Radiant Floor Heat With A Water Heater

  Рет қаралды 173,120

Professor Gadget

Professor Gadget

Күн бұрын

How to make a Do-It-Yourself floor heating system

Пікірлер: 260
@carmencarrasco4714
@carmencarrasco4714 Жыл бұрын
I bought this water heater kzbin.infoUgkx8G49mV71sAzUl9shXyLW-r3XgHH9EVh1 for use in my bus conversion. I installed it under my kitchen sink and it is fed by a high efficiency on-demand LP water heater. It is both a backup hot water source as well as a water saving device since we have hot water on demand rather than having to wait for the gas on demand water heater to finish its ignition cycle. I decided on this water heater due to the fact that it only draws 1300watts when it's ON instead of the 1500 watts that most Water heaters this size draw. In an RV a couple hundred watts can be a big deal. With very low standby losses, I don't have to worry about excessive power consumption. When propane is not available for our gas water heater, in conjunction with our low flow shower head there is enough hot water available to shower, albeit we won't be taking "hotel showers." Also very happy with the recovery rate of this water heater. Granted, it is quite small, but it does exactly what we need it to do.
@Seeleeart
@Seeleeart 4 жыл бұрын
Hi Bill, Beautiful no-nonsense system you have there. And I agree that there is a complete lack of information on KZbin concerning heating your home like this. And you're smart to use a "closed" system. Great video.
@anthonyspadafora1384
@anthonyspadafora1384 2 жыл бұрын
Ill make this quick and to the point. Your circulator is installed incorrectly, you have the motor in the vertical position which allows air to get caught around the water lubricated shaft. Read your grundfos manual it has diagrams. Your circulator is not pumping away from the expansion tank. This means you are moving the water through your system with a negative pressure, this is why you are having air problems. Next, You are still using the 150 lb relief valve that came with the water heater, it is now a boiler and the relief valve must be changed to a 30 lb valve. If anything change that relief valve. Also corrosion in closed loop heating systems is caused by Oxygen. Oxygen is cooked out of the water in the first few hours, I work on systems that are over 100 years old and still rethread the steel pipe like it was new. On the other hand, Propylene glycol deteriorates into glycolic acid and must be tested yearly. Last but not least you left no way to isolate and drain your expansion tank for yearly air testing. This means you will have to drop the system pressure and introduce air just to check the bladder pressure.
@heavyduty3503
@heavyduty3503 2 жыл бұрын
isn't that horizontally installed?!
@Joe-tz3un
@Joe-tz3un Жыл бұрын
can I use car antifreeze in this system it is less corrosive
@anthonyspadafora1384
@anthonyspadafora1384 Жыл бұрын
@@Joe-tz3un No, that is ethylene glycol and is toxic.
@anthonyspadafora1384
@anthonyspadafora1384 Жыл бұрын
@@heavyduty3503 The pump is horizontal but the motor shaft is vertical.
@adamgruber2342
@adamgruber2342 Жыл бұрын
Holy shit it’s my favorite plumbing teacher! Ur the man Duke! Still loving Dan Holohan and John Siegenthaler ,thank u for all the knowledge!
@stevenbrewer4073
@stevenbrewer4073 3 жыл бұрын
I live off grid in north Idaho and I have used your information on my mountain home. It works great! I use propane and a wood heater to keep warm. Thanks to you for the post!
@davidmanishewitz
@davidmanishewitz 3 жыл бұрын
Hi ! I do too have off grid property ,and I'm thinking of using water heater to heat it, how much electricity does the pump use ? to power it with batteries , not to run the generator all day long
@pineridgegarage
@pineridgegarage 2 жыл бұрын
Hello Sir. I liked your video. Great job. Glad to hear the system is working. I notice the Grundfos pump is onstalled with the motor turned up vertical. If you read the Grundfos manual it will say that is NOT a way to mount the pump. The pump can be mounted horizontal like you have but the motor needs to be mounted on it side. Just rotate the assembly 90 deg. THe pump motor will last much longer. Infloor radsiant is the best.
@Grande.biggly
@Grande.biggly Жыл бұрын
I've been using the exact same set up in my shop for 25 years with no problems until the burner corroded up . 👍
@jenking5306
@jenking5306 3 жыл бұрын
Thank you for going over the normal stuff most people have questions to!!!!! This is a perfect go to video on how the system works. Now I finally have an educational tutorial to show folks! Thank you!!!!
@scottwebber652
@scottwebber652 3 жыл бұрын
I’ve heard similar stories. A grand or so for the water heater beats a boiler price all day n a diy accomplishment is by all means a blessing. The $5k u saved here got u something else. That’s kinda way of life I practice.
@professorgadget9153
@professorgadget9153 3 жыл бұрын
Thank you for your interest. The answer to some common Questions, I have a separate water heater for hot water. My gas bill for December 2020 was $48.31. The thermostat was set at 70 degrees. This is the 4th year I've had this system with no issues. I sized it based on my experience. For many years I lived in a 1000 square ft poorly insulated house that had a 64,000 BTU furnace in this area. So it seemed reasonable that a 60,000 BTU power vent water heater would work. It never runs anywhere near capacity, usually about 3.5 hours per day. If your instructions say to mount the pump differently DO IT mine did not.
@oscarballard7911
@oscarballard7911 3 жыл бұрын
If it works, that's what really matters! I run a wood Boiler to heat 3000 sq.ft and am going inside next season, as i'm tired of cutting, splitting, stacking and ash-ing 6-8 cords of wood a Winter. Your set up is as simple as it can and needs to be. Not good business for either, over-paid pipe-wrenchers and/or the plumbing fitting industries!! Like it
@ChristnThms
@ChristnThms 3 жыл бұрын
Seeing those numbers is the icing on the cake. Well done.
