Without capping to core is wrong procedure ref IS 516 part 4 2018 And correction factor formula is give F=0.11N+ 0.78 Where N is hight / diameter ratio. Graph 📈 is in old IS 516- 1959
@vivekbhoi85493 жыл бұрын
Nice video, Very informative and easy understandable 👍
@rajmaheta5330 Жыл бұрын
As per IS code individual sample Test also have minimum 75% of strength that is not matching
@rajkamalyadav6831 Жыл бұрын
Please explain this question???
@akhileshverma98232 жыл бұрын
aap bahut hi excellent kam kar rahe h sir... 🙏🙏
@HariKrishnan-wp9zp Жыл бұрын
You're very good and extrimily best explanation good job thankful to you
@rohitgarhwal27593 жыл бұрын
Very good vedeo Very informative and helpful
@mohammadfarhan3682 жыл бұрын
Good but what if there are steel bars in the core sample? what is the factor (FReinf) for steel bars...Plz
@sanketjathar95132 жыл бұрын
is this ok to have a steel in concrete core while testing and if its ok then what is based used for this by yours side. Please give us a knowledge about in brief.
@dipupal9215 Жыл бұрын
Nice video sir. Ap bahut acha samjhate h
@Fahad-4713 жыл бұрын
Very knowledgeable video Sir Thank you so much for sharing knowledge
@deepakkatkar13782 жыл бұрын
Nice explanation, superrr
@tiktikboom4226 Жыл бұрын
Core capping is necessary as per is code.. without capping core likely to fail early..
@mdangwal843 жыл бұрын
Very informative video sir
@DevenderSingh-vk6hp3 жыл бұрын
Strength of individual core shouldn't be less than 75% of fck I.e.18.75 but 2nd reading is 15.78mpa which is unacceptable
@Nanikikahaniya35 ай бұрын
Yes, But sir jabarajasti pass krne pr tule h😅
@rajasthanengineers33095 ай бұрын
Or isme cube strength ku nikale apn core ki strength dekh rahe hai na kuki m30 ki core strength 85 percent se kam na ho
@sasankasekhar97353 жыл бұрын
you just applied two correction factors..one is L/D & other is equivalent cibe strength...but there is another according to IS code & which is dia correction factor, for this it will be multiplied by 1.03 for dia more than 75 mm
@sasankasekhar97353 жыл бұрын
Also there is acceptance for avg. of three cubes 85% of Fck & individual it will be more than 75% of Fck...
@qureshiniyazahmed64922 жыл бұрын
On which page number, dia. Correction factor is mentioned..plz state.
@saiprakashraju12533 жыл бұрын
what about steel inside, you take still also, so strength had came more....in cube at the time of concrete inside no steel, kindly explain.
@rbsinghcivilengineeringaca67773 жыл бұрын
Due to the steel coming inside the core, its strength decreases because it gets a voids of core sample..
@prakashbarik463 жыл бұрын
Thank you Sir for this Video... It's so helpful
@guddukumarsah-h5n7 ай бұрын
Core cutting Kitna meter Mai karna chaiya
@AbhishekSingh-xy7yv3 жыл бұрын
Sir but according to one Clause.. individual cylindrical strength should not be less than 0.75 fck. Iska kya matlab hoga?
@rbsinghcivilengineeringaca67773 жыл бұрын
Because actual compression strength of concrete core is taken as 0.85 times of specified cylindrical strength. cylindrical strngth is given by 0.85fck As per your question :- 0.75 fck, Fck :- characteristic strength of concrete. Yani ki 0.75 × 25 ( 25 Grade of Concrete) 18.75 N/mm2 is individual strength but average strength not less than 0.85 fck 0.85 × 25 :- 21.25 N/mm2..
@rbsinghcivilengineeringaca67773 жыл бұрын
Is per is code guidelines.. 👍👍
@subratkumaranayak6232 Жыл бұрын
Pls sir is code ka nam bata dijiye
@mohdubaish4636 Жыл бұрын
516
@naveensingh92372 жыл бұрын
Clear core cutting test
@shankerkumardas70482 жыл бұрын
correction factor=2 than cylinderical strength should be= strength X correction factor i.e- 19.14 x 2
@nageshkallem3611 Жыл бұрын
U can't remove the steel how to strength achieve?
@Blogcompany_New2 жыл бұрын
Sir MORTH me likha hai ki Dia 150 mm se km nhi hona chahiye section 900 me diya hai MORTH me
@rbsinghcivilengineeringaca67772 жыл бұрын
Dear, Minimum diameter of greater of three times the maximum nominal size of the coarse aggregate or 50 mm, Diamond segmented core bit in Hilti , Size - 50 mm to 600 mm dia & length 300 mm to 2000 mm I hope cleared this issue.
