Hi man! As always i say, you are incridible man ^^, i made the tests here and everything was OK. Thanks man and congratulations to give your Know-How to us.
@electricalautomation10 ай бұрын
Hi My friend! I remember you are my subscriber since my channel was setup three years ago. Thanks again! I am super glad the videos could be helpful!
@user-bb2co9yx8p Жыл бұрын
Thank you for the info, very valuable and easy to follow
@electricalautomation Жыл бұрын
Glad it was helpful! Welcome!
@AegisRick2 жыл бұрын
Saved my bacon with this video. Many thanks man.
@electricalautomation2 жыл бұрын
Thanks Buddy, Glad it was helpful.
@mochammadferryono3652 жыл бұрын
I Will to try this way, thanks for your information, i hope this can work
@electricalautomation2 жыл бұрын
Please try, and it should work.
@pranaychauli2335 ай бұрын
I really enjoyed your video, thank you for sharing such valuable content. I have a couple of questions regarding my PLC CPU. I'm looking to choose proper memory, but I'm a bit confused about which memory card to choose. Option 1: 6ES7954-8LF02-0AA0 This seems to be a spare part for SIMATIC S7, offering 24 MByte memory with 3.3V Flash, suitable for S7-1x00 CPU/SINAMICS. Option 2: 6ES7954-8LF03-0AA0 Similarly, this memory card is designed for S7-1x00 CPU/SINAMICS, providing 24 MByte memory with 3.3V Flash. For my second query, my CPU has read access but only write access is protected. If I reset the CPU from online and diagnostics, then reload the original program backup after removing the password, would it work?
@electricalautomation5 ай бұрын
If you have to use 24MB card, order 6ES7954-8LF03-0AA0, the xx02 is phase out part number. Typically a 4MB size card is good enough unless you are going to do huge project. You method will not work, your PLC will still be password protected because the HW configuration located in the card, it will work for your CPU once you use it and power up your CPU. You can upload your PLC to TIA Portal (HW & program), remove the password from the HW configuration, then download the CPU. Then you are free to use this CPU.
@moniruzzamanshohag Жыл бұрын
Great job 👍
@electricalautomation Жыл бұрын
Thank you! Cheers!
@abubakkarsiddic65116 ай бұрын
Hi. Thanks for sharing the knowledge. My question is, I somehow manage to get the upload from the password protected PLC. Now I have the uploaded project in my hand. But I don't have the original project. In this case, I'll use the SMC card in transfer mode and wipe it the protected PLC. After that I can download the uploaded project to that empty PLC directly right? Waiting for your reply.. Thanks in Advance.
@electricalautomation6 ай бұрын
Using the card shown in the video can reset and wipe out your PLC. The program and Password in the PLC will be gone. Then it will be a fresh device for you
@phumulasokhulu97532 жыл бұрын
This was helpful, thanks.
@electricalautomation2 жыл бұрын
Glad it was helpful! Welcome!
@framos99918 ай бұрын
Very useful, Thank You!
@electricalautomation7 ай бұрын
Welcome!
@souhailkamali922314 күн бұрын
What happen if i format the memory card before insert it ?
@fayezahmed982811 ай бұрын
Thank you, very helpful!
@electricalautomation11 ай бұрын
Glad it was helpful! Welcome!
@wojciechrebacz Жыл бұрын
Can you explain me if i think good? Can I access protected program if i have two cards (one with original protected program and second empty) using this method?
@electricalautomation Жыл бұрын
Sorry, it doesn't work. Once you use a empty card to reset the CPU, the program is gone.
@ismailyavuz73992 жыл бұрын
Windows biçimlendirme yapılmış bir siemens sd kartın geri dönüşü varmı? Şuan tia portal programı sd kartı görmüyor seri numarası yok oldu
@electricalautomation2 жыл бұрын
No, DO NOT USE WINDOWS TO FORMAT SIEMENS CARD. If you do, it can not be used for PLC anymore.
@alsadigmohammed7305 Жыл бұрын
Hello sir, If I did that and upload the program to SMC from protected PLC , i know the program will be lost , but can I put the SMC in PLC and run normally? Because I have a program uploaded in SMC ?? PLEASE 🙏.
@electricalautomation Жыл бұрын
No you can not run because the SMC card was set as "transfer" rather than "program"
@GazCripps Жыл бұрын
@@electricalautomation But couldn't you plug the SMC back into your computer and set it back to program in TIA?
@akshaykumarsaini12752 жыл бұрын
If I don’t have original backup after that will it work ?
@electricalautomation2 жыл бұрын
No, sorry. The card is used to 'RESET' the PLC, it will wipe out the PLC. You will lost the program. Therefore, you need original TIA Portal program.
@MiguelGomez-rc7ou9 ай бұрын
Hello Greetings I have a 1200 blocked. Always ask me for password. I done this procedure with 2 mb Simatic memory card with a empty program, without password and full access using Tia Portal V17. But I cant get access, the PLC still have protection. Any help?
@electricalautomation9 ай бұрын
I think you missed some operations. Also I don't think the video shown the 2mb is available for the reset operation.
@MiguelGomez-rc7ouАй бұрын
@@electricalautomation HI, Sorry for this late response Thank you for your time to respond, it really took me a while to try this again. You were right that the 2mb card was not listed on the cards for the procedure. so I bought a 4mb model 6ES7-954-8LC03-0AA0 But I still can't erase the CPU I follow the same procedure that you do in the video. After configuring the card as transfer, a S7_JOB.SYS file and a SIMATIC.SYS folder appear, is that normal? Any ideas, what am I doing wrong? I am with a CPU 1212C Firmware V4.6 with TIA Portal V17
@libanabu62223 жыл бұрын
nice video man
@electricalautomation3 жыл бұрын
Glad you like, Thanks, Hope it could be helpful.
@tienluongvan6519 Жыл бұрын
This works for Fail Safe CPU S7 1500 also?
@electricalautomation Жыл бұрын
S7-1500 has memory card and it also come with reset switch. It operators difference with S7-1200
@tienluongvan6519 Жыл бұрын
@@electricalautomation so do you have solution for S7 1500?
@mecproflda4056 Жыл бұрын
also works with TIA V12?
@electricalautomation Жыл бұрын
This is the hardware related operation, you could try, V12 should be the same operation.
@ashwingomez24783 жыл бұрын
Hi there, Can this be done on a 4 MB card?
@electricalautomation3 жыл бұрын
Yes, as long as the size of the program in the CPU load memory is less than the card.
@derina.maleek94083 жыл бұрын
Well done thanks
@electricalautomation3 жыл бұрын
Thanks, Hope it could be helpful.
@sdgtuttiigiorni2028 Жыл бұрын
hi, thanks for the video…. can it work with mc 512 kb? mod. 6ES7953-8LJ11-0AA0? thank you
@electricalautomation Жыл бұрын
Hi, unfortunately, 6ES7953-8LJ11-0AA0 is the S7-300 card, and it does not fit for S7-1200/S7-1500
@alemmoldabekov4776 Жыл бұрын
Hi, will this work with plc 1500?
@electricalautomation Жыл бұрын
Yes
@ctrnetwork88794 ай бұрын
Can it unlock Password S7-1500?
@electricalautomation4 ай бұрын
Not really, this is for reset CPU, not for crupt a sealed program.