Recirculation Control

  Рет қаралды 78,445

Navien Inc.

Navien Inc.

Күн бұрын

Пікірлер: 35
@JohnWells-lm5fq
@JohnWells-lm5fq Жыл бұрын
This was an exact replacement for the old one that lasted about 10 years. kzbin.infoUgkx7yWIKcrbA9KMHkGSfcgxW2lsjHT6B8Sh The top of my mitigation tube by my roofline was just a 90 elbow which allowed too much debris to fall down into the fan, eventually ruining it. Without this issue, I bet it would have kept running another 10 years. When I replaced this fan, I added an extra elbow joint so the top tube now it does a 180, which should solve that problem. The radon guys around here wanted to charge me a $300 diagnostic fee, then parts/labor (probably close to $600 total). I installed this all by myself in about an hour for the cost of the fan; it would probably be even easier/faster with two people. FYI the manufacturer's warranty greatly differs depending on whether you install it yourself (1 yr warranty) or have a licensed installer do it (10 yrs).
@SENIORSTYLE
@SENIORSTYLE 25 күн бұрын
The navien hot is hot but the honeywell heater box is cold along with above brass pipe. How to turn that on as when I called navien no help because I'm the home owner
@arjun1910
@arjun1910 Жыл бұрын
Installed a new 240A2 with navicirc valve at distant sink. What is the settings on the machine internal vs external circulation? Right now there is no pipe entering the recirculating port on the water heater. Please help. Thanks
@JustinDD
@JustinDD 2 жыл бұрын
just wondering if running the recirculation all the time is a concern for the pump or system? Only reason I ask is that was a option shown on the menu of your video but the speaker didn't speak to it
@brycemcguire9477
@brycemcguire9477 2 жыл бұрын
Constant recirculation can erode copper water piping over time, causing pinhole leaks. For newer houses with all PEX water piping, the risk and electricity usage is pretty minimal.
@elijah7939
@elijah7939 Жыл бұрын
This navien model has different recirculation settings not just constant recirulcation. It has a smart use setting
@shreyasdube
@shreyasdube Жыл бұрын
So, for a NPE-A, for an external recirculation retrofit, I just need that recirculation valve?
@joker-if4gu
@joker-if4gu Жыл бұрын
same question i have , is the cold water line in the existing house being used as return right? by connecting that black 4 way vavle on the last faucet
@kchiem
@kchiem Жыл бұрын
How do I configure the HotButton recirculation to recirculate as long as the other modes when they kick on? The other modes recirculate until the return temp is 9F less than the hot outlet set temp, but the HotButton recirculates only until the return reaches 100F. Worst, it doesn't do this by default either, as the default settings have it running only ~10s; the farthest fixture setting has to be changed from the default of 30 ft to some high unrealistic value (200+ ft) in order for the HotButton recirculation to run long enough for the return temp to rise that high. Whatever formula it's using here to calculate runtime, it's broken, as it doesn't reflect reality. Edit: Found the solution to the HotButton issue. On my A2 model, turn on dipswitch 2 on the HotButton PCB to disable Energy Savings Mode, and it'll recirc like the other recirc modes. I called Navien Support, and they wouldn't tell me how. Had to google and do a bit of reading to find it. Navien, maybe you guys can also explain why you won't tell me how to configure my equipment to work the way other modes already work. Pretty infuriating how useless support is.
@nicholasali2182
@nicholasali2182 Жыл бұрын
My unit is running cold water from time to time. It's brand new. WASN'T an issue a week ago. Should I set it to recirculation mode?
@stephenbonner323
@stephenbonner323 11 ай бұрын
My NPE-A2 ran perfectly fine using the recirculating system until the end of December. Unit was installed in the late fall of 2022. Now, in either recirculation mode, it no long works, pumping only at a minimum rate, taking 5 minutes or more to get water temp to the set 125 degree temperature. The Navien recirculating valve is installed by our dealership that sold us the tankless. They cannot figure out what the problem is. They claim the pump is working properly, and it does until they leave my home. I'm getting really frustrated and need help. No one has offered to replace the pump or the control board to see if that could be a problem. It is still under warranty. Please help me.
@rickyswanson8547
@rickyswanson8547 11 ай бұрын
Call the navien help line and explain your situation
@doombuggyc6628
@doombuggyc6628 9 ай бұрын
It can be the motherboard
@tkstrike9477
@tkstrike9477 Жыл бұрын
Trying to find a solution for the NPE-240a with external recirculation line. The unit was installed over 2 years ago, and dip switch setting is Sw1 & 2 are both on for Intelligent mode. Over the past 6 months, when the recirculation pump turns on, I get pipe tapping noise (like air in line), and are trying to figure out how to fix it. The unit was installed with all PEX lines and insulated. Additionally I wanted to ask if it's okay to lower the pump run time to 10 minutes vs. the default 20 minutes. Thanks in advance for your support.
