Queries solved:
1. What is star Delta starter.
2. What is star Delta starting.
3. How to select relay for star Delta Starter.
4. Relay rating Selection.
5. Relay Selection guide.
6. Star Delta Starter relay Selection.
Hello Friends in this video we discussed about how to select relay for star Delta Starter in the simplest way possible.
About Channel:
In this Channel we cover the topics like Machines, Power System and General Electrical in the simplest way possible.
#StarDelta
#Relay
Kindly subscribe.
Thank you.

Пікірлер: 132
@balkumarchauhan7756
@balkumarchauhan7756 Жыл бұрын
Pichhle video me star connections motor adhik current leti hai delta connections ke dikhaya hai sir Aur yha pr Star 33% aur delta 58% current leti hai full load current ke kaise
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi Жыл бұрын
Aapka confusion phase current or line current ka hai.
@Aaru-Angel
@Aaru-Angel 3 жыл бұрын
90 kw motor sir 156 amp legi....ok
@sidharthpatil8416
@sidharthpatil8416 3 жыл бұрын
3phase / 1 phase motor ka winding restiance kitana hona chahiye , short winding kase pata kare, multimeter ke kaise check kare..... please support
@itielectricalclasses201
@itielectricalclasses201 Жыл бұрын
सर आपने अपनी वीडियो में 90 किलो वाट का मोटर का फूल लोड करंट 180 amp बताया है Aap Aisa Kyun Bata rahe hain
@itielectricalclasses201
@itielectricalclasses201 Жыл бұрын
90 kw motor ka FLC 180 kaise ho jayega sabhi log batao . Ek video kuchh aur hote Hain aur dusri video mein kuchh aur bolate. Kripya gumrah na Karen😅
@sumits_shetty
@sumits_shetty 2 ай бұрын
Ap 58% of FLC bol rahe ho. Ye obviously Iph hoga na? Over load relay Phase me lagaya to hi ye apply hoga. Incase line me over load lagaya to full load ampere set Krna hoga
@jayendraahir1312
@jayendraahir1312 2 жыл бұрын
Sir 90 kw motor ka fhul load curent 158 amp he .motor runinig continou to rely setings delta current me hi set hogi 158 amp
@rajnipatel445
@rajnipatel445 Ай бұрын
Good morning sir stardalta motor relay line current me Laguna better he ki phes current me better he
@hasmukhpiprottar17
@hasmukhpiprottar17 2 жыл бұрын
sir mere pas 75kw ka motar he or ishame main mpcb 400A ka or sir over load relay face current me laga or muje ae motar daily start stop karna he sir inka relay seting 58% 74.5A pe rakhata hu to starting mehi motar over load ho jata he
@thakornj9493
@thakornj9493 Ай бұрын
Star delta me 6 wire hote he relay main contactor me lagta he to current to 2 bhag me bat jaata he to kya kare....50A motor ka rated current he star delta connection or relay main cont.me laga he 50A tak set karna ho to 25 A par set kare ya 50 A..????
@pawanrathod1408
@pawanrathod1408 3 жыл бұрын
Sir continuity kya hota hai electrical mein batayiyena please Mein ek biginar huu please Sir batayiyena
@Hemanth2787
@Hemanth2787 4 жыл бұрын
Is fullload current is same in star conncetd motor and delta connected motor for same kw rating?
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 4 жыл бұрын
Yes..
@abhijitdutta244
@abhijitdutta244 4 жыл бұрын
Sir je please RMU ar alternator ka ak alag si video banaia 🙏 🙏 🙏🙏
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 4 жыл бұрын
Okay Abhijit...
@PappuSingh-em2ve
@PappuSingh-em2ve 2 жыл бұрын
Please tell me in star delta starter olr setting will be different or not and will be then how much for star and delta
@AshisNayak-cs5hc
@AshisNayak-cs5hc 4 ай бұрын
If star delta starter power on without any load then what happen?
