Primary-Secondary Chilled Water Systems | HVAC Chilled Water Distribution System | HVAC World

  Рет қаралды 50,202

HVAC World

HVAC World

4 жыл бұрын

Hell guys!!
HVAC se related choti SE choti problem ki video ham bana KR upload krte rhte jisse apko HVAC ki knowledge milti rahe
so plz
LIKE | COMMENT | SHARE | SUBS C R I B E
Keep Sharing - And Subscribe For More Updates...
THANK YOU.

Пікірлер: 141
@HVACWorld
@HVACWorld 4 жыл бұрын
Let's have 100 likes for this video
@shahidsiddique1432
@shahidsiddique1432 4 жыл бұрын
U deserve more like
@HVACWorld
@HVACWorld 4 жыл бұрын
@@shahidsiddique1432 thanks Shahid Siddiqui
@usmankhalid1806
@usmankhalid1806 3 жыл бұрын
Sir there is more than anything you deserve
@javeedhvactechnician7760
@javeedhvactechnician7760 7 ай бұрын
kzbin.info/www/bejne/gYKomWmqbNWXedksi=gvbqOfQpDHeg804C
@abhilashac3988
@abhilashac3988 Ай бұрын
Very good👍👍
@tinkurajrajsingh8589
@tinkurajrajsingh8589 3 ай бұрын
Nice sir
@amarjeetbadhan9593
@amarjeetbadhan9593 2 жыл бұрын
Very very knowledgeable video. 🙏🙇
@mdshahbazgaddi5319
@mdshahbazgaddi5319 2 ай бұрын
Very nice explain thanks
@prakashbaby9189
@prakashbaby9189 5 ай бұрын
Nice explanation
@hvacshailendarshahganjup9464
@hvacshailendarshahganjup9464 2 ай бұрын
Good 👍
@krishnarajsaradha8653
@krishnarajsaradha8653 Жыл бұрын
Very good explain thank-you sir
@javeedhvactechnician7760
@javeedhvactechnician7760 7 ай бұрын
kzbin.info/www/bejne/gYKomWmqbNWXedksi=gvbqOfQpDHeg804C
@guddumishra5655
@guddumishra5655 2 жыл бұрын
Very good explain boss lot's thanks
@RAVIKUMAR-hd1gk
@RAVIKUMAR-hd1gk 9 ай бұрын
Bahut khub sir excellent
@HVACWorld
@HVACWorld 9 ай бұрын
Thanks
@jarugumallipavankumar7161
@jarugumallipavankumar7161 Жыл бұрын
Very good explain sir thank you.....
@muhammadjamilfaiz1173
@muhammadjamilfaiz1173 Жыл бұрын
Very nice informations.
@javeedhvactechnician7760
@javeedhvactechnician7760 7 ай бұрын
kzbin.info/www/bejne/gYKomWmqbNWXedksi=gvbqOfQpDHeg804C
@shahikhan5637
@shahikhan5637 3 жыл бұрын
Bahut achcha samjhaya aap ne
@ssraorao7565
@ssraorao7565 3 жыл бұрын
Thank you very much sir now i am got secondary pipe line and primary pipe line bypass valve (decouple)🙏
@javeedhvactechnician7760
@javeedhvactechnician7760 7 ай бұрын
kzbin.info/www/bejne/gYKomWmqbNWXedksi=gvbqOfQpDHeg804C
@alok0734
@alok0734 2 жыл бұрын
Thank you for eloborating so clear and in simple words. Appreciate your efforts, keep doing good work.