@LightGesture
@LightGesture 11 ай бұрын
You hit on a lot of points to this system... I honestly think your video is the most sensical one with information and basic workings of your system..... I don't have a heater, last winter it got to 22F in the house. Which we're from the city, we're used to a nice warm 70s in the winter... :O I'm trying to look at all what is there for a material list... 4 shut of valves, pressure meter, air separator, cold/hot manifolds, thermostat unit, water heater, antifreeze and some pex pipe with various elbows.
@oby-1607
@oby-1607 3 жыл бұрын
Just what I was looking for. I currently use a wood boiler to heat my house but have wanted to switch over to a hi-efficiency water heater instead so I don't have to continually fill the wood boiler. Like you, I have searched for an example to learn from and yours is an excellent system in its simplicity. I like it with few parts as that makes for less things to fail in the long run. Good job Professor Gadget.
@thomasopdahl1873
@thomasopdahl1873 2 жыл бұрын
one suggestion. If you have several separate zones, each controlled by its own thermostat, you can get by with a smaller water heater, since most of the time all three zones won't be calling for heat at the same time. You can also initially heat up each zone individually so the water heater will keep up with that high demand situation. Great video and explanation. Thanks
@TheTonyj30
@TheTonyj30 Жыл бұрын
this type of installations bring tears to my eyes , just because you could do it this way do`sent mean its a good idea
@rogerg4916
@rogerg4916 2 жыл бұрын
I installed almost exactly the same thing in my house back in the mid 80's which was unusual at the time especially here in Tennessee. It has worked well with little maintenance. I have exactly the same Grundfos pump and I have had to replace it once. Except for the in tubing in the slab I did all the above floor work myself. I only run my water temperature at about 100 degrees which was what was recommended at the time. I suppose the reason you only have to run it about 2-3 hrs. per day is because you have a 120 degree water temp.
@neckofthewoods24
@neckofthewoods24 2 жыл бұрын
so simple! you're right, not a lot on youtube and others look so complicated! thanks so much for this.
@jasonmayne1
@jasonmayne1 4 жыл бұрын
Just wanted to drop a thank you note for posting this video - definitely helped me understand the parts I was wondering about. Great set-up!
@paulmcroberts2059
@paulmcroberts2059 3 жыл бұрын
Good morning from Canada. I was looking over your system, and you should change the pump motor to the side. If you look at the manufacture instruction the motor has to be on its side. Here is a video to show you kzbin.info/www/bejne/i6fVg2iQdtCZZ5I To remove the air, install a drain cock before the return side ball valve and when you are filling, open the supply side, keep your return valve closed, and let the air come out of the drain cock. This works and makes this removal easy. Glycol, only use a propylene base. Looks good, but we recommend using the stainless of brass manifolds which have the flow gauge on them to show you have flow in all the loops. Water is tricky, it will take the shortest way back to the heat source. Enjoy the warmth as you are one of the smart ones that know you have a great heating system, that cost peanuts to run. Way to go! To help in figuring what size of a heater to use, take an average of 20 BTU's per Square Foot. (Example 1500sf x 20 = 30,000 required.)
@davebarfield7133
@davebarfield7133 3 жыл бұрын
If you could please explain the part about air removal in more detail I would really appreciate it. I built this exact system and started filling it tonight. I'm having trouble with filling and getting the air out. Thanks in advance
@stevepailet8258
@stevepailet8258 4 жыл бұрын
suggest you turn your pump so the shaft is not sitting vertically. The bearings will support the shaft if you have motor armature horizontal where the bearings can support the motor shaft. Just figured you would not want to need to change out the pump prematurely.
@andylarson3547
@andylarson3547 3 жыл бұрын
Cool idea, however, water heaters don't last as long and don't have as many sensors and safety devices as boilers. For others, looking to do this, do your research, there are many codes and rules for hydronics. Here's what's installed incorrectly: 1. should be a drip leg on gas line 2. TPR valve on water heaters are 150 PSI, should be switched out with a 30 psi boiler TPR. 3. Pump should be oriented 90 degrees and it should be on the supply side after the air scoop for proper air removal 4. Should be 18" of straight pipe before air scoop 5. Primary loop lines should be at least 1" for that many loops. 6. Galvanized fittings not recommend 7. Distilled water is not recommended in hydronics as it actually leaches metals from other items. 8. the cap on the air vent should be loose to allow air to escape. Pex should be oxygen barrier type 9. There should be a low water cut off device. If it leaks water and empties the tank, the air in the water heater can boil, ruin the water heater and create very high pressure
@michaelcee8348
@michaelcee8348 3 жыл бұрын
?
@johnpeters9903
@johnpeters9903 3 жыл бұрын
yes all of that and more. think of how much cleaner that install would have been if those incorrect manifolds would be turned around.plumber for 49 yrs
@trevorritchie2575
@trevorritchie2575 2 жыл бұрын
Did he do anything right or is it all wrong? I'm guessing it was cheap and works for him so maybe good enough ?
@JessicaBriarmoon
@JessicaBriarmoon Жыл бұрын
You sound super knowledgable. Im working on trying to design my system and discovered hybrid hot water tanks. We have 11000 sq feet in our building to heat. Though its the PNW and the typical heat requirement in winter is only 30-40 degree difference. Much of the loops will be kept near 60 degrees as they are rooms not being used much. But the main living space we will have it warmer. Do you recommend a closed loop system with the water and antifreeze or glycol? Then another hot water tank for the domestic usage?