@cadamham
@cadamham 3 ай бұрын
Dilemma: waste water or waste natural gas?
@darrentoth7165
@darrentoth7165 Жыл бұрын
I want to do a recirc return line (210A2) is a expansion tank required? Also, at the end of the loop, do I need a normal three way fitting ( from tank, to sink and return to tank) or a swing valve? Thanks!!
@N6J6R6
@N6J6R6 Жыл бұрын
Do you folks have a video on how to set the recirculation to intelligent? I just got this hot water heater and haven't had a chance to play with the menu yet. Also, how do I select internal or external?
@jbyers3005
@jbyers3005 10 ай бұрын
Those are all changeable in the settings menu. Find the recirc settings and go through all of them. You will be able to address all of those.
@jaisvikt
@jaisvikt Жыл бұрын
My timer only offers a scheduled recirc and as we are not robots on a fixed schedule, an "instant" on capability would've been nice. Are there options?
@marksplace
@marksplace Жыл бұрын
If I use it in external circulation mode. Would it hurt the unit if I control the pump seperate from the unit. Would Turing the pump off cause it to over heat seeings that water movement would stop?
@marksplace
@marksplace Жыл бұрын
Basically I want to use an aquastat to control the pump without the machines knowledge. I know on some boilers it you turn the pump off while it's on will cause it to shake around due to the water boiling in the heat exchanger without any movement. Thanks
@joker-if4gu
@joker-if4gu Жыл бұрын
how is the hot water being returned in that loop? is there a dedicated 3rd pipe dedicated that needs to be tied in into faucets? or does it use the cold water line as return .
@Countrysidehvacservice
@Countrysidehvacservice Жыл бұрын
I believe the navien recirc pump utilizes the cold line as a return
@Canvasone63
@Canvasone63 Жыл бұрын
Can you use multiple crossovers in a recirculation system?
@plagueless9829
@plagueless9829 10 ай бұрын
No it will take the shortest loop
@dewalt10
@dewalt10 2 жыл бұрын
I did the hot water outlet in 1" pex and the return reciruclation pipe in 1" is that going to be a problem ? I have the NPE 240A2
@brycemcguire9477
@brycemcguire9477 2 жыл бұрын
Unless you have a recirc pipe that is several hundred feet in length, 1" is very oversized. This could cause laminar flow, temperature fluctuations, and unnecessary work for your recirc pump.
@DLiver2002
@DLiver2002 Жыл бұрын
Remote Screen on this video is almost as difficult to read as the remote I have. No way to adjust the backlight.
@Encrypt_ed
@Encrypt_ed Жыл бұрын
What should you do when you have an external unit & when you plug in the recirculating pump it’s stays running and never shuts down. I added the smart plug as well and it’s shuts off but it’ll automatically turns on & off with no by itself with no water calling in the house. When it runs it stays on for awhile before it shuts off
@jbyers3005
@jbyers3005 10 ай бұрын
With an external pump it is controlled by the outlet it’s plugged into. The easiest way to address it is a timer that plugs into the outlet, and the pump plugs into the timer. Sounds like you got something similar. You should be able to turn it on or off in 15 to 30 minute increments.
@mrniusi11
@mrniusi11 2 жыл бұрын
Does this save energy overall?
@longrange1114
@longrange1114 2 жыл бұрын
compared to a tank type water heater yes. Also saves the amount of water that is wasted while you wait for it to get hot.
@onlyme972
@onlyme972 8 ай бұрын
I just installed a Jnod electric combi that has a built in heater for instant hot water.
@ponchosancho7710
@ponchosancho7710 10 күн бұрын
One day hopefully one of you tankless engineers will make a adjustible cross over valve 95°f-105°f isnt hot enough for everyone. Maybe just have a hotter crossover for purchase at 115-120f
@wallacegrommet3479
@wallacegrommet3479 Жыл бұрын
Same old large corporation video instructions suck. Manuel useless information in regards to recirc Get with it people. Likley, lots of returns.
3 Things They Don’t Tell You About Tankless
5:56
Matt Risinger
Рет қаралды 2,7 МЛН
Navien NaviCirc Recirculation Valve
3:05
Navien Inc.
Рет қаралды 61 М.
Каха и дочка
00:28
К-Media
Рет қаралды 3,4 МЛН
BAYGUYSTAN | 1 СЕРИЯ | bayGUYS
36:55
bayGUYS
Рет қаралды 1,9 МЛН
小丑女COCO的审判。#天使 #小丑 #超人不会飞
00:53
超人不会飞
Рет қаралды 16 МЛН
Hot Water Recirculation System
6:27
MEP Academy
Рет қаралды 72 М.
Basic Maintenance of a Navien NPE A tankless water heater
4:19
Navien 30022965A Navi circ valve
21:36
That Tankless Guy
Рет қаралды 3,9 М.
The different models of Navien tankless heaters and what they do.
28:27
That Tankless Guy
Рет қаралды 2,1 М.
HVAC Companies HATE That You Can Do This Yourself.
25:51
The DIY HVAC Guy
Рет қаралды 610 М.
NPE 2 Condensing Tankless Water Heaters
5:40
Navien Inc.
Рет қаралды 61 М.