Radiant Tube Heaters - Theory Of Operation (Startup)

  Рет қаралды 56,581

TheDurbinCompound

TheDurbinCompound

Күн бұрын

Пікірлер: 106
@17madracki17
@17madracki17 16 күн бұрын
Ive got a 60 ft in my 60x40 shop its new but there is an old one hanging beside it and i thought u gotta take that down and sell it. Now i know how to check it and sell working. Thanks for your time to share with all of us.
@welderman5844
@welderman5844 2 жыл бұрын
I feel like I’m an expert in radiant tube heaters now . Great stuff . Now I’m going to attempt to diagnose my shop heater with this info
@TheDurbinCompound
@TheDurbinCompound 2 жыл бұрын
Good luck, god speed
@yay4meluigi
@yay4meluigi 24 күн бұрын
Great video. I’ll have to decide if I feel comfortable messing with mine.
@kentdixon5716
@kentdixon5716 2 ай бұрын
Best trouble shooting video out there!! I bypassed that diaphram air switch and bang, works like a charm, thanks for saving the money of a tech to come out and maybe fix it honestly , and maybe not? i never trust these people, thanks again for taking the time to post the video, you explained the theory of how they operate very well, cheers from Calgary Canada.🙂
@TheDurbinCompound
@TheDurbinCompound 2 ай бұрын
You should be able to find a pressure switch fairly easily and you’ve already done half the work to swap it out
@aniawilliams8447
@aniawilliams8447 2 жыл бұрын
Thank you for the awesome explanation and guiding us through the parts diagram. I am in facility management and this helps me very much in understanding my HVAC techs language and explanations. Thank you !!!
@TheDurbinCompound
@TheDurbinCompound 2 жыл бұрын
Awesome!
@qkitselectronics5415
@qkitselectronics5415 4 жыл бұрын
7:00 Just thought I would mention, a transformer can only output AC, you mentioned DC, however unless that transformer has a bridge rectifier (4 diodes) it will output AC. The voltage is only present when the input is swinging from -55 to +55 volts on each side (total swing of 110). If you apply DC to the input of the transformer it will not output anything. The output voltage is only present when the magnetic field around the iron core is collapsing, thats why it has to alternate. When a coil gets saturated (in other words the field is not expand or collapsing) it just starts getting hot and will eventually melt or burn up. There are other factors, but that's it in a nut shell. Thank you for taking the time to make this video , edit it and post it. Have a great day. Hopefully it is AC as in my heater and I have not lead anyone astray. My fault turned out to be cold or broken solder joints on 2 of the relay contacts, on the printed circuit board. Any device that vibrates is likely to develop these types of faults. Also the relay contact is a mechanical device and also vibrates when switched which adds to the issue. If the board is double sided its not as likely to develop these as a single sided board would, the holes are plated through on a double sided board and as such the joint is much stronger.
@TheDurbinCompound
@TheDurbinCompound 4 жыл бұрын
Right! I had misspoke about the output. It is AC.
@orvillemorrison3236
@orvillemorrison3236 2 жыл бұрын
Great information thanks a lot you are very good explaining the stuff easy to follow
@tannerpetrie
@tannerpetrie 4 жыл бұрын
thanks for your help! I'm not runnin yet, but now I know how to diagnose!
@ryanrosehorsemanship
@ryanrosehorsemanship 4 жыл бұрын
This was very helpful. Thanks
@rickytruong5994
@rickytruong5994 4 жыл бұрын
I got a lot of good information from this video thanks for the gold!
@tommounts9889
@tommounts9889 3 жыл бұрын
Great Vid, very helpful for the operation of the unit. Just a small edit is needed...... Transformers put out AC voltage, Not DC voltage..... But great operation principles...
@mark.r8900
@mark.r8900 11 ай бұрын
Great video. My unit works ok. But the fan is always running. It never stops. Do you have any ideas? Thanks
@anjatrdin8499
@anjatrdin8499 Жыл бұрын
Hi, thank you for the video :) do you maybe have an idea what could be wrong if the pressure switch works and the gas valve opens the orange light lights on but then it goes into blockade. This is only happening in the morning (when we get the heater to run it works without any problem for the rest of the day)?
@orange_ash6902
@orange_ash6902 11 ай бұрын
How does it know when flame is on, is there a flame sensor located somewhere or did I miss this?
