Rietveld refinement of x-ray diffraction data using gsas-2

  Рет қаралды 14,236

PhDzzz

PhDzzz

Күн бұрын

In this tutorial, you will learn Rietveld's refinement of X-ray diffraction (XRD) data using GSAS-II software. Initially, import the XRD data into the GSAS-II software. Then import the instrument parameter file, followed by the know structural cif file. Define the background and then run the refinement. GSAS-II will calculate a new XRD pattern based on the structural model and compare it to the observed data. The refinement process will adjust the structural model to minimize the difference between the calculated and observed patterns. Once the refinement is complete, GSAS-II will generate a report including refined structural parameters and other information.
CIF File download
• How to download a CIF ...
#xrd #gsas #Rietveldrefinment #materialscience #research #xraydiffraction #cif #crystallography
--------------------------------------------------
--------------------------------------------------
Contact: agscitool@gmail.com

Пікірлер: 66
@PhDzzz66
@PhDzzz66 Жыл бұрын
How to perform multiphase Rietveld refinement of XRD using GSAS-2 - step-by-step tutorial kzbin.info/www/bejne/n6WyYZ6VaqxkhJI
@PhDzzz66
@PhDzzz66 Жыл бұрын
Plotting XRD Data with OriginLab: A Step-by-Step Guide kzbin.info/www/bejne/qJObi6N-orlkgpo
@AmitKumar-i6j2p
@AmitKumar-i6j2p 22 күн бұрын
could you please make one video on le bail also?
@MehmetYlmaz-hb2jf
@MehmetYlmaz-hb2jf Жыл бұрын
I am a beginner in Ritveld analysis. I have watched your videos many times, but I could not apply it to the data I have. All my parameters are quite high. I also followed your applications to reduce the parameters, but I could not reduce the X2 value below 535. What should I do? Can you help me? Thank you
@PhDzzz66
@PhDzzz66 Жыл бұрын
First step, make sure your using correct phase parameters. To check this, please simulate the xrd data using Vesta software and compare it with experimental data. Make sure you use the same wavelength. If the phase parameters are close to the experimental xrd data then 2theta and peak intensity should match for all the peaks. You can watch this video: Download CIF file from COD and generate XRD data using VESTA kzbin.info/www/bejne/jn-4kGSibryMqKM Let me know how it goes.
@neoz3rxes387
@neoz3rxes387 Жыл бұрын
Hello, this tutorial was of great help, i am trying to perform refinement on a nanocomposite and a tutorial for multiphase refinement would help a lot.
@PhDzzz66
@PhDzzz66 Жыл бұрын
Glad that you liked it. I have received multiple request on the same topic and will be able to upload video in next month. Don’t forget to like and share with your friends.
@neoz3rxes387
@neoz3rxes387 Жыл бұрын
Hello again, I have been eagerly waiting for your tutorial, any possible update on multiphase refinement?
@PhDzzz66
@PhDzzz66 Жыл бұрын
please go through this video: kzbin.info/www/bejne/n6WyYZ6VaqxkhJI
@mehranalam1274
@mehranalam1274 2 ай бұрын
Hello sir how to calculate crystalline and amorphous percentage here ?
@PhDzzz66
@PhDzzz66 2 ай бұрын
Not sure on that!
@shailzasaini111
@shailzasaini111 2 жыл бұрын
Hi, Thank you for the video. I am a new starter. I do not get how you perform instrument calibration with well known standard. Could you please tell me the steps?
@PhDzzz66
@PhDzzz66 2 жыл бұрын
Thank you for your comment. In my case, the instrument calibration is done by measuring XRD of standard LaB6 sample. This is very common practice. You can ask further details to the XRD instrument operator. Hope it may have help you.
@shailzasaini111
@shailzasaini111 2 жыл бұрын
@@PhDzzz66 Yes, LaB6 is the standard one. Can we use any other material like La2O3 also ? Or is it necessary that it should be LaB6
@shailzasaini111
@shailzasaini111 2 жыл бұрын
@@PhDzzz66 Also, if we don't use calibration data and prefer the one that is available in GSAS, it will effect our results majorly or just a minor error would be there?
@PhDzzz66
@PhDzzz66 2 жыл бұрын
@@shailzasaini111 Yes, La2O3 is also fine.