@andylarson3547
@andylarson3547 Жыл бұрын
@@JessicaBriarmoon yes a closed loop system with antifreeze(glycol) with a dedicated boiler, and water heater for domestic. Or install a combi boiler
@notsure103
@notsure103 3 жыл бұрын
Nice and simple. I might suggest swapping those 2 copper manifolds for a radiant manifold. The radiant manifold doesn't need to be fancy but it will allow you to balance the flow of each run of pipe. They are very user friendly. There is a gauge for each run, just turn knobs till they are equal, then if you want you can turn up or down areas of the house to adjust comfort.
@markdeane1503
@markdeane1503 3 жыл бұрын
If all the PEX runs are the same length, 250' in this case, the fancy manifold is not necessary. I use them when there are many loops at different lengths and/or multiple zones on the manifold. Otherwise, copper manifold are fine and have far less resistance.
@Mike_Neukam
@Mike_Neukam 4 жыл бұрын
I imagine there is still air in the top of the water tank. I would think the easiest and fastest way to purge the air from the system would be to loosen the anode and bleed the air there. Nice setup, thanks for sharing.
@Mike_Neukam
@Mike_Neukam 4 жыл бұрын
@Hay Day I never claimed to be, but if you want to make an intelligent comment, maybe one of us will learn something.
@Mike_Neukam
@Mike_Neukam 4 жыл бұрын
@Hay Day troll
@Mike_Neukam
@Mike_Neukam 4 жыл бұрын
@Hay Day admittedly no, but I've been in a few water heaters and I know that on most of them, the outlet nipple has a tube that extends into the tank a few inches, leaving an area at the top of the tank that can trap air.
@lovethatbluegrassmusic9899
@lovethatbluegrassmusic9899 2 жыл бұрын
A way to make your hot water heater tank last longer would be to replace the anode rod annually. I am impressed with your system.
@tcap7917
@tcap7917 Жыл бұрын
Been heating my 1800sqft home with a 50 gal oil fired water heater for years
@calvinkalmon6746
@calvinkalmon6746 Жыл бұрын
WOW, really excellent video! I totally understand now...and just 10 minutes. Thank you so much!
@galaxy5008
@galaxy5008 3 жыл бұрын
Thank you for your simple but precise explanation Your The Man!!!
@spencerwilton5831
@spencerwilton5831 3 жыл бұрын
Clever, but can't help thinking a small, condensing gas boiler would have been simpler yet more economical. Open vented appliances are unavoidably inefficient due to the constant draft up the flue even when the burner is not lit. A sensibly sized gas boiler would modulate to the required load, and on a UFH system would operate in condensing mode the majority, of not all of the time. The system could also be dosed with inhibitor to protect the boiler and other components- given the volume of a water heater this would be impractical.
@naps3386
@naps3386 3 жыл бұрын
Look up the reviews on condensing boilers...very expensive (compared to conventional tank water heater), and they require yearly maintenance to descale, and they throw error codes and stop working frequently.
@steveedlund7357
@steveedlund7357 2 жыл бұрын
Nice job for helping the dying crowd. I'd like to point out a few things. The boiler, or water heater in this case, should be before the pump to properly vent the tank which is at the lowest pressure drop point in the system. Hydronic pumps are engineered for much higher water tends than your 120 degree supply. There would be a vent fitting such as the air scoop you have after the heater. The tubing used in a radiant system MUST be cross linked polyethylene with an oxygen barrier if any components in the system are ferrous metal, even with anti-freeze which breaks down over time and must be replaced. Thanks for posting.
@djwd1
@djwd1 Жыл бұрын
You need to rotate your pump 90 degree in the horizontal plane. Consult the manufacturer's instructions. It will fail prematurely if you don't. I have nine of them in my home, one for each of my seven radiant zones, one for my Burnham radiant boiler and one for the domestic hot water return line. My pump for the domestic hot water was originally installed the same as yours and it failed prematurely. You have a great heating system. I originally wanted to use hot water tanks for mine as they are more suited to radiant floors then boiler units, but the BTU calculation for my home was too high. I heat 4800 square foot of living space and a 1000 square attached garage. I believe my 110,000 BTU calculation was too high. In twenty years, I have never seen all seven zones calling for heat at the same time, not even during last week's blizzard.
@JessicaBriarmoon
@JessicaBriarmoon Жыл бұрын
I would love to see your set up. We have a bunch of zones and I'm trying to figure everything out myself. We have about that size on one floor, then a work floor with another bunch of sq footage, but most wont need heated much. Im looking at hybrid heat pump water heater. Anyway, Id love love to see your set up
@mrsmith2475
@mrsmith2475 3 жыл бұрын
If you had in line shut off valves on one side of the manifold you can fill one run at a time to eliminate air in the system. You can also control the flow if you get a area that's hotter then the rest of the house. You will always have a run that flows better then another. Just my 2 cents.
@constantreader7944
@constantreader7944 3 жыл бұрын
True! Cheap too.
@lesgallivan4159
@lesgallivan4159 3 жыл бұрын
I have a system for floor heat to supplement the forced air . Couple comments, mine has a separate loop for each room , a thermostatically controlled pump on each , so each room can be controlled separately. It is a closed system with a heat exchanger plumbed so the heat from the household water heater is used as heat source. It has a air bleed at the high point in each loop , just a tire valve like what is used on chloride filled tires
@sammosher1812
@sammosher1812 4 жыл бұрын
The only problem I see is that your pump motor is installed vertically and they say to not ever mount them in that orientation. Otherwise I really appreciate your detail and information!
