PAT Testing Training and Compliance by JR PAT Testing

  Рет қаралды 21,792

JR PAT Testing Ltd

JR PAT Testing Ltd

Күн бұрын

Пікірлер: 49
@alunroberts1439
@alunroberts1439 2 жыл бұрын
On the toaster you did to do it on the correct way. You did not push the handle down to engage the internal switch. So you tested it open. Well done.
@RBcymru
@RBcymru 17 күн бұрын
You should check the earth probe lead to the socket on the PAT tester before starting.
@Hertzultra
@Hertzultra 2 жыл бұрын
I'm doing the 2377-7 in November. Really liked this and downloaded it for training... chin chin
@michaelhenry4405
@michaelhenry4405 10 ай бұрын
a microwave emissions test... I learnt something today... I have never seen anybody measure this before... It didnt even occur to me that this might be something that can fail. Brilliant video. Top class. Thanks
@afristar685
@afristar685 10 ай бұрын
Why would you need to test a microwave for emissions other than to find something to charge the customer for. It's not required in code of practice. And who tests their microwave at home?
@michaelhenry4405
@michaelhenry4405 9 ай бұрын
@@afristar685 For the same reason I check my cars tyres. nobody says I must check them. And after this video I tested my microwave. 1 minute. Either you are not from the UK or you have no idea how H&S regulations work in the the UK. You are required to ensure the equipment is of safe use.
@afristar685
@afristar685 9 ай бұрын
@@michaelhenry4405 anything you say mate
@afristar685
@afristar685 9 ай бұрын
Microwaves, in addition to radio waves and visible light, are all non-ionizing radiation. The only non-ionizing radiation that causes cancer is UV light. So overall, microwave ovens are safe to use and will not cause cancer or any other adverse health conditions
@dickymintnt700
@dickymintnt700 23 күн бұрын
Ots called good practice and is good for customers ​@@afristar685
@alunroberts1439
@alunroberts1439 2 жыл бұрын
On the coffee machine the fail is from the spur socket screw being in a plastic box the screw is not attached to a earth. You need to know you have a good earth such as using a socket tester the probe terminals.
@BaGaBwithaB
@BaGaBwithaB 3 ай бұрын
Nice work. I think I would have learned more about the devices for PAT testing if there was a clop on the menu of the PAt test tools
@dgw07
@dgw07 Жыл бұрын
First thing I would have done before testing is to inspect the cable and plug , fuse etc before plugging it straight into the tester
@ashvanbro9329
@ashvanbro9329 2 жыл бұрын
Bring out more videos I really enjoyed this mate well done
@Thomas-z9t5k
@Thomas-z9t5k Жыл бұрын
Sad case
@alunroberts1439
@alunroberts1439 2 жыл бұрын
Also on IEC leads check the amp rating of the lead such as 10Amp and check the fuse is equal to or less then.
@county582
@county582 2 жыл бұрын
Great video, would be great to see what tests you select on screen, I do this about twice a year and totally forget what I did when it comes around again 👍
@geofhillier382
@geofhillier382 7 ай бұрын
That's really interesting - I always thought PAT meant Portable - so a fixed appliance such as a cooker or a coffee machine was not part of that testing regime.
@designbydavies
@designbydavies 4 ай бұрын
Great video. Very thorough. Thanks
@Bestofthebest383
@Bestofthebest383 18 күн бұрын
8:01 I think you should switch kettle on in order to do the test
@alexhughes8895
@alexhughes8895 Жыл бұрын
Bloody good video, will help in my exams next week!
@macmerc1556
@macmerc1556 Жыл бұрын
Please be assured im not questioning your tests but having just started PAT testing i think its interesting to see other professionals (similar to yourself) doing things differently. A couple of other videos show the monitor as one test (cable and lead combined) and similarly the kettle being tested as one unit also. It seems there are areas of testing that seem to be grey! Great video thank you for posting.
@shetlandsoundlight4368
@shetlandsoundlight4368 6 ай бұрын
The 110v extension lead was a fail as the flap was missing from the female side, meaning it has no IP rating and would be not fit for purpose!
@Garry1980
@Garry1980 4 ай бұрын
The fan you tested needs turning on for the insulation test ?
@katiefinnegan4649
@katiefinnegan4649 Жыл бұрын
This was a superbly delivered instruction. Please can you tell me what tester you were using? I’m a wind turbine tech thinking of doing this as a side business.
@alunroberts1439
@alunroberts1439 2 жыл бұрын
On the 4 way did you did test each out let very good.
@stgeorgethegreat3165
@stgeorgethegreat3165 Жыл бұрын
No visual check on iec lead at beginning?
@trif55
@trif55 2 ай бұрын
did not know emissions testing was required for microwaves as part of the testing?
@BrevTech
@BrevTech 8 ай бұрын
i'm confused why you had to reach underneath to find a good earth spot on the coffee machine. There are metal panels all over it, so surely they are the biggest risk to the user and hence they should be well earthed?
