PROOF STRENGTH - Factors of Safety for Tension Joints with Preload in 13 Minutes!

  Рет қаралды 13,062

Less Boring Lectures

Less Boring Lectures

Күн бұрын

Пікірлер
@kevins1552
@kevins1552 4 жыл бұрын
This is gold. Absolute gold.
@ahilankalirajah7298
@ahilankalirajah7298 2 жыл бұрын
Your honestly amazing! I work as a junior plant engineer and I always use your videos to double check the work that I am doing or whenever I get stuck. Honestly god bless and never stop making the videos which you do because I honestly use them as a refresher. 💯
@eyoelzenebe3810
@eyoelzenebe3810 3 жыл бұрын
I have never seen such a clear lecture . thanks a lot
@mohammadesmaeilzadeh8240
@mohammadesmaeilzadeh8240 2 жыл бұрын
Could you please check the value of Sp as used in the calculations? (Table 8-9 of Shigley's textbook: Sp = 85 Kpsi). Am I right? Please also check the final value of Km. Thanks for the video.
@IcanCwhatUsay
@IcanCwhatUsay Жыл бұрын
I concur. The value should be 85kpsi. Shigley's example on pg 442 Example 8-4 also agrees (see answer #3 on pg443)
@enestlv01
@enestlv01 9 ай бұрын
yes bro I noticed that too. thanks for your comment. I thought I am the only one who think like that.
@shoefighter
@shoefighter 3 жыл бұрын
Great lessons can you help with a specific problem?
@LessBoringLectures
@LessBoringLectures 3 жыл бұрын
Sure. Might be hard through text, but we can try.
@shoefighter
@shoefighter 3 жыл бұрын
@@LessBoringLectures is there anyway i can send you pictures ?
@shoefighter
@shoefighter 3 жыл бұрын
or a way that we can corrispond instantly ?
@axeld9108
@axeld9108 3 жыл бұрын
Thank you very much once again, really helpful. Just one question, if the bolts weren't meant to be reused, the safety factors would've been less than 1?
@LessBoringLectures
@LessBoringLectures 3 жыл бұрын
Not necessarily. If they're not meant to be reused, it only means that the preload, Fi, can be higher; which means that all the calculations (for allowable external loads, for example) need to be carried out again with that new Fi value. The safety factor should always be greater than 1 for the design not to fail.
@APAPictures
@APAPictures 3 жыл бұрын
If this calculation done reverse, isn't that more easier? Like Based on gut filling, assume 4 number of bolt n find out external force in bolt. Then based on bolt stiffness n joint stiffness calculate fos. If its slightly less than 2 then increase number of bolt or size of bolt. Isn't this another approach?
@BipinKumar-oo7qc
@BipinKumar-oo7qc 2 жыл бұрын
Correction: Yielding Factor of safety shall by Yield strength /bolt stress not Proof strength/bolt stress.
@jaspergoodall6902
@jaspergoodall6902 2 жыл бұрын
nice
Springs Fatigue and ZIMMERLI Analysis in Just Over 10 Minutes!
11:44
Less Boring Lectures
Рет қаралды 7 М.
The Incredible Strength of Bolted Joints
17:58
The Efficient Engineer
Рет қаралды 3,3 МЛН
黑天使只对C罗有感觉#short #angel #clown
00:39
Super Beauty team
Рет қаралды 34 МЛН
小丑教训坏蛋 #小丑 #天使 #shorts
00:49
好人小丑
Рет қаралды 39 МЛН
We Attempted The Impossible 😱
00:54
Topper Guild
Рет қаралды 51 МЛН
Bolt (Fasteners) and MEMBER STIFFNESS in Just Over 10 Minutes!
11:07
Less Boring Lectures
Рет қаралды 27 М.
LEWIS BENDING STRESS at the Teeth of a Gear in Just Over 12 Minutes!
12:32
Less Boring Lectures
Рет қаралды 21 М.
Power Screws - Torque to Force Relationships in Just Over 10 Minutes!
10:41
Less Boring Lectures
Рет қаралды 101 М.
BOLT TENSION and Tension at Non-Permanent Joints in Just Over 10 MINUTES!
11:29
Mechanical SPRING DESIGN Strategy and Restrictions in Under 15 Minutes!
14:28
Does Rebar Rust?
7:49
Practical Engineering
Рет қаралды 4,6 МЛН
Fatigue FAILURE CRITERIA in Just Over 10 Minutes!
11:35
Less Boring Lectures
Рет қаралды 76 М.
Understanding Failure Theories (Tresca, von Mises etc...)
16:18
The Efficient Engineer
Рет қаралды 2,2 МЛН
黑天使只对C罗有感觉#short #angel #clown
00:39
Super Beauty team
Рет қаралды 34 МЛН