Man this one was hard. Tight spot, bent copper, should have used Uponor from the beginning.
Пікірлер: 35
@DumbCarGuyАй бұрын
The rare moments when you wish you owned a 1/2" copper pipe bender.
@cineaste1969Ай бұрын
Hey another difficult job made to look easy to you and your buddy Carlos! 👍🏼
@BrndnkslrАй бұрын
Service plumbing at its finest 👍 good work man
@Longeno55Ай бұрын
You dudes can repair anything.
@jimmyhai684027 күн бұрын
Great work! Tough space.
@tomdale1313Ай бұрын
another save by Carlos, thxs for sharing...
@aaronbaraiya3692Ай бұрын
Man that some old cool plumbing
@tomn4838Ай бұрын
I can tell your in a warm climate. All our water main valves (Chicago) are indoors so they don’t freeze. 😊
@pershingplumbing9007Ай бұрын
Southern California, yes sir
@brianlafleur997Ай бұрын
Great job 💯💯💯💯. No leaky leaks.
@Longeno55Ай бұрын
Carlos rocks! 👉🏼
@labmanmeАй бұрын
good work
@b.powell3480Ай бұрын
I would add unions on each side of the hot and cold water lines, then install ball valves for each line !
@pershingplumbing9007Ай бұрын
why unions?
@b.powell3480Ай бұрын
@@pershingplumbing9007 to make it easier to repair in the future
@matthewg7835Ай бұрын
Nice work in a tough spot… is it worth it to try and repair the old gate valves? Prob easier and faster to put in a better ball valve I’m guessing?
@pershingplumbing9007Ай бұрын
I wouldn't even try to repair those honestly
@johnlangley6449Ай бұрын
I would have pulled the toilet as much as I don’t want to 😮
@pershingplumbing9007Ай бұрын
Bruh I had the same thought going thru my head but I like to make things harder for myself
@scottmaz4063Ай бұрын
Unscrew packing nut whole stem comes out then unscrew it.
@fredhall4239Ай бұрын
why put brass swarfe into the hot and cold pipe work to clog ballvalve orfices, when you only had to cut and sweat out fittings and replace, awkward i know but thats why they employ plumbers.
@gregtroyplumbing985827 күн бұрын
SHANE AND LOS STRIKE AGAIN DYNAMIC DUO👍🏻😄
@pershingplumbing900727 күн бұрын
@@gregtroyplumbing9858 😂😂😂
@aaronbaraiya3692Ай бұрын
Also how to tell whether to repair a gate valve or to replace it?😊
@pershingplumbing9007Ай бұрын
It won't open or close the water off
@lv2fish501Ай бұрын
Weird having the main shutoff outside, easy for anyone to mess with.
@theantichrist4267Ай бұрын
Wow hotshot , where are the towels to soak up the water ??? Mold is a dangerous thing .
@pershingplumbing9007Ай бұрын
its concrete pal and we vaccumed it after we were done
@viralporchpirates8314Ай бұрын
Propress on soft copper…… some people’s children…..
@pershingplumbing9007Ай бұрын
It's not soft copper, it was bent type l and propress can be used on type k. I've seen it done several times, I've never done it but have personally seen it done
@randybeaumierАй бұрын
Transition to Pex or push on connectors.
@JamesBrown-db9pkАй бұрын
use 2 45s
@pershingplumbing9007Ай бұрын
Didn't have any but would have used a 45 and st 45 would have made the cold work probably
@Inmyopinion10101Ай бұрын
Should at least catch the dripping water in a tray.
@pershingplumbing9007Ай бұрын
It's concrete pal, not gonna hurt anything and the space was very tight