Perbaikan mindray ba-88a light signal weak

  Рет қаралды 1,570

D.I.Y (Do it Yourself)

D.I.Y (Do it Yourself)

Күн бұрын

Пікірлер: 15
@abidliboubakeur3032
@abidliboubakeur3032 5 ай бұрын
Thanks so interesting video , good job ✅️✅️✅️
@badis_dz5808
@badis_dz5808 10 ай бұрын
Thanks ❤
@d.i.yrepairnmaintenance9538
@d.i.yrepairnmaintenance9538 10 ай бұрын
You're welcome
@PhnullyEEE
@PhnullyEEE 29 күн бұрын
Do you have the installation software
@d.i.yrepairnmaintenance9538
@d.i.yrepairnmaintenance9538 29 күн бұрын
sorry my friend..i am forbidden to share it
@abubakermahdi433
@abubakermahdi433 10 ай бұрын
Thanks
@d.i.yrepairnmaintenance9538
@d.i.yrepairnmaintenance9538 10 ай бұрын
You're welcome
@shdnibagger1567
@shdnibagger1567 5 күн бұрын
Ba 88a sy ligh weak, sy cek gain rendah semua, Sy coba ikutin tutorial ganti lampu hasilnya gain nya masih rendah, gain adjust masih fail, apa yg salah ya bang
@d.i.yrepairnmaintenance9538
@d.i.yrepairnmaintenance9538 5 күн бұрын
@@shdnibagger1567 flowcell apa sudah di bersihkan ..? Atau coba gain adjustment tanpa flowcell berapa nilai yg di dapat kalau tanpa flowcell
@shdnibagger1567
@shdnibagger1567 2 күн бұрын
Belum bang, ternyata dalamnya kotor, barusan saya Bersihkan, pakai bayclean encer masih blm larut kotorannya, pakai bayclean pekat lalu air panas, baru bersih, alhamdulilah pakai lampu lama gain adjust sukses, terimakasih bang, ilmu nya sangat bermanfaat
@d.i.yrepairnmaintenance9538
@d.i.yrepairnmaintenance9538 2 күн бұрын
@@shdnibagger1567 sama² kak.
@abidliboubakeur3032
@abidliboubakeur3032 5 ай бұрын
Hi sir I need help please, i have problem with Electrolyte machine "JOKOH EX-D" It doesn't give results for Chloride though i change new electrodes. But it does show good results for Na+ and K+
@d.i.yrepairnmaintenance9538
@d.i.yrepairnmaintenance9538 5 ай бұрын
sorry my friend....i never worked on that unit... ..did the internal calibration work/did all the values ​​come out (na,k,cl)..for the internal calibration values?
@abidliboubakeur3032
@abidliboubakeur3032 5 ай бұрын
@d.i.yrepairnmaintenance9538 Yes, the internal calibration works correct for Na k cl , but when it comes to the sample, it works just for Na,K the Cl always shows this sign -------- H
@d.i.yrepairnmaintenance9538
@d.i.yrepairnmaintenance9538 5 ай бұрын
@@abidliboubakeur3032 try to runing qc ..
Mengukur nilai filter 340 dan 510 copy version (not original) mindray ba-88a v87
7:43
mindray ba-88a light signal too weak #mindrayba88a #photometermindray #photometerba88a
10:06
99.9% IMPOSSIBLE
00:24
STORROR
Рет қаралды 31 МЛН
To Brawl AND BEYOND!
00:51
Brawl Stars
Рет қаралды 17 МЛН
Mindray BA-88A Software and memory Board problem solved|Khizer Abbas|New video|solution
13:00
Khizar Abbas Business & Technical
Рет қаралды 319
Full video - Data recovery from a dead MicroSD card
16:01
DevelopAKR
Рет қаралды 499 М.
Perbaikan Photometer Mindray ba-88a v88 #mindrayba88a
11:43
D.I.Y Repair N Maintenance
Рет қаралды 236
Как устроены швейные машинки? [Veritasium]
16:50