@javeedhvactechnician7760
@javeedhvactechnician7760 7 ай бұрын
kzbin.info/www/bejne/gYKomWmqbNWXedksi=gvbqOfQpDHeg804C
@kumarsong855
@kumarsong855 2 жыл бұрын
Very nice Information... your explanation way is very Good
@HVACWorld
@HVACWorld 2 жыл бұрын
Thanks
@javeedhvactechnician7760
@javeedhvactechnician7760 7 ай бұрын
kzbin.info/www/bejne/gYKomWmqbNWXedksi=gvbqOfQpDHeg804C
@skbarua7677
@skbarua7677 3 жыл бұрын
Wow...great....thanks dear
@Samshiralam
@Samshiralam 3 жыл бұрын
Sir acche se explain krte ho, main abhi kuch din pahle hi aapke chanel pe aaya hu, or mujhe acchi knowledge mili hai
@HVACWorld
@HVACWorld 3 жыл бұрын
Thanks for the feedback
@javeedhvactechnician7760
@javeedhvactechnician7760 7 ай бұрын
kzbin.info/www/bejne/gYKomWmqbNWXedksi=gvbqOfQpDHeg804C
@afrozroushan5194
@afrozroushan5194 3 жыл бұрын
Zbrdst bro ultimate appko professor hona chahye goood knowlage
@VikasSingh-sq8pk
@VikasSingh-sq8pk 3 жыл бұрын
Excellent explain sir
@A.AHAD123
@A.AHAD123 3 жыл бұрын
awesome information
@mdaafanhasan2651
@mdaafanhasan2651 4 жыл бұрын
Awsome
@sharanupujar5462
@sharanupujar5462 2 жыл бұрын
Thank u so much sir.... Really I loved it.... thanx alot
@mdmohi5635
@mdmohi5635 7 ай бұрын
Best explanation ❤
@HVACWorld
@HVACWorld 6 ай бұрын
Glad you think so!
@ASADKHAN-xb3vn
@ASADKHAN-xb3vn 3 жыл бұрын
Great Sir
@golamnur989
@golamnur989 2 жыл бұрын
I have been following your channel from quite long time. Every video is very informative. I am benefited alot from your video. My humble request make a video on 1. Chemical dosing (matual and automatic) 2. Chilled water pressurisation unit 3. Chilled water line flushing (most needed).
@javeedhvactechnician7760
@javeedhvactechnician7760 7 ай бұрын
kzbin.info/www/bejne/gYKomWmqbNWXedksi=gvbqOfQpDHeg804C
@akhtarreyaz376
@akhtarreyaz376 Жыл бұрын
Meaning content
@saimathecalligrapher
@saimathecalligrapher Жыл бұрын
Love you sir
@HVACWorld
@HVACWorld Жыл бұрын
Love you too 😘
@ankitpathade7023
@ankitpathade7023 3 жыл бұрын
Excellent explanations sir
@javeedhvactechnician7760
@javeedhvactechnician7760 7 ай бұрын
kzbin.info/www/bejne/gYKomWmqbNWXedksi=gvbqOfQpDHeg804C
@rezashahid7768
@rezashahid7768 4 жыл бұрын
Excellent sir ji
@javeedhvactechnician7760
@javeedhvactechnician7760 7 ай бұрын
kzbin.info/www/bejne/gYKomWmqbNWXedksi=gvbqOfQpDHeg804C
@singhsingh-ip1sc
@singhsingh-ip1sc 3 жыл бұрын
Nice video
@usmankhalid1806
@usmankhalid1806 3 жыл бұрын
Sir agar load 100% acheive ho geya hai or 100gpm 44 F water secondary pump k through chala geya or 100gpm 44 F decoupler line se primary motor mai a geya than ye 100gpm with 44F and return se 100gpm with 56F mill ke low delta T nahi ho jeya ga?
@sunnymodi9393
@sunnymodi9393 2 жыл бұрын
DP sensors & Temp sensors are liittle bit tricky & technical, explained well though
@javeedhvactechnician7760
@javeedhvactechnician7760 7 ай бұрын
kzbin.info/www/bejne/gYKomWmqbNWXedksi=gvbqOfQpDHeg804C
@alamroushan9351
@alamroushan9351 2 жыл бұрын
Chlir or cling tawor ka keya cantion rahta hai plz Ripley
@usmankhalid1806
@usmankhalid1806 3 жыл бұрын
And sir zaroori nahi k har floor pe aik aik Ahu hon or hum pd sensor top pe lagaty hyn but design requirment agr ahus aik floor pr 2 ya 3 bhi hotay hyn or remaining floor pr 1 ya 2 to dp sensor kahan adjust kerte hyn than how it works out?
@TAHIRHUSSAINMEPINDUSTRY
@TAHIRHUSSAINMEPINDUSTRY 3 жыл бұрын
excellent video, u said PDS will be installed at high level, why? might i will got required temperature at low level floor, 2ndly if i have industry and all AHU,s will be on one roof horizontally, where i have to install PDS?
@KashifKhan-rd8ts
@KashifKhan-rd8ts 2 жыл бұрын
Hi, I think we receive the highest pressure at the last ahu either in case of vertically placed or in horizontal placed AHUs, that's why we are installing PDS there.
