I learned a lot just by watching this. I appreciate the time you took to pass on this info.
@trueCABLE Жыл бұрын
Glad it was helpful!
@LeoRousseau10 ай бұрын
Thanks for the video! Very helpful! 👊✌️
@trueCABLE10 ай бұрын
You are welcome Leous. We are glad you found the content helpful.
@leoarata3017 ай бұрын
Thank you, quad 6 cable with standard compression connectors 5 days of frustration is over!
@trueCABLE7 ай бұрын
Hello Leo! You are welcome, and we are glad you enjoyed the content. Our unique RG6 compression F connector does indeed make termination of quad shield cable far easier and much less frustrating.
@JonnyAugust19 ай бұрын
Great video and quality
@trueCABLE9 ай бұрын
Thanks for the kind comment, Jonny!
@michaelsasso132 жыл бұрын
Getting the inside barrel of the F-connector between the outer jack and the foil is often a challenge and a time killer. I am looking forward to trying these new RG6 connectors. Thanks for the demonstration on peeling back the insulation. Very helpful.
@trueCABLE2 жыл бұрын
That is very true Michael! Not only are traditional "sleeve style" F-Connectors a time killer, but they can also be an arm and hand killer too. The trueCABLE RG6 F-Connectors are now for sale and I would love to hear your feedback.
@frankgonzales2232 Жыл бұрын
Love the colors on the tools !
@trueCABLE Жыл бұрын
Thanks Frank! When designing them, I thought of ways to be sure I could not lose one in the deepest and darkest tool bag that I own and proceeded like that!
@ZootyZoFo3 ай бұрын
Should that last foil shield around the dielectric be removed on shielded & quad shielded Coax? I keep reading where it should be removed but all the demo videos I have seen show them leaving that last foil wrap around the white dielectric on?
@robdf90242 жыл бұрын
Very well explained and neatly executed. You must be a maniac like me. I do not play with connectors even with a small braid.
@trueCABLE2 жыл бұрын
Hello Rob! Indeed, and thanks for the kudos. I hate forcing the "sleeve style" compression connectors onto coaxial...getting the sleeve inside the cable jacket even WITH a flaring tool can sometimes be very obnoxious.
@robdf90242 жыл бұрын
@@trueCABLE The flaring tools are sometime very funny. You just apply a bit more force than the due and then it males a small funny protrusion. On some connectors help to get inside the smallest part of the inside pin but not always. It is really an art and only if you are in the "mood" lol.
@ukrainianinternational2808 Жыл бұрын
Hello TrueCable! Where can I buy the light green cable cleaner? Thank you.
@trueCABLE Жыл бұрын
Hello! The green Cut & Strip tool is available on Amazon USA and Canada, as well as direct via our website truecable.com (USA sales only).
@nkgirishnk68782 жыл бұрын
Best practical lesson ⚘️🙏
@trueCABLE Жыл бұрын
Thank you!
@charnjitram38142 жыл бұрын
Great video i am struggling using standard f connectors due to the outside diameter of the cable where can i get the proper connectors from tried all types no one fits.
@trueCABLE2 жыл бұрын
Hello Charnjit! Thanks for the feedback and question. It comes down to fitment and knowing the specifications for both the cable and the F-Connector. If you are having issues then the F-Connector is too small for your cable. F-Connectors can and do vary in size. Coaxial cable varies in thickness according to amount of shielding, manufacturer, etc. trueCABLE F-Connectors auto-adjust for the cable jacket OD via a spring mechanism and will likely solve your problems--they are very forgiving of variable cable jacket ODs. Aside from that, careful research is required to determine what will fit your cable.
@edwinmcguire6040 Жыл бұрын
When making Outdoor connections, could I use Dielectric grease like I do with 12vdc trailer connections?
@trueCABLE Жыл бұрын
Hello! I think the better option is 3M mastic tape so you can be sure the entire thing is sealed up. The grease will degrade the circuit considering it is dielectric.
@edwinmcguire6040 Жыл бұрын
@@trueCABLE Thanks for the Quick reply and info.
@gsxr1000jt Жыл бұрын
Any way to test both ends after termination with a multimeter? If so what would be the in spec numbers and how you use multimeter to test?
@trueCABLE Жыл бұрын
Hello John! Great idea, and we already thought of that one. In order to get our spec sheets fully built out with relevant data (that the DSX-8000 does not provide) we had to use a Fluke Multimeter and test both ends of the cable (raw). If you take a look at the spec sheets for our Series 6 coaxial cable on our website, you will see a section "Electrical Characteristics". The majority of the resistance data was obtained with a multimeter, not the Certifier. A two-point resistance test was conducted on the center conductor and also DC loop resistance, using alligator clips.
@joaodasilva80082 жыл бұрын
Is there less lost signal with an RG 6 Quad Cable or is it the same with a normal RG6?
@trueCABLE2 жыл бұрын
Hello and great question! Yes, there is less signal loss with quad shield coaxial cable vs dual shield--everything being equal. In normal operation and under normal circumstances they perform largely the same and you would not notice a difference. The real difference is when there are external EMI/RFI sources that might interfere with your signal and quad shield is better at preventing that. When making a decision as to which to install, think of dual shield coaxial cable as the same as unshielded Ethernet cable. Think of quad shield coaxial cable as the same as shielded Ethernet cable. Use the one that fits the environment. Not everyone needs to use quad shield.
@glenbrawn543611 ай бұрын
Can you connect digital ariel to analog cable from old ariel.
@trueCABLE11 ай бұрын
Hello Glen! That all depends on the original antenna. If the original antenna is already using coaxial, then perhaps, if it is designed to use 75ohm. We would need to know more about your existing equipment and what you are seeking to do in order to provide a more concise answer.
@yusrilyuhaz8402 жыл бұрын
The conection of the installation is almost the same as the one I Made.
@silverthatrandomdragon55092 жыл бұрын
But is it indoor/outdoor-
@trueCABLE2 жыл бұрын
Hello and thanks for the question. This is riser rated coaxial cable, so indoor only. We also carry an outdoor version that can be used indoors & outdoors in residential environments. The rules change for commercial environments, though.
@nicksondevesi22472 жыл бұрын
I don't have tools, but I want to know how many mm to cut , need it assap
@trueCABLE2 жыл бұрын
The jacket is cut back a total of 13mm. The dielectric should be stripped back 6.5mm. We provide a visual reference for this in our Cable Academy blog, "How To: RG6 Quad Shield Coaxial Strip and Termination."
@joaodasilva80082 жыл бұрын
when are going to have RG6 Quad for exterior (CMX type)
@trueCABLE2 жыл бұрын
Hello. We stock quad shield outdoor (CMX) in 1,000ft and 500ft lengths. Black or white in color. See our website!
@kelleysimonds5945 Жыл бұрын
Could you cut the nonsense and unneeded junk to speed things up?
@trueCABLE Жыл бұрын
Hello Kelley. I am not sure what "nonsense" you are referring to, but if you could be a bit more specific that would be helpful. Keep in mind that what you may consider less relevant information is not the same for everyone and vice versa--what you might consider more relevant information someone else might consider less relevant. We do our best to balance. We are sorry you did not enjoy the video!
@boblim1227 Жыл бұрын
Yes what really are you looking for?. If you think you are too good, not neccessary to view and give commenta. These video are for diy apprentive. Why not start your own video and share with us what you know. Kindly advise.Thank you.