No video

PSC Girder stressing calculations method before Stressing the prestressed concrete Girder.

  Рет қаралды 34,433

Speee

Speee

Күн бұрын

Best process of PSC Girder Stressing--
Prestressed concrete girders are the leading choice for bridge construction across the country, and it's easy to understand why. Compared to other materials and bridge superstructures, studies show prestressed I-beam girders have the longest service life and require less maintenance.
It is published by the Bureau of Indian Standards. Some provisions of Code IS: 456 - 2000 entitled Code of Practice for Structural Concrete are also applicable to Pre-stressed Concrete. KEYWORDS: PSC T-Beam, IRC: 1343-2012, IRC: 5-1998, IRC: 6-2000, IRC: 18-2000, IRC: 21-2000, IS: 6006-1980.
The function of post-tensioning is to place the concrete structure under compression in regions where load causes tensile stress. ... Sheathing or ducting houses the prestressing steel This allows it to move as necessary when the tensioning force is applied after the concrete.
four types
There are four types of girder bridges, classified depending on the construction material and type of girders used. A rolled steel girder bridge is built using I-beams made from prefabricated steel, while a plate girder bridge is constructed by welding flat pieces of steel together on-site to make the I-beams.
Advantages & Applications of Post-Tensioning
It reduces or eliminates shrinkage cracking-therefore no joints, or fewer joints, are needed.
Cracks that do form are held tightly together.
It allows slabs and other structural members to be thinner.
It allows us to build slabs on expansive or soft soils.
IS: 455 - specifications for PSC (Portland slag cement). IS: 1489 - specifications for PPC (Portland pozzolana cement). IS: 6909 - specifications for SSC (super-sulphated cement).