@javeedhvactechnician7760
@javeedhvactechnician7760 7 ай бұрын
kzbin.info/www/bejne/gYKomWmqbNWXedksi=gvbqOfQpDHeg804C
@masterchef6694
@masterchef6694 2 жыл бұрын
Can we have 2 sets (arrays) of pumps in the secondary side? (If there are 2 different types of loads with very different pressure drops)
@javeedhvactechnician7760
@javeedhvactechnician7760 7 ай бұрын
kzbin.info/www/bejne/gYKomWmqbNWXedksi=gvbqOfQpDHeg804C
@joydipghosh3273
@joydipghosh3273 2 жыл бұрын
What is the process of calculation of de-coupler pipe size???
@KashifKhan-rd8ts
@KashifKhan-rd8ts 2 жыл бұрын
Ek size chota le kr connect kr do, part load pe chiller run karega, kabhi bhi 100% water to return lena nhi hai decoupler se.
@javeedhvactechnician7760
@javeedhvactechnician7760 7 ай бұрын
kzbin.info/www/bejne/gYKomWmqbNWXedksi=gvbqOfQpDHeg804C
@suru7593
@suru7593 Жыл бұрын
Would it be possible to create the chiller selection for various applications, such as commercial and residential, as well?
@javeedhvactechnician7760
@javeedhvactechnician7760 7 ай бұрын
kzbin.info/www/bejne/gYKomWmqbNWXedksi=gvbqOfQpDHeg804C
@ranazubairkhalid9447
@ranazubairkhalid9447 11 ай бұрын
Love you bro
@HVACWorld
@HVACWorld 11 ай бұрын
Thanks
@4umahin
@4umahin 2 жыл бұрын
Good explanation...but what will happen if in case valves of secondary pump circuit are closed and PP is still running? Like, is it possible if there may be no secondary pump?
@javeedhvactechnician7760
@javeedhvactechnician7760 7 ай бұрын
kzbin.info/www/bejne/gYKomWmqbNWXedksi=gvbqOfQpDHeg804C
@MohdJaved-oq8bn
@MohdJaved-oq8bn 3 жыл бұрын
Sir bms systems ke bare m bataiye
@thepurposeofmyexistence2511
@thepurposeofmyexistence2511 2 жыл бұрын
Dear sir, i could not get one point , why allways we put the 2way valve or picv valve on the outlet of the ahu or fcu , can we put it on inlet of fcu/ ahu , and put actuator which operate on temp sensor of return air , if room temp achived then it will close the supply valve to fcu , which is same as if we put picv down stream the fcu
@javeedhvactechnician7760
@javeedhvactechnician7760 7 ай бұрын
kzbin.info/www/bejne/gYKomWmqbNWXedksi=gvbqOfQpDHeg804C
@kashifiqbalzafar
@kashifiqbalzafar 4 жыл бұрын
Sorry sir , I missed your live session today. Excellent explanation..
@HVACWorld
@HVACWorld 4 жыл бұрын
No problem... thanks
@meesamkazmi0512
@meesamkazmi0512 3 жыл бұрын
Sir jb load km hoga decopler line mai jayega to kya secondary pupm ki frequency km hogi ya same speed pe chalega
@HVACWorld
@HVACWorld 3 жыл бұрын
Secondary pump ki frequency kam ho jayegi jisaki wjh se secondary pump ka RPM kam hoga or water flow v kam ho jayega jo energy saving ka sabse bada reason h
@meesamkazmi0512
@meesamkazmi0512 3 жыл бұрын
@@HVACWorld sir agr water flow km hoga to primary pump k liye bhi water suction km hoga kya
@HVACWorld
@HVACWorld 3 жыл бұрын
Nahi...wo decoupler line se water suck kr lega
@meesamkazmi0512
@meesamkazmi0512 3 жыл бұрын
Ok thnku sir
@usmanahmed8842
@usmanahmed8842 4 жыл бұрын
Sir first question k reply k liay thanks clear ho gya he, mera second question ye he k Ap nay jasy btya k off load pay jo return air ay gi us ka temperature b 56 rhy ga lakin jo water by pass ho raha he secondary pump say us ka temperature tu 44 hi rhy ga, is terha jb AHU ka retrurn Aur by pass ka water mily ga tu temperature 56 say km ho ker 50 nhi ho jay ga same constant volume system ki terha?