@kensebring3683
@kensebring3683 Жыл бұрын
Excellent commentary. I love it when you say concrete. So many people say cement and and much rather walk on concrete then cement. Great job! I put two or three hot water systems in like that wood fired oil fired wood oil combo they talk about green energy. Should be a law and a new home in the cold zone of the United States should have radiant for heat. Save so many dollars.
@lovethatbluegrassmusic9899
@lovethatbluegrassmusic9899 2 жыл бұрын
I think your energy bill would be lower if you used straight distilled water and no anti-freeze. Also blow out the water annually from the hot water heater and PEX. It is just water, so it can go down the drain. This removes sludge from the bottom of the hot water heater. With your water heater depressurized, remove the sacrificial anode rod from the top of the water heater, replace it when it looks like it is being used up. You might want to replace this rod annually.. It is cheap insurance. If your pump needs to be oiled, this would be a good time to do so. Best wishes.
@kendallcarpenter5193
@kendallcarpenter5193 4 жыл бұрын
Mr. Professor Gadget, Thank you for this informative video. I was elated when I found it. You mentioned that a person could submit their floor plan to either nimco, nemco, or possibly nibco for a hydronic system layout. I was unsuccessful at finding where and how to contact the company you mentioned. I would appreciate some guidance. Once again, great video. Ken
@JonnyGuns
@JonnyGuns 2 жыл бұрын
Appreciate the video and info provided. My dad and I are about to set up something like this in the old house we're restoring.
@renebrossard
@renebrossard 2 жыл бұрын
Just bought a house with radiant heating. This is a big help. Good one! 👍
@rodneystorie2982
@rodneystorie2982 2 жыл бұрын
I use a similar system to heat my garage only I use my hot water tank from the house and mine is a open loop system so it's always using fresh water as hot water is used in house. Been running for about 12 years with no issues. Love radiant heat
@hieronymus..bosch8532
@hieronymus..bosch8532 2 жыл бұрын
My first hot water heater in my shop heater system lasted 25 years with glycol in the system
@huangsam00
@huangsam00 3 жыл бұрын
A reliable,simple, flexible, economical, low maintenance heating system. It will last 30+years i think except thermocouple replacement in 10 years. Lower the gas pressure to 3iwc and recover some heat from flue pipe will increase efficiency to 80+%. That is good enough but please install CO detector all times
@constantreader7944
@constantreader7944 3 жыл бұрын
Honestly, if you’re cheap, a tankless water heater works just as well as a boiler. Doesn’t have all the features, but when you get a unit with a good turndown ratio, spending $650-950 on a tankless is better than $4k on a boiler. The tankless units last about 7-10 years minimum if you use them for radiant. Then you switch it out for a new one. Cheaper than a maintenance visit or a repair for a boiler. More efficient than the big tank here.
@jenking5306
@jenking5306 3 жыл бұрын
I just use a propane hot water heater. Less parts to fail. Simple and cheap.
@trevorritchie2575
@trevorritchie2575 2 жыл бұрын
Can i use my existing 200,000 BTU natural gas tankless water heater for domestic hot water and add pex and a pump to heat my 20 x 17 garage floor?
@elliotmaleski5275
@elliotmaleski5275 3 жыл бұрын
Short and simple, excellent video!
@micmike
@micmike 2 жыл бұрын
That was great, easy to follow and a simple method of installation. Thans very much for your demonstration and lesson.
@unclemaple
@unclemaple Жыл бұрын
Excellent video and nicely done. I am always looking for the next project to do and this one looks like some fun. Great job !!
@neckofthewoods24
@neckofthewoods24 2 жыл бұрын
at 8:59 it looks like you tightened your air/water separator vent screw all the way down. i believe you want that loose so air that gets generated can escape. check your model though. mine you dont touch ever. its set from the factory.
@JeffHardie
@JeffHardie 4 жыл бұрын
Great video thank you. Would you mind answering a few questions. 1. How much did the Hot water tank cost. 2. How many linear feet is your 1 zone loop 3. Do you wish you would of installed multiple zones 4. Have you experienced where the the water heater would not keep up with heat demand. 5. What are your coldest months. Thank You so much. Where I am from WA, colder months can be below 10 deg at night. Thank You
@professorgadget9153
@professorgadget9153 4 жыл бұрын
The water heater cost about $600.00. The length is about1500 feet. No regrets, It is an open floor plan ranch house. On the coldest days in our area near Chicago the temperature can be below zero with single digit highs. We keep the thermostat at 70 degrees and the system runs about 50 percent of the time.
@JeffHardie
@JeffHardie 4 жыл бұрын
@@professorgadget9153 Thank You
@grabir01
@grabir01 10 ай бұрын
Its a closed loop system. We have hard water here. I use only water. My boiler heater and parts are 60 years old. Only had to replace the TACO and In Flow valve once in all this time.
@JohnODonovan1
@JohnODonovan1 8 ай бұрын
And why is it that you dont use antifreeze and what kind of water do you use, i'm assuming non distilled water.
@grabir01
@grabir01 8 ай бұрын
@@JohnODonovan1 Never turn thermostat lower than 55-60 so it can never freeze. and yes it is tap water in a closed loop system so the hardness is not a problem.
@JohnODonovan1
@JohnODonovan1 8 ай бұрын
@@grabir01 except for the times of year when the system is not on or needed?
@grabir01
@grabir01 8 ай бұрын
@@JohnODonovan1 True.
