Residential receptacle location requirements Part III

  Рет қаралды 4,523

Ryan Jackson

Ryan Jackson

Күн бұрын

Пікірлер: 40
@davidpanysr2854
@davidpanysr2854 10 ай бұрын
The Mount Vernon Estate ... hallowed ground (no pun intended) Had an opportunity to visit the estate back in 20, an outstanding experience! Touring the Mansion, Gardens, Tomb, Farm, Distillery, and the Wharf... appreciate your video too
@rafaelvelasco6357
@rafaelvelasco6357 10 ай бұрын
It's awesome to watch your videos. You make it so easy to understand. Thank you, Ryan!
@bobbyb2952
@bobbyb2952 10 ай бұрын
Great job explaining these in layman’s terms!
@alanagnew3451
@alanagnew3451 10 ай бұрын
11:00 showing examples of receptacles satisfying the requirements for decks and the rear wall of a building was helpful to reinforce the learning.
@garbo8962
@garbo8962 9 ай бұрын
Amazed while the NEC has a minimum requirement of needed receptacles in homes and hospitals but only a very few commercial buildings. I visited a recently remodeled maybe 20 by 30' main entry to a large building that had sets of electrically operated doors at both ends but no receptacles. Janitor was running a vacuum cleaner with an extension cord that electric doors kept closing on. Project engineer said no receptacles were installed because its not required by the code. The only place that comes to my old mind might be receptacles would have to be I stalked in elevator pits, hopefully within 25' of all roof top heating & AC units, switchgear rooms.
@UrgoMeister
@UrgoMeister 10 ай бұрын
Super helpful! Thanks
@RyanJacksonElectrical
@RyanJacksonElectrical Ай бұрын
I can't beleive I didn't see this until now. Thank you so much for that, it is very kind of you!
@thetruth4519
@thetruth4519 9 ай бұрын
Loved every minute of it!!
@RyanJacksonElectrical
@RyanJacksonElectrical 9 ай бұрын
Glad to hear it!
@thetruth4519
@thetruth4519 9 ай бұрын
@@RyanJacksonElectrical You helped me pass the Masters test in December. 3 weeks of hardcore studying, pass 1st time.
@RyanJacksonElectrical
@RyanJacksonElectrical 9 ай бұрын
@@thetruth4519 That's awesome! Congratulations, that's a huge accomplishment!
@iaov
@iaov 10 ай бұрын
Excellent. Thanks Ryan!
@brianerock
@brianerock 4 ай бұрын
Some new dryers (some all-in-one with washer, some not) use heat-pump technology (and are ventless) that are supplied by 15 A, 120 V rather than 30A, 120/240 V, so all the more reason even where a stacked combo unit supplied by 30A, 120/240 V is REPLACED, the new laundry equipment may need a 15 A, 120 V receptacle outlet.
@jefffielder2429
@jefffielder2429 10 ай бұрын
Thank you so much for all your time and effort in doing this. It was very good
@ToastEnmotion
@ToastEnmotion 9 ай бұрын
Love these videos. Thanks Ryan!
@ed6837
@ed6837 6 ай бұрын
TY great job. like your videos.
@shawnkegel6526
@shawnkegel6526 10 ай бұрын
Great series!!
@davidroddini1512
@davidroddini1512 10 ай бұрын
I don’t know if there are exceptions or how long outside receptacles were required. But the apartment complex I live in doesn’t have any exterior outlets. However, according to the lease agreement we cannot put up outside lights or use any electrical equipment outside. Using any electrical device outside is a violation of the lease agreement and you can be evicted.
@hiroshiyokoyama9695
@hiroshiyokoyama9695 10 ай бұрын
Thanks for many informative videos. I have a question about GFCI receptacles and bootleg grounding. I understand that bootleg grounding is a violation of the current NEC. That said, I am wondering from a purely technical point of view why bootleg grounding is bad for a stand-alone GFCI receptacle as a replacement of a two-prong receptacle. With no receptacles on the load side, the GFCI receptacle with bootleg grounding seems to be a better configuration than that with an open ground. My question is purely technical. Your insight is very much appreciated.
@RyanJacksonElectrical
@RyanJacksonElectrical 10 ай бұрын
For existing installations it is legal (if we mean tge same thing by "bootleg"). See 250.130(C).
@larrylawson5172
@larrylawson5172 10 ай бұрын
George Washington's Mount Vernon, Mount Vernon, VA. looking south.
@RyanJacksonElectrical
@RyanJacksonElectrical 10 ай бұрын
Winner!
@Ittiz
@Ittiz 10 ай бұрын