@HVACWorld
@HVACWorld 4 жыл бұрын
Video me maine explain kiya h k part load pe hmara 3 chiller me se 1 chiller off ho jayega or uske sath sath 1 primary pump v off ho jayega...jaise hi primary pump off hoga us case me bhut hi come amount me CHW bypass hoga jisse CHWR k temperature me bhut minutes difference ayega jiski wajah se baaki ke 2 chiller unload hone shuru jayege jisse k hmari power consumption come ho jayegi..ek chiz mai or add krna chahunga k primary-secondary system me secondary pump ka water flow maximum case me primary pump se zyada hota hai, kyu ke building me bhut sare equipments hote h to secondary loop me zyada GPM chahiye hota hai..isliye water bhut kam amount me bypass hota hai...
@usmanahmed8842
@usmanahmed8842 4 жыл бұрын
HVAC World thank you sir for your explanation
@johnphilip7084
@johnphilip7084 Жыл бұрын
dps which line it be placed,as there is 2 rises supply return.which floor it be placed if it is 6 floor building,
@HVACWorld
@HVACWorld Жыл бұрын
DPS has two ports, one portt will be connected to Supply line and other one will be connected with Return line to get the pressure difference between supply and return line
@usmanahmed8842
@usmanahmed8842 4 жыл бұрын
Sir Ap nay jis terha video me kaha k jb aik AHU ka 2 way valve close ho ga tu dosry AHU ka b 2 way valve close ho jay ga Aur load kam ho jay ga but mera question ye he k her aik floor ki apni cooling requirement hoti he suppose AHU #1 pay load km hota he tu lazmi tu nhi he k baki AHU ka load b km ho?
@HVACWorld
@HVACWorld 4 жыл бұрын
Mere kahne ka mtlab hai k jaise jaise floor pe temperature achieve hota jayega waise waise us AHU ka 2-way valve usi ratio me band hota jayega or jisse k ahu k accross water flow kam hota jayega or wo water Bypass line se cross ho kr primary me chala jayega....aisa ko rule nhi h k at a time sare ahu ka valve band hoga..ye understood hai k valve tab band hoga jab room ya floor ka temperature achieve hoga.....I hope ab aapko clear ho gaya hoga... comment kr ke confirm zarur krna.. thank you
@usmanahmed8842
@usmanahmed8842 4 жыл бұрын
HVAC World G thanks
@abdulraqeeb6514
@abdulraqeeb6514 Жыл бұрын
Excellent very informative , just tell me what is roll of thermoste in the room , and it is linked to return air sensor ? Please.
@abdulraqeeb6514
@abdulraqeeb6514 Жыл бұрын
May Allah bless you ,
@javeedhvactechnician7760
@javeedhvactechnician7760 7 ай бұрын
kzbin.info/www/bejne/gYKomWmqbNWXedksi=gvbqOfQpDHeg804C
@alishnawa1108
@alishnawa1108 2 жыл бұрын
Is there any English Version for ur valuable lectures ?
@javeedhvactechnician7760
@javeedhvactechnician7760 7 ай бұрын
kzbin.info/www/bejne/gYKomWmqbNWXedksi=gvbqOfQpDHeg804C
@jai.shree.Ram-sena108
@jai.shree.Ram-sena108 2 ай бұрын
Primary pumb kaha laga hota hai aur secdary pumb plz answer
@nishantsh03
@nishantsh03 3 жыл бұрын
Hot well and cold well kya hotabhai sir... Or hot well se connect kya hota hai primary pump or secondary pump
@abhijitpalai6540
@abhijitpalai6540 Жыл бұрын
Sir achutor kese manual open close karte hai ek bar bataye plz video me🙏🙏🙏
@MANISHYADAV-kc7jm
@MANISHYADAV-kc7jm 3 жыл бұрын
ye balancing valve Q lga rhe hai two way valve ke baad .iska kya opration hai
@muhammadswalih5989
@muhammadswalih5989 6 ай бұрын
Why Ur installing modulating valve at the chiller outlet, on off valve is enough
@HVACWorld
@HVACWorld 6 ай бұрын
It is on/ Off type
@hamzabadar3386
@hamzabadar3386 Жыл бұрын
Hmra jo primary pump ha wo b vfd sa control hota ha.. sir.