@d.kkumar4186
@d.kkumar4186 3 жыл бұрын
Mpcb 400amp ki sating kse kre
@ahirvijaykumar7576
@ahirvijaykumar7576 2 жыл бұрын
Sir star delta starter se chalne Vali motor ka flc kese nikale
@tikendraverma863
@tikendraverma863 3 жыл бұрын
Sir ब्लैकबोर्ड में समझाओ ना
@skdoniya2003
@skdoniya2003 2 жыл бұрын
Sir 2pole or 4pole olr setting same hai?
@suryakantyadav128
@suryakantyadav128 4 жыл бұрын
Sir mere Ghar me 7.5 kw ka motor hai Jo ki manul star Delta starter say chal rha tha ,per kuch deno say usme proble aa rha tha ,contect melt ho gye the aor coil bhi hold nhi ho rha tha,to Maine usme mody fykr diya hu ,uske andar 32Amp ka MCB ,,32Amp ka contector aor 20Amp max range ka OLR really install kr ke DOL STARTE me convert kr diya hu ,relay setting 13 Amp me kiya hu ,Kyo ki sir Ghar me mai any time rhta nhi hu aor baaki log non technical hai setting Kam krne per baar baar trip hoga ,es say agar Ghar ke log rest krne jyeng to electrical hazard ke chanses bad jyenge,, to sir Maine sahi Kiya ya galat (selection of breakers/Relay
@ravishankarsharma5315
@ravishankarsharma5315 2 жыл бұрын
For 20 HP, 3 Phase Induction Motor of Submersible Pump, which starter we have to select - 20 HP or 22.5 HP and what will be selection criteria & How ? Pls reply.
@vinodbareth4344
@vinodbareth4344 4 жыл бұрын
Delta full load current 58% kaise hits hai
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 4 жыл бұрын
In delta IL=root 3 x Iph hota hai. So, Iph = 1/1.732= 57.7 In Industries we normally take 58 for Calculation
@dhaniraikwar7455
@dhaniraikwar7455 3 жыл бұрын
@@electricalwithabhishekjoshi sir d.o.l starter me bhi to motor runining condition me delta me conect rahti he ....or star delta starter me bhi runing me motor delta conect hoti he ....phir kyo?...80% or 58%....pls expln sir ji
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 3 жыл бұрын
Video banata hu
@siyaramrathore6722
@siyaramrathore6722 2 жыл бұрын
Sir agar normal motor ko delta me connection karte hain to FLC Ka 80% use karte hain Aur Star to Delta me 58 % hi kyu Kyuki Delta ka formula Dono condition me same hi rahta hai As Line Current = √3 phase current
@sureshkumar-fp8bl
@sureshkumar-fp8bl 2 жыл бұрын
Sir,not add servise factor.
@suryakantyadav128
@suryakantyadav128 3 жыл бұрын
Sir lag rha hai ye Corona job kha jyegi
@cricguruinfo1938
@cricguruinfo1938 3 жыл бұрын
Sir plc ke uper video banaye
@Adren0.
@Adren0. Жыл бұрын
What if in DOL starter motor winding is delta in that case also we set O/L to 58% of Full load current
@badgujarminesh6776
@badgujarminesh6776 Жыл бұрын
Where is 58% has come from..I mean how we made the calculation of 58%
@kavyasingh815
@kavyasingh815 Жыл бұрын
Line current=√3 phase current
@satishvarma3346
@satishvarma3346 3 жыл бұрын
In Star delta star timer setting for star to deta change over time plzz
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 3 жыл бұрын
12 sec..
@gunvantgotmare7515
@gunvantgotmare7515 8 ай бұрын
Kw se kitaneka relay lagasakate
@pawansoni1165
@pawansoni1165 2 жыл бұрын
Sir Star ki condition me bhi bataiye and DOL Starter ke Case me bhi suggest kijiye
@SandeepSharma-xy3oj
@SandeepSharma-xy3oj 4 жыл бұрын
Thanks sir, In your video say drow current in stat only 33% how? Plz explain me.
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 4 жыл бұрын
33% in star not in start..
