Reorient the Coordinate System of a part in NX 9 to the normal view (F8)

  Рет қаралды 14,647

Darova ME

Darova ME

Күн бұрын

Пікірлер: 12
@finnvonwesternhagen3542
@finnvonwesternhagen3542 5 жыл бұрын
omgosh, in the end it's so simple. Thank you so much, you saved my day! I had an assembly were all parts were somehow misaligned to the absolute CSYS, although i built it all myself in NX. The video could be more compact though.
@darovame9372
@darovame9372 5 жыл бұрын
Thanks for the observation, I will take it into account for future videos.
@jasonborn1387
@jasonborn1387 Жыл бұрын
Thank you very much indeed!!
@rohitjagdale7352
@rohitjagdale7352 3 жыл бұрын
Thank you so much!
@Rovins85
@Rovins85 4 жыл бұрын
Hi, do you know a way to move a component to the origin of the assembly? I am not able to use csys to csys move tool because I can not visualize the coordinate system of the component within the assembly. There is a way to visualize datum in an assembly? Thanks
@darovame9372
@darovame9372 4 жыл бұрын
Maybe this video can help you: kzbin.info/www/bejne/i16bYmx5eMafoNk
@Rovins85
@Rovins85 4 жыл бұрын
@@darovame9372 Thank you for the link, but in my case, my component has been moved around from the origin of the assembly and I need to relocate it back again, but using contraints is not possible, so I think by doing a csys to csys move would be an easy solution, but without modifying the component internally like in the video you linked. Is possible to do that? because I can not see in the assy the coordinate system to take as a reference for the move, or there is another way? Thanks in advance.
@darovame9372
@darovame9372 4 жыл бұрын
@@Rovins85 The components are bodies or parts?
@darovame9372
@darovame9372 4 жыл бұрын
Because if you want to move bodies, only with the option Traslate ctrl + T you can move your bodies; constrains is used only for parts.
@Rovins85
@Rovins85 4 жыл бұрын
@@darovame9372 Hi, I finally discovered what was wrong with my issue , I only hat to replace the reference set of the component to "Entire part".(right button on the component) By default, I don't why, the component was set to MODEL, so that I could not see any datum. By the way, thank you!
@technocraftengineeringsolu7634
@technocraftengineeringsolu7634 3 жыл бұрын
thanks for making....
@gangadhar.p9002
@gangadhar.p9002 4 жыл бұрын
Sir if model is in angle how to set the model in csys & origin point
How does a Military Helicopter work?  (Pave Hawk)
18:09
Jared Owen
Рет қаралды 13 МЛН
NX Assembly Mass Properties: MassPropRollup Attributes for all Parts [NX 2212]
5:15
Taylor Anderson NX Videos
Рет қаралды 3,2 М.
黑天使被操控了#short #angel #clown
00:40
Super Beauty team
Рет қаралды 61 МЛН
黑天使只对C罗有感觉#short #angel #clown
00:39
Super Beauty team
Рет қаралды 36 МЛН
How to treat Acne💉
00:31
ISSEI / いっせい
Рет қаралды 108 МЛН
How to modify CSYS in UG NX
6:12
VindyCAD
Рет қаралды 13 М.
Part orientation# Extract punch and die # NX tutorial
10:06
CADCAM TECH360
Рет қаралды 1,7 М.
Unigraphics NX Co-ordinate System, CSYS for Beginners
7:29
TechDesign
Рет қаралды 53 М.
NX 12 Tutorial #6 |3D Model Curver , sweep  - Exhaust Manifold
21:30
CAD/CAM SOLUTION
Рет қаралды 72 М.
Using Wave Geometry Linker in Siemens NX 2312 - Beginner Friendly Tutorial
16:41
Solidworks- Assembly Training-Coordinate Systems
8:39
S Kenna
Рет қаралды 9 М.
Move to Layer in NX
4:47
Darova ME
Рет қаралды 2,9 М.
黑天使被操控了#short #angel #clown
00:40
Super Beauty team
Рет қаралды 61 МЛН