Пікірлер: 49
@swatiisrivastava8121
@swatiisrivastava8121 Жыл бұрын
Ordinates nikalne ke tareeka to bataya hi ni wo to main hai plz uspe koi video bnaiye
@SunilMaurya-pq2rw
@SunilMaurya-pq2rw 3 жыл бұрын
Sir aap bhut achi trah stressing ke bare me btaye thq sir
@tewatiainaustralia
@tewatiainaustralia Жыл бұрын
Good Work...very informative and thorough technical
@sptewatia
@sptewatia Жыл бұрын
Thankyou bhai ji
@nileshyewale2327
@nileshyewale2327 5 ай бұрын
Sirji apka information bahut achaa hai . Lekin is calculation modified pressure nikalne ke liye divided me 9.81 karna padta hai jisse hum KN to Kg converted hota hai kyu ki humko pressure ka unit KG/cm^2 hota hai na sir
@SunilMaurya-pq2rw
@SunilMaurya-pq2rw 3 жыл бұрын
Good sir ji 🙏
@RamSingh-zr8lw
@RamSingh-zr8lw Жыл бұрын
Thanks a lot
@Abhiyadav56114
@Abhiyadav56114 9 ай бұрын
Good video
@shikhargupta6646
@shikhargupta6646 9 ай бұрын
Waah bhai
@AnilKumar-gr9qi
@AnilKumar-gr9qi 3 жыл бұрын
Very good Sir
@ajeetmakedesigner59
@ajeetmakedesigner59 2 жыл бұрын
Grouting k callculation k video bnao sir plz
@shababimran
@shababimran 2 жыл бұрын
Slip kya hota hi.. please explain
@venkatmuni4774
@venkatmuni4774 Жыл бұрын
At what pressure, the girders will fail? If the girders fail, what will be the instant reaction??
@rajeshnema5062
@rajeshnema5062 Жыл бұрын
Zero correction is taken from which code?
@durgeshsen9516
@durgeshsen9516 2 жыл бұрын
can i get that drwaing which one yo used in this video?
@ravindrakumar9514
@ravindrakumar9514 9 ай бұрын
Grip length kya hora hai?
@vishwaspatel-qz5uh
@vishwaspatel-qz5uh 11 ай бұрын
Isme locking pressure kitna de na hota he?
@sumanmazumder3112
@sumanmazumder3112 Жыл бұрын
Jacking force ton pe hey.....kaisey kg/cm2 leke Gaya?
@sumanmazumder3112
@sumanmazumder3112 Жыл бұрын
266.980
@soumitrasamanta4114
@soumitrasamanta4114 3 жыл бұрын
🙏
@ultimatewarrior3829
@ultimatewarrior3829 Жыл бұрын
Brother iss me cable dia kya hota hai
@user-arusunnyvlogs
@user-arusunnyvlogs 10 ай бұрын
Sir what is zero correction.??
@samrjeetkumar5208
@samrjeetkumar5208 2 ай бұрын
Trening cantar kaha hai
@adityanagavenkata349
@adityanagavenkata349 8 ай бұрын
how to calculate the locking load
@nileshyewale2327
@nileshyewale2327 5 ай бұрын
75% of total load
@mscivilconstruction2338
@mscivilconstruction2338 2 жыл бұрын
1000 - 650 kaha se ayaya
@shubhamrana2027
@shubhamrana2027 Жыл бұрын
Sir strand wire ka unit weight kaise nikalte hai
@sptewatia
@sptewatia Жыл бұрын
in next video
@shubhamrana2027
@shubhamrana2027 Жыл бұрын
@@sptewatia okay sir
@Vandy_fam
@Vandy_fam 3 жыл бұрын
💯💯❤❤
@animeshdas6077
@animeshdas6077 2 жыл бұрын
Please give me next video
@animeshdas6077
@animeshdas6077 2 жыл бұрын
Is it applicable for post tension girder
@sptewatia
@sptewatia Жыл бұрын
yeah
@narendrachoudhary9555
@narendrachoudhary9555 2 жыл бұрын
Sir iska next video kha h
@anjalitewatia2016
@anjalitewatia2016 3 жыл бұрын
👍🏻
@lalittomar5204
@lalittomar5204 2 жыл бұрын
your next video?
@MohitKumar-bz2cz
@MohitKumar-bz2cz 2 жыл бұрын
Sir pre/mtr hoging kitne aati h
@sptewatia
@sptewatia 2 жыл бұрын
1 mm per metre
@AbhishekShukla-yg2fq
@AbhishekShukla-yg2fq 2 жыл бұрын
No audio
@tarunce995
@tarunce995 Жыл бұрын
GR ki drw. H ye
@niteshbilaspur
@niteshbilaspur 3 жыл бұрын
Sir plz provide drawing
@rohitdtg
@rohitdtg 3 жыл бұрын
Reading wala video
@aNdYbisHtG
@aNdYbisHtG 3 жыл бұрын
Sir how we calculate jack ram area at site??
@vijay12358
@vijay12358 2 жыл бұрын
U will get it from the jack manual or it will printed on jack. . U cannot calculate jack ram area at site. U have to open the jack piston to find out
@tarunce995
@tarunce995 Жыл бұрын
Units toh use ki hi nhi h ....results ki
@ajaythakur8808
@ajaythakur8808 2 жыл бұрын
Sir yhe drawing link m daal do
@swatiisrivastava8121
@swatiisrivastava8121 Жыл бұрын
MORTH TABLE me hai
@manojchauhan180
@manojchauhan180 2 жыл бұрын
Method aapka sahi ho sakta hai but Calculation galat hai aap mm ko meter se divide kr rahe ho aur m ko mm se multiply kr mm likh rahe ho !!!!
Cable Profiling in PSC Girder | Process of Cable Profiling
32:02
WHO CAN RUN FASTER?
00:23
Zhong
Рет қаралды 42 МЛН
The Joker saves Harley Quinn from drowning!#joker  #shorts
00:34
Untitled Joker
Рет қаралды 66 МЛН
ОБЯЗАТЕЛЬНО СОВЕРШАЙТЕ ДОБРО!❤❤❤
00:45
WORLD'S SHORTEST WOMAN
00:58
Stokes Twins
Рет қаралды 193 МЛН
The actual reason for using stirrups explained
9:01
The Engineering Hub
Рет қаралды 778 М.
Post Tensioning and Grouting full stepwise video
10:02
Ambarish Bhope
Рет қаралды 289 М.
Open Beams Have a Serious Weakness
11:02
The Engineering Hub
Рет қаралды 864 М.
Post Tensioning of PSC Girder | PSC Girder Stressing in Hindi
56:17
WHO CAN RUN FASTER?
00:23
Zhong
Рет қаралды 42 МЛН