As an engineer myself, you do the things that I wish I could do! Fantastic stuff, keep the videos coming!!
@devinwg67778 жыл бұрын
I absolutely love this guy! Must be fun to be around.
@cloroxbleach12008 жыл бұрын
I love your fire extinguisher
@sandyleask9211 жыл бұрын
"where's my fire extinguisher" takes out a water spray bottle ~ classic!
@ct6502c9 жыл бұрын
Very interesting! I'm generally more interested in high voltage experiments, but this is still very cool. One good thing with this experiment is that there isn't really much danger of electric shock since the secondary voltage would be so low (too low to overcome the resistance of the human body). The primary circuit could shock you of course, but no more dangerous than anything else plugged into the wall. The biggest dangers would be fire and wires exploding violently.
@jordangallichan24909 жыл бұрын
Hi reporting you was a mistake sorry about that
@samsimington55634 жыл бұрын
Spring: (Melts to death) AAAHHH I'M BURNING!! Wire: Uh. I'm on fire here. O_O Photon: (pretends not to notice that the wire is on fire while he explains what it's doing to the spring) Me: Smart indeed
@TheRealFrankWizza12 жыл бұрын
I like the safe manner in which you practice your craft.
@rachelvirago12 жыл бұрын
Nice transformer! Have not seen kit like that since I worked on London Underground, used as incoming for (signaling) relay rooms, although configurations varied as we ran two 100v systems (125 Hz [silver relays] and 33/3 Hz [red relays], which was the "legacy system]).
@TheManLab75 жыл бұрын
8:24 It's cool watching that tiny cable jump about the transformer due to the HUGE magnetic field 😂
@johnsanchez80292 жыл бұрын
You’ve got yourself a giant pair of stainless steel balls! So very amazing to see nature’s driving force in action. That final wire you showed sure is a beauty; and just as you said, it makes that huge transformer look small in comparison! Great stuff man. I hope all is well for you these days and I hope you have continued your studies (since this video posted) as the quest for knowledge is never ending!!! Peace, your way my friend!✌️
@JamieKugelmann12 жыл бұрын
You are nuts, man! How did you get to know all this stuff! Welcome back to KZbin again, we all love you!
@1127r10 жыл бұрын
clever man
@zx8401ztv12 жыл бұрын
Ive noticed with quite low currents the connections can really restrict the flow, soldering every strand is the only way ive found to get minimum resistance. But the wires i solder are farty in comparison to your monster cables :-) Love your vids :-)
@kontra9312 жыл бұрын
First of all, the secondary side of the transformer is not grounded at any point (though, there should be capacitive grounding). Second, the voltage is just too low to electrocute you.
@MultiHigdon10 жыл бұрын
badass dude, very cool demo,
@rachelvirago12 жыл бұрын
Interesting that you make reference to "railway cable" as a high spec cable, back in the day we always erred on the side of overengineering, "if in doubt, use a bigger cable" saved a LOT of time going back to the tables back then. Sadly this is not something that sits with today's accountancy led engineering :-( Also intersting that a "google" for "london transport signaling power supplies" turns up more articles about failures and policy documents than it does tecnical papers.
@AT_VideographyАй бұрын
Hands and nerves of steel to not even flinch at all the slag and liquid metal flying at ya. 8:09
@alexanderhayden966 жыл бұрын
i have two little girls and reading the title of the video was not the intended one 😂😂
@Sypher47412 жыл бұрын
Excellent work with all the edits and re-uploads. Just a suggestion, it might be worth sticking links to both vids mentioned at the end in the description, and/or posting them as video responses. Will save people a few clicks trying to find them once the channel gets more and more filled up. Glad to have you back, Photon.
@chriswalker79411 жыл бұрын
thats one big high current transformer. i see these at my work all day!!
@windoes98se10 жыл бұрын
how do you power this under full load do you hook it right up to the line side on the service disconnect on your house? 24,000 watts at 240 volts will pull 100 amps, no wonder your electric meteor popped
@DMAN22yeah8 жыл бұрын
he has a 100 amp supply for that transformer
@lucasforeman1698 жыл бұрын
What kind of transformer is this. I've never seen this design before.
