Purpose of Start-Up Vent in Boiler | Why Start-Up Vent provided in Boiler? |

  Рет қаралды 15,998

Power Plant Discussion

Power Plant Discussion

Күн бұрын

Hello friends,
"Power plant discussion" welcome to all of you my friend to this channel, my name is chandan pathak, I have 10 years of experience in power plant operation field I have created this channel only for sharing knowledge about power plant operation and maintenance, for this I shall provide series of lecture on the various topic of power plant in which theoretical, practical and mathematical concepts are included.
Email
powerplantdiscussion@gmail.com
Website
/ @powerplantdiscussion (Company Website)
LinkedIn
/ power-plant-discussion...
#powerplantdiscussion
#startupvent
Thanks to all of you for connecting me.

Пікірлер: 28
@manjittiwari8042
@manjittiwari8042 Жыл бұрын
Very good bhai
@GunMasterX007
@GunMasterX007 Жыл бұрын
Sir I'm DCS Engineer i observed in Inceration type horizontal boiler (coal + spent wash)15 toh 44 kg/cm² , 400⁰c when I open vent temperature of steam reduces although Bagas fired Boiler when I open start up vent temperature increases. Why it was happen?
@vireshtamadaddi7521
@vireshtamadaddi7521 Жыл бұрын
I am also DCS Engineer I have 3yrs experience travelling boiler or AFBC boiler
@SONUKUMAR-yc9bg
@SONUKUMAR-yc9bg Жыл бұрын
Sir please make video on Turbine Roll check,Bump check,swing check,Horn drop test
@chandanjana6964
@chandanjana6964 Жыл бұрын
❤❤
@Lucky-fb5ln
@Lucky-fb5ln Жыл бұрын
The temperature of condensate will never increase than the temperature of the flue gas so if the temperature of condensate is detrimental to tube material then temperature of flue gas must be detrimental for the same. Then how that thing manage??
@ilyasa92
@ilyasa92 24 күн бұрын
Turbine governors rpm speed control failure and rpm variation hunting
@sushantbhosale9934
@sushantbhosale9934 Жыл бұрын
Sir, thermal properties ke relation ka ek video banao jaise ki area badhne se kya hoga, pressure temperature ka kya effect padega
@MYOPINION05
@MYOPINION05 Жыл бұрын
Sir why boiler refectory is essential in boiler operation..is topic me 1video baniye.
@PowerPlantDiscussion
@PowerPlantDiscussion Жыл бұрын
Sure
@yppal9151
@yppal9151 3 ай бұрын
Sir thermax combipack husk fire boiler ka light up a to z bataye jut VA col se
@yogeshnath9982
@yogeshnath9982 Жыл бұрын
Please make one video, why does boiler bank zone connect with down comer line. Actually I am little bit confused so please make a one separate video.
@shahpratik4677
@shahpratik4677 Жыл бұрын
Sir , pls make video on how to design coal dryer...?
@AnshuKumar-es1lg
@AnshuKumar-es1lg Жыл бұрын
𝓥𝓮𝓻𝔂 𝓿𝓮𝓻𝔂 𝓰𝓸𝓸𝓭 𝓼𝓲𝓻
@raviprasad2228
@raviprasad2228 Жыл бұрын
Please make video on boiler tube materials
@cck1496
@cck1496 Жыл бұрын
Good video.... What about trapped air between MSSV and Steam turbine? Thanks.
@RohitKumar-se7db
@RohitKumar-se7db Жыл бұрын
hello sir i have serious query that i want to ask that my father is doing business of related to services of cooling tower and all its spare parts and set of of cooling tower i want to join my father business but i have some basics knowledge about cooling tower, i am thinking that before go to the business which course should i opt related to knowledge of cooling tower, i have done my graduation bcom programme so i need your help and suggestion about it and i also want to know that what education and qualification you have done
@shaquibofficial4835
@shaquibofficial4835 Жыл бұрын
Sir ppm aur loto pr ek video baniye n
@ankitkumar-pf9tv
@ankitkumar-pf9tv 10 ай бұрын
Sir DCS SE KAISE OPERATE KARTE HAIN ,BOILER KA DCS VIDEO BANAIYE SIR PLEASE
@GalaxY2.000
@GalaxY2.000 Жыл бұрын
Sir FGD pr ek video bnayiye
@Shiv4mv10
@Shiv4mv10 Жыл бұрын
You should've included function of various vents too
@amitdowary3771
@amitdowary3771 11 ай бұрын
Dada tumar number ta paw jaba 😢
@MsAaee
@MsAaee 4 ай бұрын
Why not in English
@ghanshyamrajbhar6901
@ghanshyamrajbhar6901 2 ай бұрын
Jo word english me bolte hai Thora repit kar dete hindi me
@govindbiswash8898
@govindbiswash8898 Жыл бұрын
Ak chhti si baat lamba banate ho
@dkyadav9962
@dkyadav9962 Жыл бұрын
Tum bahut udate ho chandan ..normal phle btao fer uska bistar dusare vedio me dalo ....u manger ho kya reliance ke
@PowerPlantDiscussion
@PowerPlantDiscussion Жыл бұрын
Kya improvement krna chahiye jisse aur ache se explain kr saku
@seeker2009
@seeker2009 2 ай бұрын
Bhai you need to more study before making video
In which condition Vacuum breaker Valve Open?
3:54
Power plant with Ankit
Рет қаралды 656
DM Plant Part 3 I DE-mineral Water I Soft water I Blind Water
25:31
Power Plant Tech Knowledge
Рет қаралды 22 М.
What is Ash? | Types of Ash | Bottom Ash | Fly Ash | Ash in thermal power plant |
8:52
TDBFP | Working and Principle of TDBFP | Turbo Driven BFP | TDBFP in Power Plant |
18:58