@tucker35Ire
@tucker35Ire 2 жыл бұрын
Are you doing 500v test as a class 1 on the monitor or 250v.
@Sean-ws9je
@Sean-ws9je 11 ай бұрын
Am I Forced To Plug This Thing Into The Wall To Operates This Pat Testing Device ?
@monkeyvanko
@monkeyvanko Жыл бұрын
I would like to know your tricks. I have the same tester, but to get to the point of printing the test result I have to plug in the tester to the mains, get through so many steps on the machine, I m just keep typing, pressing buttons... You just plug the cable of the tested device and by pressing twice you have a result within seconds. Would by good to see the display, as somebody mentioned here
@damiandeadbeats
@damiandeadbeats 9 ай бұрын
a coffee machine is plumbed into the building water mains therefore not a portable appliance , so why test it ??
@Superfanfanatic
@Superfanfanatic Жыл бұрын
Do you have any Pat stickers I want some
@piecetoyou8285
@piecetoyou8285 Жыл бұрын
Dude great video but it was bugging me every time you said keckle lol
@davidforde1261
@davidforde1261 2 жыл бұрын
Great video. I have question regarding testing a hoover when I do the class 2 test and have the unit switched in as I do the test it doesn't power up. Am I doing test wrong. Its same tester as yours and preset is second on list
@tucker35Ire
@tucker35Ire 2 жыл бұрын
Your hoover shouldn't power up on a class 2 test. It only powers up when you do a earth touch test.
@hainman1
@hainman1 Жыл бұрын
Class 2 touch leakage test with the pat test machine plugged in is only way the appliance will start up/power up.We use same machine and on menu I think you use selection K
@alunroberts1439
@alunroberts1439 2 жыл бұрын
PAT testing so it is portable appliance test test.
@RobertMarr-u1z
@RobertMarr-u1z Жыл бұрын
Sorry to say but I'm not a fan of you demonstrating poor safe isolation procedures with the use of a volt stick which is not a approved voltage indicator nor did you have any way to check and prove that circuit was dead before you stuck your non insulated screw drives into the terminals... Safety comes first!! I think you demonstrate some other great techniques but you let yourself and others down by not following safe isolation procedures and using the appropriate tools. No one wants to see someone else get injured because they followed your video and use of a volt stick that picks up static voltage and doesn't give a true reading for a dead circuit. Please be careful in the future!
@deborahskeete-cq3zn
@deborahskeete-cq3zn Жыл бұрын
I thought the monitor was a class 2 and the monitor was a class 1.
@sw8741
@sw8741 11 ай бұрын
This must be one of those make work jobs things. "What can we do with all these unemployed people?"
@alexanderelia3905
@alexanderelia3905 9 ай бұрын
Poor video for a beginner watching! No close ups of the tester settings, no close ups of the wiring inside the socket and when performing an insulation test.
@sc1950
@sc1950 Жыл бұрын
You failed to visually assess the IEC lead, open the casing and check the fuse and connections inside it before doing the electrical test. So not a good example here, moving on..
@jamiemoffat1722
@jamiemoffat1722 Жыл бұрын
Burping at 29:10
@tamaszahorecz3177
@tamaszahorecz3177 10 ай бұрын
🇭🇺👍👍👍
@alunroberts1439
@alunroberts1439 2 жыл бұрын
When putting the cooler socket back on. Did you do a insulation resistance test in case the cable got snagged by the screw going back in. No you did not you silly boy.
@alunroberts1439
@alunroberts1439 2 жыл бұрын
On dead test did you test your tester on a proof tester no you did not you silly boy
@Thomas-z9t5k
@Thomas-z9t5k Жыл бұрын
Jobs worth
@trippyai4370
@trippyai4370 Жыл бұрын
I pushed the probe against the copper on the base of the kettle and it failed ?
Appliance Protection Classes 0, I, II, III
20:29
John Ward (jwflame)
Рет қаралды 53 М.
Мама у нас строгая
00:20
VAVAN
Рет қаралды 12 МЛН
Муж внезапно вернулся домой @Oscar_elteacher
00:43
История одного вокалиста
Рет қаралды 7 МЛН
The IMPOSSIBLE Puzzle..
00:55
Stokes Twins
Рет қаралды 193 МЛН
Why is it STILL called PAT Testing? Isn't it time to call it something else?
13:44
Earth Continuity Testing: No Experience Needed!
11:06
eFIXX
Рет қаралды 25 М.
A Buyers Guide To PAT Testers
8:47
Test Meter Group
Рет қаралды 81 М.
PAT Testing a School | Day in the life of a PAT Tester VLOG.
13:52
Caterham PAT Testing®
Рет қаралды 17 М.
Laptop Charger PAT Testing - How to do it? | Are they class 1 or 2?
8:38
Caterham PAT Testing®
Рет қаралды 25 М.
PAT Testing | Kettles
3:35
Training 1st Ltd
Рет қаралды 759
Fence Contractors Hate Me For Showing You This!
24:50
HAXMAN
Рет қаралды 3,9 МЛН
Class 2 PAT Test - is there a right or wrong way?
8:15
Caterham PAT Testing®
Рет қаралды 10 М.
Мама у нас строгая
00:20
VAVAN
Рет қаралды 12 МЛН