@peterzingler62216 жыл бұрын
Industry transformer from 70-80s
@marcos225715 жыл бұрын
@@peterzingler6221 where did you get the transformer from?
@kingkongdaddy19 жыл бұрын
I need one of them for my doorbell.
@gonephishing12 жыл бұрын
I love your fire extinguisher!
@daewooparts12 жыл бұрын
i love that 400mill copper cable, i use a 8 foor piece of it for my hammer anf pop CRT's with it
@stonerlad2511 жыл бұрын
Eh we got about, 600 amps here, lets see if we can short it out. Shorts live wire with bare hand... you have balls man balls of conductive steel!
@achemachew12 жыл бұрын
That is nice. You have such wonderful toys!
@drmike09368 жыл бұрын
would this transformer work to power a railgun
@Willeexd13377 жыл бұрын
drmike 09 too low volts
@reecebeck9714 жыл бұрын
You would also have to rectify it, idk how you rectify 50,000 amps
@Dutchy196512 жыл бұрын
love the exothermic reactor inhibitor !
@kenstarr200912 жыл бұрын
Nice set for home welder! :-)
@АндрейБ-й6з6 жыл бұрын
How many kilowatts does it consume from the outlet?
@antisocialbug967110 жыл бұрын
The guy in video who is doing these kind of experiments is more fascinating then experiment. He looks very funny and joker kind of fellow. So I like to watch him when he comes in front of camera. He is really funny and joker
@precisionbones7 жыл бұрын
You're f'n inspiring. Just discovered your channel a month ago and I can't stop watching and talking about the shit you do. I recently started getting into residential wiring, your afternoons blow my mind. Do you have any videos messing around with dynamos?
@mike4ty411 жыл бұрын
So how did you manage to learn how to do this stuff right and safe? How can I, for example, learn the same?
@joelnaya53415 жыл бұрын
Dude, he is an Electrical engineer.
@CrystalAced12 жыл бұрын
I wouldnt even go near those monsters you build. But i only have one thing to say youre playing with fire.
@anonymousanonymous5327 Жыл бұрын
wow what a tidy job... that fire extinguisher hahahahahahah
@AllTheFasteners2 жыл бұрын
Lovely effort - do you know at what current does that transformer core saturates?
@DanHDMusic12 жыл бұрын
Any1 else watchin every single photonvids episode? :D
@paulmarkmoffat46386 жыл бұрын
Wow heavy shit man with some serious amps
@dylanm3612 жыл бұрын
Hey mate could you post a link to the site where you got that cable from (if you got it online)? I've been looking for ages but can't find anything besides that alibaba site..
@Dingle18212 жыл бұрын
like your fire extinguisher lol. did ya get much of an electricity bill after this?
@zx8401ztv12 жыл бұрын
Did you solder the ends on as they look untouched?
@TheHunChem11 жыл бұрын
Have a grandfather like mine, and watch photonvids :D
@ajs212010 жыл бұрын
How stupid are you people to think he is actually putting out a live electrical fire with water, seriously? The power is switched off before the fire is extinguished, no hazard whatsoever. Why waste a CO2 extinguisher when a few squirts of water do the job. If you were attempting to put out a real electrical fire with water, which is still live then yes it would be dangerous probably even lethal.
@ilikesoad10 жыл бұрын
Why do you figure putting out that particular fire with water, while live, would be dangerous or EVEN LETHAL? Is it because you once heard that water and electricity don't mix well, even though you don't have any idea how these things work, but you want to sound smart? :) Putting out fires with water is dangerous because it might arc onto you. However, in this particular case, there's no possibility of arcing, since the voltage is very VERY low. I don't see any reason why putting this particular fire, in this particular circumstance, out with water, while live, would be dangerous at all.
@HobkinBoi10 жыл бұрын
***** Yes but the metal you are welding is grounded and the welding gun arcs to the ground.
@HobkinBoi10 жыл бұрын
***** well it sure didn't seem like you knew due to your other comment
@HobkinBoi10 жыл бұрын
***** I forgot that lol. I'm kinda tired so I forget some things a little bit more easily.
@cloroxbleach12008 жыл бұрын
+ajs2120 He can literally touch the contacts. Waters resistance will lower the voltage even more.