@HVACWorld
@HVACWorld Жыл бұрын
Secondary pump nhi hoga usme
@hamzabadar3386
@hamzabadar3386 Жыл бұрын
Dono hain sir
@mdwaquaruddin165
@mdwaquaruddin165 Жыл бұрын
In vpf system where the water goes when system is return at part load
@mohammadrahman7597
@mohammadrahman7597 2 ай бұрын
Is it possible to get a ladder diagram
@mdsuhailansari485
@mdsuhailansari485 Жыл бұрын
600 tr ka ek hi chiller ho sakta hai kya?
@HVACWorld
@HVACWorld Жыл бұрын
Zyada v ho sakta h
@RahulKumar-yy2jg
@RahulKumar-yy2jg 3 жыл бұрын
K3 metalizer kae bar me kuchh batai sir ji apana number dijiye
@chiragbari7680
@chiragbari7680 3 жыл бұрын
Need to primary and secondary pump commissioning video upload (Mumbai)
@dilawarkhan4838
@dilawarkhan4838 11 ай бұрын
Bhai to is system Mai bypass open hi rkhna hota hai
@tinkurajrajsingh8589
@tinkurajrajsingh8589 3 ай бұрын
Sir ji mujhe HVAC se koi diploma karna hai kon sa karu
@HVACWorld
@HVACWorld 3 ай бұрын
HVAC in diploma nahi hota hai.... Diploma in Refrigeration and air conditioning se hota hai
@AshrafKhan-xu4wk
@AshrafKhan-xu4wk 4 жыл бұрын
Sir apna 2 chiller 200tr iska GPM 800 hua but mera questions ye hi ki sir building ka load 50 percent hua toh vsd pump slow hua ab building ko 400gpm chahiye ye decopler line h vsd pump ke inlet and primary pump ke inlet se connect h sir ye samjh nhi aa raha h apna primary pump constent h ye depcopler se 800gpm le lega building 400gpm nhi ja payega sir depouler par automatic valve hona chahiye ki building ka 50 percent load ho toh decoupler valve se 50 percent water bypass ho
@HVACWorld
@HVACWorld 4 жыл бұрын
Good observation...jab building 50 prcnt pe operate hogi to schematic k according usko 600 GPM chahiye hoga or hamara primary pump 800 GPM delivered krega jisse decoupler se 200 GPM by pass hoga..ek point maine add nhi kiya jo mai add krna chahunga... primary-secondary system me secondary loop me zyada GPM building ko delivered krta hai maximum cases me...agar aap kisi v site pe jao waha dekhna building ka load zyada hoga to secondary pump ka flow rate primary se zyada hota hai to is case me building ko v zyada GMP chahiye hota hai kyu k bhut sare AHU hote hai..to us case me thoda paani bypass hota hai.... decoupler line pe automatic valve nahi lagate hai pani ka flow pump k pressure drop k according hota hai
@AshrafKhan-xu4wk
@AshrafKhan-xu4wk 4 жыл бұрын
@@HVACWorld sir chiller opreating kaise karte h bata dijiye step by step
@HVACWorld
@HVACWorld 4 жыл бұрын
Video mil jayegi apko....I hope apka doubt clear ho gaya hoga.... primary pump ka pura paani decoupler se suck nhi krega kyu k secondary pump v running condition me hai to wo v paani suck krega or aage building me bhejega... decoupler is chiz ko mind me rakh kr kiya jata hai uske bich ka pressure drop is trh se design kiya jata h k pura paani wapis se primary pump me na aye....
@AshrafKhan-xu4wk
@AshrafKhan-xu4wk 4 жыл бұрын
@@HVACWorld sir doubt clear ho gaya
@HVACWorld
@HVACWorld 4 жыл бұрын
Thanks
@DilshadAhmad-mw3yc
@DilshadAhmad-mw3yc 3 жыл бұрын
Sir ji vfd se load kam kyu ho raha hai Pahle 100 % me chal raha tha abhi 40% me chal raha hai kyu
@HVACWorld
@HVACWorld 3 жыл бұрын
100% kab to or 40% kab hua???
