Will the LED temperature display timeout or is it always on?
@harisrani9106 Жыл бұрын
Thank you for such an informative knowledge
@aldymcpndg142 ай бұрын
Can i use the normally closed switch of the relay so i can use the heating and cooling function. I mean use the normally close switch of relay for heating element and use the normally open switch of the relay for cooling fun? Is that possible
@robojax2 ай бұрын
if you connect another wire to the Normaly closed terminal, for sure it should work.
@aldymcpndg142 ай бұрын
@robojax thank you very much.
@angelodesantis7749 Жыл бұрын
Thank you 🙏 working 220volt?
@serg3y2 жыл бұрын
Would the 24v work with 19V. and what would happen if you connect 12v to the 24v controller?
@robojax2 жыл бұрын
I have not tested but it should not work. the relay will not hold. the voltage is half. I believe there is 12V version or get boost converter to convert 12V to 24V here is the video kzbin.info/www/bejne/gn6umoN7lJeIq5Y
@mahlasutube2 жыл бұрын
Can we connect the same to a 2KW domestic water heater?
@mahlasutube2 жыл бұрын
One thing more, how much we can extend the sensor wire? Can we take the wire through the pipes carrying AC voltage?
@robojax2 жыл бұрын
I belive I provided the calcualtion. Read the current rating on the relay of this module and if you see 10A, then if your region voltge is 200, then P=220v * 10A = 2.2kW it should be enough. As for the length of sensor, it is hard to say, may be try it by shielding the sensor wire with allominum foil and extend it (inside the pipe with AC line) and see if you read the same temperatue. Except expriment, we won't know if there is not datasheet or information from the manufacturere of the sensor.
@mahlasutube2 жыл бұрын
@@robojax Thanks a lot for replying to my query, brother. I am just going to try W3230 220V AC version to install with a 25ltr water heater (2KW) instead of typical capillary thermostat switch. Let's hope it will work properly. I will try to make a video of its usage and let you know the results...
@thomasmcshane71992 жыл бұрын
Put one on my egg incubator. Thanks for the info.
@MyDarer2 жыл бұрын
Hey I don't know what's wrong with mine, but when I connect the bulb which is supposed to heat...the device starts going on and off
@florgemmp85596 ай бұрын
Thank you for tutorial❤
@StepperByStepper2 жыл бұрын
What does LLL in the Display mean?
@robojax2 жыл бұрын
Show LLL When the LLL is displayed, the temperature probe is not inserted, disconnected, damaged, and need replaced. Show HHH When HHH is displayed, the temperature probe is short-circuited and the temperature detection range is exceeded.
@StepperByStepper2 жыл бұрын
@@robojax thanks very much!!!
@robojax2 жыл бұрын
You are very welcome.
@AO-ek9qw3 жыл бұрын
when setting up the delay, in the example you showed, if the temperature drops below 65 during that 1 min delay, will it still turn on? thanks in advance
@robojax3 жыл бұрын
Hi, I don’t remember anything about this video. I would have to watch answer it. I believe if you watch it carefully , there shouldn’t be any questions left.
@AO-ek9qw3 жыл бұрын
@Robojax the video doesn't mention it, you only made sure the temperature doesn't drop below 65 during the delay period. please refer to 16:05 - 18:08
@robojax3 жыл бұрын
65 is just an example. But I moved my mousse and said what happens when it reaches to max and to minimum. Please watch it 2 or three times
@MyJuancho20104 жыл бұрын
Is it good to control viscous liquids, such as liquid glues?...Thank you.
@robojax4 жыл бұрын
as long as you can measure the temperature, yes.
@willimnichols37744 жыл бұрын
Thank you for your help I have one in my cold room and it works very good the best one working
@robojax4 жыл бұрын
You are welcome. The best thank you for me is to not skippin the ads and Subscribe 🔔 to my channel, like 👍 the video and do not skip the ads.. It is greatly appreciated. 🔔 😊. I will reply to all Subscriber's 🔔 questions. So make sure to Subscribe.😊 .
@ulricius4 жыл бұрын
Danke, sehr gut erklärt. Weiter so, finde ich sehr gut :-)
@robojax4 жыл бұрын
Bitte schön. Ich bin froh, dass Sie mein Tutorial nützlich fanden. Vielen Dank, dass Sie die Anzeigen nicht übersprungen haben und sie weiterhin ansehen. Das wird mir sehr helfen.
@tockatheman3 жыл бұрын
Does this 220v work in europe?
@robojax3 жыл бұрын
Please watch the video as I have explained it. I will answer any questions if not explained in video.
@rajendrawaiba15774 жыл бұрын
How many blubs and fan can be lit from this device?
@robojax4 жыл бұрын
I have shown it in the first 50 seconds. it is about Watts. So look at the back of your device and you will see the rating. Once you know how many watts, this can handle, then look at each bulb or fan rating and you will know.
@abousamah19673 жыл бұрын
But the proplem of such thermostate is the weak prope may be will melt in high water temp If it is metal best
@robojax3 жыл бұрын
The he maximum temperature this device can handle, it should work. It is made for that temperature
@cofa40115 жыл бұрын
Hi Ahmad ! I'm really late but i wish you a very good new year ;) Thanks for the work you do to help and inspire us !
@robojax5 жыл бұрын
You are welcome. Thank you. I am sorry for late reply. I was on vacation.
@jasiahtrace23733 жыл бұрын
I realize it's kinda randomly asking but do anybody know of a good place to stream new movies online ?
@VelloErit Жыл бұрын
Thank you!
@pedrolg3 жыл бұрын
Not good. I had two with failed relay after a little use, it won't witch off when OUT light is off.
@hajrudinzivinice4 жыл бұрын
Nice, thanx...
@robojax4 жыл бұрын
Most welcome
@PerthLtd3 жыл бұрын
Thanks
@adriancalin10512 жыл бұрын
România
@oscarbead4 жыл бұрын
Thank You Robojax! Purchased 2ea. DM-W3002 Temp. Controllers {topnotch Seller -=> juan17tres} Loong ago learned (the hard way) Need to Inspect C. origin PCB's. Quick scan of my 2 revealed: Good++ design, Good++ component specification Both passed function test ~~ HowEver…. Assembly: Huge Difference between the 2 #1 not up to "industry standard" but will do just fine #2 was a Near Term FAILURE Waiting to happen ... had to clean, reflow/fill several thru-holes Bottom Line: Pull out the PCB's and inspect/repair! ** Helpful Hint Re: all digital controllers ** The Most Common point of digital Controller failure is its’ relays. (Note: failed Sensors usually easy to replace and are Not “controller failure”) So, Industry practice is Controller relays switch External Relays. The External relays switch the working Loads. That way, controller relays only switch mA. Relays are Cheep -=> Rule of thumb: External relay rated capacity At Least 2X or More, than Max. load. FYI: Generally, contact type relays fail open, SSRs fail closed.
@robojax4 жыл бұрын
You are welcome. Than you for the tips and safety notes.
@Maher-3 жыл бұрын
Your tutorial has too many ads 👎
@robojax3 жыл бұрын
Get KZbin premium m.kzbin.info and you will see no ads. I spent hour making this video and you get it for free, can’t you wait 5 or 15 seconds ? Amazing