Running my Natural Gas Furnace on my Honda EU2200 Generator (not as straight forward as you think)

  Рет қаралды 19,186

Computer Creationz

Computer Creationz

Күн бұрын

Пікірлер: 79
@DF-mb9kc
@DF-mb9kc Жыл бұрын
10/03/2023, i just saw your video and after pulling my hair out for two days you have addressed the problem. i made the plug and it immediately took care of the ignitor on the furnace not turning on. I ran the unit for over an hour w/o any issues or codes. I can’t thank you enough for posting this video !!!! Sincerely, WI
@computercreationz
@computercreationz Жыл бұрын
So glad it worked, I did exactly the same thing and had to figure it out!
@jppalm3944
@jppalm3944 Жыл бұрын
Valuable information. Most people displaying hookup to furnace don't mention this. IMPORTANT. WITH NEW FURNACES, ELECTRONICS VERY VULNERABLE TO DAMAGE IF INVERTER WRONG TYPE
@paulr7547
@paulr7547 11 ай бұрын
I just got a new eu2200i figured out that the floating neutral was the problem. Your video confirms that was the problem
@computercreationz
@computercreationz 11 ай бұрын
At least now we know we can use our Hondas for something like this. Thanks for the comment
@paulr7547
@paulr7547 11 ай бұрын
@@computercreationz I just finished testing the furnace with ground/neutral cord end on the new eu2200i and worked perfectly.
@computercreationz
@computercreationz 11 ай бұрын
Great News!@@paulr7547
@tedjohnson64
@tedjohnson64 Жыл бұрын
Excellent explanation! I’ve watched a ton of videos on generators and you’re the first to point out this issue, which is a bit surprising because using a generator to power a gas furnace seems like it would be a very common use case. Cheers!
@computercreationz
@computercreationz Жыл бұрын
Glad you enjoyed it!
@kevinadamson6830
@kevinadamson6830 15 күн бұрын
I am in the process of performing this very thing and had no idea as I have a Honda 2000w generator. Thank you very much for this great information
@computercreationz
@computercreationz 15 күн бұрын
Glad you’re getting it figured out.
@808blackjack808
@808blackjack808 11 ай бұрын
Awesome, live in alaska and power goes out alot, and I just had this issue... thought I was so slick....👍
@TheWeissenheimer
@TheWeissenheimer 8 ай бұрын
This is the exact video and situation I was looking for. Thank you!! I don't typically do my own electrical work but I am handy enough that I'll entertain it if I find the right videos that make me feel good about doing it. I picked up a small Predator during the last power outage in our new home. It caught me off guard and I ran around all morning to get that sorted, but was very disappointed when I got home. I am sure this is the problem and I will test this out as soon as I can. I am certain we are going to lose power this week due to another storm (only 2 weeks since the last time!) and I want to make damn sure we are good this time around
@thomabb
@thomabb 10 ай бұрын
Important to note this is an issue only if you isolate the furnace from the main house panel when you run off the generator. The neutral and ground are bonded in your main electrical panel.
@computercreationz
@computercreationz 10 ай бұрын
I agree
@TheWeissenheimer
@TheWeissenheimer 8 ай бұрын
This was my biggest issue in finding the right video to solve my unique problem. On google most of the results I got had people talking about transfer switches. But in my situation with a "poor man's generator setup" I am literally trying to hook up my furnace as a stand alone appliance, which like you said isolates it from the house panel N/G bond and causes a unique issue where there is no ground reference for my modern/sensitive furnace
@cometcal2
@cometcal2 6 күн бұрын
Important to point out that this info applies to furnace motors that are not hard wired into the house. Also, the majority of small generators are bonded so you can plug the furnace cord into the generator without any adapters. All generators should indicate on the front panel whether it has a floating or bonded neutral. If you don't know for sure, contact your manufacturer.
@geebroni4118
@geebroni4118 10 ай бұрын
Wow, I knew when my Honda didn't work, that it had to be the furnace ecm. Even tried grounding the generator to my house grounding rod. Frustrated, put back to stock and now this video pops up. Will give this a shot.
@computercreationz
@computercreationz 10 ай бұрын
give it a try, worked for me
@richardkawucha1232
@richardkawucha1232 2 ай бұрын
I recently purchased a Westinghouse Dual fuel 4,000 watt generator. I learned that unlike my old Generac generator, the Westinghouse has a floating neutral. I installed a generator bypass switch which enables me to disconnect the furnace from the main. I also purchased a Neutral ground bonding plug. I typed up a list of instructions, for my wife, on exactly what to do to plug in the furnace. They are step by step including using the bonding plug. So the plug doesn’t get lost/misplaced, I made a label for it and mounted it to the top of the bypass switch box, and I laminated the instructions and taped them to the furnace next to the bypass.
@computercreationz