@jcohenmd
@jcohenmd 4 жыл бұрын
your pump is mounted horizontally which is recommended to be mounted vertically
@ricksherman9628
@ricksherman9628 4 жыл бұрын
You did a great job. Thanks for the info. It’s going to help me out a bunch
@phattz03
@phattz03 3 жыл бұрын
Thanks much,I have wood boiler and floor heat in my buildings I did myself, was wondering how to do a backup system with water heaters,looks pretty easy!
@DrivingWithJake
@DrivingWithJake 4 жыл бұрын
Great little video! :) I also like the drain pipe you have on there.
@guloguloguy
@guloguloguy 7 ай бұрын
WOW!!!! THANKS FOR THIS GREAT INFO, AND EXPLANATION!!.. I HAVE A SMALLER HOUSE, (IT'S ONLY ABOUT 864 SQ. FT.) I WANT TO INSTALL A SIMILAR "SIMPLE" SYSTEM, USING A "TWIN" HOT WATER TANK SYSTEM (ONE TANK (OR TANKLESS HEATER?), USING NATURAL GAS, THE ADDITIONAL "BACK-UP" HEATER WILL BE ELECTRIC ( SO THAT IT CAN BE HEATED FROM POWER FROM A "BACK-UP" GENERATOR, OR, COMED., IF NECESSARY.
@kotel-start
@kotel-start 3 жыл бұрын
Turn the pump 90 degrees. Or it won’t run properly and finally will break down.
@johnpeters9903
@johnpeters9903 3 жыл бұрын
correct he failed to read the directions
@neckofthewoods24
@neckofthewoods24 2 жыл бұрын
@@johnpeters9903 i believe they state they can run in any direction but in one direction the pressure has to be 20psi. he stated 18psi so hes under but probably why its been ok for 2 years. his also has the pump mounted lower than the water level so maybe at that height hes at 20psi while the gauge up top is only showing 18psi.
@mikevon7858
@mikevon7858 3 жыл бұрын
thank you so much , great video ,,, wonderful explanation , I learned a lot thanks for passing it along
@rogerwhiting9310
@rogerwhiting9310 3 жыл бұрын
I have 100percent radiant heat in my 1600 foot one floor home and 800 sf garage under it. I have an 11 zone manifold upstairs and a 4 zone manifold in the garage. I currently have a Buderus 115kbtu cast iron gas boiler that heats the radiant system flawlessly. I have 35 solar panels that cover my electric bill 99%. I am considering removing the boiler amd installing an 80 gallon HYBRID water heater because I want to add 35 more pv panels. My energy guru says that hybrid water heating is cheaper than gas or oil. I always thought that a water heater wouldn't cover heating my home... which is fairly well insulated. You may consider replacing the gas water with electric hybrid... and possibly a stainless storage tank to cover the slower performance of a hybrid wh versus gas. Nice video.
@deckmonkey1459
@deckmonkey1459 3 жыл бұрын
I can't imagine running an air conditioner is cheaper than gas or propane and you have to have a mild climate. It's -22 C here and dropping to -29 tonight without the windchill. A heat pump would never work here and gas is so cheap that electric doesn't make sense. I don't know how much solar panels are, but I don't think you will ever save any money buying enough to heat your water. You're probably better off using vacuum tubes even though they are a pain in the ass. And do you really have 11 zones in a 1600 square foot house? That seems insane and way more complicated than necessary. You should do a video on your house because it's a pretty different system.
@briankloc
@briankloc 3 жыл бұрын
What are all the zones for? Wouldn’t the garage be one zone? I’m starting to look at building my own system.
@deckmonkey1459
@deckmonkey1459 3 жыл бұрын
@@briankloc Looking at it again, I think he means loops not zones. The garage should have 4 loops controlled by as one zone by a single stat. You could have bedrooms and living areas as different zones but getting overly complicated anymore makes for more problems with no efficiency savings. You usually try to go 250 feet per loop to get 4 loops out of a 1000 foot coil with as little waste as possible. Getting a designer to design it isn't too expensive and guarantees it will work right.
@rogerwhiting9310
@rogerwhiting9310 3 жыл бұрын
@@briankloc the garage has 4 loops of pex in the concrete. All 4 loops are controlled by one thermostat.... but requires 4 zone valves.... one for each loop. It requires a 4 valve manifold.
@rogerwhiting9310
@rogerwhiting9310 3 жыл бұрын
@@deckmonkey1459 11 zone valves for 11 loops.. controlled by 4 thermostats. As far as the efficiency of the hybrid water heater... if it gets crazy cold like you describe I honestly think it would switch to resistance heat. The energy guru knows the numbers and for Massachusetts its cheaper in DOLLARS to heat water with a heat pump water heater than gas or oil. It really almost never gets below zero in my area south of Boston. Adding more solar panels to cover heat and a hybrid plugin car will have a payback date... the energy guru set that too. The PV system in place now covers 100percent of my electric for 5 years. I get a check quarterly SREC that pays me about $3000/ year just to produce electricity. The system will be 100percent paid paid off in 1 year... between SREC and electric bill payback. For the next 20+ years its all profit. I hope to add another 5 to 8 kwh system to cover water heating for heat and domestic hot water. I will need to remove my boiler and use a heat pump. It will require a standby tank for heat due to slower recovery time.
@rioborzelli7291
@rioborzelli7291 2 жыл бұрын
I am going to do this in my home . Great Natural gas option . I am replacing a Oil boiler and will do the same . Saving green all the way
@rodm5830
@rodm5830 2 жыл бұрын
Wow, very informative video. Thanks for sharing.
@cynthiapiscesgreen9521
@cynthiapiscesgreen9521 Жыл бұрын
If you have a electric hot water heater, can you have an on the floor? Or is it a violation?
