In 50+ years, I’ve NEVER seen a slump test performed like that!!!
@ooslum2 жыл бұрын
I thought I was in a different world.
@anand42365 жыл бұрын
We did this scc on our final year project. The slump indicates the horizontal flow ability of scc..i,e without any obstruction to its flow in any reinforcement. As per EFNORC guidelines the slump flow should be lies in between 650 MM TO 800MM then only it becomes a scc mix. After this test V-funnel and L-box test was also conducted to know it's filling ability in any vertical form work and passing ability on horizontal surface.
@mathtime45785 жыл бұрын
Did they know that it was upside down lol
@Dragon-Slay3r2 жыл бұрын
German equaliser
@bobsmoot84542 жыл бұрын
That’s some soupy fine aggregate concrete, thin shelled precast piece by looking at the vertical clearance, I wonder if the “rock” segregated out on those vertical walls.
@elementarycivilengineer51954 жыл бұрын
To everyone who are barking in the comments section: a concrete is said to be SCC if it fulfills 1. Filling ability 2.passing ability 3. Resistance to segregation. We hv different tests to perform n chck the properties..this test falls in the category of filling ability, known as the slump flow test. In which we measure the diameter of the spread. The range is 500mm to 800mm..but for reinforced sections it should satisfy 700mm-800mm(SF3) category. And for your information, the orientation of the slump cone has little or nothing to do with in SCC. It's just to fill the concrete easily in the cone. Thats it
@sebotol3ribu8763 жыл бұрын
o nice.....may I ask for the material properties and the concrete job mix 👍
@bajak14383 жыл бұрын
Hallo! Was von Firma ist das?
@GregTGolden4 жыл бұрын
How much slump do you want?? All of it
@elementarycivilengineer51954 жыл бұрын
100% slump for SCC .we measure the horizontal spread n not the vertical distance as in case of vibrated concrete.
@33ace334 жыл бұрын
What is this called and used for?
@akmalkenit27767 жыл бұрын
Why cone of slump test like that?can explain 2 to me for what?for flow?
@noobgamer357t97 жыл бұрын
Akmal Kenit its self consolidating concrete this is an s ring slump test most places per their requirements will have you do a j ring test which is the same thing but with a 20ish inch diameter ring with several bars going down to the board to simulate rebar. You pull it the same and measure the two within i believe 5 minutes tops fron eachother and make sure they are within 2 inches of the recorded. Diameter
@xdeddy76446 жыл бұрын
Its called a spread test Its done for self consolidated concrete It means for concrete that doesnt need to be vibrated .
@johnquinn59035 жыл бұрын
It’s Self compacting concrete.easy work to fill a steel mould no skill in filling that
@skeets60602 жыл бұрын
What is it ?
@kucingucing9 ай бұрын
self compacting concrete
@paulmckenna17097 жыл бұрын
why are they putting concrete on polystyrene??
@brankotod46467 жыл бұрын
they make a pontoon
@marlin123ish5 жыл бұрын
the styrene is the form it will be pulled out after curing. I was a formworker did many like this
@stivi7392 жыл бұрын
@@brankotod4646 its a hollow box
@patclarke83864 жыл бұрын
Up side down
@pegas11003 жыл бұрын
Какую марку бетона используйте?
@ostoja2710 жыл бұрын
What the guy is doing in the beginning of the movie is not a proper way of testing concrete workability.
@dragansalinovic31199 жыл бұрын
cxf
@dragansalinovic31199 жыл бұрын
cxf
@CJM4427 жыл бұрын
They are not testing slump, they are testing the flow ability of self consolidating concrete - SCC
@rubenfigueroa63227 жыл бұрын
Christian Macol
@gudalawrence20287 жыл бұрын
ostoja27 was gonna ask if he's testing for workability
@Argle19654 жыл бұрын
Wow. These acrylic pour videos are getting serious.
@suep94454 жыл бұрын
😂🤣
@Farage5284 жыл бұрын
Why did I think this would be good !
@georgjeckle50054 жыл бұрын
Der hält den Trichter falsch herum da wird beschissen 😃😃😂😂
@johnhenshaw76552 жыл бұрын
It’s not slamming ,it’s slump testing.
@dominikradlinger3848 жыл бұрын
Ausbreitmaß messen hab ich selten so gesehen😂
@hawar95355 жыл бұрын
Wozu eigentlich? 🤔
@TheDalk6 жыл бұрын
First thing wrong. Slump test is incorrect. Fill Half. Agitate with 25 strokes. Fill full agitate again. Lift off. Then measure. Second . Back the truck into your form. Third. To get the concrete to flow and fill correctly tell the driver to add 30. Fourth. Use a vibrator Fifth. Have concrete guys do The job. Not factory shop guys.
@nicknoland97046 жыл бұрын
So... First, you realize it wasn't a slump test? Second, still not a slump test.
@grantschelfhout12276 жыл бұрын
Hi mate no slump test here it was a spread test ie 500, 600 spread etc
@grantschelfhout12276 жыл бұрын
TheDalk Hi mate it’s a spread test not a slump test as conducted with all super workable/self compacting concrete mixes.
@harrykohlmann60835 жыл бұрын
Die brauchten die Rüttelplatte nicht mal bewegen ,schon lief die Brühe, schätze B20 Festigkeit
@ЛевНатанович-с4ж9 жыл бұрын
а самозамесывающегося бетона нет ? а то я задолбался.
