Your videos are very helpful for me, sir. Your explanation is excellent. I had many doubts related to quality control and other lab statistics, but now all doubts are clear. It will be a fortune to work under your supervision.
@gulwalikhan23262 жыл бұрын
thanx i like your all lectures love from pak khyber pukhtoon khwa
@shilpanagar90612 жыл бұрын
I am from Uk, working as biomedical scientist. Specially nowadays very hot in the Uk so QC giving very hard time. Temperature also affect QC results. When I have duty on analyzer it’s very important while doing maintenance as well beofre post cal and QC. We have Roche cobas 8000 c701 and e801. Also I worked p612,P617. 601. To be honest I loved to watch ur video sir. It’s really interesting
@arunharith2 жыл бұрын
Thanks
@geethasruthi57802 жыл бұрын
Thank you sir for starting this series.
@medicaleducation8978 Жыл бұрын
Crystal clear amazing lecture ☺️
@Captainlab012 жыл бұрын
Lots of thanks sir to start this series
@Rajesh_Jambhulkar Жыл бұрын
Great content, must watch👌
@monitsundriyal5752 жыл бұрын
Sir your lecture are awesome keep uploading your videos
@realmutsuddi93142 жыл бұрын
Nice lecture sir. #Bangladesh
@hariskhan-pd3qf2 жыл бұрын
Great Great Great. 👍🏻 Really informative lectures. Sir i request you that kindly start a certificate courses of Medical laboratory Quality control / Quality management. Thank you sir. Regards Haris Qurashi From Pakistan 🇵🇰.
@saviourlives252 жыл бұрын
Thank you very much for nice lecture sir 🙏🏽
@OmPrakash-yj9ek2 жыл бұрын
Jai Hind sir, thanks a lot for your valuable knowledge.
@rishikeshpandey39672 жыл бұрын
Thanku sir I am Rishikesh pandey from biochemistry technician from Medanta Lucknow
@arunharith2 жыл бұрын
Hi. Welcome
@MLT5821 Жыл бұрын
Sir, you made a complete video of Microlub 300
@Sukhmanjitsinghkhattra2 жыл бұрын
Awesome sir 🙏 please also share nabl daily and monthly procesing in lab record maintain and document for lab manager
@abhiishekkpal65042 жыл бұрын
Sir semi biochemistry ke graph pe bhi ek video bna dooo
@sourabhranjan27212 жыл бұрын
Waiting for next lecture 🙏🏻
@happyhunjan89042 жыл бұрын
Sir , Plz make video on seven quality tools 🙏🙏🙏
@sourabhranjan27212 жыл бұрын
Thank you so much sir 🙏🏻💖
@DharmendraKumar-jt7ir2 жыл бұрын
Thanks Sir
@vinayakbadiger26322 жыл бұрын
Thank you sir
@drrajjutiwari92678 ай бұрын
Sir please make a vedio on quality controll of CLIA, wheather both or all 3 level of qc need to pass to run the sample or we acan run the sample ifbonly one level qc is pass
@nirmalnvl Жыл бұрын
Thankyou soo much 🙏
@jsjohn2 жыл бұрын
When will English version come?
@alknishak52412 жыл бұрын
Thanks
@sayanichaudhuri54952 жыл бұрын
Sir Thank you so much for sharing knowledge. Sir I have a few queries - 1. Should Westgard rule 1(2s) be followed for same day run also? Eg In the morning qc run, I got 1 2s and same in evening run also, then will it be 2 (2s) or can we rectify it the next day? 2. When control goes bad and QC out, then do we have to calibrate (when reagent is not changed) before running fresh controls? 3. Do we have to calibrate before running controls, if same lot reagent is used in case reagent goes bad? 4. Westgard rule 4(1s) to be followed day wise or run wise?
@arunharith2 жыл бұрын
The rules are applied to every continuous run. Also if you are running 3evel control and 2 values are above 2s then also it is considered as 2s violation. So every consecutive run or even across the same run
@sayanichaudhuri54952 жыл бұрын
@@arunharith Thank you Sir
@the-official95215 ай бұрын
Sir R4s is a random error or a systematic error ,the R4s is a rejection rule right?
@RanjeetKumar-jd9bc2 жыл бұрын
Hello sir Thank you for valuable lecture Sir suppose i released critical result and dr took action on that result In that case when i get to know my qc is out so how will modify the result
@arunharith2 жыл бұрын
Partner. Run qc. If result fine then release reports. When qc fails. Stop testing. Correct reason for qc failure. Run qc to be sure system is fine. Do walk back studies to see if any patient result was impacted. If no well evey thing is fine. If yes call back the report. Release modified report. Inform pt and doctor. No way out. Hiding facts could create more problems. Walk back and modified report is a well accepted thing. ONLY ONE THING. THE LAST QC RESULT BEFORE THE SAMPLE WAS RUN SHOULD BE FINE. IF THERE WAS A QC OUTLIER AND U HAD NOT REACTED TO IT, THAT WOULD AMOUNT TO NEGLIGENCE