Quality Control Series : Running controls

  Рет қаралды 9,092

arunharith

arunharith

Күн бұрын

Пікірлер: 35
@the-official9521
@the-official9521 6 ай бұрын
Your videos are very helpful for me, sir. Your explanation is excellent. I had many doubts related to quality control and other lab statistics, but now all doubts are clear. It will be a fortune to work under your supervision.
@gulwalikhan2326
@gulwalikhan2326 2 жыл бұрын
thanx i like your all lectures love from pak khyber pukhtoon khwa
@shilpanagar9061
@shilpanagar9061 2 жыл бұрын
I am from Uk, working as biomedical scientist. Specially nowadays very hot in the Uk so QC giving very hard time. Temperature also affect QC results. When I have duty on analyzer it’s very important while doing maintenance as well beofre post cal and QC. We have Roche cobas 8000 c701 and e801. Also I worked p612,P617. 601. To be honest I loved to watch ur video sir. It’s really interesting
@arunharith
@arunharith 2 жыл бұрын
Thanks
@geethasruthi5780
@geethasruthi5780 2 жыл бұрын
Thank you sir for starting this series.
@medicaleducation8978
@medicaleducation8978 Жыл бұрын
Crystal clear amazing lecture ☺️
@Captainlab01
@Captainlab01 2 жыл бұрын
Lots of thanks sir to start this series
@Rajesh_Jambhulkar
@Rajesh_Jambhulkar Жыл бұрын
Great content, must watch👌
@monitsundriyal575
@monitsundriyal575 2 жыл бұрын
Sir your lecture are awesome keep uploading your videos
@realmutsuddi9314
@realmutsuddi9314 2 жыл бұрын
Nice lecture sir. #Bangladesh
@hariskhan-pd3qf
@hariskhan-pd3qf 2 жыл бұрын
Great Great Great. 👍🏻 Really informative lectures. Sir i request you that kindly start a certificate courses of Medical laboratory Quality control / Quality management. Thank you sir. Regards Haris Qurashi From Pakistan 🇵🇰.
@saviourlives25
@saviourlives25 2 жыл бұрын
Thank you very much for nice lecture sir 🙏🏽
@OmPrakash-yj9ek
@OmPrakash-yj9ek 2 жыл бұрын
Jai Hind sir, thanks a lot for your valuable knowledge.
@rishikeshpandey3967
@rishikeshpandey3967 2 жыл бұрын
Thanku sir I am Rishikesh pandey from biochemistry technician from Medanta Lucknow
@arunharith
@arunharith 2 жыл бұрын
Hi. Welcome
@MLT5821
@MLT5821 Жыл бұрын
Sir, you made a complete video of Microlub 300
@Sukhmanjitsinghkhattra
@Sukhmanjitsinghkhattra 2 жыл бұрын
Awesome sir 🙏 please also share nabl daily and monthly procesing in lab record maintain and document for lab manager
@abhiishekkpal6504
@abhiishekkpal6504 2 жыл бұрын
Sir semi biochemistry ke graph pe bhi ek video bna dooo
@sourabhranjan2721
@sourabhranjan2721 2 жыл бұрын
Waiting for next lecture 🙏🏻
@happyhunjan8904
@happyhunjan8904 2 жыл бұрын
Sir , Plz make video on seven quality tools 🙏🙏🙏
@sourabhranjan2721
@sourabhranjan2721 2 жыл бұрын
Thank you so much sir 🙏🏻💖
@DharmendraKumar-jt7ir
@DharmendraKumar-jt7ir 2 жыл бұрын
Thanks Sir
@vinayakbadiger2632
@vinayakbadiger2632 2 жыл бұрын
Thank you sir
@drrajjutiwari9267
@drrajjutiwari9267 8 ай бұрын
Sir please make a vedio on quality controll of CLIA, wheather both or all 3 level of qc need to pass to run the sample or we acan run the sample ifbonly one level qc is pass
@nirmalnvl
@nirmalnvl Жыл бұрын
Thankyou soo much 🙏
@jsjohn
@jsjohn 2 жыл бұрын
When will English version come?