@mdsadabalam9434
@mdsadabalam9434 3 жыл бұрын
Sir DPT return ka pressure kaise sense karta hai wo to supply me laga hai
@HVACWorld
@HVACWorld 3 жыл бұрын
I will explain you in video
@mdsadabalam9434
@mdsadabalam9434 3 жыл бұрын
Thanks sir Actually,My course is about to finish on 30August,If you can explain before 30 August I will be grateful for you.Thanks
@HVACWorld
@HVACWorld 3 жыл бұрын
30 August se pahle video mil jayegi with practical demonstration
@mdsadabalam9434
@mdsadabalam9434 3 жыл бұрын
Thanks sir❤️
@usmankhalid1806
@usmankhalid1806 3 жыл бұрын
Please explain.. lot of respects Stay blessed Sir i want your email id please if you feel easy. Because your channel have made my interest in HVAC.
@javeedhvactechnician7760
@javeedhvactechnician7760 7 ай бұрын
kzbin.info/www/bejne/gYKomWmqbNWXedksi=gvbqOfQpDHeg804C
@subhashvasava6540
@subhashvasava6540 3 жыл бұрын
Humidity temperature KV Ritesh Himalaya temperature Ben 10
@johnphilip7084
@johnphilip7084 Жыл бұрын
dps be placed in which line as there is both supply and return line,for example 6floor building which floor it be placed.can i have ur mail id i have some doubt to learn can u help me out.
@HVACWorld
@HVACWorld Жыл бұрын
If 6th floor is your furthest point, Install it on 6th floor
@HVACWorld
@HVACWorld Жыл бұрын
*5th floor
@johnphilip7084
@johnphilip7084 Жыл бұрын
@@HVACWorld dps is placed in which line as there is 2 lines supply and return
@ArifKhan-nh8xd
@ArifKhan-nh8xd Жыл бұрын
Sir can you explain me how we calculate GPM
@javeedhvactechnician7760
@javeedhvactechnician7760 7 ай бұрын
kzbin.info/www/bejne/gYKomWmqbNWXedksi=gvbqOfQpDHeg804C
@DilshadAhmad-mw3yc
@DilshadAhmad-mw3yc 3 жыл бұрын
Hello sir
@HVACWorld
@HVACWorld 3 жыл бұрын
Hiii
@9889008366
@9889008366 2 жыл бұрын
Confusing.
@mepmep5682
@mepmep5682 2 жыл бұрын
100 TR ka AHU 😂
@HVACWorld
@HVACWorld 2 жыл бұрын
Isse zyada TR ka hota h
@dil_ipkumar
@dil_ipkumar 2 жыл бұрын
Bhai VFD Hota hai VSD Nahi to hai yaar correction kijiye pahle vedio ko
@trick-tech6623
@trick-tech6623 Ай бұрын
Vfd means variable frequency drive Vsd means variable speed drive. Bro plz enhance your knowledge before blaming someone.
@HVACWorld
@HVACWorld Ай бұрын
@trick-tech6623 zyada gyani ban jate ho. VFD or VSD k bare me ye video nahi h....ye Video piping system k bare me jisme pump ki speed vary karti h. Speed vary karne k liye VFD or VSD dono ka use Kiya jata h kyu dono ka kaam ek hi hai. Agar VFD k bare me janna hai to dusri video dekh lo.
@a.m347
@a.m347 Жыл бұрын
English please 😢
@usmankhalid1806
@usmankhalid1806 3 жыл бұрын
And sir zaroori nahi k har floor pe aik aik Ahu hon or hum pd sensor top pe lagaty hyn but design requirment agr ahus aik floor pr 2 ya 3 bhi hotay hyn or remaining floor pr 1 ya 2 to dp sensor kahan adjust kerte hyn than how it works out?
Heartwarming Unity at School Event #shorts
00:19
Fabiosa Stories
Рет қаралды 23 МЛН
НРАВИТСЯ ЭТОТ ФОРМАТ??
00:37
МЯТНАЯ ФАНТА
Рет қаралды 7 МЛН
Primary Secondary Chilled Water System Working | BMS Training 2021
12:20
AIR COOLED CHILLERS & WATER COOLED CHILLER - HVAC DESIGNING CLASS 14
56:03
SM Techno MEP Training Services
Рет қаралды 28 М.
District Cooling System - Walkthrough
30:38
Fazil Omer
Рет қаралды 35 М.
Trane Engineers Newsletter LIVE: Chilled Water System Design Trends
1:29:06
Trane Commercial Education and Training
Рет қаралды 13 М.
Primary Secondary Pumping - Chilled Water Example
15:35
JMP Equipment Company
Рет қаралды 101 М.
#259 Primary & Secondary Pump System in Chiller
11:32
Girish Shinde
Рет қаралды 35 М.