A reference video on how to install and troubleshoot Red Lion 1/2 hp shallow well pump RJS-50-PREM.
* Change voltage switch from 230 to 115 (ignore the mismatched color cables, go by positioning)
* Make sure tank pressure is 28psi
* Prime the pump and release air through air valve
* Use teflon tape and supplied plugs for watertight fit
* Connect power cable correctly
* Call their tech support - they're knowledgeable and helpful people