@alknishak5241
@alknishak5241 2 жыл бұрын
Thanks
@sayanichaudhuri5495
@sayanichaudhuri5495 2 жыл бұрын
Sir Thank you so much for sharing knowledge. Sir I have a few queries - 1. Should Westgard rule 1(2s) be followed for same day run also? Eg In the morning qc run, I got 1 2s and same in evening run also, then will it be 2 (2s) or can we rectify it the next day? 2. When control goes bad and QC out, then do we have to calibrate (when reagent is not changed) before running fresh controls? 3. Do we have to calibrate before running controls, if same lot reagent is used in case reagent goes bad? 4. Westgard rule 4(1s) to be followed day wise or run wise?
@arunharith
@arunharith 2 жыл бұрын
The rules are applied to every continuous run. Also if you are running 3evel control and 2 values are above 2s then also it is considered as 2s violation. So every consecutive run or even across the same run
@sayanichaudhuri5495
@sayanichaudhuri5495 2 жыл бұрын
@@arunharith Thank you Sir
@the-official9521
@the-official9521 5 ай бұрын
Sir R4s is a random error or a systematic error ,the R4s is a rejection rule right?
@RanjeetKumar-jd9bc
@RanjeetKumar-jd9bc 2 жыл бұрын
Hello sir Thank you for valuable lecture Sir suppose i released critical result and dr took action on that result In that case when i get to know my qc is out so how will modify the result
@arunharith
@arunharith 2 жыл бұрын
Partner. Run qc. If result fine then release reports. When qc fails. Stop testing. Correct reason for qc failure. Run qc to be sure system is fine. Do walk back studies to see if any patient result was impacted. If no well evey thing is fine. If yes call back the report. Release modified report. Inform pt and doctor. No way out. Hiding facts could create more problems. Walk back and modified report is a well accepted thing. ONLY ONE THING. THE LAST QC RESULT BEFORE THE SAMPLE WAS RUN SHOULD BE FINE. IF THERE WAS A QC OUTLIER AND U HAD NOT REACTED TO IT, THAT WOULD AMOUNT TO NEGLIGENCE
@RanjeetKumar-jd9bc
@RanjeetKumar-jd9bc 2 жыл бұрын
@@arunharith thank you Sir
@vinodloyola2009
@vinodloyola2009 Жыл бұрын
Thank you sir
Quality Control - 2
31:42
arunharith
Рет қаралды 14 М.
Westgards rule - Quality control - Hindi
9:47
arunharith
Рет қаралды 35 М.
How to Fight a Gross Man 😡
00:19
Alan Chikin Chow
Рет қаралды 19 МЛН
Players push long pins through a cardboard box attempting to pop the balloon!
00:31
SIZE DOESN’T MATTER @benjaminjiujitsu
00:46
Natan por Aí
Рет қаралды 7 МЛН
Don't underestimate anyone
00:47
奇軒Tricking
Рет қаралды 26 МЛН
Why can we not use standards as controls ?
11:46
arunharith
Рет қаралды 11 М.
HbA1c estimation by HPLC
26:19
arunharith
Рет қаралды 10 М.
Practical Tips to Manage Laboratory QC Data
57:49
Labroots
Рет қаралды 7 М.
Quality Control in Laboratory | Standard | Control | Precision | Accuracy
25:09
Quality Control | LJ Chart | Levey Jenning Chart
16:35
Medical Lab Technologist Dinesh
Рет қаралды 71 М.
Standards, Controls and Calibrators
12:28
arunharith
Рет қаралды 69 М.
Chromatography and HPLC : Basic Principles
30:05
arunharith
Рет қаралды 3,3 М.
Hindi : Lipid Profile : Qs and Ans
26:55
arunharith
Рет қаралды 7 М.
How to Fight a Gross Man 😡
00:19
Alan Chikin Chow
Рет қаралды 19 МЛН