@overseeingeye5207
@overseeingeye5207 2 жыл бұрын
Did the same thing to my house boiler went out companies wanted thousands so I cut it out and put in a water heater works great and since it’s electric if I lose power a small generator heats my home as is all is normal
@LLCStreetwise
@LLCStreetwise 2 жыл бұрын
So if antifreeze were run in the system, would you even need the anode? If not, it seems like it would be great port to install a pressure gauge and/or second relief valve. The reason I ask is that I currently have this setup in my home for a radiant system and the installer used the top anode port for this purpose. The tank has a mfg date of 1994 on it and just gave up last winter. It had been "repurposed" for radiant around 2007 at which point the anode had been removed. I should also add that regular water was only used in the closed system, along with a fresh water check-valve to make sure it always had water.
@dutchymon
@dutchymon 2 жыл бұрын
From what I know, anti freeze only inhibits, and slows down corrosion, I would still keep the anode as safeguard and install a gauge inline.
@greganderson6049
@greganderson6049 3 жыл бұрын
Super smart system! Very helpful video. Thanks!
@williamrobinson9653
@williamrobinson9653 3 жыл бұрын
I have a single zone system like yours, it has been operating for over 15 years now. I use a 40 gal. H/w tank my only issue with this setup is about every 6 or 7 years I have to replace the tank, never for leaking issues, always for gas valve or burner stuff. I'm on my 3rd tank now so other than that it is great! Heats a 400 sq foot office in my Pole barn. Cost about $300.00 a year to so. Around 300 gal. of propane. And by the way your pump is infact mounted wrong it should be vertical? Thanks
@sfi382
@sfi382 3 жыл бұрын
What does it cost to heat your house for a month
@lou198
@lou198 3 жыл бұрын
You should have a pressure regulator and a non return valve connected to water supply if you develop a leak and run out of water you have created a bomb also most water heater corrode due to electrolysis change anode as recommended
@jonathansgarden9128
@jonathansgarden9128 2 жыл бұрын
This is super helpful for me, thank you.
@clars7146
@clars7146 3 жыл бұрын
... A couple of people have mentioned that your pump is installed improperly… The pump itself can be mounted horizontally or vertically what is important is that the shaft of the rotor is on a horizontal plane rather than the vertical plane you currently have it installed... simply rotate it 90 degrees! You have made several errors in your piping and I don’t recommend using a hot water heater as a heat source… But I gave up trying to argue these points 30 years ago! Enjoy your heating system, it very well may last 20-25 years!
@rv4891
@rv4891 3 жыл бұрын
I'm in the process of installing an in floor heating system and wondering why a hot water heater is not a good way to go. If you say it may last 20 to 25 years then why do you not recommend a hot water heater? 20 to 25 years of service sounds like a pretty good run for a heating system. Willing to listen to any good arguments pro or cons. Thanks for any advice.
@clars7146
@clars7146 3 жыл бұрын
@@rv4891 ...unless the unit is rated as a space heating appliance it wont pass inspection in many areas...it would depend on the authority having jurisdiction in your area. Also in Canada many mortgage companies will balk on this kind of system. USA I don't know? A hot water heater by design is not very efficient. Capital costs vs operating cost... I have been doing this since 1975 so I have seen a lot of things that work and a lot that don't! There are a few basic ideas that should be followed and this system will work a long time. Not sure how to get in touch with each other but I would be glad to help.
@toddt8446
@toddt8446 3 жыл бұрын
@@clars7146 Would a heat pump type water heater be any better? I will be installing floor heat soon in a 40x60 pole barn. Not sure if I will find a water heater with enough BTUs to do that. It will be very well insulated. I figure the cost difference of a water heater vs a boiler is worth a try.
@bahopik
@bahopik 2 жыл бұрын
@@toddt8446 heat pump heater takes heat from air that surrounds it. It's like trying to fill up your tank by draining fuel from it.
@richardsargent113
@richardsargent113 Жыл бұрын
Thank you Sir,, A great place to start!!
@halleluYAH144
@halleluYAH144 Жыл бұрын
Simply put. Thanks boss!
@strokerscamp
@strokerscamp 2 жыл бұрын
Very good explanation!!
@alberthoogendoorn2396
@alberthoogendoorn2396 Жыл бұрын
I build a hydronic floor heating system for 900 sq ft living space , I also need the GE hot water tank for the kitchen and bathroom. It is 11 years old and work perfect. The hot water tank ( 60 gallons ) get maintained regularly and have a 12 years guaranteed live, but by the looks of it ,it will last longer. Now I build a new home 2 floors with 4 bath rooms and heat it with a Rheem retex 06 electric tankless water heater.and in each floor is 1100 lin feet 1/2 pex line. Each floor is 3” ( 7.5 cm ) thick. The wals are 2x8 thick insulation and the ceiling of the top floor is R 63. Total water amount in each floor is approx 45 liters of water and it is a closed system. For the bathrooms and kitchen etc I have a natural gas Rheem on demand water heater. Electric is better for the environment than any thing else. I really do not know the cost per season because I have not used for a long time , we started the system the end of Sept 2022 and had set the temp 27 Celsius in the floor and the temperature in the home is 23 Celsius. At night we do not set it lower. We love it.
@craighoff3009
@craighoff3009 2 жыл бұрын
Thanks for the great and simple video. I'm doing the exact same set up in my shop. My question would be is how much antifreeze/water goes in the water heater? Mine is a 40 gallon. I have my lines in the floor filled and most of the air purged out just not sure of the water heater.
