94905 жыл бұрын
Thank you for the presentation. I've been trying to simulate Example 3 as that mentioned in Solar Energy Research Centre (SERC) and have been unable to resolve the errors. Your guidance in that direction will be much appreciated. Also I'm unable to locate project files in MyProjects folder (even after turning on the show hidden files and folders) but I can access them using the open dialogue box of TRNSYS.
@yonizoko335 Жыл бұрын
Thanks for the explication please i need TESS library for TRNSYS please can you send it to me
@harvindersharma2 жыл бұрын
Please tell me how to install this software...??
@nuhajn89648 жыл бұрын
Hello , Thanks alot for the video are there any tutorials about the input file format , i mean how to adjust the weather data in a format that the TRNSYS can load ?
@yousifabdulsamad79833 жыл бұрын
Are you now about TRNSBUILD,please
@youbtaallah7 жыл бұрын
Thank you for your good presentation, please do you have type 56 lecture
@TheodoreSeville17388 жыл бұрын
Thank you very mach for this tutorial :) I have one question, do have any idea how to integrate a solar heat water or a photo-voltaic systems to building and simulate their effect ?
@panmexili8 жыл бұрын
You mean connect the model from trnsys into a building model? If that, I am sorry, so far I don't know how to.
@naveenbhoopal33313 жыл бұрын
Bro, you links are asking for log in ID. Can you provide them?
@harisahmedqureshi20898 жыл бұрын
Sir I have demo version of TRNSYS. As I click on Run Simulation option it shows "2 errors were found in the deck.Check the listing file for more information". Could you please help me out what to do in such situation? Thankyou in advance
@AliRao917 жыл бұрын
this is because demo can only have upto 5 components, u can see your errors in the .dck file
@farhanarahman8730 Жыл бұрын
Thak You So much Sir. Very very helpful for beginners.
@chicha45908 жыл бұрын
Thanx for yhe video , just i have a request if you have an other examples ( videos or pdf or word)
@panmexili8 жыл бұрын
Not yet bro, but soon I will upload some more.
@badrshiko13618 жыл бұрын
Hello, I went to know how the PID controller works in such application
@parthkapoor36263 жыл бұрын
I'm a UG student and i need a free version of TRNSYS for my final year research project. Can somebody help me to download a free version?
@engr.abidhussainmechanical29175 ай бұрын
Dear Sir I need latest crack version of TRNSYS
@afrazmehmood74604 жыл бұрын
There is only Demo version available which is quite limited to run your own sims. Is there any free complete version available?
@alemaffo7 жыл бұрын
Great work! Thank you a lot. Wait for the next episode.
@yousifabdulsamad79833 жыл бұрын
Are you now about TRNSBUILD,please
@johnyseven87558 жыл бұрын
the consumer load profile, the equation is in liters?
@panmexili8 жыл бұрын
+johny seven If you mean how much water is flowing through the pump, it is defined in kg/hr. The Load profile (a.k.a Type 14h (a.k.a green bars component)) just tells the pump WHEN to start working,( when we have the SUN 8am -18pm) . How much water is seen in the Flow rate in the PUMP. I hope I answered! :)
@johnyseven87558 жыл бұрын
yes, Load profile is type 14h, but my question is you defined "one kg/hr " isn't very little :s ?
@panmexili8 жыл бұрын
+johny seven you're right it is very very little. Maybe I forgot to adjust it, but in the begin example it's something around 60, but not sure.
@johnyseven87558 жыл бұрын
My other question is how we regulate the system power backup eletric
@panmexili8 жыл бұрын
1. The AUX functions only the hours that the pump is running. So 8am -18pm. 2. In the input Tab of the AUX heater you will find the Tset. which is set to 60 oC (usual for Domestic Hot Water). So the AUX will work roughly until the water reaches 60 degrees. (!!! Check the mathematical Description to understand more in depth why it is set this way, and why its doesnt have all the time 60oC output Temp. !!!!!) That is a GREAT question, Thank you!
@johnyseven87558 жыл бұрын
Good afternoon, I have mistakes in my Model Thermosiphon in TRNSYS you can help ?
@panmexili8 жыл бұрын
If I can help you, of course ! tell me the issue and we will see
@johnyseven87558 жыл бұрын
How I can get information about the TYPE 109 in .xls or .csv or .m? I can not connect matlab
@AliRao917 жыл бұрын
i am facing a issue, can you please help? my system is simple solar water heater, i am using two loops, one from pump to solar collector to heat exchnager and back to pump , this loop is using oil. then i am using another loop that is using water, this is coming from load to heat exchnager then pump then aux heater. aux heater is set at 180 degree, the issue is, in my results, my aux heater is always running from 20 to 180, however, it should be running from roughly 100-180 (whatsoever is the output after the heat exchnager). meaning my heat exchanger is not exchanging any heat. can you please help. all connections seems fine
@panmexili7 жыл бұрын
have you checked all the preset temperature values and settings of the Loads and Heat exchanger (or sometimes, it could be a wrong type of component)
@kurlusosman46973 жыл бұрын
I really need it
@alejandrorocha54827 жыл бұрын
Hey, do you have other Chris Bales lectures? or can you give me the page where you found those you put ? Thanks !!
@panmexili7 жыл бұрын
HOLA, ! unfortunately no. I have taken these by my supervisor in a text file, so I also, only had the links.