@PhDzzz66
@PhDzzz66 2 жыл бұрын
@@shailzasaini111 It wont affect much as long as size of grain is not too small ~ 10 nm or so. If its bulk sample, then please use the available parameter in GSAS II. In this case, instead of refining micro strain you can refine U V W instrument parameters.
@shanmuga-v5z
@shanmuga-v5z 7 ай бұрын
hii. i completed the refinement. i couldnt find esds value in the .lst file. may you help me?
@chandasekharyellatur2848
@chandasekharyellatur2848 5 ай бұрын
Hi sir Please explain how to get the PRM file , where it available?
@PhDzzz66
@PhDzzz66 3 ай бұрын
Watch this video (around 11 min on the time line) kzbin.info/www/bejne/kHXCp6l-bLKpqq8feature=shared
@shubhamkumar-lc9fu
@shubhamkumar-lc9fu 11 ай бұрын
Where i can find the error bar in lattice parameter in out file created?
@PhDzzz66
@PhDzzz66 11 ай бұрын
Hi, it’s in the file along with the fitted values of lattice constant
@saribelvilaplana115
@saribelvilaplana115 Жыл бұрын
Hello, do you know if it is possible to refine de cell parameter or the angle, separately, in the monoclinic phase. If not it is possible to put a retricción over the angle?
@PhDzzz66
@PhDzzz66 Жыл бұрын
Hi, thank you for your comment. I haven’t done that before but it should be doable. You can try to import the phase details of mono clinic phase and see if such options open up or not. Late me know if it works for you. Please do like and share to support this channel!
@shahfahad1854
@shahfahad1854 7 ай бұрын
thank you, i have no instrument parameter file, So what should I do
@PhDzzz66
@PhDzzz66 7 ай бұрын
I have another video, please take a look at it!
@tanveeralop2163
@tanveeralop2163 Жыл бұрын
Hello Sir, if the compound contains double structure such as both hexagonal and cubic structure then how to perform refinement with GSAS II? Thanks in advance.
@PhDzzz66
@PhDzzz66 Жыл бұрын
For composites, you will have to import different cif files and then perform the refinement. In this case you will have to refine the phase factor. I will upload a video on refining composites in coming few days.
@tanveeralop2163
@tanveeralop2163 Жыл бұрын
@@PhDzzz66 Thank you Sir for your reply. I am eagerly waiting for this video.
@PhDzzz66
@PhDzzz66 Жыл бұрын
Multiphase: kzbin.info/www/bejne/n6WyYZ6VaqxkhJI
@PhDzzz66
@PhDzzz66 Жыл бұрын
kzbin.info/www/bejne/n6WyYZ6VaqxkhJI
@tanveeralop2163
@tanveeralop2163 Жыл бұрын
@@PhDzzz66 Thank you Sir
@thesmartway5851
@thesmartway5851 Жыл бұрын
Can the PXRD Data come from any other source like copper or restrictly from synchrotron source...
@PhDzzz66
@PhDzzz66 Жыл бұрын
Laboratory powder diffraction requires an X-ray source that is essentially monochromatic and so the Kβ line in the X-ray spectrum needs to be removed. Metal foil filters are one way of achieving this. The typical metals used to filter X-rays produced by a sealed X-ray tube, are Ni, Fe, Mn, V, or Zr. Filters preferentially reduce the intensity of the Kβ line in the X-ray spectrum compared to Kα as explained below. Note that absorption filters cannot be used to remove the unwanted Kα2 component from Kα radiation.
@vikas312yadav
@vikas312yadav Жыл бұрын
how strip kalpha 2 by Gsas 2
@PhDzzz66
@PhDzzz66 Жыл бұрын
Hi, there is no need to strip ka2. The k-alpha2 will be handled automatically if you configure the software correctly (I ratio of I2/I1). I don't have any XRD data to demonstrate it. Please share the XRD data file so I can record a tutorial.
@AjayVerma-gw8zj
@AjayVerma-gw8zj 2 жыл бұрын
Hello Sir, Can you please help me for the synchrotron XRD data refinement?
@PhDzzz66
@PhDzzz66 2 жыл бұрын
Hi, thank you for your message. The steps shown in this video should be sufficient to learn the refinement of synchrotron XRD. If you have any specific questions please let me know. Thank you!
@shahfahad1854
@shahfahad1854 9 ай бұрын
Background curve fluctuation is acceptable if Rwp is less than 10.
@PhDzzz66
@PhDzzz66 9 ай бұрын
Background curves follows the polynomial and can fit easily.
@shahfahad1854
@shahfahad1854 9 ай бұрын