@SkengineerQAQC3 жыл бұрын
Sar ismein Beria son Kitna achieve karna hai
@santoshnamdev12382 жыл бұрын
Yadi core ke andar steel aa jata h to uska strength kse minus krte h sir
@himanshupal37312 жыл бұрын
Thank you sir itni jankari dene ke liye bahut achh lga pura vedio smjhh aa gaya Sir cub ki strength persentage me kaise calculate krte hai iska ek vedio bna dijiye 🙏
@rbsinghcivilengineeringaca67772 жыл бұрын
Ok
@mohammedarif23682 жыл бұрын
Sir aap ne correction factory of reinforcement kase nikala plz batana
@deepakjain90533 жыл бұрын
Goooood important knowledge boss👍👍
@guddukumarsah-h5n7 ай бұрын
Sir Core cutting Kitna meter Mai karna chaiya
@pranavnaxane22524 жыл бұрын
Sir table mein 4th row mein 2 correction factor kese liye
@rbsinghcivilengineeringaca67774 жыл бұрын
Correction factor 2 me 1 lena hai already table me mention hai is code -516 me hai please check karo..
@Terminator6162 жыл бұрын
Should we make cube of 9.8 mm side or we compare with 150mm cube?
@Akash242744 жыл бұрын
Very nice video sir 😊😊
@hazratbilal72465 ай бұрын
How you assume the paste rate???
@pavankumaryadav49002 жыл бұрын
Thanks sir to share your best knowledge
@modassariqbal3067 күн бұрын
Sir jo core cutting krte hai to us gap ko ki material s fill krna hota hai jis structure member s core nikala hai us me what types material used to fill inside...... please make 1 video sir
@rbsinghcivilengineeringaca67777 күн бұрын
Yadi concrete ka grade M25 Jo aap ne core cutting kiya hai toa M30 grade ka concrete ya Grouting material GP2 se dear.
@modassariqbal3067 күн бұрын
@rbsinghcivilengineeringaca6777 Thanku sir
@DharmendraKumar-gq4fc2 жыл бұрын
Superb sir
@vamsireddy60323 жыл бұрын
Very good explanation sir
@harvinders182 жыл бұрын
Ssa bhaji … kya charge krte ho corecutting test ke
@samrankhan1120 Жыл бұрын
Sir sulfur capping must into both side...
@AMOLJADHAV-nu1bb4 ай бұрын
What is the 1.25 ..? And why..? Please explain..
@amarpc35323 жыл бұрын
Dear sir how plz tell me how to set 140kg/cm 2 after conversation 5.13 in/sec how to do trail error method
@shivamupadhyay30432 жыл бұрын
4:02 CORE CAPPING?
@dineshahlawat50013 жыл бұрын
For core test 516 :2017 follow up .
@rbsinghcivilengineeringaca67773 жыл бұрын
Yes...
@qamarpasha8705Ай бұрын
thumbs up brother. love from Pakistan
@CivilEngineeringbyAnkur3 жыл бұрын
Which is code detemine cube strength multiple 5/4change of
@rbsinghcivilengineeringaca67773 жыл бұрын
Is code - 516, Cylinder strength by 5/4 , Page no - 12 & table - 5.6.1 A...
@KumarP-tr8xe3 жыл бұрын
Excellent video 👍
@nemichandbabal.75334 жыл бұрын
Sir ye individual strength me fail ho rhe h as per code IS -456
@rbsinghcivilengineeringaca67774 жыл бұрын
Sir ji ish condition mein jish cube ka strength kam ya jada aati hai usko cube ko discard kar dete hai aur 2 cube ka average lete Hain..
@rbsinghcivilengineeringaca67774 жыл бұрын
2 cube ki average strength not less than 21.25 N/mm2 as per is code 85 % of Grade of concrete..& individual strengths 75%..
@nemichandbabal.75334 жыл бұрын
Bahut bahut dhanyawad sir
@Tukaram262 жыл бұрын
Very Nice information 👍👍👍
@fox67663 жыл бұрын
Any translation for this video in English?
@rbsinghcivilengineeringaca67773 жыл бұрын
No dear only for Hindi language available at KZbin channel.. sorry
@fox67663 жыл бұрын
@@rbsinghcivilengineeringaca6777 No issue Mr. Singh I will try to understand if I could 😅👍🏻 Thanks
@sachinnanavare67503 жыл бұрын
Sir make it video on rebound hammer test Calculation and report
@dineshahlawat50013 жыл бұрын
Sir not showing Correct method of testing Core test .. where showing Capping in core for testing for surface in CTM testing machine
@rbsinghcivilengineeringaca67773 жыл бұрын
Already surface preparation done before testing..