@krystopherfischer2919
@krystopherfischer2919 5 күн бұрын
My heater fires up for a couple seconds then shuts off, it is getting gas. Do you think it can be the ignitor switch? I can see through the glass that it is heating up then fires then shuts down. thanks.
@TheDurbinCompound
@TheDurbinCompound 4 күн бұрын
Flame sensor is dirty. If the fire is on for a couple seconds, then shuts off, the computer is not seeing the flame. Thus shutting it down for safety
@redsand848evo
@redsand848evo Ай бұрын
I have a pair of vantage 2s, the longer one goes through all the steps to the point of clicking the gas on. Well I should say it's random, sometimes it'll click on and run for a minute or so then shut down other times it'll come on and run until it hits the set temp then when it calls for heat again the gas won't click on. Any thoughts?
@mattjividen1610
@mattjividen1610 16 күн бұрын
What happens if the tube itself may be partially plugged up or too high of pressure. Is thete another air switch to measure this?
@briangagen8436
@briangagen8436 3 жыл бұрын
Informative and Direct. Thank you sir
@benmccallum8974
@benmccallum8974 4 жыл бұрын
Great explanation. Appreciate you making this video my man!
@TheDurbinCompound
@TheDurbinCompound 4 жыл бұрын
I appreciate your comment even more! Fuels the fire to keep trucking! Hope to see you around the channel
@72racecar
@72racecar 3 жыл бұрын
will these type of heaters be good for a garage with a 9 foot ceiling ?
@TheDurbinCompound
@TheDurbinCompound 3 жыл бұрын
These heaters usually have a minimum clearance under them at around 36-44”. So consider everything at 6ft high under the heater to be too close. That’s combustible minimum distance. So imagine how hot it would be at the 6ft Mark. I’d recommend against it
@coopermuccio4409
@coopermuccio4409 Жыл бұрын
Is there a flame sensor on these
@danschindler7080
@danschindler7080 4 жыл бұрын
Nice video covering the basics. That burner is an older Roberts-Gordon VANTAGE® II heater.
@jeenu1313
@jeenu1313 3 жыл бұрын
Thank you so much for the information. I have gasmac tube heater it turns on for 4-5 seconds and then turns back off. Any idea what could be the problem?
@TheDurbinCompound
@TheDurbinCompound 3 жыл бұрын
Flame sensor. It sounds like it is not recognizing that the flame is lit and shuts down for safety.
@jeenu1313
@jeenu1313 3 жыл бұрын
@@TheDurbinCompound Thank-you so much for replying me back. I did clean the flame sensor really good but it still does the same thing. Do you think I should just change it to new one ??
@TheDurbinCompound
@TheDurbinCompound 3 жыл бұрын
Possibly. It might be the circuit board if it is not keeping it on and the sensor is clean. You could get a new one and if it still does it, could be the board.
@jeenu1313
@jeenu1313 3 жыл бұрын
@@TheDurbinCompound Thank-you so much. I really appreciate your help.
@scottwaite501
@scottwaite501 Жыл бұрын
Great of overview.. thanks
@pzito1
@pzito1 7 ай бұрын
Should the tube turn red or no. I have a tube heater doesn’t turn red. Why and ty
@TheDurbinCompound
@TheDurbinCompound 6 ай бұрын
The tube should not turn red. If it does, it’s not getting good airflow.
@howardharaway2259
@howardharaway2259 4 жыл бұрын
Just worked on my very first tube heater at a "Shoprite " Wilmington Delaware. Inducer seized. Gas valve is a "smart valve" ?
@careyblanchette8351
@careyblanchette8351 5 жыл бұрын
Thanks man. Gotta follow ur other videos.
@TheDurbinCompound
@TheDurbinCompound 5 жыл бұрын
That would be awesome! Click that subscribe button and I’ll see you around the channel!
@josephflemington4478
@josephflemington4478 2 жыл бұрын
Very informative video. Thank you.
@thermus
@thermus 5 жыл бұрын
Nice explanation, thanks. Do you know how the controller knows that there is no gas in the line after turning the igniter on? In foundry furnaces the gas safety sensor is located near the igniter (via ionization spark-plug or photocell). I dont see either of those in the video. Also, do you know the BTUs of the heater in your video?