@@PhDzzz66 thanks for your kind reply
@themusicaltraveller3085
@themusicaltraveller3085 2 жыл бұрын
Hello, can you please add the steps for dual refinement?
@PhDzzz66
@PhDzzz66 2 жыл бұрын
Hi thank you for your comment. Do you mean refinement of composite material with more than one phase? If so, I will try to find some free time to upload it.
@themusicaltraveller3085
@themusicaltraveller3085 2 жыл бұрын
@@PhDzzz66 yes exactly
@themusicaltraveller3085
@themusicaltraveller3085 2 жыл бұрын
@@PhDzzz66 thank you so much
@PhDzzz66
@PhDzzz66 Жыл бұрын
Here you go : kzbin.info/www/bejne/n6WyYZ6VaqxkhJI
@shanmugapriyaig8521
@shanmugapriyaig8521 Жыл бұрын
Hello anna, O2 atom z value is -ve. Is it okay?
@PhDzzz66
@PhDzzz66 Жыл бұрын
In some cases yes, but you must cross check it with the published papers. Please share, like and subscribe. Thank you!
@gaganam1790
@gaganam1790 Жыл бұрын
how can i get instrument parameter file ?
@PhDzzz66
@PhDzzz66 Жыл бұрын
From XRD instrument operator.
@bibilybaby9785
@bibilybaby9785 Жыл бұрын
​@@PhDzzz66can we download it?
@PhDzzz66
@PhDzzz66 Жыл бұрын
@@bibilybaby9785 NO, please ask the operator or perform refinement using in-build instrument parameters in the GSAS-2 software. I will upload a video on it soon.
@PhDzzz66
@PhDzzz66 Жыл бұрын
kzbin.info/www/bejne/kHXCp6l-bLKpqq8
@avinashmanoharan9007
@avinashmanoharan9007 Жыл бұрын
Hello sir, can you please let me know the difference between secondary phase, dual phase, multi phase and impurity phase ? Is there separate refinement procedures for the above mentioned phenomenons ? In case I am preparing BaSnO3, and after preparing the compound and performing XRD. In JCPDS, if I get peaks for both BaSnO3 and Ba2SnO4, which refinement technique do I need to follow ? And in case if I dope a material, the dopant peak is clearly visible means, which technique do we need to follow ?
@PhDzzz66
@PhDzzz66 Жыл бұрын
Hi, thank you for the comment. In your case you will have to use multiple phases during the refinement in the GSAS 2 software. Soon, I will upload a new video to answer your question.
@avinashmanoharan9007
@avinashmanoharan9007 Жыл бұрын
@@PhDzzz66 Hi, is the instrument parameter same for all materials ? How to get it ?
@PhDzzz66
@PhDzzz66 Жыл бұрын
Hi, yes, the instrument parameters should be the same for the XRD of a measured sample. You should contact the XRD operator for the instrument file.
@PhDzzz66
@PhDzzz66 Жыл бұрын
kzbin.info/www/bejne/kHXCp6l-bLKpqq8
@PhDzzz66
@PhDzzz66 Жыл бұрын
for multiphase: kzbin.info/www/bejne/n6WyYZ6VaqxkhJI
@gvishnumurthy1704
@gvishnumurthy1704 2 жыл бұрын
Can you refine my data sir
@PhDzzz66
@PhDzzz66 2 жыл бұрын
Hi, thank you for reaching out. I suggest you to follow the steps given in this short tutorial and if you face any difficulty then I can help you on that. Good luck!
@letmegraduate66
@letmegraduate66 8 ай бұрын
Hello, I have watched your video and it has been very helpful to me. I would like to know how to refine the data of doped Fe like NiAl17Fe03O4 using GASA
@PhDzzz66
@PhDzzz66 8 ай бұрын
If you know the phase details then just follow the steps…if you have any trouble then drop me an email
@letmegraduate66
@letmegraduate66 8 ай бұрын
@@PhDzzz66 what is ...
How to stack XRD data in origin - Step-by-Step Tutorial
8:32
“Don’t stop the chances.”
00:44
ISSEI / いっせい
Рет қаралды 62 МЛН
XRD data analysis: simple plotting and refinement in GSAS-II
12:06
pyGSAS (GSAS-2) Rietveld Refinement intro tutorial
28:38
Taylor Sparks
Рет қаралды 37 М.
Phase identification from XRD data with Profex
28:26
Profex Tutorials
Рет қаралды 40 М.
Basic X-ray Powder Diffraction Analysis using GSAS-II
18:01
Jeyadheepan K
Рет қаралды 12 М.
Diffraction Lecture 25: Rietveld Refinements
26:57
Pat's Perovskites
Рет қаралды 19 М.
Rietveld refinement of XRD data with known phases in GSAS
33:08
SAYPhysics
Рет қаралды 2,3 М.
Easiest & Best Way to do Rietveld Refinement Using FullProf software
32:06
“Don’t stop the chances.”
00:44
ISSEI / いっせい
Рет қаралды 62 МЛН