@faultychannel71063 жыл бұрын
Where are you from sir
@numanakhtar85192 жыл бұрын
Sir cylinderical strength 85% hona chahiye na cube strength ka...
@rbsinghcivilengineeringaca67772 жыл бұрын
Yes brother.. 👍
@shaikdasthagiri85173 жыл бұрын
What about shotcrete core strength achieved in 28 days core strength?
@kamranullah4780 Жыл бұрын
Dia will be check with vernier caliper
@Akash-12386 ай бұрын
1 core kitne area se cut karte hai
@shivamupadhyay30432 жыл бұрын
3:22 RATE OF LOADING140 KG/SQ CM/MIN
@pchetan2663 жыл бұрын
Sir concrete cube 28 days me 100% strength chahiye Lekin core ka 80% kyo
@rbsinghcivilengineeringaca67773 жыл бұрын
Kiyu ki cube ko conditions mea aur curing tank mein rakha jata hai jabki Core ko Foundation se nikala jata hai & test Kiya Jata hai ISH liye dear..
@rbsinghcivilengineeringaca67773 жыл бұрын
Control conditions me rakha jata hai..
@salimjavid1353 жыл бұрын
@@rbsinghcivilengineeringaca6777Sir, is there any codal reference for 80% strength (acceptable)
@rbsinghcivilengineeringaca67773 жыл бұрын
Kyunki cube control condition mein rakha Kar check karte hain aur core Foundation se nikal Kar Lete hai aur check karte hain, ISH liye as per IS code 80% required hai..
@salimjavid1353 жыл бұрын
@@rbsinghcivilengineeringaca6777 Got it, it’s clearly mentioned in IS 456 👍
@deviddas95113 жыл бұрын
Strength ko N/mm² se percentage me kese convert krte hein?
@faultychannel71063 жыл бұрын
Location
@vikramdalvi28982 жыл бұрын
Steel hai to kaise test ho jaega
@Akash242744 жыл бұрын
And very good quality of video
@ajaykumarverma73873 жыл бұрын
very nice information sir ....
@vilaspatil314810 ай бұрын
What about steel factory sir
@anootalks40773 жыл бұрын
Individual cube strength also should not fall below 75% .. but in ur case for 2nd sample it is less than 75% what about it?
@rbsinghcivilengineeringaca67773 жыл бұрын
The core individual sample acceptable limits + - 15% of average strength , As per is code - 456 & 516 , but core average strength not less than 85% of Grade of Concrete, individual Strength less than 85 % acceptable but average strength not less than 85%.. as per is code guidelines..
@anootalks40773 жыл бұрын
@@rbsinghcivilengineeringaca6777 ok..so individual cube strength should not be less than 15% ? If it's less than 15% and overall average strength is 85% also then we have to reject it?
@rbsinghcivilengineeringaca67773 жыл бұрын
@@anootalks4077 Yes , If the strength of any one of the three cubes is much more or less than the average strength, then it is discarded and the strength of the two cubes is check the average strength for , And the strength of individual both cubes is + - 15% of average strength and average strength not less than 85 % of the grade of the Concrete .
@rbsinghcivilengineeringaca67773 жыл бұрын
@@anootalks4077 And if the parameters of the cube set do not meet the IS code limits, this Cube set is rejected.
@anootalks40773 жыл бұрын
@@rbsinghcivilengineeringaca6777 thanku very much for ur reply
@NikitaSharan-g3b8 ай бұрын
Correction factor samjh nahi aaya
@onlytanmay2 жыл бұрын
Spreading somewhat little misinformation as per my book , because for L/D ratio of greater than 1.75 we don't have to take correction factor
@snarasimha843 жыл бұрын
Sir core ka caping karna tha
@mustakimansari57562 жыл бұрын
Very good 👍
@mohammedarif23682 жыл бұрын
How to tak volume and bulk dentist
@onlytanmay2 жыл бұрын
πr²h is volume
@onlytanmay2 жыл бұрын
And ρ=Weight Measured/Volume
@SHAHBAZ7466 Жыл бұрын
Caping ni ki es ko
@harishmalladihalli45883 жыл бұрын
Sooper info dhanyavaad.
@bijanmaity34592 жыл бұрын
Sir this result is not appropriate for acceptation condition, because three cube result not under 15%.