@SandeepSharma-xy3oj
@SandeepSharma-xy3oj 4 жыл бұрын
@@electricalwithabhishekjoshi ok thanks
@d.kkumar4186
@d.kkumar4186 3 жыл бұрын
3RB2283-4AA1 RELAY PR AK VIDEO BNAO SIR
@vinun9307
@vinun9307 3 жыл бұрын
I love your all electric videos. Very usefull Plz muze apke electric groip me add kardo
@mitubarik3361
@mitubarik3361 3 жыл бұрын
But sir there are 1OLR in star delta srater how i can change OLR seeting in star 33% and delta 58%
@Hemanth2787
@Hemanth2787 4 жыл бұрын
.what will be the line current of 5kw motor if it s conntected in star nd what will be the current in delta if tha same motor s connted and connection are changed
@Hemanth2787
@Hemanth2787 4 жыл бұрын
Pls
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 4 жыл бұрын
Hemant I will release this video today evening..
@kuldeepcheem98
@kuldeepcheem98 3 ай бұрын
Thanks
@ankitkd6003
@ankitkd6003 3 жыл бұрын
Pl suggest how to set time range of star delta timer
@vishalpatel-fe1yd
@vishalpatel-fe1yd 4 жыл бұрын
Sir 90kw ki motor ka current kam hota he na 160 amp something
@SanjayChauhan-dz4cw
@SanjayChauhan-dz4cw 4 жыл бұрын
For star delta starter thermal over load relay range selection is 80% for min range and 120% for max range formula applied ?
@shahidqadri4340
@shahidqadri4340 3 жыл бұрын
Abhishek, Kindly make a video on star to delta shifting time as per motor capacity.
@mddanish-zk7xn
@mddanish-zk7xn 17 күн бұрын
Thanks sir
@BrajeshPathak-e8i
@BrajeshPathak-e8i 4 ай бұрын
Thanks❤❤❤ sir
@randheerpatel7414
@randheerpatel7414 Жыл бұрын
Thanks bro
@ShaoibKhanDiaries
@ShaoibKhanDiaries Ай бұрын
Very nice
@RajeevSainielectricals
@RajeevSainielectricals 3 жыл бұрын
Very good f sir I'm ur fan...
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 3 жыл бұрын
Thank you Rajeev...🙏
@alijee4876
@alijee4876 2 жыл бұрын
Good Sir i appreciate from Pakistan
@hiteshwarsingh9685
@hiteshwarsingh9685 4 жыл бұрын
Sir star delta starter me really men contrecror ke output me laga hota hai usme moter ke 3 terminal, baki 3 terminal delta contrecror me to Mera confusion ye hai ampiar kese check hoga moter ka
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 4 жыл бұрын
Hiteshwar, motor mein jo 6 lead ja rahe hai (3 main contactor se aur 3 delta contactor se) usme current check karo..
@hiteshwarsingh9685
@hiteshwarsingh9685 4 жыл бұрын
@@electricalwithabhishekjoshi sir Mera cunfusin ye hai really se 3 terminal baki 3 delta se to really actual current sens kese Karega kya really Ka position tik hai ya mccb brekar ke bad olr really lagana chahiye olr really Ka sahi position kya hona chahiye
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 4 жыл бұрын
Hiteshwar relay ka position sahi hai... 6 leads mein same current hi flow hota hai..
@hiteshwarsingh9685
@hiteshwarsingh9685 4 жыл бұрын
@@electricalwithabhishekjoshi really 90amp me set hoga to really ke output R our delta contrecror ke output R phase me kitne Amp par trip hoga us time. dono R phase me Kitna amper bahega
@VinaySingh-qy4ip
@VinaySingh-qy4ip 2 ай бұрын
Nice
@kamtaprasad784
@kamtaprasad784 4 жыл бұрын
Fantastic video 👌👌 Thanks sir 🙏
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 4 жыл бұрын
Most welcome KK..