@computercreationz 2 ай бұрын
Sounds like you’re prepared. Good work!
@bobbo1946
@bobbo1946 10 ай бұрын
thx for the tip..went thru an ice storm and prolonged 0° windchill for a week..including brief power outage..so researching this..think your furnace draw at start up, getting the blower fan going, along with the igniter. is likely higher than the 400 watts.but maybe it's a very small unit..thx again ..never would have thought of this...
@computercreationz
@computercreationz 9 ай бұрын
Glad it helped!
@mr.campsalot6465
@mr.campsalot6465 10 ай бұрын
Dude you saved the day with this one! Thank you so much! Completely solved my issue
@computercreationz
@computercreationz 9 ай бұрын
Glad I could help!
@ZiggZagg11
@ZiggZagg11 25 күн бұрын
I did not not have this problem with my old Trane furnace and I have run it with my Honda EU2000I... But I recently had a new furnace installed and had them put a plug on it (just like old furnace) and haven't had a reason to use the generator (yet) on it... Good thing I stumbled on this video... 👀 I would have been mad thinking that I had it figured out and not having it work and of course stuck with a cold house... 👀
@computercreationz
@computercreationz 8 күн бұрын
Glad it helped, and that you have the generator just in case!
@baratono
@baratono Күн бұрын
I just leave my bonding plug in the outlet on the inverter generator. My Williamson boiler was not happy without it. It would actually ignite for a few seconds and then shut down. Something to do with the flame sense circuitry.
@berettaguy7445
@berettaguy7445 Жыл бұрын
A transfer switch makes it easy to run your gas furnace with an EU2200. Mine has a 1/2hp motor and one of my EU2200's will run it easily.
@computercreationz
@computercreationz Жыл бұрын
ultimately that’s the best way for sure. thanks for the comment
@bobbo1946
@bobbo1946 10 ай бұрын
are you saying the transfer switch solves the ground issue?
@berettaguy7445
@berettaguy7445 10 ай бұрын
I'm saying I have no "ground issues" when powering my furnace via the transfer switch.@@bobbo1946
@berettaguy7445
@berettaguy7445 10 ай бұрын
Apparently. My furnace runs just fine when powered by my Honda via my Reliance transfer switch...never had a "ground Issue".@@bobbo1946
@Ron-yv1yb
@Ron-yv1yb Жыл бұрын
Thanks. I ran into this problem year or so ago, drove me nuts🧐
@computercreationz
@computercreationz Жыл бұрын
Glad it helped
@RichCrider
@RichCrider 11 ай бұрын
Thanks for sharing your thought. You nailed it on this one.
@computercreationz
@computercreationz 11 ай бұрын
I appreciate that!
@mattwaters6987
@mattwaters6987 11 ай бұрын
This is good to know. Thanks for sharing this information. I made a plug right away just in case. 😊
@computercreationz
@computercreationz 10 ай бұрын
Glad it was helpful!
@kennethkole6815
@kennethkole6815 10 ай бұрын
I will be ready for the next outage thank you.
@computercreationz
@computercreationz 10 ай бұрын
You bet
@thomabb
@thomabb 10 ай бұрын
Don't wait for an outage to test your backup power.
@michelt5122
@michelt5122 Жыл бұрын
Quick tip for the video you made for the pencil tool, you can use the ankers and delete some ankers after pressing I on the keyboard this is how you make the curves exactly how u want them to be. There are some great short tutorials for photoshop and illustrator so u get the idea of how it's implemented the concept is the same in lightburn. Cheers and thanks for the videos your making!
@computercreationz
@computercreationz Жыл бұрын
I appreciate the tip, thank you
@scubaseppy
@scubaseppy 11 ай бұрын
Great video thank you, I didn't even think about this.
@peterhowells8509
@peterhowells8509 9 ай бұрын
Lot's of work ahead! exciting! woot! woot!
@computercreationz
@computercreationz 9 ай бұрын
Sure is!
@alant5757
@alant5757 Ай бұрын
Same thing goes for those portable power stations too
@computercreationz
@computercreationz 28 күн бұрын
good to know!
@droidvegas331
@droidvegas331 Жыл бұрын
Thanks for the tip!!
@computercreationz
@computercreationz Жыл бұрын
Happy to help!
@m.alanwilcko3090
@m.alanwilcko3090 11 ай бұрын
Is this plug still needed if the generator has a floating neutral but I have attached a grounding wire?
@StagArmslower
@StagArmslower 10 ай бұрын
grounding wire will ground the frame of the generator only but not the circuitry since it is still floating neutral
@fourfortyroadrunner6701
@fourfortyroadrunner6701 Жыл бұрын
A board I'm on were JUST discussing nonsensical "safety" features on vehicles which can actually be detrimental or even unsafe, OR DEADLY. As a guy who serviced HVAC for about 12 years back in the 80's--mid 90's I cannot imagine why a furnace needs such a "feature."
@computercreationz
@computercreationz Жыл бұрын
yes , it took me a while to figure it out! thanks for watching
@gyoungberg
@gyoungberg Жыл бұрын
It has to do with the flame rectification through the flame sensor. It can't get the signal through the flame if the neutral isn't bonded. If a newer (anything in the last couple of decades) furnace isn't properly grounded it will have the same problem connected to regular house wiring. You should also ground the generator.