@electricety11 жыл бұрын
HAY MATE I LOVE THAT EXTINGUISHER
@ElaBueLoRocKnRoll9 жыл бұрын
You got balls...you might be pyromaniac too...
@swapb6 жыл бұрын
please share the documentation to built such transformer .
@ElectronPower11 жыл бұрын
20kW, maybe 24kW and it ain't gonna even complain! I really like how you say this :D
@worldwidefreeride9211 жыл бұрын
I work for southern electric.. fancy a good deal on your electric bill.. looks like you need it!!
@wahidtrynaheghugh2605 жыл бұрын
What is bigger 275 or 400 mil and by how much?
@bradleyhillock75337 жыл бұрын
What is the specific name of the transformer and where could I buy one
@alexandremarus11 жыл бұрын
Has your power company ever complaint?
@jabbarhadi81438 жыл бұрын
you are crazy engineer
@DmanduckLP11 жыл бұрын
I see how its cool but I don't see how u will put it too use so could someone explain why a consumer would need something that powerful
@Llamarama10012 жыл бұрын
What was that transformer originally used for? Looks like an old isolation transformer maybe?
@1walkgirl12 жыл бұрын
Do not understand it at all but it is fun to watch :D
@Dave400012 жыл бұрын
Cheers for explaining that. Does "ground" and "Earth" refer to the same thing?
@t3hPoundcake10 жыл бұрын
I'm not the person to talk to about electrical things even though I can solder stuff here and there I have no idea about the science behind electrical systems. From my understanding of transformers, you can step up or step down, is there some law that prevents you from just wiring transformers together and turning a tiny amperage into a huge amperage? Or could you literally, given enough resources, turn 1 amp into 50,000 amps?
@abyssunderground10 жыл бұрын
The more amps you get the lower the voltage. You can still only pull the same "power" (watts) from it. Volts x Amps = Watts. If you halve volts, you double amps, or double the volts and you halve the amps.
@GratedArseCheeks10 жыл бұрын
as the other guy said, you can use a stepdown transformer to increase the amperage, 1A to 50,000A would result in the voltage being divided by 50,000:- 240v would become 5mV, and 5mV is useless for anything other than dumping loads of current through a very low resistance (as done in this video) In the real world these levels of current arent used much as the thickness of cable required goes up significantly as you use more current. Very high currents arent as useful as high voltages for transferring energy over long distances, but they are very good at generating reliable arcs and dumping heat/generating large magnetic fields, which is why very high currents are used in arc welders and mri machines :)
@XeXWill11 жыл бұрын
Was this originally a pole distribution transformer?
@BoomBoxDeluxe12 жыл бұрын
Yes, BoomBoxDeluxe does, especially this vid. "I wanna get a car suspension spring on that, and er....Definitely wanna short them out. Ba-Boom!" -PhotonicInduction. FUNNY TIMES! :-D Yep, I am, and do watch every PhotonVid that's loaded. -BoomBoxDeluxe.
@snipersquad10012 жыл бұрын
nice work
@Saelkhas12 жыл бұрын
He explained it in some video, he was just cleaning up his channel and put intros and fancy edits on his old vids.
@octoguy646 Жыл бұрын
he completely changed the meaning of electric fire😂 8:38
@noahd86739 жыл бұрын
Where did u get that transformer
@Islamic-World-Sharia-Law10 жыл бұрын
whats the input to that monster?
@215alessio10 жыл бұрын
is that a crowbar glowing like a bulb? :o
@fairyheli212 жыл бұрын
that transformer's secondaries are isolated from the ground, he is only touching one side, and it is very low voltage anyway
@CaptainCropper11 жыл бұрын
Have you considered making an induction heater? That's electric voodoo that is.
@geometricart78518 жыл бұрын
how many volts was that pulling on the bar? 3-5v?
@gowayfromme8 жыл бұрын
geometric art on another video he estimated half a volt
@KozmykJ12 жыл бұрын
Cos there's only a few volts coming off the secondary. Loads of Amps but at a low voltage.