@rohits12882 жыл бұрын
Sir where are you from & In which company do you work ?
@mscivilconstruction23383 жыл бұрын
sir agar steel a jaye core main to kya correction factor lagega
@rbsinghcivilengineeringaca67773 жыл бұрын
Yes
@mscivilconstruction23383 жыл бұрын
konsa factor lagna hai sir as per is code
@jyotirmoy_43 Жыл бұрын
Thank you sir . Want some more video ❤
@yashbogawar35574 жыл бұрын
Sir, one request to you, Please mention the IS CODE NO. also in video.
@rbsinghcivilengineeringaca67774 жыл бұрын
Ok , IS code - 516 for lab testing..
@rbsinghcivilengineeringaca67774 жыл бұрын
Dear good morning.. Is code already mention hai video & notebook mein bhi mention..
@yashbogawar35574 жыл бұрын
@@rbsinghcivilengineeringaca6777 thank you.
@prabhatmishra71072 жыл бұрын
Sir IS 516 me kon sa part me h ....Plz reply
@jocks5176 Жыл бұрын
i see your video and easy understable but you forget about tell individual strenth, i see in your video the 2nd sample is fail 15. something so you forget tell about individual calculation. thankyou sir, Im a QA/Qc Engg.
@expose.india14303 жыл бұрын
How to convert core average into percentage
@Blogcompany_New3 жыл бұрын
Strength me variation bhut aa rha hai.. 5% tk allow hai
@anilsingh84304 жыл бұрын
Very nice video
@souravmukherjee19923 жыл бұрын
Sir I just a request to you, please detail discuss about 516 and accepance criteria
@rbsinghcivilengineeringaca67773 жыл бұрын
Ok, sure brother 👍👍
@nishant.centkanes3 жыл бұрын
What about variation of + - 15% of individual w.r.t average
@rbsinghcivilengineeringaca67773 жыл бұрын
Dear cube ya Core , Variation +-15% hi hai but Haam ne 03 Set core liya tha is liye 3 set core me acceptable limit,, jaise ki aapane note Sheet mein Dekha hoga.. Aur yadi individual ki baat karte Hain to not acceptable..
@rbsinghcivilengineeringaca67773 жыл бұрын
Ok dear aur koi question???..
@AHoney-xl9ux3 жыл бұрын
Dear, very nice info. But what is factor of concrete cube 15×15×15 cm during compressive test. Because ratio 15/15 = 1. Guide at this point of cube test.
@manishsahu22529 ай бұрын
sir as per is code compressive strength should not differ more than +,- 15% but aapke result mai toh 35% tak excceed kar rha hai kaise?
@guddukumarsah-h5n7 ай бұрын
Sir core cutting Kitna meter Mai karna chaiya
@KISHORKUMAR-mm7bg3 жыл бұрын
Excellent sir thank you sir
@falkebrothersatulfalke9281 Жыл бұрын
Thanks 😊
@jitendrashah2058 ай бұрын
Strength calculation video too fast.cant understand properly.
@sankartavar18674 жыл бұрын
Good video
@feelthegame50742 жыл бұрын
Thank you very much sir....
@DharmGoud3 ай бұрын
Correction factor 2 hona chahiye
@miniyoutuber6662 жыл бұрын
sir core test ka details vedio as per is code banyaye please
@utpalbiswas62923 жыл бұрын
Nice
@Anandcomdey78 Жыл бұрын
Thanks sir ji
@AHoney-xl9ux3 жыл бұрын
Please make video for compressive strength of concrete block.
@Vishalkumar-nb5en3 жыл бұрын
Sir agar aap new youth ko help karna chahte hai to apna number dijiye please
@rbsinghcivilengineeringaca67773 жыл бұрын
My dear friend, we are 24 hours ready to help you as much as we can.🙏🙏
@SkengineerQAQC3 жыл бұрын
Sir isme variation limit Kitna acceptable hai.which Coad.
@rbsinghcivilengineeringaca67773 жыл бұрын
@@SkengineerQAQC ???
@rbsinghcivilengineeringaca67773 жыл бұрын
@@SkengineerQAQC Question clear Nahi hai bhai..
@rakeshsahu37783 жыл бұрын
Area calculations wrong
@jawaharp89013 жыл бұрын
Core test all test fail next what do demolish element
@rbsinghcivilengineeringaca67773 жыл бұрын
1) rebound hammer test 2) ultrasonic pulse velocity test 3) discussion to designer 4) jacketing and extra support provided 4) calculation the load All parameters are not meeted, So demolish the building..