@nathaniellarson8
@nathaniellarson8 3 жыл бұрын
Awesome video, thanks!
@TheDurbinCompound
@TheDurbinCompound 3 жыл бұрын
It’s getting to be that time of the year again!
@nathaniellarson8
@nathaniellarson8 3 жыл бұрын
@@TheDurbinCompound My wife and I bought a place this summer with a heated shed and I tried to turn the heaters on a couple of weeks ago but they did absolutely nothing. Watched this video and figured out there had to be a breaker off somewhere, there was. One heater works, the other one... well I'm gonna have to watch this video at least one more time 😂😂😂
@adame5238
@adame5238 4 жыл бұрын
Thanks- great video!
@generaluser4145
@generaluser4145 11 ай бұрын
It may sense th3 flame through flame rectification on the ignitor
@toddmuddywaters
@toddmuddywaters 2 жыл бұрын
What about flame sensing on a unit like this?
@johnfalcones9463
@johnfalcones9463 2 жыл бұрын
bro can I leave the burner running without the pressure switch, bypassing the two cables, only until the spare part arrives?
@roadrunnerorange
@roadrunnerorange 3 жыл бұрын
Great vid! I have a big overhead infrared heater, turns on with thermostat, kicks on, but stays very low with no lights on (low and high). Its a re verbaray hl2-20-75n. Any suggestions?
@TheDurbinCompound
@TheDurbinCompound 3 жыл бұрын
Sounds like a control board issue. So it’s firing and getting hot, just not getting as hot as it should?
@roadrunnerorange
@roadrunnerorange 3 жыл бұрын
@@TheDurbinCompound yes, with no low or high lights as was normal. Thanx for the fast reply!
@TheDurbinCompound
@TheDurbinCompound 3 жыл бұрын
Sounds like it’s a control board issue. Could also be the gas valve. The valve would be what is turned up and down with the control board for either high or low. The control board could be telling the valve that it should be on high and it just won’t open enough. OR the control board is not telling the gas valve to open or close. It’s a crap shoot without looking directly at it and testing voltage at the board with it running.
@dungareekogi2442
@dungareekogi2442 3 жыл бұрын
I have these in my poultry houses for 10 seasons now and they have been working great. But over the last two seasons I've noticed a dramatic drop in efficiency. It takes a long time to warm up the house as opposed to before when it was blistering hot within minutes. I try to to maintain it by keeping it dust free around the tube and the canopy before each use. Is there anything else I need to do to maintain?
@MrBillbuster
@MrBillbuster 2 жыл бұрын
Your tubes might be full of carbon,they will need to be cleaned every year or at the least inspection of them is needed and clean your intake and exhaust vents.
@hugostiglitz6823
@hugostiglitz6823 3 жыл бұрын
Any idea why my reznor tube unit got so hot it was glowing red and partially melted the heater box?
@TheDurbinCompound
@TheDurbinCompound 3 жыл бұрын
Yikes! Sounds like an air flow issue. Exhaust at end clogged?
@hugostiglitz6823
@hugostiglitz6823 3 жыл бұрын
@@TheDurbinCompound no its not but there are those baffel things in a section of the tube. No one works on these things as I live in a small rural town so I'm kinda fucked. It still runs its Just warped and shit. 🤷‍♂️
@nicolasskrzypczak6164
@nicolasskrzypczak6164 4 жыл бұрын
Thanks a lot. I learned how that thing works. Son and I will trouble shoot tonight... I am betting it is the ignition.
@nicolasskrzypczak6164
@nicolasskrzypczak6164 4 жыл бұрын
Would you recommend that we take the unit down and troubleshooting on the bench like you did or troubleshoot in place? It seems easy enough to remove the unit.
@TheDurbinCompound
@TheDurbinCompound 4 жыл бұрын
Whichever you’d like to do. If your ladder is stable, it should be easy enough.
@jimfash2881
@jimfash2881 4 жыл бұрын
We have a new automotive repair shop with these already installed...is there a specific clearance to a vehicle on a lift in close proximity to heaters??
@TheDurbinCompound
@TheDurbinCompound 4 жыл бұрын
Yes! There is usually a chart on every single model. I just looked at one yesterday. It was a 190,000btu (huge 70ft model). The clearance within 20’ of the burner was 94”. After that the clearance is 44”. So you definitely need to check the manual so you don’t burn up some paint!
