Primary Secondary Pumping

  Рет қаралды 48,655

JMP Equipment Company

JMP Equipment Company

Күн бұрын

Пікірлер: 11
@kannathasank9629
@kannathasank9629 2 жыл бұрын
Thanks a lot for your lovely lesson, I have been learned about primary & secondary pumping in a chilled water system.
@ismscsim
@ismscsim 4 ай бұрын
Amazing lesson ....thank you
@charlesananayo4461
@charlesananayo4461 7 жыл бұрын
Great Seminar I learn lot of things about your topics thank you more power for you
@Ali_Alhamaly
@Ali_Alhamaly 5 жыл бұрын
Nice discussion about wasted energy due to low return water temperature @51:40 also explaining chiller loading as a function of return water temperature for a given setpoint supply temperature is very good and illusturative
@michelleheart190
@michelleheart190 Жыл бұрын
Thank you!
@hueman7
@hueman7 9 жыл бұрын
great lesson , very informative,
@tk032009
@tk032009 9 жыл бұрын
Great seminar - Very informative
@sunshine7453
@sunshine7453 7 жыл бұрын
Then why bother with the common pipe? Take it out and take out the secondary pump, the system is always balanced?
@TW-mp8zx
@TW-mp8zx 6 жыл бұрын
Sun Shine I know it’s been a year since you post this but I think I might know the reason. This layout is usually used when you are coupling 2 or more heat or cooling sources to a system and it’s meant to promote optimum efficiency The primary loop is separate to the secondary loop and is designed for the primary flow rate to meet the secondary flow rate with the correct temperature demand on the flow in order to achieve a perfect return temperature so that the boiler flue temperature will condensate all while the boilers firming at half rate. The primary loop being utilised as a low temperature loss header that keeps the boiler operating efficiently. Hope that explains that
@MdImran-uu8uv
@MdImran-uu8uv 4 жыл бұрын
To main a minimum flow rate of chillers i.e in primary circuit ,what ever may be the demand in secondary flow ,assume the demand of secondary flow is much lesser than minimum flow of chiller ,but chiller has to work atleast at minimum flow rate ,so excess water will go into common pipe.and other reason is that to operate the two circuit differently
@mikaelbasha1992
@mikaelbasha1992 4 жыл бұрын
thank a lot
Primary Secondary Pumping - Chilled Water Example
15:35
JMP Equipment Company
Рет қаралды 102 М.
Hydronic Balance - Part 1
55:23
JMP Equipment Company
Рет қаралды 16 М.
Когда отец одевает ребёнка @JaySharon
00:16
История одного вокалиста
Рет қаралды 15 МЛН
1 сквиш тебе или 2 другому? 😌 #шортс #виола
00:36
兔子姐姐最终逃走了吗?#小丑#兔子警官#家庭
00:58
小蚂蚁和小宇宙
Рет қаралды 10 МЛН
小蚂蚁会选到什么呢!#火影忍者 #佐助 #家庭
00:47
火影忍者一家
Рет қаралды 121 МЛН
Condensing Boiler Piping Design
42:54
JMP Equipment Company
Рет қаралды 27 М.
Modern Pump Selection for System Efficiency
1:03:18
JMP Equipment Company
Рет қаралды 3 М.
Essential Chiller Terminology HVAC delta t
19:56
The Engineering Mindset
Рет қаралды 293 М.
Hydronic Balance - Part 2
1:02:54
JMP Equipment Company
Рет қаралды 7 М.
A4 / V2 Rocket in detail: Turbopump
1:51:13
Astronomy and Nature TV
Рет қаралды 1,6 МЛН
The World at War (Ralph Raico) - Libertarianism.org
3:06:00
Libertarianism.org
Рет қаралды 317 М.
CompTIA Network+ Certification Video Course
3:46:51
PowerCert Animated Videos
Рет қаралды 7 МЛН
Когда отец одевает ребёнка @JaySharon
00:16
История одного вокалиста
Рет қаралды 15 МЛН