@gibblespascack1418
@gibblespascack1418 11 ай бұрын
If you go through a transfer switch or interlock switch, then isn't the ground already bonded to the neutral?
@djl9154
@djl9154 10 ай бұрын
Maybe, maybe not. The electrician that connected the manual transfer switch may hook it up so it disconnects the neutral from the main box. The reason is there should only be one connection to house ground and that is typically at the main box, not the sub panel. Therefore, you may not be connected to the house grounding rod.
@gibblespascack1418
@gibblespascack1418 10 ай бұрын
Mine is a reliance Pro-trans 50A unit. It appears to disconnect the power only. That would make the negative and ground a pass through to the panel and the panel does have the ground and negative bound(left side attached to the ground and the right side attached to the neg for the power company). @@djl9154
@iwlhin3737
@iwlhin3737 Жыл бұрын
I just connect the generator neutral and ground to the house panel neutral and ground
@christopherchristopher2723
@christopherchristopher2723 3 ай бұрын
Why not just set up a transfer or interlock switch and plug the generator into that which of course will then run power through your house panel box?
@computercreationz
@computercreationz 3 ай бұрын
This video addresses a different issue, your suggestion is the the right way to to it but most people don’t think that far ahead. They run out buy a generator and assume it will work just by plugging it in to your furnace.
@Robert-cd5zr
@Robert-cd5zr 2 ай бұрын
As someone who is new to this, I was wondering if this is officially what one is supposed to do, or if doing this workaround is risky or against code or something? I know I have a lot to learn sorry if that's a stupid question
@computercreationz
@computercreationz Ай бұрын
nothing official about this video. it’s meant as fyi only. and do at your own risk!
@sarahines6210
@sarahines6210 4 ай бұрын
What kind of extension cord do you use to run from the Honda generator to the furnace?
@computercreationz
@computercreationz 4 ай бұрын
12 ga extension cord 25’ max
@sarahines6210
@sarahines6210 4 ай бұрын
Thank you!
@jamespeterson7414
@jamespeterson7414 Жыл бұрын
My Firman generator on has one outlet. Is there a way to get around this problem with only one outlet?
@computercreationz
@computercreationz Жыл бұрын
you might try, a splitter where you plug one end to your generator and the other end had two female outlets plug this into one the the extension cord into another. try are your own risk!
@jamespeterson7414
@jamespeterson7414 Жыл бұрын
@@computercreationz I was gonna try running a power strip out of the generator/ an extension cord to the furnace/ and a male plug with the hot and neutral cut off into one of the outlets on the power strip. I'll try both ways. Thanks for the feedback.
@BOB12349307
@BOB12349307 Жыл бұрын
i would add an earth ground to it
@computercreationz
@computercreationz Жыл бұрын
thanks for the input
@BryanTorok
@BryanTorok Жыл бұрын
Are you recommending adding an earth ground (as in a ground rod) to the generator? Whether that would work for this would depend on the resistance from the generator ground to the house ground. And, you would still have to bond the neutral at the generator to the ground.
@BOB12349307
@BOB12349307 Жыл бұрын
if you remove the earth ground you need to replace it with an earth ground on the generator @@BryanTorok
@BryanTorok
@BryanTorok Жыл бұрын
@@BOB12349307 The neutral from the power company and the house neutral are tied together and bonded to ground at the service entrance. For the furnace to work, the neutral from the generator needs a low resistance path to the service entrance ground.
@BOB12349307
@BOB12349307 Жыл бұрын
i wouldnt use the house ground if your running it alone. but if you are doing a whole house hookup you have to use the house ground. and you have to remove the bonding jumper from your generator by code.@@BryanTorok
Keep Your Family Warm During A Power Outage By Installing This $5 Part
11:47
The DIY HVAC Guy
Рет қаралды 2,2 МЛН
This Could Keep Your Family Warm During An Emergency Power Outage.
16:38
The DIY HVAC Guy
Рет қаралды 2,5 МЛН
Sigma Kid Mistake #funny #sigma
00:17
CRAZY GREAPA
Рет қаралды 26 МЛН
路飞做的坏事被拆穿了 #路飞#海贼王
00:41
路飞与唐舞桐
Рет қаралды 25 МЛН
Quando eu quero Sushi (sem desperdiçar) 🍣
00:26
Los Wagners
Рет қаралды 13 МЛН
Must Have for Your RV, Portable Generator, Honda Review EU2200i, EU2000i, EU1000i
19:26
Keep your Heat on during Power Outages (generator/inverter)
5:15
Anthracite Energetics
Рет қаралды 8 М.
Using A Car Battery To Power Your Furnace During A Power Outage
10:47
The DIY HVAC Guy
Рет қаралды 378 М.
Emergency Heat | How To Power Your Gas Furnace When The Lights Go Out
9:42
Everyday Home Repairs
Рет қаралды 132 М.
Best Whole Home Super Quiet Inverter Generators!
27:44
The Den of Tools
Рет қаралды 247 М.
Stay Warm During A Winter Power Outage With This.
16:40
The DIY HVAC Guy
Рет қаралды 417 М.
RV Generators and what we learned
26:17
Retro RV Recon
Рет қаралды 80 М.
Sigma Kid Mistake #funny #sigma
00:17
CRAZY GREAPA
Рет қаралды 26 МЛН