@mirchaursu94545 жыл бұрын
ну вам прям всё сразу, куда спешить? бетонщики тоже люди...
@gonzaloc15866 жыл бұрын
Y la compactacion?
@dirklouw14282 жыл бұрын
What did they measure
@alexanderbobex64583 жыл бұрын
Dobro!
@guzmanbueno61315 жыл бұрын
El cono de Abraham se usa al reves!
@-andr9 жыл бұрын
ponjatie podviznosti betona za s4et plastifikatorov ne znakomo? umnik. privet iz skandinavii
@liderbeton7 жыл бұрын
SCC beton MB 40
@daniellevisoares273 жыл бұрын
queria ver a peça pronta
@roberthollinger84372 жыл бұрын
The slump cone is wrong side up!
@turkaytopcan23455 жыл бұрын
Akışkan beton
@krzysztofk45487 жыл бұрын
jak nazywa się to badanie???
@bajak14383 жыл бұрын
Badanie na rozlewanie
@omerfarukdaskn95087 жыл бұрын
Bu nasıl slamp alma ? betonun dağılma alanı kalitesizliğini gösterir
@sebotol3ribu8765 жыл бұрын
Wah ga bisa tahu job mix formulanya ya
@sebotol3ribu8765 жыл бұрын
Maximum size aggregate?
@يسرىخنجر-و6ه3 жыл бұрын
10 mm.
@sebotol3ribu8763 жыл бұрын
@@يسرىخنجر-و6ه ok, 10mm coarse aggregate The smaller the aggregate used, the more cement there is or is there another solution?
@inyomantongkilana29867 жыл бұрын
harga terllalu mahal
@jonhaynes15772 жыл бұрын
Good lord why even slump test that straight water would not have been any different
@turqutmemmedov16308 жыл бұрын
standart F>620mm bu F=650 QUSMA vermelidir fikrimce..
@delayu_sam6 жыл бұрын
Прикольно
@zhaiyk20259 жыл бұрын
Самоукладывающися бетон.
@carloseyzaguirre61514 жыл бұрын
This guy is holding the cone upside down... for a proper slump test the cone sits on the larger diameter side
@VLiviu10 жыл бұрын
Treaba românească. ..
@1194077387 жыл бұрын
gracias a las matematicas podemos realizar calculos exactos de volumenes.
@josegalatas30205 жыл бұрын
El cono de Abrams
@philmacgregor13744 жыл бұрын
That wasn't a slump test pouring that way will give you segregation and that much water in the mx will make weak concrete ,,,all in all a crappy concrete pour !
@bubba94824 жыл бұрын
Phil MacGregor that’s called a spread test. Getting the concrete that wet was 100% chemicals. You can tell by the lack of segregation. W/c is probably in the .40-.45 range. I’m sure its a good strong mix.
@jgarde6 жыл бұрын
Il utilise le cône d’Abraham à l'envers c'est pas sérieux comme démonstration !
@hugelhagel8 жыл бұрын
ausbreitmaße werden aber anderst gemessen lol
@deinjoinie4 жыл бұрын
Fliessmass!
@soilengreen5 жыл бұрын
Ja ja ja , menuda mierda de hormigón que lleva agua para ahogar los peces
@mirchaursu94545 жыл бұрын
и после этого они пытаются научить нас строить????? ХА ХА ХА
@wladimirgrimailov13802 жыл бұрын
Вас учить , что фуй тупить.
@hremzo7 жыл бұрын
Rijedak bre
@SubieRow4 жыл бұрын
Oh the suspense.... Has cost you a thumbs down...down....down
@batkurac5 жыл бұрын
Bosanci i Slavonci a ko bi drugi
@lotlotpiedragorda95469 жыл бұрын
Lotlot schwaner: Thanks sa aking kamay Na hindi nakakakita.show mo, Show ko rin.
@MMALAHOFF8 жыл бұрын
Ljudi, sta to radite bre!??
@brankotod46467 жыл бұрын
slušaj šta pričaju
@apwk1207 жыл бұрын
坍落桶使用错误。这样结果偏大!
@louyon32044 жыл бұрын
中外差异?
@apwk1204 жыл бұрын
Lou Yon. 不是中外差异,是按照标准检测,他们使用错误
@louyon32044 жыл бұрын
@@apwk120 按标准,这个塌落度也太大了,除非特殊要求,是不能用的。
@louyon32044 жыл бұрын
@@apwk120 另外他们测量塌落度的方法也不一样,估计是另一个系统。
@tonypavko19682 жыл бұрын
Srpski hi tech
@fakoidrizovic92865 жыл бұрын
Hahaha koja technology
@duskomalinovic91384 жыл бұрын
??????
@andr89874 жыл бұрын
Mudaki
@bulentdemirhan8 жыл бұрын
ne anlatiyolar???
@adiis20097 жыл бұрын
selama ini gue tau nya untuk mengukur kadar air.., menggunakan slump test.., kok ini kerucut nya terbalik yah
@popey21126 жыл бұрын
Karna slump test scc harus gitu
@mattiheikkila62535 жыл бұрын
difficulty full hook fzqkoh professional unexpected program term broken coach three.