Heater would not turn on. Video shows and explains how to complete transformer replacement.
Пікірлер: 30
@jordanonofer3886Ай бұрын
Thanks for sharing. I'm having issues this year also. First was stack flu sensor a few weeks ago. Did that myself. It worked. Yesterday I lost power at some point during it running. Fuse was good. Still put new one in anyhow for the cost. Was gonna stop there and call repair guy. But your vid definitely showed me I can handle the transformer on my own also. Thanks for making the video. I hope it works lol. Very very good job on the video also. Thanks again
@giantessmaria Жыл бұрын
thanks my friend.... the joy of this heater is its so easy to work on.... i replaced my board and membrane pad twice already, no prob... its not cheap, but much better than paying a repairman.
@MrBrianJoseph Жыл бұрын
I’m in the pool business for years now and just wanted to say good job your video was thorough and correct
@chrisll7072 жыл бұрын
Big Thank You!!! Exactly what I needed to see
@FLYBOY123456789 Жыл бұрын
OUTDAMNSTANDING Gilbert...same problem with mine...thank you sir for an excellent video. Clean tight house...love it.
@gilbertrivera8369 Жыл бұрын
Thanks for the feedback. Happy I was able to help out and help save time, money, frustration, etc.
@jesusvalenzuela5601 Жыл бұрын
Thanks, I needed that info. Be safe.
@AquaTech225 Жыл бұрын
Mastetemp 250 an 400 an the Sta-Rite Max-E-Therm all operate the same way. I’m a service tech for pentair. All of the parts for these heaters are interchangeable and operate the same way, an the same order of operations. The only difference’s in the sizes will be gas orifice size, and if it’s natural gas or propane. Also the blower intake Orifice. So that’s 3 items but if your heater has ran before. That’s not parts you’ll ever be changing. But thermal regulator Thermistor High limit AGS sensor Water pressure switch Gas valve Motherboard/pcb Ignition module Wiring harness Fuse All of them items are going to be interchangeable.
@rbobey19 ай бұрын
Very helpful Thanks
@michaelchonos4280 Жыл бұрын
Looks like you did a great job on that Pentair master temp 400 come fix mine I’ll pay you
@zsharp17722 жыл бұрын
Thanks for the video. Question for ya… when you hold down the heater off button until it displays program settings AD1 or AD0 and SF1 or SF0 … what do those settings do?
@rickdavis22052 ай бұрын
Gilbert, can you tell me how you determined it was the transformer and not the circuit board? My Pentair master 400 has no display. I have power to the unit.
@gilbertrivera83692 ай бұрын
I wish I would have included in the video how I narrowed down my problem to the transformer. Basically you use a voltmeter to measure if current is going to the transformer and whether any current is leaving the transformer. If current is going to the transformer, but nothing measured leaving the transformer, this is usually a sure sign that the issue lies with the transformer. Hopefully this helps.
@paulabrilla55313 жыл бұрын
Hi, I have the same problem except that I see the PS LED at the back of the panel. The heater would at least try to start. It will try to fire up to call for heat and it will be OK for few seconds and then the PS LED would light up. I replaced the Pressure Switch about a month ago and it worked for the 3 times I used the heater and now, it won't even try to startup. No sound whatsoever. The Service System lights up right away together with the PS LED.
@gilbertrivera83693 жыл бұрын
Good luck. Calling Pentair tech-support was also helpful in regard to trying to troubleshoot your problem and rule out different solutions. This way you’re not chasing parts.
@StanleyASmith-im8bi3 жыл бұрын
Thanks!! Gilbert i think i have the same problem.
@gilbertrivera83693 жыл бұрын
I wish I would have included in the video how I narrowed down my problem to the transformer. Basically you use a voltmeter to measure if current is going to the transformer and whether any current is leaving the transformer. If current is going to the transformer, but nothing measured leaving the transformer, this is usually a sure sign that the issue lies with the transformer. Hopefully this helps.
@StanleyASmith-im8bi3 жыл бұрын
@@gilbertrivera8369 Cool, I will check it out Thanks!
@audio14842 жыл бұрын
Hi Gilbet great video how did you know that the transformer or that specific part was bad? Can you test the transformer?
@gilbertrivera83692 жыл бұрын
I was not able to test the transformer itself. However I concluded that the transformer was bad because I was able to read current leading to the transformer, yet no current leaving the transformer. I wish I would have included this in the video. See my comments in my reply to Stanley Smith. I go into a little bit more detail on how to test it. Hopefully this helps.
@damondelgado46032 жыл бұрын
Test for 14 volts at the memory board on the J7 connector. The first three yellow wires should read 14 volts. If your getting 240 volts(120 if wired that way) by the firemans switch and no power at the board, then its the transformer.
@eodman1112 жыл бұрын
Mine just went out. It heated for awhile and stopped dead.. the front panel is non op with the pool on and spa on buttons are lit.. I'm going start trouble shooting soon.
@damondelgado46032 жыл бұрын
Sounds like a stuck button maybe
@the.trollgubbe2642 Жыл бұрын
How did you figure out it was the transformer. I have the same unit
@gilbertrivera8369 Жыл бұрын
Pentair customer technical support, actually helped walk me through troubleshooting different components of the heater. Ultimately I determined that there was current going to the transformer but there was not any current leaving the transformer.
@freedomaugust9078 Жыл бұрын
What causes the transformer to go bad?
@gilbertrivera8369 Жыл бұрын
It could be a few different things. For me, I think it was a power surge in our area.
@freedomaugust9078 Жыл бұрын
I changed a transformer in a heater and it only lasted for a bout n hour before it went bad.
@jodycushing69962 жыл бұрын
I just had a guy come out and he didn't test anything just said it was the heat exchanger and that it would cost $800? Said nothing about a transformer or fuse. Now I wait to see if my home owners ins will cover it but I don't think he is correct.
@gilbertrivera83692 жыл бұрын
Always a good idea to get a second opinion………without sharing what the first guy claimed was the problem.