@jimfash2881
@jimfash2881 4 жыл бұрын
@@TheDurbinCompound thank you we have no manuals tho as this was an existing shop which was vacant
@TheDurbinCompound
@TheDurbinCompound 4 жыл бұрын
A brand and BTU rating off the sticker will get you a long ways on the internet
@jimfash2881
@jimfash2881 4 жыл бұрын
@@TheDurbinCompound I gotcha Bro thats why i started here..thanks bunches
@TheDurbinCompound
@TheDurbinCompound 4 жыл бұрын
Good luck! These radiant tubes provide the best heat in my opinion. Can’t be beat
@jordancarbone9170
@jordancarbone9170 Жыл бұрын
Thanks homie
@lewiscassady8704
@lewiscassady8704 2 жыл бұрын
What if it runs for a couple min. and shuts down?? Thanks
@TheDurbinCompound
@TheDurbinCompound 2 жыл бұрын
Most likely the flame sensor
@justinbowles4671
@justinbowles4671 5 жыл бұрын
Can I use regular B vent for water heaters to vent this style of heater out to the. Atmosphere?
@TheDurbinCompound
@TheDurbinCompound 5 жыл бұрын
Yes you can. Same theory as a water heater. Except for the tube isn’t surrounded by water
@justinbowles4671
@justinbowles4671 5 жыл бұрын
Awesome! I appreciate it!
@TheDurbinCompound
@TheDurbinCompound 5 жыл бұрын
Common sense applies. Make sure you don’t pipe up against anything flammable! 🔥
@justinbowles4671
@justinbowles4671 5 жыл бұрын
What about a thermostat? Can I just use one that I was use for a house? Sorry for all of the questions!
@TheDurbinCompound
@TheDurbinCompound 5 жыл бұрын
Yeah for sure. Same theory. Two wires, red and white.
@libertybarker7401
@libertybarker7401 5 жыл бұрын
what if i come into my shop and turn on the lights and the shop explodes? because the fire went out and gas kept going. the igniter must stay on at all times or even a hiccup(momentary lose of flame) in ignition can cause a gas acumulation in the shop.
@happyindian3282
@happyindian3282 4 жыл бұрын
a photocell can be incorporated, with the help of a programmer, to prevent the flow when there is no light (flame).
@dalejrfan820002000
@dalejrfan820002000 5 жыл бұрын
I have a question my tube heater fan is plugged into a outlet. But the thermastat is wiring through what looks like a outlet. Witch looks what powers the blower. My question is I thought the thermastat is wired to the main furnace?
@Cody-mu5sj
@Cody-mu5sj 5 жыл бұрын
robert nealey thermostat wire is sending low voltage, (24v) outlet is sending line voltage
@dalejrfan820002000
@dalejrfan820002000 5 жыл бұрын
@@Cody-mu5sj Thanks I just never seen such a thing.
@MichaelJeffers75
@MichaelJeffers75 3 жыл бұрын
Do you know if anybody sells the entire unit without any of the tube and reflectors? I want to build a DIY asphalt heater that would need to be controlled like that and have a mild stream of air.
@RickReck-ci7lh
@RickReck-ci7lh Жыл бұрын
Hey mine kicks on but then it shuts off
@howardharaway2259
@howardharaway2259 4 жыл бұрын
My question is,after it runs for awhile on roughly a 25' tube,should the tube look orange HOT ? I kind of think not. Commercial Property maintenance told me he "kind of" remembers this heater glowing Hot. I can't see that would be the case seeing how small the gas valve was and length of heat exchanger tube.
@TheDurbinCompound
@TheDurbinCompound 4 жыл бұрын
Well the first tube from the burner is supposed to be titanium to keep from turning orange. You should be ok but the heat cycles on a standard steel tube will weaken it in time
@luissalinas2538
@luissalinas2538 4 жыл бұрын
Why a blower keep running all time
@connorbaker8372
@connorbaker8372 3 жыл бұрын
Mine starts up and then turns off and on off and on what do you think this is
@TheDurbinCompound
@TheDurbinCompound 3 жыл бұрын
Flame sensor. It is a probe that tells the unit that the flame is on. Take probe out, clean with sandpaper. Reinstall.