@talonpilot
@talonpilot 2 жыл бұрын
Just read the instruction on the back of the antifreeze jug about mixture ratios; it all depends on where you live BUT since you aren’t using this in a cars radiator, I’d venture to say you can go thinner than recommended (aka use less antifreeze since the system will be “inside”). An average car takes a 50/50 ratio for “normal” climates. Add more or less based on the jug recommendations. if you do go buy antifreeze, buy the concentrate and not the premixed kind as you will be needing LOTS of it and you’d also just be buying 50% water with the 50/50 mix…. It’s great for topping off cars in a hurry but when changing the whole system out, you’re just wasting money.
@wbeckmann6965
@wbeckmann6965 Жыл бұрын
The two 90 PEX elbows at the manifolds totally unnecessary and adds flow restriction. Vertical shaft on pump not good.
@louiseruffo1345
@louiseruffo1345 3 жыл бұрын
The pump is installed incorrectly. The motor should never be mounted on top. You should rotate the pump and the flanges. The bearings should not be on top.
@charlesarmstrong3536
@charlesarmstrong3536 2 жыл бұрын
Please explain.
@bahopik
@bahopik 2 жыл бұрын
@@charlesarmstrong3536 it's a wet rotor pump, so water acts as a lubricant, with motor facing up, it can create an air pocket and rotor wouldn't be lubricated on one end. Every pump manufacturer has acceptable mounting positions listed in the installation instructions
@ffbells
@ffbells 2 жыл бұрын
It should also pump away from the “boiler”. Those pumps are made to pump 180 degree water,so the temp of the water is no concern.
@us-unclesam6566
@us-unclesam6566 3 жыл бұрын
How much did the water heater cost?
@warrenwalker8170
@warrenwalker8170 6 ай бұрын
If you only have a handful of metal fittings you may as well splurge and use stainless steel ones instead of galvanized. Also your fill and vent line should have caps in case some fool opens the valves
@joelalleman9591
@joelalleman9591 3 жыл бұрын
I would like to build a system with a propane hot water tank . I am using a wood stove to heat my water now in an open system , would like an open system on my hot water heater too. An open system is so much simpler !! Any advice??!!!
@soulshakerman
@soulshakerman 3 жыл бұрын
Thank you so much for this! very informative
@ralphmickelson4429
@ralphmickelson4429 2 жыл бұрын
Thank you for a great video. How much did you spend for gas and electric last January?
@kjterz
@kjterz 2 жыл бұрын
how much does it cost to run................................
@kirkyorg7654
@kirkyorg7654 3 жыл бұрын
pretty simple set-up its funny how the companies that sell and install this try to sell you so much crap you don't need
@stevelemelin4140
@stevelemelin4140 2 жыл бұрын
What thermistat did you use and why did you pick the one you ended up using?
@davet7663
@davet7663 2 жыл бұрын
Great video. Thanks for the info 👍
@ronwest7930
@ronwest7930 4 жыл бұрын
It all looks pretty common sense. I would wrap insulation around the pex pipe.
@paulrite5358
@paulrite5358 Жыл бұрын
Please tell me about the expansion tank. How did you size it?why is it where it is?what does it actually do. Is there anything inside of it?
@mwrcrft
@mwrcrft 3 жыл бұрын
Thanks for sharing
@marcruel9401
@marcruel9401 Жыл бұрын
Is this a new construction? If not how did you radiate heat in the house
@noccis3448
@noccis3448 2 жыл бұрын
Great video. Thanks.
@chevman46
@chevman46 5 ай бұрын
How much ...kwh per month during the coldest part of the year ...does ur system use ...???
@0ffGridTechClub
@0ffGridTechClub 9 ай бұрын
Awesome! I gotta try this out
@briancorbett1285
@briancorbett1285 3 жыл бұрын
this guy is awesome
@danielz722
@danielz722 4 жыл бұрын
How much is your gas bill with this setup? I've got an old boiler and in January with a Delta T of 34°F my gas bill was over $286. I'm curious about the change with using a water heater instead. But I cannot seem to find relevant research or journal detailing the cost variance between a boiler and hot water heater.
@professorgadget9153
@professorgadget9153 4 жыл бұрын
It has been a mild winter in our area, Wilmington Illinois. We use gas to heat our water, dry our clothes and cooking. My bill for the last month was $46. Ther are only two of us living in the house.
@danielz722
@danielz722 4 жыл бұрын
@@professorgadget9153, thank you for the quick response.
@tenwalls2428
@tenwalls2428 Жыл бұрын
Good job!
@stevenpatriquin3188
@stevenpatriquin3188 2 жыл бұрын
so simple,i like it
@jamesstewart4203
@jamesstewart4203 3 жыл бұрын
I saw in another video that the pump piston should be horizontal not vertical...
@comodrone49
@comodrone49 4 жыл бұрын
Great video. What model is the water heater... do you recall what it cost? Is it just a regular water heater?
@professorgadget9153
@professorgadget9153 4 жыл бұрын
It was a high efficiency Richmond 29 gallon. It had a 12 year warranty and the specs said it was good for hydronic heat. I think it was around $600
@kickinghorse2405
@kickinghorse2405 2 жыл бұрын
Thank you!
@MrStatic101
@MrStatic101 3 жыл бұрын
Wow so this is a closed system. Does the system ever need to be topped off? On a regular boiler there’s a fill valve that allows it to fill as needed or if needed. Do you have to check it to see if it’s low?