@manojkhilar4540
@manojkhilar4540 3 жыл бұрын
sir star delta starter phase relay setting,please clearly
@rashmiranjandalai9054
@rashmiranjandalai9054 3 жыл бұрын
Sir kindly reply me what is iph
@CulturalyCurious
@CulturalyCurious 4 жыл бұрын
Awesome video 👍👍👍
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 4 жыл бұрын
Thank you..🙂
@Rajeevkumar-ri7oz
@Rajeevkumar-ri7oz 3 жыл бұрын
Nice information sir ji
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 3 жыл бұрын
Thank you Rajeev..
@d.kkumar4186
@d.kkumar4186 4 жыл бұрын
Nice video sir
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 4 жыл бұрын
Thank you..
@ErUttamGupta
@ErUttamGupta 2 жыл бұрын
BUT if we used DMPR or OLR just after the MCCB then wiring the star , delta and main contactor tab to 80% rakhna parega na sir
@kavyasingh815
@kavyasingh815 Жыл бұрын
Yes
@ErUttamGupta
@ErUttamGupta Жыл бұрын
@@kavyasingh815 Are u experienced or fresher ?
@kavyasingh815
@kavyasingh815 Жыл бұрын
I have one year experience I saw a video on these topic electrical dost channel
@ErUttamGupta
@ErUttamGupta Жыл бұрын
@@kavyasingh815 Oh , i also have 4 years of experience.
@kavyasingh815
@kavyasingh815 Жыл бұрын
Great
@mbkelectricals6649
@mbkelectricals6649 4 жыл бұрын
Great work sir 👍👍👍
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 4 жыл бұрын
Thank you Faisal..
@NazrulIslam85
@NazrulIslam85 3 жыл бұрын
Great great great great
@hemantkumarthakare9563
@hemantkumarthakare9563 3 жыл бұрын
Thank u sir
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 3 жыл бұрын
Most welcome Hemant..
@sanjayajena6711
@sanjayajena6711 3 жыл бұрын
Thank you
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 3 жыл бұрын
Most welcome Sanjaya...
@suryakantyadav128
@suryakantyadav128 3 жыл бұрын
Nice explation sir,
@iftikharahmed1670
@iftikharahmed1670 3 жыл бұрын
Good one thank u so much
@anildarri2185
@anildarri2185 2 жыл бұрын
Nice explain sir
@rashmiranjandalai9054
@rashmiranjandalai9054 3 жыл бұрын
Iph kya he
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 3 жыл бұрын
Phase current
@suvendukar7947
@suvendukar7947 4 жыл бұрын
Thanks Abhishek
@AlishaKhan-ld2qt
@AlishaKhan-ld2qt 2 жыл бұрын
Nice sir
@chandrakantapradhan4963
@chandrakantapradhan4963 Жыл бұрын
Awesome 👍
@niteshkumar1738
@niteshkumar1738 4 жыл бұрын
How to calculate Amp. in star delta drive , as it have 6 wire connection ?
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 4 жыл бұрын
Nitesh, are you talking about Full load current??
@niteshkumar1738
@niteshkumar1738 4 жыл бұрын
@@electricalwithabhishekjoshi Yes Sir
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 4 жыл бұрын
Nitesh Maine star Delta starter ka full load current pe video banaya hai. Aap wo dekh sakte hai.
@niteshkumar1738
@niteshkumar1738 4 жыл бұрын
@@electricalwithabhishekjoshi sir i already watch that video,but matter is not clear to me. Suppose 250kw motor is running with star delta and i have to take full load current with "tounge tester ", how i will calculate full load , as star delta have 6 nos. of lead ?
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 4 жыл бұрын
Nitesh the current you take with fluke meter is running current not a full load current. All the 6 lead draw same amount of current. But that current is a running current.
@mayanksammal4378
@mayanksammal4378 3 жыл бұрын
Thanku sir ♥️
@Electricalengineering-sx1yq
@Electricalengineering-sx1yq 3 жыл бұрын
Good video
@dilipsahusahu680
@dilipsahusahu680 4 жыл бұрын
Very nice explain sir aapka video acch Lagta hai
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 4 жыл бұрын
Thank you Dilip..🙏
@samvedna22
@samvedna22 4 жыл бұрын
Awesome videoo
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 4 жыл бұрын
Thank you Samvedna..