"for a different reason I don't remember the 90ies" College years? 😉On a side note it seems this new code is going to throw a lot of stuff on my property out of code. But coincidentally there are modifications I made, not knowing these requirements, that fixed some places that would now be out of compliance. Basically for many of the same reasons you stated. We have more things we need to plug in or charge. So, whenever I'm modifying a space and changing the electrical I think about how many outlets I'll need in the space to meet my needs. The number is usually a lot! My family is lucky I'm handy, because my wife asks me all the time "um would it be possible if we could have an outlet here?"
@stephenboanerges7246
@stephenboanerges7246 10 ай бұрын
Hey there Ryan, do you have a video on how to ground a sub panel in a detached garage for dwellings? Please leave me a link if so. Thanks in advance.
@RyanJacksonElectrical
@RyanJacksonElectrical 10 ай бұрын
No, but that's a great idea. I'll put it on my to-do list.
@nhzxboi
@nhzxboi 10 ай бұрын
How many hotels have you been in that have a pile of furniture receptacles plugged into a fixed receptacle on a multi-outlet adapter that combines the fridge, microwave, TV and whatever else? I see those things as dangerous . I'm still alive though. Sometimes you have to move that heavy hotel furniture to reconnect some of the junk you want to use. I only do that after my bed bug inspection.
@denverbraughler3948
@denverbraughler3948 10 ай бұрын
In basements, does NEC not require an outlet in each unfinished space in addition to what are required for specific equipment?
@MrPhillip262
@MrPhillip262 10 ай бұрын
The Juliet balcony got me on a project once. The architect showed Juliet balconies for a multi-story high rise residential, 6 stories and about 125 units. The architect didn't provide a sliding door, but a sliding window and the balconies weren't shown on the floorplans, just the elevations, so when I am working in autocad there was no balcony and it showed a window instead of a door. The project passed plan check, rough inspection signed off, electrical final signed off, building final signed off, and it was only when they got to Certificate of Occupancy did they ding us. By that stage all the walls are not only closed, but textured, painted, trim and flooring in, the building is literally ready to open save the CofO. Thankfully my company wasn't hit with fault, because they had to open the drywall on 125 units just to install one receptacle. The stupid Juliet balconies were only 3" deep, you couldn't even set a foot onto the decking it was so narrow.
@RyanJacksonElectrical
@RyanJacksonElectrical 10 ай бұрын
Wow. Just...wow
@HellsFallenAngel1
@HellsFallenAngel1 10 ай бұрын
9:50 That's excessive. Great videos, thanks for the information.
@sampsanity
@sampsanity 10 ай бұрын
Mount Vernon is the picture..
@samoblinger1922
@samoblinger1922 10 ай бұрын
Super awesome
@TheOGize
@TheOGize 10 ай бұрын
Thankyou for the videos keep it up 👍🏻
@ismailsiglam3544
@ismailsiglam3544 Ай бұрын
Thank you 🙏
@dane5167
@dane5167 10 ай бұрын
if the foyer walls are all closet or cabinet space do i still need an outlet?
@Electrician_kenz
@Electrician_kenz 10 ай бұрын
Thank you.
@mechelb4158
@mechelb4158 10 ай бұрын
What about do the unfinished portion of a basement for example or car bay need each a direct line ? Or can they be daisey chained?
@ErnieLA-
@ErnieLA- 5 ай бұрын
Awesome
@hatchetation
@hatchetation 10 ай бұрын
At 22:50 ... let's just agree that foy-AY is the worst pronunciation. FOYer is perfectly acceptable English, familiar in Utah and around the anglophone world. In French, it's more like fwa-yay. foyAY Is a pretentious half-way pronunciation used by francophiles and people who spend a lot of time around theaters.
@lahcfaou9207
@lahcfaou9207 10 ай бұрын
Thank you
Residential receptacle location requirements Part II
29:34
Ryan Jackson
Рет қаралды 7 М.
406.9 Receptacles in Damp or Wet Locations
21:54
Ryan Jackson
Рет қаралды 3,1 М.
“Don’t stop the chances.”
00:44
ISSEI / いっせい
Рет қаралды 62 МЛН
2023 210.52 Dwelling Unit Receptacle Outlets
19:04
Ryan Jackson
Рет қаралды 5 М.
How an architect analyzes a site in 16'
16:12
A-Architecture
Рет қаралды 2,7 М.
Changes to NFPA 70E 2024 edition
1:05:54
Ryan Jackson
Рет қаралды 9 М.
Electrical conductor types in the NEC
28:03
Ryan Jackson
Рет қаралды 13 М.
404.1 Scope (Switches)