#probelem #travelem #electricaleducationallibrary ProbeDD Jobs: Bow Thruster Unable to Start While Leaving Floating Dock #educationalvideo #problem #bowthruster #drydock
Пікірлер: 8
@tonelu24611 ай бұрын
Nice!
@mikeadler4348 ай бұрын
👍👍
@aleksandrlogin...739 Жыл бұрын
Goodjob in faultfing. So, the reason was like a faulty signal from PMS didnt allow the BT to start. Can you explain, was it a problem with some relay contacts or PLC output signal on MSB side?
@ProbeLem Жыл бұрын
There was an IAS retrofit during this DD and the retrofit service engineer was not yet finished with the PMS programming so we have to override bow thruster’s logic interface with PMS.
@aleksandrlogin...739 Жыл бұрын
@@ProbeLem Got it!
@leonemaeregio6231 Жыл бұрын
😮😮😮
@niky71974 ай бұрын
Please inform to keep away from BOW THRUSTER in dock yard worker before testing, starting... 🚫🚫🚫🚫
@ProbeLem3 ай бұрын
Yes, all yard crew were cleared already since we are about to leave the floating dock.