@thanikanikaran
@thanikanikaran 3 жыл бұрын
Nice mes 👍
@travelwithsaikumar
@travelwithsaikumar 4 жыл бұрын
Why only 58%
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 4 жыл бұрын
1/1.732 ka percent nikalo.. its 57.7% Phase current is 1/1.732 time of line current. Video mein bataya hai.
@SandeepSharma-xy3oj
@SandeepSharma-xy3oj 4 жыл бұрын
Sir, Why take only 33% in star. When voltage reduce the current increase.? Practically we see when motor starting time current take more the full load. Plz reply..
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 4 жыл бұрын
Sandeep, it is true that when voltage increases current decreases and vice versa. I think you have doubts that voltage will decrease in star then how current will decrease as they are inversely proportional. Right? But Sandeep, you are comparing phase voltage with line current. In star, phase voltage will reduce not the line voltage. Hope you got the point..
@SandeepSharma-xy3oj
@SandeepSharma-xy3oj 4 жыл бұрын
@@electricalwithabhishekjoshi thanks
@sumanghosh3298
@sumanghosh3298 4 жыл бұрын
Vai 90 kw motor me FLC current 180amp? Kaise?
@satyamjaiswal5561
@satyamjaiswal5561 3 жыл бұрын
90÷.746=121hp then, 121 *1.5= 180 amps
@sumanghosh3298
@sumanghosh3298 3 жыл бұрын
@@satyamjaiswal5561 vai not 1.5 tum is formula ko savi motor me apply nahi kar sakte . Kuki motor ka PF or uski efficiency vi depends karti he us motor ki FLC ke upar.
@sumanghosh3298
@sumanghosh3298 3 жыл бұрын
Max current I =power/ √3×V×cos¢×effeciency Tum total power of motor / 500 To 550 se devide karoge to near about result milega.
@sumanghosh3298
@sumanghosh3298 3 жыл бұрын
@@satyamjaiswal5561 90KW =90000watt 90000÷500= 164 amps
@itielectricalclasses201
@itielectricalclasses201 Жыл бұрын
Ye chutiya banate hain
@tegbahadur6790
@tegbahadur6790 3 жыл бұрын
Good knowledge thank you sir
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 3 жыл бұрын
Most welcome Teg Bahadur.
@electricalwithabhishekjoshi
@electricalwithabhishekjoshi 3 жыл бұрын
Also watch playlist for videos related to Drawing, Calculation, Motor, Transformer, Power Factor Correction and many more.
@babasahebgondhali7719
@babasahebgondhali7719 4 жыл бұрын
Sir 90kw motor ka full load current 160amp hotahe
@ZYXYZLF
@ZYXYZLF Жыл бұрын
It's depend on PF and Efficiency
Interview Question on Star Delta Starter |Star Delta Starter Calculation | Hindi
7:33
Electrical With Abhishek Joshi
Рет қаралды 75 М.
Why Star Delta Starter used in Motor
14:25
Deepakkumar Yadav
Рет қаралды 710 М.
when you have plan B 😂
00:11
Andrey Grechka
Рет қаралды 67 МЛН
Please Help This Poor Boy 🙏
00:40
Alan Chikin Chow
Рет қаралды 23 МЛН
How to set over load Relay
12:14
Building Sanchalan
Рет қаралды 10 М.
Which Relay Used In Vcb | Vcb mein kitne Relay lage hote hai
8:39
Why we Use 3ph? Why Not 4ph, 5ph??| Why Transmission done with 3ph| 1ph vs 3ph System
9:01
Electrical With Abhishek Joshi
Рет қаралды 27 М.
DOL starter switchgear rating selection in details .
15:20
Electrical Design & Estimation
Рет қаралды 52 М.