Mike, Very valuable information re scope setup and testing! Thank you!
@CartersDiagnostics8 ай бұрын
Absolutely 💯,. Thanks for watching!
@robertmobileman83048 ай бұрын
I don't have a automotive Pico , I use Pico 6 and Pico 7 T& M Pico T&M does not have the custom setting , But hey i try it out on a vehicle, thanks for your valuable info .........
@CartersDiagnostics8 ай бұрын
Nice. Thanks for watching.
@80SWoods8 ай бұрын
I noticed the same thing. I use Pico 7 T&M too. You can still make a custom sample rate by clicking in the Target Sampling Rate selector which opens up a new box where you can change it to 1 MS/s.
@DavyDiag8 ай бұрын
This is a great video, I don't consider myself a beginner but I've been battling with 7 sample rate, great analogues with the fishing net
@CartersDiagnostics8 ай бұрын
This is great. Glad I could clear it up a bit. This was a hurtle for me when I started 7, until I figured some stuff out. I've been using 6 for over 10 years so its been a struggle.
@TechnicianRed6 ай бұрын
Great video! So is there any time we will need a smaller sample interval? Maybe CAN bus testing, Flex-Ray, or other communication networks? Or will 1 micosecond work for most networks?
@CartersDiagnostics6 ай бұрын
For network stuff I like to use a sample rate 8 to 10 times the baud rate of the network being sampled. Example 500k baud I would use 5MS/ per second minimum. Depending on the model scope you have the time/division will be different. Practice on known good, and fine tune your setup before tackling a problem child. That is always my advise for scope users. Thank you for tuning in!
@TechnicianRed6 ай бұрын
@@CartersDiagnostics thanks I appreciate the advice!
@wzthonda80138 ай бұрын
great information thanks.
@CartersDiagnostics8 ай бұрын
👍💯
@nickayivor84328 ай бұрын
ASTUTE Carter's Diagnostics Enjoy your weekend. Thank you very much for sharing your knowledge with us Can't wait for the next video From Nick Ayivor from London England UK 🇬🇧 ⏰️ 07:12AM Good Morning 🙏 🌧 and more 🌧