@bahopik
@bahopik 2 жыл бұрын
If there's a pressure reading on the gauge, it has water in it, assuming that the gauge isn't stock. Otherwise if water heater is hotand pump is running, but floor is cold, you know you have a problem
@realgoon8373
@realgoon8373 2 жыл бұрын
Do you have a link on where to get the set up. How much it cost. Does it heat your house or just the floor. How much much your bill per month to run it
@rogerg4916
@rogerg4916 2 жыл бұрын
When you heat the floor you ARE heating the house as heat radiates up from the floor heating everything in the house.
@realgoon8373
@realgoon8373 2 жыл бұрын
@Roger G ok thanks. Where can I order a set up.
@rogerg4916
@rogerg4916 2 жыл бұрын
@@realgoon8373 Just search for hydronic radiant floor heat systems. You should find several reviews on KZbin.
@realgoon8373
@realgoon8373 2 жыл бұрын
@Roger G ok thanks for replying willl contact if have more question cause we have my blocks down ima go head get my hear set up now
@JonathanDerenzo
@JonathanDerenzo 9 ай бұрын
Your average boiler is set at 180 degrees Fahrenheit, unfortunately the highest a residential water heater gets is 160 degrees Fahrenheit IF no one is taking a shower or washing clothes. A residential water heater can and WILL work for radiant heat but during CRUNCH hot water time's like when a family is showering or washing clothes you will not get heat.
@BeeHiverson
@BeeHiverson 9 ай бұрын
this appears to be a separate unit
@JohnODonovan1
@JohnODonovan1 8 ай бұрын
Its a dedicated heater
@JohnODonovan1
@JohnODonovan1 8 ай бұрын
Its a dedicated heater
@kameljoe21
@kameljoe21 7 ай бұрын
Dedicated heater for one and tempature has nothing really to do with it. BTU ratings have more to do with it than anything. For example if you had a 100k btu heater it would heat up twice as fast. 200k btu heater 4 times faster and so on. You can use a electric water heaters as well. There are some really nice water heaters out there that are pretty good. Look for ones with higher kwh ratings as they will have the highest btus. For example a 40g 4kwh water heater is only 400 dollars. If you need more heat then add another one in line. Its far cheaper than a boiler and cheaper than a higher rated water heater. Even the cheapest set ups are going to be super easy. The pipe and fittings are really super cheap if you look hard enough. All you need is a recirculate pump which can be had for 100 dollars, water heater 400, thermostat plug in switch 50 (plug the pump in to it and it turns on and off when it hits the temp), pex 1000 feet 250, fittings 250. For a bit over a grand you can install radiant heat in to your slab. Add tax and adjustment for location and better stuff you could be in the whole system for less than 2500 dollars.
@BeeHiverson
@BeeHiverson 7 ай бұрын
@@kameljoe21 tldr
@mikejackson6862
@mikejackson6862 3 жыл бұрын
Awesome thank you so much! I have a shop with in floor heat and I haven’t been able to use it because plumbers want over $10,000 to hook the boiler to it. I just found a Rheem right 100 gallon commercial water heater. My floor is 2800 square feet. How did you find out how big your water heater needed to be?
@dugfern
@dugfern 3 жыл бұрын
20 btu's per sq. ft. of floor.
@notsure103
@notsure103 3 жыл бұрын
A whole lot of math.
@notsure103
@notsure103 3 жыл бұрын
What region are you in? Ceiling height? Insulation? Are you likely to have a bay door open every 5 minutes? 20btu sqft sounds pretty low to me. Unless it's well insulated and tight I would aim for 30, your zone is really important to know.
@johnpeters9903
@johnpeters9903 3 жыл бұрын
dear mike jackson, you need to contact a plumber or supply house to fill in all of the variables involved with infloor heat or else you are just throwing darts at a target with no real idea of how the final product will turn out.
@cryptogringo2440
@cryptogringo2440 2 жыл бұрын
Can you post a list of all the parts, thank you.
Simple In Floor Heat
10:46
Country Family Homestead
Рет қаралды 73 М.
Amazing Radiant Floor Heat | One Year Update & System Costs
14:02
Little Mountain Life
Рет қаралды 433 М.
Just Give me my Money!
00:18
GL Show Russian
Рет қаралды 1,1 МЛН
Dad Makes Daughter Clean Up Spilled Chips #shorts
00:16
Fabiosa Stories
Рет қаралды 8 МЛН
Bike vs Super Bike Fast Challenge
00:30
Russo
Рет қаралды 23 МЛН
Can you Heat your Shop with a $200 Water Heater? Radiant Floor Heating For My Shop | Allison Customs
46:00
radiant floor heat small hot water tank
12:44
Robinson Homestead
Рет қаралды 31 М.
simple radiant floor heat update and review
13:46
Robinson Homestead
Рет қаралды 10 М.
EASY FLOOR HEAT (using a new or used hot water heater!)
7:43
This guy
Рет қаралды 213 М.
Start-to-Finish Radiant Floor System (by DIYers) 🔥
40:39
Mason Dixon Acres
Рет қаралды 90 М.
4 Methods To Run Radiant Heat PEX Pipe
23:00
Matt Risinger
Рет қаралды 355 М.
Can you heat a house with a water heater????
10:43
Bondo Built
Рет қаралды 27 М.
Installing DIY Radiant Heated Floors by VanLife Tech
15:01
Tory Delury
Рет қаралды 119 М.
DIY In-Floor Hydronic Heating System Using Water Heater
18:17
Plug and Play Radiant Floor Heating System - BEST ON THE MARKET
13:15
Matt Risinger
Рет қаралды 562 М.
Just Give me my Money!
00:18
GL Show Russian
Рет қаралды 1,1 МЛН