@HomesteadJay
@HomesteadJay 5 жыл бұрын
Whats up man! Never really heard about these little buggers! Cool breakdown, Its neat to see the mechanics! Now go split some wood man :)
@TheDurbinCompound
@TheDurbinCompound 5 жыл бұрын
I sure do need to cut some wood!
@richardcoldin3831
@richardcoldin3831 4 жыл бұрын
great explanation
@servoflex5943
@servoflex5943 4 жыл бұрын
I never heard about a transformer able to give 20V DC... Is it possible to be 20V AC that is rectified to DC by a diode bridge or something? Just a question... The theory says that only AC current may be transformed...
@MasterBuilderofTruth
@MasterBuilderofTruth Жыл бұрын
Optimus prime is the only transformer that can produce dc from ac
@libertybarker7401
@libertybarker7401 5 жыл бұрын
because gas will go down to floor and gather like a pool there waiting for a spark down on the floor.
@jessetrxguy
@jessetrxguy 4 жыл бұрын
What is it when the fans running , heater ignitor stays lit up and it clicks but no heat .
@TheDurbinCompound
@TheDurbinCompound 4 жыл бұрын
Gas valve
@TheDurbinCompound
@TheDurbinCompound 4 жыл бұрын
Ensure you are given 28VAC at the gas valve. If the gas valve is actually clicking, you could be A. Out of gas (or a valve is off) OR B. You’re gas valve is not working.
@jessetrxguy
@jessetrxguy 4 жыл бұрын
@@TheDurbinCompound gas valve has been confirmed . Could it be transformer ?
@TheDurbinCompound
@TheDurbinCompound 4 жыл бұрын
Are you getting the 28VAC at the gas valve? If you are not, it could be the control board or the transformer
@jessetrxguy
@jessetrxguy 4 жыл бұрын
@@TheDurbinCompound thanks for the fast reply. We will check the transformer
@libertybarker7401
@libertybarker7401 5 жыл бұрын
there must be something that tells the gas to shut off if it fails to ignite or go s off while running. YOU DID NOT SAY ANYTHING ABOUT THAT and that is very important because that could EXPLODE & burn down your house
@TheDurbinCompound
@TheDurbinCompound 5 жыл бұрын
You’re correct. The flame sensor is a part of the system that ensures there is flame when the valve is open. The gas valve will shutoff if the flame is not sensed at the flame sensor.
@robbyclark6915
@robbyclark6915 3 жыл бұрын
This is troubleshooting not “theory of operation” 🤷🏻‍♂️
Easy Steps To Install Your Calcana Radiant Tube Heater!
6:41
The Plumbing Gurus
Рет қаралды 919
VIP ACCESS
00:47
Natan por Aí
Рет қаралды 30 МЛН
Tuna 🍣 ​⁠@patrickzeinali ​⁠@ChefRush
00:48
albert_cancook
Рет қаралды 148 МЛН
How to treat Acne💉
00:31
ISSEI / いっせい
Рет қаралды 108 МЛН
小丑女COCO的审判。#天使 #小丑 #超人不会飞
00:53
超人不会飞
Рет қаралды 16 МЛН
Comparing 6000 WATT Resistors, Infratech versus Bromic Heaters
20:45
ElectroBOOM
Рет қаралды 1,9 МЛН
Heating with Infrared Tube Heaters
7:20
Roberts Gordon
Рет қаралды 67 М.
Installed 2 Modine Hanging Radiant Shop Heaters
5:03
Anti DIY HVAC
Рет қаралды 30 М.
Generating Electric Power with my Wood Stove - Peltier Experiments
19:23
The Post Apocalyptic Inventor
Рет қаралды 396 М.
How to Install Radiant Tube Heaters
17:11
Reuben Sahlstrom
Рет қаралды 23 М.
How Does Infrared Heating Work and What Are The Benefits?
3:02
Schwank North America
Рет қаралды 178 М.
Keep Your Family Warm During A Power Outage By Installing This $5 Part
11:47
The DIY HVAC Guy
Рет қаралды 2,3 МЛН
Infrared Heating Basics (1 of 5)
11:26
Tec Tube
Рет қаралды 69 М.
VIP ACCESS
00:47
Natan por Aí
Рет қаралды 30 МЛН