@user-yw8sr3uj1w4 жыл бұрын
Wondering about that cable insulation.... is it that... "Asb" material
@intercity12512 жыл бұрын
Traction cable for railways on 3rd rail is at least 750v rated :P
@spongebob728511 жыл бұрын
I wish you hadn't cut the video. Did love to hear more about it. Love the channel though.
@Hells29711 жыл бұрын
I don't think this would count as a taser! More like an... incinerator? Portable crematorium? Also just fyi, Tasers shoot two electrodes... you mean stun gun.
@Michael_Michaels10 жыл бұрын
Dude you must be careful, you're dealing with DANGEROUS stuff here!!!!!
@2564651jcr12 жыл бұрын
So are these old or new videos that you're reuploading?
@TeDynef12 жыл бұрын
Yay lets play with the cable with the blank hands! :D
@MrLince-hr4of3 жыл бұрын
is this dangerous ?
@ErikEstrada9112 жыл бұрын
Can you show us a simple way to make an inverter?? 12v-220v plz!
@Smartzenegger8 жыл бұрын
Couldn't you just sneeze those flames away instead of using that sneeze flacon?
@minigunner121812 жыл бұрын
You could build a bitchin' coilgun with that coil, a PVC pipe, and a capacitor.
@johngrabil42099 жыл бұрын
you insane dude
@plzknock7612 жыл бұрын
how do you get it??
@abyssunderground12 жыл бұрын
I'd love to see what it would do to a car battery if you connected it up!
@bugoobiga12 жыл бұрын
i can smell the burning insulation from here.
@ThePucko9712 жыл бұрын
Chill out, its just metal burning! Its like any lamp you got :D
@soundseeker6312 жыл бұрын
I'm guessing you don't have a smoke alarm in that room.
@Axisoflords12 жыл бұрын
Oh god yes! He's amazing!
@clogalizator62111 жыл бұрын
Cheeeeeeeeeeeeeeeeese! Where u got this gigantic transformer and thick wire?
@EphemeralProductions11 жыл бұрын
That 185 looks like it's think enough for a 46,000 v transmission line or something! lol
@clawdeenwolf293712 жыл бұрын
Fire fire fire! ROCK ROCK ROCK!
@iAmPwny12 жыл бұрын
4 people thought he was gunna build a robot transformer
@TheEsseboy12 жыл бұрын
So 38$/meter?
@Phillll11 жыл бұрын
Dude, I like your stuff - I'm into both high currents & high voltages, and a long-time Tesla coil builder. Electronics is also my career & has been for decades & I got my first Ham Radio license when I was 14 - so electronics is my life. I'm just writing to question your maths. You refer to the transformer as 20kVA or 24kVA yet then say 60V at 'about' 250A. 60V @ 250A is 15kVA, or at 200A is 12kVA. Are they rated numbers, or measured? Just because you can draw 15kVA out of a transformer does not mean it is rated at 15kVA. In fact, if 15kVA is what you can draw into a short circuit, the transformer is definitely NOT RATED at 15kVA & will certainly not supply 15kVA all day - more like 10-12kVA. It is most likely being limited by core saturation & total losses to 'settle' at 15kVA output Max. By the way, looking at those windings, & their spacing, that transformer may be designed to run under oil, which allows a higher continuous rating by aiding heat dissipation - like 'pole transformers' - or maybe they're just for air circulation, for the same reason. What limits the power the transformer can ultimately supply is the characteristics of the core material & most notably its size - its cross-sectional area. If you told me the CSA of the core I could tell you roughly what the core is designed to be rated at. With the 35mm^2 cable you're getting around 4V (at about 1V per turn) & about 630-odd amps - a mere 2.5kVA. I'm guessing this is about a 10kVA core.
@davidclay136210 жыл бұрын
i wanna come and play with you after scool
@rachelvirago12 жыл бұрын
Old school rules! New school fails, often!
@raitokun224012 жыл бұрын
10:08 anybody could explain to me why Andy hasn't been shocked when he was holding that bar of metal ????